Terminal Boxes Series 8125

Similar documents
Terminal Boxes Series 8125

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Safety Switches Series 8537

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Terminal Boxes Series 8146

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Plug and Socket Devices SolConeX 16 A Series 8570

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Load disconnect switch Series 8146/5-V11

Sheet-Steel Light Fittings Series 6014 / 6414

Control Buttons Series 8082

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Control Buttons / Switches for Panel Mounting Series 8003

Floodlight LED Series 6125

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

8150 Series Terminal Boxes

Floodlight LED Series 6525

Floodlight LED Series 6525

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Floodlight Series 6121

Compact Sheet-Steel Light Fittings Series 6114/1

I Ex-safety switches I

Operating Instructions

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

LED Linear Luminaire Series EXLUX 6402

Linear luminaire with LED Series EXLUX 6002

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Linear Luminaire with LED Series EXLUX 6002

Compact Sheet-Steel Light Fittings Series 6114

Emergency Light Fitting for Fluorescent Lamps Series 6009

Tank Inspection Lights Series 6122

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Control switch/load disconnect switch Series 8008

Sheet Steel Emergency Light Fitting Series 6018

Position Switches Series 8070/2

Emergency Luminaire with LED Series EXLUX 6409/1

Linear Luminaire with LED Series EXLUX 6402/2

7 Lighting Technology

Position Switches Series 8060/2

Control Device System NEC Series ConSig 8040

Metal Position Switch Series 8074

Floodlight Series 6521/4

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Ex UPS standard Series 8265

EX-D ENCLOSURES AND DISTRIBUTIONS

Terminal Boxes in Stainless Steel SLS**.T

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8549

Load and Motor Switches, Load-Break Switches Series 8544

Tubular Light Fitting with LED Series 6036

9 Control Equipment. Control Unit System Series ConSig 8040

Junction box for EKL light

10 Load and Motor Switchgear

EExe and EExi terminal boxes in polyester and aluminium for Ex areas

I Ex-Safety switches I

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

Control and Terminal Box Type A21-**-*****

I Ex-safety switches I

Position Switches Series 8074/2

Data sheet pneumatic barring devices KD80-KD200

Portable Lamps Series HS6145, HSL145

11 Control Panels, Distribution Panels and Components

Battery Boxes Series 8316

7 Lighting Technology

Operating Instructions

EX-REPAIR AND MAINTENANCE RECEPTACLES

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Thermocouple For additional thermowell Model TC10-B

Measuring insert for process resistance thermometer

Resistance thermometer Without thermowell Model TR10-H

Thermocouple Without thermowell Model TC10-H

also in ATEX Data Sheet Enclosures Klippon POK Glass Fibre reinforced Polyester Enclosures

Terminal Boxes Series 8252/1

IECEx Certificate of Conformity

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

A good connection. International approvals.

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

New products Ex Equipment 2015

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

International approvals.

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

A good connection. International approvals.

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Surface thermocouple Model TC50

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Polyester enclosures CP series

The Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Transcription:

Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm > With captive cover screws > Degree of protection IP www.stahl.de Series 00E00 The Series of R. STAHL can offer terminal boxes for almost every individual application. The enclosure is available in electropolished stainless steel.0 (AISI L) or in galvanised steel sheet. The wide product range includes six basic enclosure sizes different heights. Depending on the order, the terminal boxes are fitted terminal blocks and cable glands. Terminals up to a size of 00 mm can be used. Upon request, s made of stainless steel or galvanised steel sheet can be fitted on several sides of the enclosure. ATEX / IECEx Class I (NEC 0) (NEC 0) Class I Class II Class III Zone 0 0 Zone 0 0 Division /: /: x x x x /: x x x x /: x x /: *) *) /: x x ) x x x x x x x *) Approval not required, x ) = Canada WebCode 0-0-0 EK00 III en B Installation Equipment /

Series Selection Table for terminal boxes up to max. mm Nominal cross-section [mm ] Max. number of line-up terminals which can be fitted Order number Weight. 0 Arrangements UK N WDU, MXK UK N WDU UK N WDU UK 0 N WDU 0 UK N WDU UK WDU kg - - /.0-..0 0E00 - /.0-.. 0E00 /.0-.. 0E00 - /.0-.. 0E00 /.0-.. 0E00 /.0-..0 0E00-0 - /.0-.. 0E00 /.0-.. 0E00 0 0 /.0-..0 0E00 - - /.0-.. 00E00 Order Number Supplement: Version: Ex e /...-. Ex i /...-. Material: Sheet steel /...- Stainless steel /...- Specify order: Terminal blocks: Number and type Cable entries: Number, type and installation side in enclosure Flanges: Flanges can be fitted to order; please indicate the side on which they are to be fitted. Note: The order numbers contain the enclosure carrier rails and PE or PA rail. Terminal boxes fitted terminals > mm up to 00 mm on request. / Installation Equipment 0-0-0 EK00 III en

Series Selection Table for terminal boxes up to max. mm Nominal cross-section [mm ] Arrangements Max. number of line-up terminals which can be fitted Order number Weight. 0 UK N WDU, MXK UK N WDU UK N WDU UK 0 N WDU 0 kg - - /.0-.. UK N WDU UK WDU 0E00 0 0 0 - /.0-.. 0E00 - /.0-..0 0E00 /.0-.. 0E00 0 0 0 - /.0-.. 0E00 - /.0-..0 0E00 0 0 /.0-. 0.0 0E00 0 00 0 - /.0-. 0. 0E00 0 - /.0-..0 0-0-0 EK00 III en 0E00 Order Number Supplement: Version: Ex e /...-. Ex i /...-. Material: Sheet steel /...- Stainless steel /...- Specify order: Terminal blocks: Number and type Cable entries: Number, type and installation side in enclosure Flanges: Flanges can be fitted to order; please indicate the side on which they are to be fitted. Note: The order numbers contain the enclosure carrier rails and PE or PA rail. Terminal boxes fitted terminals > mm up to 00 mm on request. Installation Equipment /

Series Explosion Protection Marking IECEx Gas explosion protection Dust explosion protection Europe (ATEX) Gas explosion protection Ex dem [ia] IIC T, T, T Ex ia/ib IIA, IIB, IIC T Ex td IP T0 C, T C, T0 C Dust explosion protection Certificates IECEx IECEx PTB 0.000 Europe (ATEX) PTB 00 ATEX Other certificates Technical Data Electrical data Rated operational voltage E II G Ex dem [ia] IIC T, T, T E II G Ex ia/ib IIA, IIB, IIC T E II D Ex td A IP T0 C, T C, T0 C Brazil (UL do Brasil), India (PESO), Canada (CSA), China (CQST Ex), Kazakhstan (JSC), Korea (KGS), Russia (CTB), USA (UL), Belarus (Gospromnadzor), ship approval (GL) max. 00 V, AC / DC (depending on the terminal type and the explosion protected components used) max. 0 A (depending on the terminal type and the explosion protected components used) Rated operational current Ambient conditions Ambient temperature /: - 0... + C /: - 0... + C (depending on the built-in components) Mechanical data Degree of protection Degree of protection IP (depending on the mounted cable glands) Material Enclosure - Galvanised sheet steel, painted in light grey (RAL 0) - stainless steel.0 (AISI L), electropolished, painting (painting possible to order) Gasket Polyurethane foam Flanges Standard the enclosures are supplied s in the standard version Option the enclosures can be fitted on one or more sides s; material: sheet steel, galvanised or stainless steel Cover fixing Standard captive M stainless steel combo head screws Option cover hinges Assembly / Installation Connection Terminal blocks Tightening torque According to the order directly to the fitted components or to the terminal blocks. The rated operational voltage, the rated operational current and the rated cross section depend on the terminal type used and the explosion protected components. Rated cross section which can be used: max. 00 mm. The maximum number of terminals for the respective enclosure size are indicated in the EC type examination certificate. according to the specifications of the terminal block manufacturers / Installation Equipment 0-0-0 EK00 III en

Series Max. number of cable glands, series, to be mounted Cable gland Attention: The maximum number of cable glands which can be mounted in the enclosure walls depends on the position of the installed mounting rails and components. Enclosure size /.0 /.0 /.0 /.0 M x. M0 x. M x. M x. M0 x. M0 x. M x. 0E00 0E00 0E00 0E00 0E00 A B C D A/B C/D A B C D A/B C/D A B C D A/B C/D A B C D A/B C/D 0 /.0 /.0 /.0 /.0 0 0 M x. M0 x. M x. M x. M0 x. M0 x. M x. 0E00 0E00 0E00 0E00 0E00 A B C D A/B C/D A B C D A/B C/D A B C D A/B C/D A B C D A/B C/D 0 /.0 /.0 /.0 /.0 0 0 0 M x. M0 x. M x. M x. M0 x. M0 x. M x. 0E00 0E00 0E00 0E00 0E00 A B C D A/B C/D A B C D A/B C/D A B C D A/B C/D A B C D A/B C/D 0 0 /.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0E00 M x. M0 x. M x. M x. M0 x. M0 x. M x. 0E00 A B C D A/B C/D 0 0 0 0 0 0 0 0 0-0-0 EK00 III en Installation Equipment /

Series Accessories and Spare Parts Designation Illustration Description Order number Weight kg Flange Sheet steel 0.00 00E00 x x mm Stainless steel 0 0.0 /.0 C / D /.0 A / B / C/ D /.0 A / B / C/ D /.S C / D /.0 A / B / C / D Sheet steel 0.000.00 0E00 x x mm Stainless steel 0.0 0E00 /.0 C / D /.0, /.0 A / B / C / D /.0, /.0 A / B / C / D Sheet steel x x mm Stainless steel.00 0.0 /.0 A / B / C / D /.0 A / B Sheet steel.0 0E00 x x mm Stainless steel. /.0 A / B / C /.0 A / B / C Frame 0 x mm 0 0.00 00E00 x mm x mm x mm x mm 0.00 0 0.00 0.00 0.0 Cover hinge 0E00 for retrofitting to enclosures Mounting set consisting of: hinges 0.0 hinges 0.0 / Installation Equipment 0-0-0 EK00 III en

Series Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 0E00 0E00 0E00 /.0. /.0. /.0. Additional dimension for 00E00 0E00 /.0. /.0. 0E00 Enclosure height h Enclosure /... mm /... 0 mm /... 0 mm /... 0 mm /.0. X - /.0. X - /.0 X X /.0. X X /.0. X X X X /.0. X X X - X... can be supplied /.0. 0E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available notice. The illustrations cannot be considered binding. 0-0-0 EK00 III en Installation Equipment /