SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. Guideline for Expedited Application Review (GEAR) Oil Field Sump Replacement Tanks

Similar documents
San Joaquin Valley Unified Air Pollution Control District

San Joaquin Valley Unified Air Pollution Control District

AUTHORITY TO CONSTRUCT

Title V. Model General Permit Template. SERIES 18 Tanks. Template # SJV-TK

GENERAL PLAN APPROVAL AND GENERAL OPERATING PERMIT BAQ-GPA/GP 2 STORAGE TANKS FOR VOLATILE ORGANIC LIQUIDS

AUTHORITY TO CONSTRUCT

The purpose of this rule is to limit VOC emissions from the transfer of organic liquids.

AIR QUALITY PERMIT. 7 Foundation Drive Savannah, Georgia (Chatham County)

This rule shall apply to any stationary source which is a major source of regulated air pollutants or of hazardous air pollutants.

San Joaquin Valley Unified Air Pollution Control District Permit Services Division

San Joaquin Valley Unified Air Pollution Control District

TRANSFER OF ORGANIC COMPOUNDS INTO MOBILE TRANSPORT TANKS (Effect: 5/6/77: Rev. Effect. 7/26/00)

RULE 2280 PORTABLE EQUIPMENT REGISTRATION (Adopted October 20, 1994; Amended May 16, 1996)

SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001)

WA San Joaquin Valley Imo AIR POLLUTION CONTROL DISTRICT

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT

3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions).

Streamlining Multiple Applicable Requirements

RULE LIQUEFIED PETROLEUM GAS TRANSFER OR DISPENSING (Adopted 1/13/2015)

RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)

Facility Name: Chevron Products Company Doraville Terminal City: Doraville County: DeKalb AIRS #: Application #: 40411

San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the

DRAFT AUTHORITY TO CONSTRUCT

Permit Holder. Permitted Equipment

AIR QUALITY PERMIT. Kennesaw State University - Marietta Campus

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994.

State of New Jersey. Department of Environmental Protection Air Quality Permitting

Regulatory and Permitting Requirements of Stationary Generators In Delaware

Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC

PERMIT APPLICATION REVIEW SUMMARY

ELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95)

WORKSHOP REPORT. No, the RICE NESHAP applies only to stationary engines as defined in 40 CFR

State of New Jersey. Department of Environmental Protection Division of Air Quality

The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706

NARRATIVE. Dika Kuoh Alaa-Eldin A. Afifi DATE: December 14, 2015

Boilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

REGISTRATION REQUIREMENTS FOR EQUIPMENT SUBJECT TO CALIFORNIA S OIL AND GAS REGULATION (Adopted December 21, 2017)

RULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008)

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM

State of New Jersey. Department of Environmental Protection Air Quality Permitting. General Permit (GP-004A) For FUEL DISPENSING FACILITIES

Metro and you, building together.

ALLEGHENY COUNTY HEALTH DEPARTMENT (ACHD) AIR QUALITY PROGRAM

State of New Jersey. Department of Environmental Protection Air Quality Permitting

Note: This rule is effective on July 1, 2018, through June 30, 2019.

REGISTRATION OF SPECIFIED EQUIPMENT (Adopted 5/21/97; Rev. Effective 11/15/00) (1) This rule applies to the following emission units:

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. May 1, 2015 PERMIT TO INSTALL 4-13B. ISSUED TO Zoetis LLC

RULE 326. STORAGE OF REACTIVE ORGANIC COMPOUND LIQUIDS. (Adopted 12/14/1993, revised 1/18/2001)

San Joaquin Valley Iwo AIR POLLUTION CONTROL DISTRICT HEALTHY AIR LIVING'

~ SWCAA. ~awfxm~ Paul T. Mairose Chief Engineer

Imperial County Air Pollution Control District Rule 415

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX

San Joaquin Valley AIR POLLUTION CONTROL DISTRICT

Executive Order G F

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.

RULE 210 AND RULE 213 FEES FOR FISCAL YEAR July 1, 2017

REGULATION II PROHIBITIONS. 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks.

Part 70 Operating Permit Amendment

AIR QUALITY PERMIT. Permit No S Effective Date May 26, 2015

RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS

3. Operation of any applicable boiler on any amount of fuel oil shall be prohibited, except as provided in Subsection C.3.

Facility Name: BASF Corporation Attapulgus Operations City: Attapulgus County: Decatur AIRS #: Application #: 22788

Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary

Crude by Rail. Public Document. Air Permit Application. Valero Benicia Refinery Benicia, California. February

RULE 412 STATIONARY INTERNAL COMBUSTION ENGINES LOCATED AT MAJOR STATIONARY SOURCES OF NO X Adopted INDEX

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. Appendix B: Rule Consistency Analysis August 20, 2009 APPENDIX B. Rule Consistency Analysis

REGULATION II PROHIBITIONS

TRANSFER OF GASOLINE FROM STATIONARY UNDERGROUND STORAGE TANKS INTO VEHICLE FUEL TANKS (Effect. 03/01/06: Rev. 03/26/08)

SWCAA. Southwest Clean Air Agency. October 10, Troy Lomax Longview School District h A venue Longview, WA 98632

Public Service Company of Colorado THE SOURCE TO WHICH THIS PERMIT APPLIES IS DESCRIBED AND LOCATED AS FOLLOWS:

Public Service Company of Colorado THE SOURCE TO WHICH THIS PERMIT APPLIES IS DESCRIBED AND LOCATED AS FOLLOWS:

General Permit (005B) for Emergency Generator(s) burning Gaseous Fuels

REGULATION V PERMIT TO OPERATE REGULATIONS PORTABLE EQUIPMENT REGISTRATION

AIR QUALITY PERMIT. Vulcan Construction Materials, LLC-Gainesville RM

RULE 4702 INTERNAL COMBUSTION ENGINES PHASE 2 (Adopted August 21, 2003; Amended June 16, 2005; Amended April 20, 2006; Amended January 18, 2007)

BACT Determination Information

ATTACHMENT C.1 EXXONMOBIL INTERIM TRUCKING FOR SYU PHASED RESTART AIR QUALITY ANALYSIS

INTERIM DRAFT November 1, 2017

Facility Name: Georgia-Pacific Consumer Products LP Savannah River Mill City: Rincon County: Effingham AIRS #: Application #: 40890

San Joaquin Valley AIR POLLUTION CONTROL DISTRICT

Permit Holder. Permitted Equipment

State of New Jersey. General Permit (GP-009A)

RICE NESHAP Frequently Asked Questions (FAQ)

San Diego County Air Pollution Control District Old Grove Rd San Diego, CA (858) TITLE V OPERATING PERMIT APCD2006-TVP

AIR EMISSION PERMIT NO IS ISSUED TO. Northern Natural Gas Company

PERMIT ISSUED TO LOCATED AT. IN THE Saint Clair NUMBER N7303

(2) An engine subject to this rule or specifically exempt by Subsection (b)(1) of this rule shall not be subject to Rule 68.

E. Augusta, Spokane, WA (509) E. Augusta, Spokane, WA (509)

PERMIT TO INSTALL. Table of Contents

San Joaquin Valley s. AIR POLLUTION CONTROL DISTRICT

State of Utah. Department of Environmental Quality DAQE-IN March 21, 2014

General Plan Approval and General Operating Permit BAQ-GPA/GP-5 and Proposed Exemption 38. Citizens Advisory Council Meeting March 19, 2013

NARRATIVE. Dika Kuoh Steve Allison DATE: August 5, 2015

ifrai San Joaquin Valley mil AIR POLLUTION CONTROL DISTRICT

(2) ANNUAL HEAT INPUT means the actual amount of heat released by fuels burned in a unit during a calendar year.

This rule applies to any internal combustion engine rated at 25 brake horsepower or greater.

Engineering Analysis

Transcription:

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT Guideline for Expedited Application Review (GEAR) Oil Field Sump Replacement Tanks Approved By: Signed Seyed Sadredin Director of Permit Services Date: 8/3/98 Purpose: To outline procedures for processing of Authority to Construct (ATC) applications for oil field sump replacement tanks. I. Applicability This policy applies to Authority to Construct applications for fixed roof sump replacement tanks installed for the sole purpose of complying with District Rule 4402 (Crude Oil Production Sumps). II. Permit Application and Priority Processing For over-the-counter processing, the applicant must submit appropriate fees and a complete application. For applications submitted through mail, if these items are provided at the time of submittal, the applications will be prioritized for issuance within two weeks. The over-the-counter process or the two week priority process will be preempted if the public noticing provisions for Hazardous Material Emissions within 1000 feet of a school apply. III. Background There are numerous crude oil production sumps located in oil fields throughout the San Joaquin valley. Sumps are lined or unlined surface impoundments or excavated depressions in the ground which, during normal operation, is in use for separating crude oil produced water, and solids in oil production fields. Most sumps are relatively small, less than 1,000 barrel (42,000 gallons) capacity. As methods of production and separation improve and cost of maintaining the sumps due the requirements of District Rule 4402 increase, oil production companies are replacing the sumps with aboveground tanks. GEAR 2-1

IV. Policy District Rule 4402 (Crude Oil Production Sumps) was originally adopted on April 11, 1991 and applies to all first, second, and third stage sumps at facilities producing, gathering, separating, processing, and/or storing crude oil in an oil field. Pursuant to subsection 5.3, a sump may be replaced by an above ground tank, provided the tank complies with all applicable requirements of District Rule 4623 (Storage of Organic Liquids) and District Rule 4001 (New Source Performance Standards - Subpart Kb, Volatile Organic Liquid Storage Vessels). If the True Vapor Pressure of the process liquid is 1.5 psia or less, the replacement tank roof appurtenances shall be maintained leak-free and the replacement tank shall be fitted with a pressure/vacuum vent set to within ten (10) percent of the maximum allowable working pressure of the tank. All crude oil production sumps which process material above the oil/water line (as defined in Rule 2020) must have a Permit to Operate. There are some third stage sumps which are below the oil/water line that do not have a Permit to Operate. The replacement of any first, second, or third stage sump with an above ground tank which serves the identical function of the sump replaced requires an Authority to Construct. However, per subsection 5.3 of Rule 4402, the replacement is exempt from the Best Available Control Technology (BACT) and offset requirements of Rule 2201. V. Application Review In order to standardize the application reviews for this source category, the application review found in G:/per/gear/sumptank.doc will be used as a base document. The document is based on a typical existing crude oil production sump. The following pages are a hard copy version of this standard review. This hard copy version for the GEAR Policy manual includes a copy of the standard PTO conditions (Attachment I). The use of this standard Application Review will ensure that the proposed project complies with all applicable prohibitory rules including Rule 4001, 4402 and 4623. Health Risk Assessment HRA is not required as the application is for replacement equipment with no increase in potential to emit. GEAR 2-2

VI. Equipment Description To ensure uniformity of the Authorities to Construct, one of the following standard descriptions will be used: [xx,xxx] GALLON, [xx] FOOT DIAMETER X [xx] FOOT HIGH FIXED ROOF SUMP REPLACEMENT TANK WITH PRESSURE/VACUUM RELIEF VENT or [xx,xxx] GALLON, [xx] FOOT DIAMETER X [xx] FOOT HIGH FIXED ROOF SUMP REPLACEMENT TANK VAPOR CONTROL SYSTEM INCLUDING: XXXX VII. Permit to Operate Conditions To ensure uniformity, a standard set of conditions will be used as a base for all applications (See Attachment I) GEAR 2-3

APPLICATION REVIEW FOR OIL FIELD SUMP REPLACEMENT TANKS GEAR 2-4

ATC APPLICATION REVIEW OIL FIELD SUMP REPLACEMENT TANKS Facility Name: Mailing Address: Processing Engineer: Lead Engineer: Date: Contact Name: Phone: Project Number: Permit Number: I. PROPOSAL: [Facility Name] is applying for an Authority to Construct for a sump replacement tank with a fixed roof and a [shared] tank vapor control system including [system type, i.e., x.x mmbtu/hr flare. The storage tank is proposed as a replacement of a sump (Permit Unit x-xxxx-xx) solely for compliance with District Rule 4402 - Crude Oil Production Sumps; therefore, this project is exempt from Best Available Control Technology (BACT) and offset requirements or Rule 2201. II. APPLICABLE RULES: Rule 2010 Permit Required (December 17, 1992) Rule 2201 New and Modified Stationary Source Review Rule (June 15, 1995) Rule 4001 New Source Performance Standards, Code of Federal Regulations 40 part 60. (September 17,1997) Rule 4101 Visible Emissions (December 17, 1992) Rule 4102 Nuisance (December 17, 1992) Rule 4201 Particulate Matter Concentration (December 17, 1992) Rule 4402 Crude oil production sumps (December 17, 1995) Rule 4623 Storage of Organic Liquids (December 17, 1992) CH&SC 42301.6 California Health and Safety Code (School Notice) GEAR 2-5

III. PROJECT LOCATION: The project is located at: [Lease Name] in [City], CA. xx/4 Section xx, Township xxx, Range xxx of the Mount Diablo Base and Meridian. IV. PROCESS DESCRIPTION: The storage tank is a replacement for a [first stage, second stage, or third stage] crude oil production sump. The storage tank will receive crude oil and/or production water from [list equipment, processes, or state production]. The storage tank will serve the identical function of the crude oil production sump which it replaces and will typically process [gallons per day]. V. EQUIPMENT LISTING: Storage tank specifications Capacity (gallons): Diameter (feet): Height (feet): Bolted, riveted, or welded?[bolted/riveted/welded] Pressure/vacuum relief vent setting (+psia/-psia): Tank vapor control system Control device: [Flare/Thermal Oxidizer/Boiler] Permit Number: (if permitted combustion device) Maximum rating: Supplemental fuel: Compressor activation pressure (psia): Compressor rating (hp): Permit units sharing vapor control system: (if shared vapor space) GEAR 2-6

Fixed roof replacement tank with vapor control system [xx,xxx] GALLON, [xx] FOOT DIAMETER X [xx] FOOT HIGH SUMP REPLACEMENT TANK WITH [SHARED] TANK VAPOR CONTROL SYSTEM [(SHARED WITH PERMIT UNIT # S N/C/S-XXXX-XX)] INCLUDING [SYSTEM TYPE, I.E., X.X MMBTU/HR FLARE OR THERMAL OXIDIZER]. Fixed roof replacement tank [xx,xxx] GALLON, [xx] FOOT DIAMETER X [xx] FOOT HIGH FIXED ROOF SUMP REPLACEMENT TANK WITH PRESSURE/VACUUM RELIEF VENT. VI. EMISSION CONTROL TECHNOLOGY EVALUATION: A. Control Techniques Fixed roof tanks: The proposed storage tank is a fixed roof tank with a pressure/vacuum relief vent. There are no other control equipment associated with this operation. or Vapor Control: The proposed storage tank is equipped with a vapor control system that is expected to reduce emissions by a minimum of 95%. There are no other control equipment associated with this operation B. Best Available Control Technology (BACT) BACT evaluation is not required because the emission unit is exempt from BACT pursuant to Rule 2201, subsection 4.1.1.3. VII. CALCULATIONS The proposed storage tank is a replacement for an existing sump. By placing the material inside an enclosed storage tank of equal or lesser capacity, there is no increase in potential emissions of any criteria air contaminant from the storage of the organic liquid. There is an incineration device with the proposed tank vapor control system. VOC emissions from the storage tank are exempt from offsets pursuant to Rule 2201, subsection 4.2.1.7. Combustion emissions from the incineration device is exempt from offsets pursuant to Rule 4623, subsection 4.3. Any existing daily emissions limits for the existing sump will be placed on the sump replacement tank permit. GEAR 2-7

VIII. COMPLIANCE Rule 2201 - New and Modified Stationary Source Review Rule The replacement of the sump with an aboveground storage tank is a modification as defined in subsection 3.20. Since the proposed sump replacement tank is solely to comply with Rule 4402, emissions from the storage tank are exempt from BACT (per subsection 4.1.1.3) and offsets (per subsection 4.2.1.7). Compliance with this rule is expected. Rule 4001 - New Source Performance Standards, Code of Federal Regulations 40 part 60, Subpart Kb - Volatile Organic Liquid Storage Vessels Exempt storage tank The proposed storage tank has a capacity not exceeding 1598.874 m 3 (420,000 gallons) and stores or processes petroleum prior to custody transfer. The proposed storage tank is exempt from this rule pursuant to subsection 60.110b.d.4. Fixed roof tank with vapor control system Vapor loss prevention system shall be capable of collecting all VOC s so as to prevent their emissions at an efficiency of at least 95% by weight. Any tank gauging or sampling device vented to the vapor recovery system shall be equipped with a gas-tight cover which shall be closed at all times except during gauging or sampling. All piping, valves, and fittings shall be constructed and maintained in a gas-tight condition. The storage tank is equipped with a tank vapor control system which achieves at least 95% control efficiency for VOC emissions. [The tank vapor space is shared with the following permit units # s x-xxxx-x and x-xxxx-x.] All piping, valves, and fittings is required to be constructed and maintained in a gas-tight condition. Permittee will also be expected to satisfy all recordkeeping and reporting requirements as required by the Code of Federal Regulations. Compliance with this rule is expected. GEAR 2-8

Rule 4101 - Visible emissions The incineration device will be fueled with natural gas/propane and tank vapor control gas. Both are clean burning fuels with no expected visible emissions in excess of 20% opacity or Ringlemann #1 for any three minutes in any hour. or Visible emissions are not normally associated with the storage of organic liquids Compliance with this rule is expected. Rule 4102 - Nuisance The facility and sump are existing and do not have a history of nuisance problems. The proposed storage tank will produce less emissions as compared to the open top sump it is replacing; therefore, continued compliance is expected. This project will not result in increased emissions therefore, a Health Risk Assessment is not required pursuant to District Policy Toxic 1. Compliance with this rule is expected to continue. Rule 4201 - Particulate Matter Concentration Total suspended particulate matter emissions shall not exceed 0.1 grains per cubic foot of gas at dry standard conditions. The tank vapor control system will utilize tank vapors and Based on calculations/source tests of similar operations particulate matter emissions are not expected to exceed 0.1 gr./scf. or Particulate matter is not normally associated with the storage of organic liquids. Compliance is expected to continue. Rule 4402 - Crude Oil Production Sumps Pursuant to subsection 5.3, a sump may be replaced with an above ground tank which complies with District Rule 4623, or at a minimum, the tank roof appurtenances shall be maintained leak-free and the tank shall be fitted with a pressure/vacuum vent set to within ten percent of the maximum allowable working pressure of the tank. GEAR 2-9

The proposed above ground tank will be maintained leak-free and will be fitted with a pressure/vacuum vent set to within ten percent of the maximum allowable working pressure of the tank. or The proposed above ground tank satisfies all applicable Rule 4623 requirements. Compliance with this rule is expected. Rule 4623 - Organic Liquid Storage Tanks Fixed roof tank with vapor control system Vapor loss prevention system shall be capable of collecting all VOC s so as to prevent their emissions at an efficiency of at least 95% by weight. Any tank gauging or sampling device vented to the vapor recovery system shall be equipped with a gas-tight cover which shall be closed at all times except during gauging or sampling. All piping, valves, and fittings shall be constructed and maintained in a gas-tight condition. The storage tank is equipped with a tank vapor control system which achieves at least 95% control efficiency for VOC emissions. [The tank vapor space is shared with the following permit units # s x-xxxx-x and x-xxxx-x.] All piping, valves, and fittings is required to be constructed and maintained in a gas-tight condition. Fixed roof tank Tank shall be equipped with a pressure relief device set to within ten (10) percent of the maximum allowable working pressure of the container. The storage tank is equipped with a pressure/vacuum relief vent set to within 10 percent of maximum working pressure. Compliance with this rule is expected. GEAR 2-10

Rule 4801 - Sulfur Compounds Sulfur compound emissions shall not exceed 0.2 percent by volume calculated as sulfur dioxide on a dry basis averaged over 15 consecutive minutes. The tank vapor control system incineration device will use natural gas, LPG, or propane as supplemental fuel. All are clean burning fuels with sulfur content not to exceed 0.2 percent by volume. Tank vapors are not expected to exceed 2000 ppmv. The permittee will be required to test tank vapors prior to incineration at least once every 12 months to verify compliance. or Tank vapors are not expected to exceed 2000 ppmv Compliance with this rule is expected. IX. RECOMMENDATION Issue Authority to Construct [X-XXXX-X-X] with the conditions listed on the attached draft Authority to Construct. X. BILLING The billing for this operation is based on the total storage capacity of the sump replacement tank: [XX,XXX] gallons. PERMIT NUMBER FEE SCHEDULE FEE DESCRIPTION [X-XXXX-XX-X] 3020-[XX-X] GEAR 2-11

ATTACHMENT I Authority to Construct Standard Conditions GEAR 15-11

Fixed Roof with Vapor Control System 1. {118} No air contaminant shall be released into the atmosphere which causes a public nuisance. [District Rule 4102] 2. Permittee shall maintain accurate records of bulk liquid storage temperature and reid vapor pressure (RVP) for a period of two years and make such records readily available for District inspection upon request. [District Rule 4623] 3. Permittee shall satisfy all recordkeeping and reporting requirements as specified in New Source Performance Standards, Code of Federal Regulations 40 part 60, Subpart Kb - Volatile Organic Liquid Storage Vessels. [District Rule 4001] 4. Permittee shall conduct a test of storage tank vapors for sulfur content at least once every 12 months in accordance with ASTM D3246. [District Rule 1081] 5. Permittee shall maintain accurate records of tank vapor sulfur content for a period of two years and make such records readily available for District inspection upon request. [District Rule 1070] General 1. {118} No air contaminant shall be released into the atmosphere which causes a public nuisance. [District Rule 4102] 2. {274}Tank shall be equipped with fixed roof without holes or openings. [District Rule 4402] 3. {275} Tank appurtenances shall be maintained leak free. [District Rule 4401] 4. {276}Tank PV valve shall be set to within 10% of the maximum allowable working pressure of tank. [District Rule 4402] 5. True vapor pressure of (of liquids stored in tank shall not exceed 1.5 psia at storage temperature. [District Rule 4623] Optional if requested by the applicant. 6. The permittee may install a smaller tank provided that a written notification including the exact tank specifications is submitted to the District at least 15 days to initiation of construction. [District Rule 2010] GEAR 15-12

BIBLIOGRAPHY GEAR 15-13

Rules and Regulations Rule Number Title Last Updated District Rule 2010 Permits Required 12/17/1992 District Rule 2201 New and Modified Source Review 06/15/1995 District Rule 4001 New Source Performance Standards, Code of 09/17/1997 Federal Regulations 40 part 60 District Rule 4101 Visible Emissions 12/17/1992 District Rule 4102 Nuisance 12/17/1992 District Rule 4201 Particulate Matter Concentration 12/17/1992 District Rule 4402 Crude Oil Production Sumps 12/17/1992 District Rule 4623 Storage of Organic Liquids 12/17/1992 District Rule 4801 Sulfur Compounds 12/17/1992 Electronic Documents Document Name Title Last Updated G:/per/gear/sumpt ank.doc Standard Application Review for Sump Replacement Tanks. / / Miscellaneous Item Title Last Updated General Conditions General Condition #s 118 11/97 GEAR 15-14