Earlier Lecture. For an optimum design of a Stirling cryocooler, a compromise between the operating and the design parameters may be sought.

Similar documents
Pressure Ratio Effect to Warm Displacer Type Pulse Tube Refrigerator

Available online at ScienceDirect. Physics Procedia 67 (2015 )

IOP Conference Series: Materials Science and Engineering. Related content PAPER OPEN ACCESS

Experimental Investigation of a 40K Single Stage High Frequency Pulse Tube Cryocooler

Gas Spring Effect in a Displacer Pulse Tube Refrigerator

Development of the LPT W Concentric Pulse Tube

A Thermoacoustically Driven Two-Stage Pulse Tube Cryocooler

Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers

Development of a High Frequency Pulse Tube

The Development of a New Generation of Miniature Long-Life Linear Coolers

Development of a High Frequency Pulse Tube

Internal Combustion Engines

Applications of Pneumatics and Hydraulics

On the numerical design of a new type of 4 K GM/PT hybrid refrigerators

(Refer Slide Time: 1:13)

FLUID POWER P&IDs. IDENTIFY the symbols used on engineering fluid power drawings for the following components:

Clearance Loss Analysis in Linear Compressor with CFD Method

Available online at ScienceDirect. Physics Procedia 67 (2015 )

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

High Capacity Flexure Bearing Stirling Cryocooler On-Board the ISS. Sassenage, France (2) THALES Cryogenics B.V. Eindhoven, The Netherlands

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

UNIT 2 POWER PLANTS 2.1 INTRODUCTION 2.2 CLASSIFICATION OF IC ENGINES. Objectives. Structure. 2.1 Introduction

Design and Analysis of Stirling Engines. Justin Denno Advised by Dr. Raouf Selim

Data Sheet 2s102K Cryocooler

Long Transfer Lines Enabling Large Separations between Compressor and Coldhead for High- Frequency Acoustic-Stirling ( Pulse-Tube ) Coolers

Overview of Micro-Miniature Stirling Cryocoolers for High Temperature Applications

Abstract. Introduction

The Performance Optimization of Rolling Piston Compressors Based on CFD Simulation

High Speed Gears - New Developments

HYBRID LINEAR ACTUATORS BASICS

Cryocooler with Cold Compressor for Deep Space Applications

Creating Linear Motion One Step at a Time

Chart, Inc. Data Sheet 2s241K Cryocooler

NOVEL DIAPHRAGM BASED STIRLING CRYOCOOLER. A.J. Caughley 1, A Tucker 2, M Gschwendtner 3, and M Sellier 2 ABSTRACT

Gas Power Cycles. Tarawneh

Heat engine. Heat engine

2013 THERMAL ENGINEERING-I

Numerical Simulation and Performance Analysis of Rotary Vane Compressors for Automobile Air Conditioner

THEORETICAL ASSESSMENT OF A STIRLING ENGINE 'AMAZON' BY USING PROSA AND MATHCAD

Reliability Evaluation of Stirling Cryocooler for an Electric Vehicle High Temperature Superconducting Motor System

MODULE- 5 : INTRODUCTION TO HYDROSTATIC UNITS (PUMPS AND MOTORS)

Topic 1. Basics of Oil Hydraulic Systems

Hot Air Engine, Type Stirling

2. Discuss the effects of the following operating variables on detonation

Design and Test of Transonic Compressor Rotor with Tandem Cascade

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

Scheme - G. Sample Test Paper-I. Course Name : Diploma in Mechanical Engineering Course Code : ME Semester : Fifth Subject Title : Power Engineering

Dynamics of Machines. Prof. Amitabha Ghosh. Department of Mechanical Engineering. Indian Institute of Technology, Kanpur. Module No.

Four-Quadrant Multi-Fluid Pump/Motor

Electromagnetic Fully Flexible Valve Actuator

GOVERNMENT ENGINEERING COLLEGE, GODHRA

Attention is drawn to the following places, which may be of interest for search:

Mohammad Faisal Haider. Department of Mechanical Engineering Bangladesh University of Engineering and Technology

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI

Data Sheet 2s102K Cryocooler

LSC Series. Open Drive Large Screw Compressors. Fifteen Displacements. 50-2,500 TR (176-8,785 kw) 278-3,336 CFM 100-2,200 HP

TechNote #27 ROTALIGN

Cooldown Measurements in a Standing Wave Thermoacoustic Refrigerator

Pulse Tube Microcooler for Space Applications

(a) then mean effective pressure and the indicated power for each end ; (b) the total indicated power : [16]

OPTIMIZATION IN GENERATION FROM A HORIZONTAL AXIS WIND TURBINE VIA BLADE PITCH CONTROL AND STRUCTURE MORPHING

White Paper. Electromechanical Actuators in the Automotive Industry Roller screw actuators for weld gun applications

Design of a Large Heat Lift 40 to 80 K Pulse Tube Cryocooler for Space Applications

Idealizations Help Manage Analysis of Complex Processes

Lecture 1: Heat Exchangers Classifications

Lab 6: Electrical Motors

Chapter 6. Supercharging

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

INVENTION DISCLOSURE MECHANICAL SUBJECT MATTER EFFICIENCY ENHANCEMENT OF A NEW TWO-MOTOR HYBRID SYSTEM

Chapter 9 GAS POWER CYCLES

First Domestic High-Efficiency Centrifugal Chiller with Magnetic Bearings: The ETI-MB Series

A Practical Guide to Free Energy Devices

BASIC PUMP TECHNOLOGY

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:

Syslog Technologies Innovative Thoughts

International Engineering Research Journal Design, Development and Testing of Opposed Piston Linear Compressor for Household Refrigerator

Advantages of a Magnetically Driven Gear Pump By Steven E. Owen, P.E.

Infinitely Variable Capacity Control

PREVIEW ONLY. Course 106 INSTRUCTOR GUIDE. HVAC Systems Introduction and Overview. Module 1: Overview of Rail Car HVAC and General Safety Procedures

2. Engine Ignition Types. Worksheet: Engine Classification

Chapter 9 GAS POWER CYCLES

WINTER 14 EXAMINATION

Instructor Guide. 215: Elevator: Mechanical Drive Systems Module 4: Hydraulic Drive Systems

MSC 110mm Series Vertical Medium Screw Compressors

Internal Combustion Engines

Analysis of Parametric Studies on the Impact of Piston Velocity Profile On the Performance of a Single Cylinder Diesel Engine

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL HYDRAULIC AND PNEUMATIC MOTORS. This work covers part of outcome 2 of the Edexcel standard module:

Discussion of Marine Stirling Engine Systems

COURSE TITLE : GENERAL ENGINEERING COURSE CODE : COURSE CATEGORY : F PERIODS/WEEK : 4 PERIODS/SEMESTER : 72 CREDITS : 4

Structural Analysis Of Reciprocating Compressor Manifold

Table of Contents. 4. Before a New Turbocharger is Installed

National Conference on Recent Innovations in Science And Engineering (NCRISE)

Gas Power System. By Ertanto Vetra

Gas Turbine Power Plant

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

EEEE 524/624: Fall 2017 Advances in Power Systems

A Novel Automotive Two-Stage A/C Compressor

Piston spool valves and poppet valves - A technical comparison of available solenoid valves

THERMAL MANAGEMENT OF AIRCRAFT BRAKING SYSTEM

Transcription:

29 1

Earlier Lecture For an optimum design of a Stirling cryocooler, a compromise between the operating and the design parameters may be sought. Based on Schmidt s analysis, the variation of Q E /(p max V T ) and W T /(p max V T ) for a few non dimensional numbers was presented. A combined effect of parameters on performance of system as a whole, is given in Walker s optimization charts. 2

Earlier Lecture In order to account for the various losses and to make the analysis more realistic, we have Q E, Design = 3 X Q E, Reqd. In the earlier lecture, a tutorial problem was solved on Stirling cryocooler design using the Walker s Optimization Charts. For a given Q E, Design, if the dimensions of the piston and expander displacer are very large, the system is designed for two cylinders or more. 3

Outline of the Lecture Topic : Cryocoolers Gifford McMahon (GM) Cryocooler GM and Stirling Cryocooler A comparison Working of a GM Cryocooler Regenerators, Valve mechanism Applications 4

Cryogenic Refrigeration Closed Cycle Dynamic Introduction Regenerative Recuperative Valves GM, Pulse Tube Valve less Stirling Pulse Tube J T, Claude In the earlier lecture, we have seen the classification of cryogenic refrigeration. The closed cycle division of the same is as shown. 5

Cryogenic Refrigeration Regenerative Closed Cycle Dynamic Introduction Recuperative The working of a valve less, closed cycle, regenerative type, Stirling Cryocooler was discussed. Valves GM, Pulse Tube Valve less Stirling Pulse Tube J T, Claude On the other hand, the valved system under the regenerative type is the Gifford McMahon (GM) Cryocooler. 6

W 0 Gifford McMahon System The schematic of a Gifford McMahon (GM) system is as shown in the figure. Q 0, T0 W. E. Gifford and H. O. Mc Mahon were the first to present this idea of introduction of valves in the year 1950. V 1 V 2 This valve mechanism is used to generate the pressure variation or the pressure pulse. Q, T c c G M This working cycle was later named as Gifford McMahon cycle. 7

W 0 Gifford McMahon System The sequential opening and closing of these valves generate the required pressure variation or the pressure pulse. Q 0, T0 V 1 The timing of the valves in relation to the position of the displacer is vital for optimum operation. Q, T c c G M V 2 Therefore in a GM system, there is a relation between the pressure pulse generated by the valve mechanism and the expander displacer motion. 8

W 0 Gifford McMahon System Different variations in the valve design for a GM Cryocooler are possible. Q 0, T0 Some of the systems may have one valve each on the high and the low pressure lines. V 1 Also, some of the systems may have poppet valves, solenoid valves. Q, T c c G M V 2 Commercially available cryocoolers have rotary valves to control or regulate the flow of the working medium. 9

A Comparison W 0 W 0 Q 0, T0 Q 0, T0 At low frequencies, the rubbing seal between the displacer and the cylinder is perfect. Q, T c c Stirling Q, T c c G M The valves facilitates production of any kind of pressure wave as per the requirement of system. 10

W 0 Q 0, T0 Q 0, T0 A Comparison W 0 Stirling cryocooler is a high frequency machine where as, a GM Cryocooler is a low frequency machine. Q, T c c Stirling Q, T c c G M Although, presence of valves deteriorates the system performance, but it is possible to reach much lower temperatures using a GM system as compared to a Stirling system. 11

Stirling Electrical Input ~ - AC W 0 Q 0, T0 pv work output A Comparison 20 140 Hz ~ - AC 85 % G M Electrical Input W Q 0, T0 0 ~ - AC 50 Hz pv work output -- - DC 1 2 Hz ~ - AC 50 % 50 % Efficiency: 85% Efficiency: 25% 12

Stirling 20 150 Hz frequency. Direct connection (Compressor expander). Dry compressor. High COP (10 W at 80 K, 350 W). Low pressure ratios. 20 K using two stages. Low power compressors and compact. A Comparison Gifford - McMahon 1 5 Hz frequency. Valved connection (Compressor expander). Lubricated compressor. Low COP (100 W at 80 K, 4000 W+Q chill ). High pressure ratios. 4 K using two stages. High power compressors and bulky. 13

Stirling Miniaturization is possible due to fewer moving parts. Suitable for space application. A Comparison Gifford - McMahon Miniaturization is not possible due to the valves. Mostly, land based applications. 14

Displacer V 1 V 2 Working of GM Cryocooler Seals HP Consider a displacer housing the regenerator, at BDC position as shown in the figure. Regenerator LP The cold space (V 1 ) and the warm space (V 2 ) are as shown. In this schematic, both the high (HP) and low (LP) valves are in closed position. The seals are provided to reduce the leakage across the displacer. 15

Working of GM Cryocooler Displacer Seals HP V 2 V 1 Regenerator p LP The corresponding situation of the cold space (V 1 ), when plotted on a pv diagram is as shown in the adjacent figure. LP V min V 1 16

V 1 V 2 Working of GM Cryocooler HP HP LP p With the opening of the HP valve, the high pressures gas fills V 1 and V 2 spaces at a constant volume as shown in the figure. LP V min V 1 17

V 1 V 2 Working of GM Cryocooler HP HP LP p The displacer moves back displacing the gas from V 2 to V 1 at a constant pressure. LP V min V maxv 1 The cold space volume (V 1 ) increases where as, the warm space volume (V 2 ) decreases. 18

V 1 V 2 Working of GM Cryocooler HP LP p HP Now, the HP valve is closed and LP valve is opened. This leads to an expansion of gas, reducing the pressure from HP to LP. LP V min V max V 1 This expansion produces cold in cold space volume (V 1 ). 19

V 1 V 2 Working of GM Cryocooler HP HP LP p The displacer moves back, reducing the cold space volume (V 1 ). LP The cycle continues to produce lower and lower temperatures. V min V maxv 1 20

Multistaging in GM Cryocooler 2 nd Stage Cold End 1 st Stage Cold End A single stage GM cryocooler produces a refrigeration effect of 12 W at 80 K, for a 1.2 kw input power. In order to reach much lower temperatures, say, in the order of 10 K to 4.2 K, multistaging is done in these systems. 21

Multistaging in GM Cryocooler 2 nd Stage Cold End 1 st Stage Cold End Commercially available two stage GM cryocoolers are capable of reaching temperatures lower than 4.2 K. 22

Components of GM Cryocooler Video of GM cryocooler. For the sake of understanding, a demo video of a GM cryocooler at IIT Bombay is shown. It is a two stage machine capable of reaching a temperature of 10 K. 23

Components of GM Cryocooler The basic components of any GM cryocooler are as listed below. Helium compressor scroll/reciprocating type. Flex lines HP line, LP line. Regenerator(s) and Displacer(s). Valve mechanism rotary, solenoid, poppet. Cooling arrangements Air or water cooled. 24

Regenerators The regenerator is the most vital component and is often called as a heart of a cryocooler. The major aspects of a regenerator are Dimensions length, diameter. Material Heat capacity, thermal conductivity. Porosity. Working temperature. Heat transfer and minimum pressure drop. 25

Regenerators In general, a material with high heat capacity is chosen as a regenerator material. This is because, the energy exchanged between the working gas and the matrix is directly dependent on the relative heat capacity. As seen in the earlier lectures, it is important to note that the C P of a material decreases with the decrease in the temperature. Very often, a combination of various rare earth materials is used as a regenerator material. 26

1.2 1.0 0.8 0.6 0.4 Lead SS Er 3 Ni Neodymium Regenerators The variation of volumetric heat capacity with temperature is as shown. Materials like SS are not preferred at lower temperatures (~ 30 K) due to low heat capacity. 0.2 0 4 10 30 40 Temperature, K 50 Materials like Lead, Er 3 Ni and Neodymium exhibit high heat capacities at lower temperatures. 27

1.2 1.0 0.8 0.6 0.4 Lead SS Er 3 Ni Neodymium Regenerators In single stage GM systems (~ 30 K), SS meshes are used. Two stage (~ 10 K) 1 st stage: SS mesh 2 nd stage: Lead balls 0.2 0 4 10 30 40 Temperature, K 50 Two stage (~ 4.2 K) 1 st stage: SS + Lead 2 nd stage: Lead + Er 3 Ni. 28

Valve Mechanism As mentioned earlier, the sequential opening and closing of the valve mechanism, generates the required pressure variation or the pressure pulse. The rotary valve should operate at an optimum frequency. The schematic and the working of a most commonly used rotary valve is explained in the next slide. 29

Drive mechanism HP port Valve Mechanism The various parts of a rotary valve are as listed below. LP port Drive mechanism HP, LP ports Rotor, Stator Cryocooler The rotor is driven by a drive mechanism, maintaining a perfect seal on the stator. Rotor Stator The slotted rotor and stator discs, connect the cryocooler to HP and LP lines respectively. 30

Drive mechanism Valve Mechanism HP port LP port Cryocooler High Pressure Position When the slots on the rotor disc match with the stator as shown, the high pressure gas from the compressor flows to the cryocooler. Rotor Stator In this position, the LP port is masked/closed. 31

Drive mechanism Valve Mechanism HP port Cryocooler LP port Low Pressure Position With the rotation of the rotor disc, at a particular instant, the slots on the rotor disc are masked/closed. Rotor Stator In this position, the hole in the stator is unmasked/opened, connecting the cryocooler to the LP port, as shown in the figure. 32

Applications GM cryocoolers find applications in the following areas. MRI machines Cryo pumps N 2 liquefiers Cryoprobes These machines also find applications in areas like low temperature physics and scientific applications. 33

Summary W. E. Gifford and H. O. Mc Mahon were the first to present this idea of introduction of valves in the year 1950. A GM system has a valve mechanism to control/regulate the flow between the compressor and the regenerator displacer assembly. For an optimum performance, the relation between the pressure pulse generated by the valve mechanism and the expander displacer motion is vital. 34

Summary A GM system can reach much lower temperatures as compared to a Stirling system, but may require a high powered compressor due to the inefficiency of the valves. Multistaging is done to reach lower temperatures (4.2 K to 10 K). The basic components are Helium compressor, Flex lines, Regenerator(s), Displacer(s) and Valve mechanism. 35

Summary The choice of the regenerator material is dependent on the lowest working temperature of the cryocooler. Single stage (~ 30 K), SS mesh. 2 stage (~ 10 K), 1 st stage: SS mesh, 2 nd stage: Lead balls. 2 stage (~ 4.2 K), 1 st stage: SS mesh + Lead balls, 2 nd stage: Lead balls + Er 3 Ni balls. Commercially available cryocoolers have rotary valves to control/regulate the flow. 36

A self assessment exercise is given after this slide. Kindly asses yourself for this lecture. 37

Self Assessment 1. is used to generate the pressure variation in a GM system. 2. In a GM cycle, the relation between the pressure pulse and the is vital. 3. Rubbing seals between the displacer and the cylinder is perfect at frequencies. 4. In a system, miniaturization is not possible due to the valves. 5. In GM systems, is done in order to reach lower temperatures. 6. is the most vital component and is often called as a heart of a cryocooler. 7. decreases with the decrease in temperature. 38

Self Assessment 8. Materials like, and exhibit high heat capacities at lower temperatures. 9. Rotary valve should operate at an frequency. 10. Commercially available cryocoolers have types of valves to control/regulate the flow. 39

1. Valve mechanism Answers 2. Expander displacer piston. 3. Low 4. GM 5. Multistaging 6. Regenerator 7. C P 8. Lead, Er 3 Ni and Neodymium 9. Optimum 10.Rotary 40

Thank You! 41