K-Series Rooftop Units 60 HZ

Similar documents
K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

K-Series Rooftop Units 50 HZ

K-Series Rooftop Units 50 HZ

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS

Landmark Rooftop Units 50 HZ

Landmark Rooftop Units 50 HZ

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

K-Series Rooftop Units 60 HZ

Z-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

Landmark Rooftop Units 60 HZ PRODUCT SPECIFICATIONS

ZCA. Raider Rooftop Units 60 HZ. ASHRAE 90.1 COMPLIANT 3 to 6 Tons Net Cooling Capacity 34,600 to 68,000 Btuh Optional Electric Heat - 5 to 30 kw

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KGA (5/2013)

Landmark Rooftop Units 50 HZ

ASHRAE 90.1 COMPLIANT

K-Series Rooftop Units Standard and High Efficiency - 60 HZ

Z-Series Rooftop Units 60 HZ

Landmark Rooftop Units 50 HZ

Z-Series Rooftop Units 60 HZ

ROOFTOP UNITS 60 HZ P A C K A G E D H E A T P U M P

ASHRAE 90.1 COMPLIANT

Z-Series Rooftop Units 60 HZ

Landmark Rooftop Units Standard and High Efficiency - 60 HZ

T CLASS ROOFTOP UNITS 60 HZ Bulletin No July 2008 Supersedes August 2007

ROOFTOP UNITS 60 HZ P A C K A G E D E L E C T R I C / E L E C T R I C

Z-Series Rooftop Units 50 HZ

T CLASS ROOFTOP UNITS 60 HZ

K-Series Rooftop Units Standard and High Efficiency - 60 HZ

Packaged L Series LCA/LGA/LHA

K-Series Rooftop Units Standard Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT

FEATURES AND BENEFITS

ZHA/ZHB SERIES WARNING

E-Series Rooftop Units 50 HZ

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS

Landmark Rooftop Units Standard and High Efficiency - 60 HZ PRODUCT SPECIFICATIONS

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature

K-Series Rooftop Units 50 HZ

Energence Ultra-High Efficiency Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No

K-Series Rooftop Units Standard and High Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT

K-Series Rooftop Units Dual-Fuel - High Efficiency - 60 HZ

K-Series Rooftop Units 50 HZ

T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ

CHP

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

13 GCS X A X Nominal SEER Minor Revision Number

T A A 120 S 4 D - 1 M

Energence Ultra-High Efficiency Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

Factory Option Codes L M E S P R D V F F H E

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

ELITE SERIES R-410A Ready - Multi-Position

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

TCA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

2SG13 60HZ P A C K A G E D G A S / E L E C T R I C

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

ELITE Series R-410A - Upflow / Horizontal

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Packaged L Series LCA/LGA/LHA

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

K-SERIES COMMERCIAL PACKAGED ROOFTOP UNITS 2- TO 25-TON KG/KC/KH MODELS UP TO 16.5 SEER, 14.8 IEER AND 13.0 EER

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

GR4GA Series Single Packaged Gas/Electric Units

D M S 760 C01 A A 1 1

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units

GR4GC Series Single Packaged Gas/Electric Units

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

SERIES GCS PACKAGED UNITS COOLING & GAS HEAT

ELITE COMMERCIAL SPLIT SYSTEMS UPFLOW/HORIZONTAL - R-410A - 60 HZ

ENERGY RECOVERY SYSTEM 60 HZ

TECHNICAL SPECIFICATIONS

R-22, 13 SEER 60 Hertz

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

SINGLE PACKAGE HEAT PUMPS

Q4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS

Transcription:

PRODUCT SPECIFICATIONS PACKAGED GAS ELECTRIC KG K-Series Rooftop Units 60 HZ Bulletin No. KGA-80-00 (6/0) MODEL NUMBER IDENTIFICATION ASHRAE 90. COMPLIANT to 5 Tons Net Cooling Capacity 5,000 to 70,000 Btuh Gas Input Heat Capacity 60,000 to 480,000 Btuh Brand/Family K = K-Series Unit Type G = Packaged Gas Heat w/ Electric Cooling Major Design Sequence A = st Generation K G A 40 S 4 B S Y Voltage Y = 08/0V- phase-60hz G = 460V- phase-60hz J = 575V- phase-60hz Minor Design Sequence = st Revision = nd Revision = rd Revision Nominal Cooling Capacity - Tons 56 = Tons 80 = 5 Tons 0 = 7.5 Tons 40 = 0 Tons 00 = 5 Tons Cooling Efficiency H = High Efficiency S = Standard Efficiency Heating Type S = Standard Gas Heat, Stage M = Medium Gas Heat, Stage H = High Gas Heat, Stage Blower Type B = Belt Drive, Constant Air Volume (CAV) M = Single Zone VAV Supply Fan Supply Air Blower, Option, Belt Drive Refrigerant Type 4 = R-40A

FEATURES AND BENEFITS H D N O M H L J F E G K C B K-Series rooftop units from Allied are the new standard for reliable, efficient rooftop units built for long-lasting performance that can significantly improve indoor and outdoor environments. K-Series rooftop units feature: Aluminized Steel Heat Exchanger With Inshot Burners - Life cycle tested. R-40A Refrigerant - Environmentally friendly. Scroll Compressors - Single speed scroll compressors are furnished on all models. Eco-last Coil System - Smaller, lighter condenser coil. High Pressure Switches - Protect compressor. Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow. Independent Outdoor Fan Motor Mounts - Allows for easy and efficient service access without removing the top panel. Constant Air Volume (CAV) or Single Zone VAV Supply Fan Blower Option - Allows constant or multi-staged air delivery. Downflow Airflow - Horizontal airflow with optional horizontal curb. Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle. Corrosion-Resistant Removable, Drain Pan - Provides application flexibility, durability and improved serviceability. Thermostatic Expansion Valves - Provide peak cooling performance across the entire application range. MERV 8 or MERV Filters - Available as field installed option, provide an enhanced level of indoor air quality, and can help the building qualify for additional LEED credits. K-Series Packaged Gas / Electric to 5 Ton / Page

FEATURES AND BENEFITS Contents Accessory Dimensions...........................45 Blower Data................................ 0 Dimensions.................................4 Electrical Accessories........................... 8 Electrical Data............................... Features And Benefits........................... High Altitude Derate............................0 Model Number Identification........................ Options / Accessories - High Efficiency Models.............. Options / Accessories - Standard Efficiency Models............ 9 Outdoor Sound Data............................40 Ratings................................... Specifications - Gas Heat......................... 0 Specifications - High Efficiency Models.................. 7 Specifications - Standard Efficiency Models................5 Unit Clearances.............................. 9 Weight Data................................ 4 APPROVALS Efficiency rating CSA. Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes. All models are certified in accordance with the ULE certification program, which is based on AHRI Standard 40/60-007. All models are ASHRAE 90.-00 energy efficiency compliant and meet or exceed requirements of Section 6.8. Single Zone VAV Supply Fan models meet California Code of Regulations, Title 4 and ASHRAE 90.-00 Section 6.4..0 requirements for staged airflow. ISO 900 Registered Manufacturing Quality System. B WARRANTY Limited ten years aluminized heat exchanger, limited fifteen years optional stainless steel heat exchanger. Limited five years on compressors. Limited three years on the Eco-last Coil System. Limited one year all other covered components. HEATING SYSTEM Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic dual stage gas valve with manual shut-off. Heat Exchanger Tubular construction, aluminized steel, life cycle tested. Optional Stainless Steel Heat Exchanger is required if mixed air temperature is below 45 F. Electronic Pilot Ignition Electronic spark igniter provides positive direct ignition of burners on each operating cycle. The system permits main gas valve to stay open only when the burners are proven to be lit. Should a loss of flame occur, the gas valve closes, shutting off the gas to the burners. Ignition module has LED to indicate status and aid in troubleshooting. Ignition control is factory installed in the controls section. Limit Controls Factory installed, redundant limit controls with fixed temperature setting. Heat limit controls protect heat exchanger and other components from overheating. Safety Switches Flame roll-out switch, flame sensor and combustion air inducer proving switch protect system operation. REQUIRED SELECTIONS Gas Input Choice - Order one: Standard Gas Heat, Stage (69,000/60,000 Btuh) Medium Gas Heat, Stage (4,000/60,000 Btuh) High Gas Heat, Stage (,000/480,000 Btuh) OPTIONS/ACCESSORIES Factory Installed Stainless Steel Heat Exchanger Required if mixed air temperature is below 45 F. Factory or Field Installed Low Vestibule Heater Electric heater automatically controls minimum temperature in gas burner compartment when temperature is below -40 F. CSA certified to allow operation of unit down to -60 F. Field Installed Bottom Gas Piping Kit Allows bottom gas entry. K-Series Packaged Gas / Electric to 5 Ton / Page

C FEATURES AND BENEFITS HEATING SYSTEM (CONTINUED) Combustion Air Intake Extensions Recommended for use with existing flue extension kits in areas where high snow areas can block intake air. Order two kits. LPG/Propane Kits Conversion kit to field change over units from Natural Gas to LPG/ Propane. Order two kits. Vertical Vent Extension Kit Use to exhaust flue gases vertically above unit. Required when unit vent is too close to fresh air intakes per building codes. The vent kit also prevents ice formation on intake louvers. Order two kits. Kit contains vent transition, vent tee, drain cap and installation hardware. NOTE - Straight vent pipes (4 in. B-Vent) and caps are not furnished and must be field supplied. Refer to kit instructions for additional information. COOLING SYSTEM Designed to maximize sensible and latent cooling performance at design conditions. System can operate from 0 F to 5 F without any additional controls. R-40A Refrigerant Non-chlorine based, ozone friendly, R-40A. Scroll Compressors Scroll compressors on all models for high performance, reliability and quiet operation. Resiliently mounted on rubber grommets for quiet operation. D E F Thermal Expansion Valves (High Efficiency Models) Assures optimal performance throughout the application range. Removable element head. Refrigerant Metering Orifice (Standard Efficiency Models) Accurately meters refrigerant in system. Refrigerant control is accomplished by exact sizing of refrigerant metering orifice. Filter/Driers High capacity filter/drier protects the system from dirt and moisture. High Pressure Switches Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation. Freezestats Protects the evaporator coil from damaging ice build-up due to conditions such as low/no airflow, or low refrigerant charge. Eco-last Coil System Condenser coil features lightweight, all aluminum brazed fin construction. Constructed of three components: a flat extrusion tube, fins inbetween the flat extrusion tube and two refrigerant manifolds. G Eco-last Coil System Features: Improved heat transfer performance due to high primary surface area (flat tubes) versus secondary surface (fins). Smaller internal volume (reduced refrigerant charge). High durability (all aluminum construction). Fewer brazed joints. Compact design (reduces unit weight). Easy maintenance/cleaning. Face split design. Mounting brackets with rubber inserts secure coil to unit providing vibration dampening and corrosion protection. Angled design in cabinet helps protect coil from possible contact or hail damage. Evaporator Coil Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested. Cross row circuiting with rifled tubing optimizes both sensible and latent cooling capacity. Condensate Drain Pan Plastic pan, sloped to meet drainage requirements of ASHRAE 6.. Side or bottom drain connections. Outdoor Coil Fan Motors Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount. Outdoor Coil Fans PVC coated fan guard furnished. REQUIRED SELECTIONS Cooling Capacity Specify nominal cooling capacity of the unit K-Series Packaged Gas / Electric to 5 Ton / Page 4

FEATURES AND BENEFITS OPTIONS/ACCESSORIES Field Installed Condensate Drain Trap Available in copper or PVC. Drain Pan Overflow Switch Monitors condensate level in drain pan, shuts down unit if drain becomes clogged. Low Ambient Kit (Includes Compressor Crankcase Heater) Cycles the outdoor fans while allowing compressor operation in the cooling cycle. This intermittent fan operation allows the system to operate without icing the evaporator coil and losing capacity. Designed for use in ambient temperatures no lower than 0 F. Low Ambient Kit also controls the compressor crankcase heaters. Compressor crankcase heater is furnished with kit. Protects against refrigerant migration that can occur during low ambient operation. H CABINET Construction Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation. Base rails have rigging holes. Three sides of the base rail have forklift slots. Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building. Airflow Choice Units are available in downflow (vertical) or horizontal return air flow configuration. Horizontal air flow requires Horizontal Roof Curb. Horizontal Return Air Panel Kit is also required if converting a downflow configured unit to horizontal air flow. Power/Gas Entry Electrical and gas lines can be brought through the unit base or through horizontal access knockouts Exterior Panels Constructed of heavy-gauge, galvanized steel with a two-layer enamel paint finish. Insulation All panels adjacent to conditioned air are fully insulated with nonhygroscopic fiberglass insulation. Unit base is fully insulated. The insulation also serves as an air seal to the roof curb, eliminating the need to add a seal during installation. Access Panels Access panels are provided for the economizer/filter section, heating/blower section, and the compressor/controls section. OPTIONS/ACCESSORIES Factory Installed Corrosion Protection A completely flexible immersed coating with an electrodeposited dry film process. (AST ElectroFin E-Coat) Meets Mil Spec MIL-P-5084, ASTM B7 Standard Method Salt Spray Testing. Indoor Corrosion Protection: - Coated coil - Painted blower housing - Painted indoor base Outdoor Corrosion Protection: - Coated coil - Painted outdoor base Hinged Access Panels Hinged access panels for the filter section, the blower section and compressor/controls section. All hinged panels have seals and quarter-turn latching handles to provide a tight air and water seal. Field Installed Coil Guards Painted, galvanized steel wire guards to protect outdoor coil. Not used with Hail Guards. Hail Guards Constructed of heavy gauge steel, painted to match cabinet, helps protect outdoor coils from hail damage. Not used with Coil Guards. Horizontal Return Air Panel Kit Required for horizontal applications with Horizontal Roof Curb, contains panel with return air opening for field replacement of existing unit panel and panel to cover bottom return air opening in unit, see dimension drawings. K-Series Packaged Gas / Electric to 5 Ton / Page 5

I FEATURES AND BENEFITS BLOWER A wide selection of supply air blower options are available to meet a variety of airflow requirements. Motor Overload protected, equipped with ball bearings. Belt drive motors are offered on all models and are available in several different sizes to maximize air performance. Supply Air Blower Forward curved blades, double inlet, blower wheel is statically and dynamically balanced. Equipped with ball bearings and adjustable pulley (allows speed change),. Blower assembly slides out of unit for servicing. REQUIRED SELECTIONS Select Constant Air Volume (CAV) or Single Zone VAV Supply Fan Blower Option On Constant Air volume (CAV) models, the supply air blower will provide a constant volume of air. Single Zone VAV Supply Fan option models utilize a Variable Frequency Drive (VFD) to stage the supply air blower airflow. The VFD alters the frequency and voltage of the power supply to the blower to control blower speed. The supply air blower has two speeds:. Low speed for part-load cooling operation. NOTE - Low speed is 66% of high speed.. High speed for full load cooling and all heat modes. Full speed blower operation is set by adjusting the motor pulley to deliver the desired air volume. The ventilation speed is selectable between high and low speed. NOTE - Part load airflow in cooling mode on Single Zone VAV Supply Fan models should not be set below 0 cfm/nominal full load ton to reduce the risk of evaporator coil freeze-up. The VFD has an operational range of -40 to 5 F outdoor air ambient temperature. Lower operating costs are obtained when the blower is operated on lower speeds. Single Zone VAV Supply Fan Sequence of Operation Ventilation speed is determined by the VENT SPEED switch setting on VFD control board (LO or HI). Blower operates in low speed for mechanical cooling (Y). Blower operates in high speed for any other mode (free cooling, mechanical cooling Y+Y, and heating). Economizer damper minimum position is fully closed in unoccupied mode. In occupied mode, the economizer damper minimum position is determined by the setting of the two potentiometers on VFD control board. LO SPD MIN POS potentiometer sets the minimum position when blower is operating at low speed. HI SPD MIN POS potentiometer sets the minimum position when blower is operating at high speed. Ordering Information Specify standard or high efficiency blower motor, motor horsepower and drive kit number when base unit is ordered, see Drive Kit Specifications Table. OPTIONS/ACCESSORIES Field Installed VFD Manual Bypass Kit VFD Manual Bypass Control is available as a kit for Single Zone VAV Supply Fan option. The VFD Manual Bypass Control is a manual bypass and is enabled by re-configuring the wiring on the unit. J CONTROLS Unit Control All control voltage is provided via a 4V (secondary) transformer with built-in circuit breaker protection. Heat/Cool Staging - Capable of up to heat / cool staging with a third party DDC control system or thermostat. Low Voltage Terminal Block - Provides screw terminal connections for thermostat or controller wiring. Night Setback Mode - Saves energy by closing outdoor air dampers and operating supply fan on thermostat demand only. OPTIONS/ACCESSORIES Field Installed Smoke Detector Photoelectric type, installed in supply air section, return air section or both sections. Available with power board and single sensor (supply or return) or power board and two sensors (supply and return). Power board located in unit control compartment. K-Series Packaged Gas / Electric to 5 Ton / Page 6

K FEATURES AND BENEFITS ELECTRICAL All units include terminal block and fuse block in power entry junction box for single power entry application. REQUIRED SELECTIONS Voltage Choice Specify when ordering base unit. OPTIONS/ACCESSORIES Factory or Field Installed Disconnect Switch Accessible from outside of unit, spring loaded weatherproof cover furnished. GFI Service Outlets () 5V ground fault circuit interrupter (GFCI) type, non-powered, fieldwired. Field Installed GFI Weatherproof Cover Single-gang cover. Heavy-duty UV-resistant polycarbonate case construction. Hinged base cover with gasket. Phase Monitor Phase monitor detects the phasing of incoming power. If the incoming power is out of phase or if any of the three phases are lost, an indicator LED on the phase monitor will turn red and the unit will not start. In normal operation with correct incoming power phasing, the LED will be green. NOTE - Phase Monitor is factory Installed in the control compartment on all units equipped with the Single Zone VAV Supply Fan option. L INDOOR AIR QUALITY Air Filters Disposable inch filters furnished as standard. OPTIONS/ACCESSORIES Field Installed High Efficiency Air Filters Disposable MERV 8 or MERV (Minimum Efficiency Reporting Value based on ASHRAE 5.) efficiency inch pleated filters. UVC Germicidal Lamps Germicidal lamps emit ultra-violet (UV-C) energy, which has been proven to be effective in reducing microbes such as viruses, bacteria, yeasts, and molds. This process either destroys the organism or controls its ability to reproduce. UV-C energy greatly reduces the growth and proliferation of mold and other bioaerosols (bacteria and viruses) on illuminated surfaces (particularly coil and drain pan). Lamps are field installed in the blower/evaporator coil section. All necessary hardware for installation is included. Lamps operate on 08/0V power supply. Step-down transformer must be field supplied when used with 460V and 575V rooftop units. Magnetic safety interlock terminates power when access panels are removed. Approved by ETL. Indoor Air Quality (CO ) Sensors Monitors CO levels, reports to the Unit Controller which adjusts economizer dampers as needed. SERVICEABILITY Designed to streamline general maintenance and decrease troubleshooting time. Marked & Color-Coded Wiring All electrical wiring is color-coded and marked to identify which components it is connecting. Electrical Plugs Positive connection electrical plugs are used to connect common accessories or maintenance parts for easy removal or installation. Access Panels Large access panels are provided for quick and easy access to maintenance areas. Blower Access Supply air blower parts are located near the access door for easy servicing and adjustment. Thermal Expansion Valve Access Thermal expansion valves are located near the perimeter of the unit for easier access. Removable element head allows change out of element and bulb without removing the TXV. Coil Cleaning Slab condenser coils provided for easier cleaning. Standard Components A large number of common maintenance parts are standard throughout the entire range of sizes (-5 tons), reducing the need to carry a lot of different parts to the job or maintain in inventory. Compressor Compartment Compressors are located near the perimeter of the unit for easier access. Compressors are isolated from the condenser airflow allowing system operation checks to be done without changing the airflow across the outdoor coils. K-Series Packaged Gas / Electric to 5 Ton / Page 7

M ECONOMIZER/EXHAUST OPTIONS Factory or Field Installed N OPTIONS / ACCESSORIES Economizer - Downflow or Horizontal With Outdoor Air Hood Parallel gear-driven action return air and outdoor air dampers, plug-in connections to unit, nylon bearings, neoprene seals, 4-volt, fully-modulating, spring return motor, adjustable minimum damper position. Outdoor air hood with mist elimination filter is furnished. Single sensible control is furnished with economizer. Outdoor air temperature sensor enables economizer if the outdoor temperature is less than the setpoint of the control. Outdoor Air Hood is included when economizer is factory installed and is furnished with economizer when ordered for field installation. Single Economizer Enthalpy Control Enthalpy sensor enables the economizer when the outdoor air enthalpy is below the configured setpoint. Field Installed Differential (Dual) Economizer Enthalpy Control Order two single, enthalpy control kits. One is field installed in the return air section, the other in the outdoor air section. Allows the economizer control board to select between outdoor air or return air, whichever has lower enthalpy. Downflow Barometric Relief Dampers With Exhaust Hood Allow relief of excess air. Aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle. Exhaust hood with bird screen is furnished. O Horizontal Barometric Relief Dampers With Exhaust Hood For use when unit is configured for horizontal applications requiring an economizer. Allows relief of excess air Aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle. Field installed in return air duct. Exhaust hood with bird screen is furnished. Fan Installs internal to unit for downflow applications only with economizer option. Provides exhaust air pressure relief. Interlocked to run when supply air blower is operating, fan runs when outdoor air dampers are 50% open (adjustable), motor is overload protected. Requires Economizer with Outdoor Air Hood and Downflow Barometric Relief Dampers. Dual fans are 0 in. diameter with 5 blades with () / hp motors. OUTDOOR AIR OPTIONS Factory or Field Installed Outdoor Air Damper - Downflow or Horizontal With Air Hood Linked mechanical dampers, 0 to 5% (fixed) outdoor air adjustable, installs in unit. Includes outdoor air hood. Automatic model features fully modulating spring return damper motor with plug-in connection. Manual model features parallel blade, gear-driven dampers with adjustable fixed position. Outdoor Air Hood is included when damper is factory installed and is furnished with damper when ordered for field installation. ROOF CURBS Nailer strip furnished, mates to unit, US National Roofing Contractors Approved, shipped knocked down. Downflow Clip Curbs - Uses interlocking tabs to fasten corners together. No tools required. Standard Curbs - Curb corners fasten together with furnished hardware. Adjustable Pitched Curb - Curbs are regionally sourced. Dimensions will vary based upon the source. Contact your Lennox sales representative for a detailed cut sheet with applicable dimensions. Horizontal Converts unit from downflow to horizontal (side) air flow, return air is on unit, supply air is on curb, see dimension drawings. Curbs for rooftop applications meet National Roofing Code requirements. Requires Horizontal Return Air Panel Kit. Available in 6, 0, 7 and 4 inch heights. Optional Insulation Kit is available to help prevent sweating. CEILING DIFFUSERS Ceiling Diffusers (Flush or Step-Down) Aluminum grilles, large center grille, insulated diffuser box with flanges, hanging rings furnished, interior transition (even air flow), internally sealed (prevents recirculation), adapts to T-bar ceiling grids or plaster ceilings. Transitions (Supply and Return) Used with diffusers, installs in roof curb, galvanized steel construction, flanges furnished for duct connection to diffusers, fully insulated. K-Series Packaged Gas / Electric to 5 Ton / Page 8

OPTIONS / ACCESSORIES - STANDARD EFFICIENCY MODELS Item Description Model Number Catalog Number 80S 0S 40S 00S COOLING SYSTEM Condensate Drain Trap PVC - CTRAP0AD 76W6 X X X X Copper - CTRAP0AD 76W7 X X X X Corrosion Protection Factory O O O O Drain Pan Overflow Switch CSNSR7FF- 0C4 X X X X Efficiency Standard O O O O Low Ambient Kit (Includes Compressor Crankcase Heater) 08/0V-ph - KLOAM0*C0Y 0A9 X 460V-ph - KLOAM0*C0G 0A9 X 575V-ph - KLOAM0*C0J 0A9 X 08/0V-ph - KLOAM0*C0Y 0A94 X X X 460V-ph - KLOAM0*C0G 0A95 X X X 575V-ph - KLOAM0*COJ 0A96 X X X Refrigerant Type R-40A O O O O HEATING SYSTEM Bottom Gas Piping Kit CGPKT0C- 85M X X X X Combustion Air Intake Extensions (order two) LTACAIK0/5 89L97 X X X X Gas Heat Input Standard - 60,000 Btuh Factory O O O O Medium - 60,000 Btuh Factory O O O O High - 480,000 Btuh Factory O O O O Low Vestibule Heater 08/0V-ph - CLTVH0C-Y 58W8 X X X X 460V - CLTVH0C-G 58W9 X X X X 575V - CLTVH0C-J 58W0 X X X X LPG/Propane Conversion Kits (Order kits) Standard heat - LTALPGK-0 7M94 X X X X Medium heat - LTALPGK-80 7M95 X X X X High heat - LTALPGK-40 7M96 X X X X Stainless Steel Heat Exchanger Factory O O O O Vertical Vent Extension Kit (Order two kits) CEXTN0FF 4W6 X X X X BLOWER - SUPPLY AIR Blower Option CAV (Constant Air Volume) Factory O O O O Single Zone VAV Supply Factory O O O O Motors - Constant Air Volume (CAV) Belt Drive (standard efficiency) - hp Factory O O Belt Drive (standard efficiency) - 5 hp Factory O O O O Belt Drive (standard efficiency) - 7.5 hp Factory O O O O Belt Drive (standard efficiency) - 0 hp Factory O O Motors - Single Zone VAV Supply Belt Drive (standard efficiency) - hp Factory O O Belt Drive (standard efficiency) - 5 hp Factory O O O O Belt Drive (standard efficiency) - 7.5 hp Factory O O O O Belt Drive (standard efficiency) - 0 hp Factory O O VFD Manual Bypass Kit (for Single Zone VAV Supply equipped units) Drive Kits See Blower Data Tables for usage and selection, 5 hp (08/0V) KVFDBC- 90W5 X X X X, 5, 7.5, 0 hp (460V and 575V) 7.5 hp, 0 hp (08/0V) KVFDB0C- 90W5 X X X X Kit # 55-75 rpm Factory O O Kit # 70-965 rpm Factory O O Kit # 685-856 rpm Factory O O O O Kit #4 850-045 rpm Factory O O O O Kit #5 945-85 rpm Factory O O O O Kit #6 850-045 rpm Factory O O O O Kit #7 945-85 rpm Factory O O O O Kit #8 045-85 rpm Factory O O O O Kit #0 045-85 rpm Factory O O Kit # 5-65 rpm Factory O O CABINET Coil Guards EGARDC 98W76 X X EGARDC 9W7 X X Hail Guards EGARDC 98W77 X X EGARDC 9W6 X X NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed K-Series Packaged Gas / Electric to 5 Ton / Page 9

OPTIONS / ACCESSORIES - STANDARD EFFICIENCY MODELS Item Description CONTROLS Model Number Catalog Number 80S 0S 40S 00S BACnet KOCTRLB- 96W5 OX OX OX OX BACnet Thermostat with Display KOSNSR0FF 97W X X X X BACnet Thermostat without Display KOSNSR00FF 97W4 X X X X Plenum Cable (75 ft.) KOMISC00FF 97W5 X X X X Smoke Detector - Supply or Return (Power board and one sensor) CSNSR44C- 8W40 X X X X Smoke Detector - Supply and Return (Power board and two sensors) CSNSR4C- 8W4 X X X X ELECTRICAL Voltage 60 hz 08/0V - phase Factory O O O O 460V - phase Factory O O O O 575V - phase Factory O O O O Disconnect Switch (see Electric Heat Tables for usage) 80 amp - CDISC080C- 54W85 OX OX OX OX 50 amp - CDISC50C- 54W86 OX OX OX OX 50 amp - CDISC50C- 54W87 OX OX OX OX GFI Service 5 amp non-powered, field-wired (08/0V, 460V only) LTAGFIK0/5 74M70 OX OX OX OX Outlets 0 amp non-powered, field-wired (575V only) CGFCI0FF 67E0 X X X X Weatherproof Cover for GFI CGFCI99FF 0C89 X X X X Phase Monitor CPHZM0FF- 0C5 X X X X INDOOR AIR QUALITY Air Filters High Efficiency Air Filters MERV 8 - CFLTR5C-- 54W67 X X X X 4 x 4 x (Order 6 per unit) MERV - CFLTR40C-- 5W40 X X X X Replacement Media Filter With Metal Mesh CFLTR0C-- 44N6 X X X X Frame (includes non-pleated filter media) Indoor Air Quality (CO ) Sensors Sensor - Wall-mount, off-white plastic cover with LCD display C0SNSR50AEL 77N9 X X X X Sensor - Wall-mount, off-white plastic cover, no display C0SNSR5AEL 87N5 X X X X Sensor - Black plastic case with LCD display, rated for plenum C0SNSR5AEL 87N5 X X X X mounting Sensor - Wall-mount, black plastic case, no display, rated for C0MISC9AE 87N54 X X X X plenum mounting CO Sensor Duct Mounting Kit - for downflow applications C0MISC9AE- 85L4 X X X X Aspiration Box - for duct mounting non-plenum rated CO sensors C0MISC6AE- 90N4 X X X X (87N5 or 77N9) UVC Germicidal Light Kit UVC Light Kit (0/0V-ph) CUVCL0C- 54W65 X X X X ECONOMIZER Economizer Economizer - Downflow or Horizontal KECON0C- 54W77 OX OX OX OX (Outdoor Air Hood furnished) Economizer Controls Differential Enthalpy Order - CSNSR64FF 5W64 X X X X Single Enthalpy CSNSR64FF 5W64 OX OX OX OX Downflow Barometric Relief Dampers Barometric Relief Dampers with Exhaust Hood CDAMP50C 54W78 OX OX OX OX Horizontal Barometric Relief Dampers Barometric Relief Dampers with Exhaust Hood LAGEDH8/4 6K99 X X X X Factory installed on all Single Zone VAV Supply Fan equipped units. Lamps operate on 0-0V single-phase power supply. Step-down transformer must be field supplied for field installation in 460V and 575V rooftop units (transformer is furnished for factory installed light kits). Alternately, a separate 0V power supply may be used to directly power the UVC ballast(s) NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed K-Series Packaged Gas / Electric to 5 Ton / Page 0

OPTIONS / ACCESSORIES - STANDARD EFFICIENCY MODELS Item Description Model Number Catalog Number 80S 0S 40S 00S OUTDOOR AIR Outdoor Air Dampers Motorized Dampers with Outdoor Air Hood KDAMP0C- 58W6 OX OX OX OX Manual Dampers With Outdoor Air Hood CDAMP0C- 54W76 OX OX OX OX POWER EXHAUST (downflow applications only) Standard Static 08/0V - CPWREC-Y 75W90 X X X X 460V - CPWREC-G 75W9 X X X X 575V - CPWREC-J 75W9 X X X X ROOF CURBS - DOWNFLOW Clip Curb 8 in. height CCURB40CD 6W X X X X 4 in. height LARMF8/0S-4 K44 X X X X 8 in. height LARMF8/0S-8 K45 X X X X 4 in. height LARMF8/0S-4 K46 X X X X Standard 4 in. height LARMF8/6-4 6K87 X X X X 4 in. height LARMF8/6-4 6K88 X X X X Adjustable Pitched Curb 4 in. height LCURB55C 4W6 X X X X ROOF CURBS - HORIZONTAL (REQUIRES HORIZONTAL RETURN AIR PANEL KIT) Standard 6 in. height - slab applications LARMFH8/4-6 97J X X X 7 in. height - rooftop applications LARMFH8/4-7 8K5 X X X 0 in. height - slab applications LARMFH0/6-0 K79 X 4 in. height - rooftop applications LARMFH0/6-4 8K54 X Insulation Kit For Standard Horizontal Curbs for LARMFH8/4-6 CINSUC-- 7K X X X for LARMFH8/4-7 CINSUC-- 7K4 X X X for LARMFH0/6-0 CINSUC-- 7K X for LARMFH0/6-4 CINSU4C-- 7K5 X Horizontal Return Air Panel Kit Required for Horizontal Applications with Roof Curb CHRAP0C-- 87M00 X X X X CEILING DIFFUSERS Step-Down - Order one RTD-85 9G06 X RTD-75-R 9G07 X X X Flush - Order one FD-85 9G0 X FD-75-R 9G X X X Transitions (Supply and Return) - Order one LASRT8 9K0 X LASRT/4 9K0 X X X NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed K-Series Packaged Gas / Electric to 5 Ton / Page

OPTIONS / ACCESSORIES - HIGH EFFICIENCY MODELS Item Description K-Series Packaged Gas / Electric to 5 Ton / Page Model Number Catalog 56H 80H 0H 40H 00H Number COOLING SYSTEM Condensate Drain Trap PVC - CTRAP0AD 76W6 X X X X X Copper - CTRAP0AD 76W7 X X X X X Corrosion Protection Factory O O O O O Drain Pan Overflow Switch CSNSR7FF- 0C4 X X X X X Efficiency High O O O O O Low Ambient Kit (Includes Compressor Crankcase Heater) 08/0V-ph - KLOAM0*C0Y 0A94 X X X 460V-ph - KLOAM0*C0G 0A95 X X X 575V-ph - KLOAM0*C0J 0A96 X X X 08/0V-ph - KLOAM04*C0Y 0A97 X X 460V-ph - KLOAM04*C0G 0A98 X X 575V-ph - KLOAM04*COJ 0A99 X X Refrigerant Type R-40A O O O O O HEATING SYSTEM Bottom Gas Piping Kit CGPKT0C- 85M X X X X X Combustion Air Intake Extensions (order two) LTACAIK0/5 89L97 X X X X X Gas Heat Input Standard - 60,000 Btuh Factory O O O O O Medium - 60,000 Btuh Factory O O O O O High - 480,000 Btuh Factory O O O O Low Vestibule Heater 08/0V-ph - CLTVH0C-Y 58W8 X X X X X 460V - CLTVH0C-G 58W9 X X X X X 575V - CLTVH0C-J 58W0 X X X X X LPG/Propane Conversion Kits (Order kits) Standard heat - LTALPGK-0 7M94 X X X X X Medium heat - LTALPGK-80 7M95 X X X X X High heat - LTALPGK-40 7M96 X X X X Stainless Steel Heat Exchanger Factory O O O O O Vertical Vent Extension Kit (Order two kits) CEXTN0FF 4W6 X X X X X BLOWER - SUPPLY AIR Blower Option CAV (Constant Air Volume) Factory O O O O O Single Zone VAV Supply Factory O O O O O Motors - Constant Air Volume (CAV) Belt Drive (standard efficiency) - hp Factory O Belt Drive (standard efficiency) - hp Factory O O O Belt Drive (standard efficiency) - 5 hp Factory O O O O O Belt Drive (standard efficiency) - 7.5 hp Factory O O O O Belt Drive (standard efficiency) - 0 hp Factory O O Motors - Single Zone VAV Supply Belt Drive (high efficiency) - hp Factory O Belt Drive (standard efficiency) - hp Factory O O O Belt Drive (standard efficiency) - 5 hp Factory O O O O O Belt Drive (standard efficiency) - 7.5 hp Factory O O O O Belt Drive (standard efficiency) - 0 hp Factory O O VFD Manual Bypass Kit,, 5 hp (08/0V) KVFDBC- 90W5 X X X X X (for Single Zone VAV Supply equipped units),, 5, 7.5, 0 hp (460V and 575V) 7.5 hp, 0 hp (08/0V) KVFDB0C- 90W5 X X X X Drive Kits See Blower Data Tables for usage and selection Kit # 55-75 rpm Factory O O O Kit # 70-965 rpm Factory O O O Kit # 685-856 rpm Factory O O O O O Kit #4 850-045 rpm Factory O O O O O Kit #5 945-85 rpm Factory O O O O O Kit #6 850-045 rpm Factory O O O O Kit #7 945-85 rpm Factory O O O O Kit #8 045-85 rpm Factory O O O O Kit #0 045-85 rpm Factory O O Kit # 5-65 rpm Factory O O CABINET Coil Guards EGARDC 98W76 X EGARDC 9W7 X X X X Hail Guards EGARDC 98W77 X EGARDC 9W6 X X X X Smoke Detector - Supply and Return (Power board and two sensors) CSNSR4C- 8W4 X X X X X NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed

OPTIONS / ACCESSORIES - HIGH EFFICIENCY MODELS Item Description Model Number Catalog 56H 80H 0H 40H 00H Number CONTROLS Commercial Controls X BACnet KOCTRLB- 96W5 OX OX OX OX OX BACnet Thermostat with Display KOSNSR0FF 97W X X X X X BACnet Thermostat without Display KOSNSR00FF 97W4 X X X X X Plenum Cable (75 ft.) KOMISC00FF 97W5 X X X X X Smoke Detector - Supply or Return (Power board and one sensor) CSNSR44C- 8W40 X X X X X ELECTRICAL Voltage 60 hz 08/0V - phase Factory O O O O O 460V - phase Factory O O O O O 575V - phase Factory O O O O O Disconnect Switch (see Electric Heat Tables for usage) 80 amp - CDISC080C- 54W85 OX OX OX OX OX 50 amp - CDISC50C- 54W86 OX OX OX OX OX 50 amp - CDISC50C- 54W87 OX OX OX OX OX GFI Service 5 amp non-powered, field-wired (08/0V, 460V only) LTAGFIK0/5 74M70 X OX OX OX OX Outlets 0 amp non-powered, field-wired (575V only) CGFCI0FF 67E0 X X X X X Weatherproof Cover for GFI CGFCI99FF 0C89 X X X X X Phase Monitor CPHZM0FF- 0C5 X X X X X INDOOR AIR QUALITY Air Filters High Efficiency Air Filters MERV 8 - CFLTR5C-- 54W67 X X X X X 4 x 4 x (Order 6 per unit) MERV - CFLTR40C-- 5W40 X X X X X Replacement Media Filter With Metal Mesh CFLTR0C-- 44N6 X X X X X Frame (includes non-pleated filter media) Indoor Air Quality (CO ) Sensors Sensor - Wall-mount, off-white plastic cover with LCD display C0SNSR50AEL 77N9 X X X X X Sensor - Wall-mount, off-white plastic cover, no display C0SNSR5AEL 87N5 X X X X X Sensor - Black plastic case with LCD display, rated for plenum C0SNSR5AEL 87N5 X X X X X mounting Sensor - Wall-mount, black plastic case, no display, rated for C0MISC9AE 87N54 X X X X X plenum mounting CO Sensor Duct Mounting Kit - for downflow applications C0MISC9AE- 85L4 X X X X X Aspiration Box - for duct mounting non-plenum rated CO sensors C0MISC6AE- 90N4 X X X X X (87N5 or 77N9) UVC Germicidal Light Kit UVC Light Kit (0/0V-ph) CUVCL0C- 54W65 X X X X X ECONOMIZER Economizer - Downflow or Horizontal KECON0C- 54W77 OX OX OX OX OX (Outdoor Air Hood furnished) Economizer Controls Differential Enthalpy Order - CSNSR64FF 5W64 X X X X X Single Enthalpy CSNSR64FF 5W64 OX OX OX OX OX Downflow Barometric Relief Dampers Barometric Relief Dampers with Exhaust Hood CDAMP50C 54W78 OX OX OX OX OX Horizontal Barometric Relief Dampers Barometric Relief Dampers with Exhaust Hood LAGEDH8/4 6K99 X X X X X OUTDOOR AIR Outdoor Air Dampers Motorized Dampers with Outdoor Air Hood KDAMP0C- 58W6 OX OX OX OX OX Manual Dampers With Outdoor Air Hood CDAMP0C- 54W76 OX OX OX OX OX POWER EXHAUST (downflow applications only) Standard Static 08/0V - CPWREC-Y 75W90 X X X X X 460V - CPWREC-G 75W9 X X X X X 575V - CPWREC-J 75W9 X X X X X Factory installed on all Single Zone VAV Supply Fan equipped units Lamps operate on 0-0V single-phase power supply. Step-down transformer must be field supplied for field installation in 460V and 575V rooftop units (transformer is furnished for factory installed light kits). Alternately, a separate 0V power supply may be used to directly power the UVC ballast(s) NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed K-Series Packaged Gas / Electric to 5 Ton / Page

OPTIONS / ACCESSORIES - HIGH EFFICIENCY MODELS Item Description Model Number Catalog 56H 80H 0H 40H 00H Number ROOF CURBS - DOWNFLOW Clip Curb 8 in. height CCURB40CD 6W X X X X X 4 in. height LARMF8/0S-4 K44 X X X X X 8 in. height LARMF8/0S-8 K45 X X X X X 4 in. height LARMF8/0S-4 K46 X X X X X Standard 4 in. height LARMF8/6-4 6K87 X X X X X 4 in. height LARMF8/6-4 6K88 X X X X X Adjustable Pitched Curb 4 in. height LCURB55C 4W6 X X X X X ROOF CURBS - HORIZONTAL (REQUIRES HORIZONTAL RETURN AIR PANEL KIT) Standard 6 in. height - slab applications LARMFH8/4-6 97J X X X X 7 in. height - rooftop applications LARMFH8/4-7 8K5 X X X X 0 in. height - slab applications LARMFH0/6-0 K79 X 4 in. height - rooftop applications LARMFH0/6-4 8K54 X Insulation Kit For Standard Horizontal Curbs for LARMFH8/4-6 CINSUC-- 7K X X X X for LARMFH8/4-7 CINSUC-- 7K4 X X X X for LARMFH0/6-0 CINSUC-- 7K X for LARMFH0/6-4 CINSU4C-- 7K5 X Horizontal Return Air Panel Kit Required for Horizontal Applications with Roof Curb CHRAP0C-- 87M00 X X X X X CEILING DIFFUSERS Step-Down - Order one RTD-85 9G06 X X RTD-75-R 9G07 X X X Flush - Order one FD-85 9G0 X X FD-75-R 9G X X X Transitions (Supply and Return) - Order one LASRT8 9K0 X X LASRT/4 9K0 X X X NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed K-Series Packaged Gas / Electric to 5 Ton / Page 4

SPECIFICATIONS - STANDARD EFFICIENCY MODELS General Data Nominal Tonnage 5 Ton 5 Ton 7.5 Ton 7.5 Ton Model Number KGA80S4B KGA80S4M KGA0S4B KGA0S4M Efficiency Type Standard Standard Standard Standard Blower Type Constant Air Volume (CAV) Single Zone VAV Supply Fan Constant Air Volume (CAV) Single Zone VAV Supply Fan Cooling Performance Gross Cooling Capacity - Btuh 8,000 8,000 04,000 04,000 Net Cooling Capacity - Btuh 76,000 76,000 98,000 98,000 AHRI Rated Air Flow - cfm 5750 5750 65 65 Unit Power - kw 6. 6. 8.4 8.4 EER (Btuh/Watt) 0.8 0.8 0.8 0.8 IEER (Btuh/Watt).0.6.0. Refrigerant Type R-40A R-40A R-40A R-40A Refrigerant Charge Furnished Circuit 7 lbs. 8 oz. 7 lbs. 8 oz. 5 lbs. oz. 5 lbs. oz. Circuit 7 lbs. 8 oz. 7 lbs. 8 oz. 5 lbs. 8 oz. 5 lbs. 8 oz. Circuit - - - - - - 5 lbs. 8 oz. 5 lbs. 8 oz. Gas Heat Available See page 0 Compressor Type (number) Scroll () Scroll () Scroll () Scroll () Outdoor Net face area (total) - sq. ft. 4.4 4.4 4.4 4.4 Coils Number of rows Fins per inch Outdoor Coil Fans Motor - (No.) horsepower () / () / () / () / Motor rpm 075 075 075 075 Motor watts 00 00 00 00 Diameter - (No.) in. () 4 () 4 () 4 () 4 Number of blades Air volume - cfm,000,000,000,000 Indoor Coils Net face area (total) - sq. ft. 8.6 8.6.4.4 Tube diameter - in. /8 /8 /8 /8 Number of rows Fins per inch 4 4 4 4 Drain connection - No. and size () in. FPT () in. FPT () in. FPT () in. FPT Expansion device type Refrigerant Metering Orifice (RFC) Indoor Blower and Drive Selection Nominal motor output Maximum usable motor output (US Only) Motor - Drive kit number hp, 5 hp, 7.5 hp.45 hp, 5.75 hp, 8.6 hp hp Kit 55-75 rpm Kit 70-965 rpm 5 hp Kit 685-856 rpm Kit 4 850-045 rpm Kit 5 945-85 rpm 7.5 hp Kit 6 850-045 rpm Kit 7 945-85 rpm Kit 8 045-85 rpm () 5 x 5 () 5 x 5 () 5 x 5 () 5 x 5 Blower wheel nominal diameter x width - in. Filters Type of filter Fiberglass, disposable Number and size - in. (6) 4 x 4 x Electrical characteristics 08/0V, 460V or 575V - 60 hertz - phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. AHRI Certified to AHRI Standard 40/60; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air; minimum external duct static pressure. Integrated Energy Efficiency Ratio tested according to AHRI Standard 40/60. Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. NOTE Units equipped with Single Zone VAV Supply Fan option are limited to a motor service factor of.0. K-Series Packaged Gas / Electric to 5 Ton / Page 5

SPECIFICATIONS - STANDARD EFFICIENCY MODELS General Data Nominal Tonnage 0 Ton 0 Ton 5 Ton 5 Ton Model Number KGA40S4B KGA40S4M KGA00S4B KGA00S4M Efficiency Type Standard Standard Standard Standard Blower Type Constant Air Volume (CAV) Single Zone VAV Supply Fan Constant Air Volume (CAV) Single Zone VAV Supply Fan Cooling Performance Gross Cooling Capacity - Btuh 8,000 8,000 8,000 8,000 Net Cooling Capacity - Btuh 8,000 8,000 70,000 70,000 AHRI Rated Air Flow - cfm 7700 7700 8750 8750 Unit Power - kw.. 7.0 7.0 EER (Btuh/Watt) 0.8 0.8 0.0 0.0 IEER (Btuh/Watt).0.0 0.0.0 Refrigerant Type R-40A R-40A R-40A R-40A Refrigerant Charge Furnished Circuit 7 lbs. 4 oz. 7 lbs. 4 oz. 7 lbs. 4 oz. 7 lbs. 4 oz. Circuit 7 lbs. 4 oz. 7 lbs. 4 oz. 7 lbs. 4 oz. 7 lbs. 4 oz. Circuit 6 lbs. 4 oz. 6 lbs. 4 oz. 6 lbs. 4 oz. 6 lbs. 4 oz. Gas Heat Available See page 0 Compressor Type (number) Scroll () Scroll () Scroll () Scroll () Outdoor Net face area (total) - sq. ft. 55. 55. 55. 55. Coils Number of rows Fins per inch Outdoor Coil Fans Motor - (No.) horsepower (4) / (4) / (4) / (4) / Motor rpm 075 075 075 075 Motor watts 500 500 500 500 Diameter - (No.) in. (4) 4 (4) 4 (4) 4 (4) 4 Number of blades Air volume - cfm 6,000 6,000 6,000 6,000 Indoor Coils Net face area (total) - sq. ft..4.4.4.4 Tube diameter - in. /8 /8 /8 /8 Number of rows 4 4 4 4 Fins per inch 4 4 4 4 Drain connection - No. and size () in. FPT () in. FPT () in. FPT () in. FPT Expansion device type Refrigerant Metering Orifice (RFC) Indoor Blower and Drive Selection Nominal motor output Maximum usable motor output (US Only) Motor - Drive kit number 5 hp, 7.5 hp, 0 hp 5.75 hp, 8.6 hp,.5 hp 5 hp Kit 685-856 rpm Kit 4 850-045 rpm Kit 5 945-85 rpm 7.5 hp Kit 6 850-045 rpm Kit 7 945-85 rpm Kit 8 045-85 rpm 0 hp Kit 7 945-85 rpm Kit 0 045-85 rpm Kit 5-65 rpm () 5 x 5 () 5 x 5 () 5 x 5 () 5 x 5 Blower wheel nominal diameter x width - in. Filters Type of filter Fiberglass, disposable Number and size - in. (6) 4 x 4 x Electrical characteristics 08/0V, 460V or 575V - 60 hertz - phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. AHRI Certified to AHRI Standard 40/60; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air; minimum external duct static pressure. Integrated Energy Efficiency Ratio tested according to AHRI Standard 40/60. Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. NOTE Units equipped with Single Zone VAV Supply Fan option are limited to a motor service factor of.0. K-Series Packaged Gas / Electric to 5 Ton / Page 6

SPECIFICATIONS - HIGH EFFICIENCY MODELS General Data Nominal Tonnage Ton Ton 5 Ton 5 Ton Model Number KGA56H4B KGA56H4M KGA80H4B KGA80H4M Efficiency Type High High High High Blower Type Constant Air Volume (CAV) Single Zone VAV Supply Fan Constant Air Volume (CAV) Single Zone VAV Supply Fan Cooling Performance Gross Cooling Capacity - Btuh 56,000 56,000 76,000 76,000 Net Cooling Capacity - Btuh 5,000 5,000 7,000 7,000 AHRI Rated Air Flow - cfm 500 500 550 550 Unit Power - kw.7.7 4. 4. EER (Btuh/Watt).0.0.0.0 IEER (Btuh/Watt).6 4..5.7 Refrigerant Type R-40A R-40A R-40A R-40A Refrigerant Charge Furnished Circuit 5 lbs. oz. 5 lbs. oz. 6 lbs. 0 oz. 6 lbs. 0 oz. Circuit 5 lbs. 6 oz. 5 lbs. 6 oz. 5 lbs. 0 oz. 5 lbs. 0 oz. Circuit 5 lbs. 0 oz. 5 lbs. 0 oz. 5 lbs. 4 oz. 5 lbs. 4 oz. Gas Heat Available See page 0 Compressor Type (number) Scroll () Scroll () Scroll () Scroll () Outdoor Net face area (total) - sq. ft. 4.4 4.4 55. 55. Coils Number of rows Fins per inch Outdoor Coil Fans Motor - (No.) horsepower () / () / (4) / (4) / Motor rpm 075 075 075 075 Motor watts 00 00 500 500 Diameter - (No.) in. () 4 () 4 (4) 4 (4) 4 Number of blades Air volume - cfm,000,000 6,000 6,000 Indoor Coils Net face area (total) - sq. ft..4.4.4.4 Tube diameter - in. /8 /8 /8 /8 Number of rows Fins per inch 4 4 4 4 Drain connection - No. and size () in. FPT () in. FPT () in. FPT () in. FPT Expansion device type Balanced port TXV, removable head Indoor Blower and Drive Selection Nominal motor output hp, hp, 5 hp hp, 5 hp, 7.5 hp Maximum usable motor. hp,.45 hp, 5.75 hp.45 hp, 5.75 hp, 8.6 hp output (US Only) Motor - Drive kit number hp Kit 55-75 rpm Kit 70-965 rpm hp Kit 55-75 rpm Kit 70-965 rpm 5 hp Kit 685-856 rpm Kit 4 850-045 rpm Kit 5 945-85 rpm hp Kit 55-75 rpm Kit 70-965 rpm 5 hp Kit 685-856 rpm Kit 4 850-045 rpm Kit 5 945-85 rpm 7.5 hp Kit 6 850-045 rpm Kit 7 945-85 rpm Kit 8 045-85 rpm Blower wheel nominal diameter x width - in. () 5 x 5 () 5 x 5 () 5 x 5 () 5 x 5 Filters Type of filter Fiberglass, disposable Number and size - in. (6) 4 x 4 x Electrical characteristics 08/0V, 460V or 575V - 60 hertz - phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. AHRI Certified to AHRI Standard 40/60; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air; minimum external duct static pressure. Integrated Energy Efficiency Ratio tested according to AHRI Standard 40/60. Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. NOTE Units equipped with Single Zone VAV Supply Fan option are limited to a motor service factor of.0. K-Series Packaged Gas / Electric to 5 Ton / Page 7

SPECIFICATIONS - high EFFICIENCY MODELS General Data Nominal Tonnage 7.5 Ton 7.5 Ton 0 Ton 0 Ton Model Number KGA0H4B KGA0H4M KGA40H4B KGA40H4M Efficiency Type High High High High Blower Type Constant Air Volume (CAV) Single Zone VAV Supply Fan Constant Air Volume (CAV) Single Zone VAV Supply Fan Cooling Performance Gross Cooling Capacity - Btuh 04,000 04,000 8,000 8,000 Net Cooling Capacity - Btuh 98,000 98,000 0,000 0,000 AHRI Rated Air Flow - cfm 65 65 6400 6400 Unit Power - kw 6.5 6.5 9. 9. EER (Btuh/Watt).0.0.0.0 IEER (Btuh/Watt).0 4.0. 4.5 Refrigerant Type R-40A R-40A R-40A R-40A Refrigerant Charge Furnished Circuit 6 lbs. oz. 6 lbs. oz. 6 lbs. 4 oz. 6 lbs. 4 oz. Circuit 6 lbs. 4 oz. 6 lbs. 4 oz. 6 lbs. oz. 6 lbs. oz. Circuit 6 lbs. 4 oz. 6 lbs. 4 oz. 5 lbs. 4 oz. 5 lbs. 4 oz. Circuit 4 - - - - - - 5 lbs. 6 oz. 5 lbs. 6 oz. Gas Heat Available See page 0 Compressor Type (number) Scroll () Scroll () Scroll (4) Scroll (4) Outdoor Net face area (total) - sq. ft. 55. 55. 55. 55. Coils Number of rows Fins per inch Outdoor Coil Fans Motor - (No.) horsepower (6) / (6) / (6) / (6) / Motor rpm 075 075 075 075 Motor watts 950 950 950 950 Diameter - (No.) in. (6) 4 (6) 4 (6) 4 (6) 4 Number of blades Air volume - cfm 0,000 0,000 0,000 0,000 Indoor Coils Net face area (total) - sq. ft..4.4.4.4 Tube diameter - in. /8 /8 /8 /8 Number of rows 4 4 4 4 Fins per inch 4 4 4 4 Drain connection - No. and size () in. FPT () in. FPT () in. FPT () in. FPT Expansion device type Balanced port TXV, removable head Indoor Blower and Drive Selection Nominal motor output hp, 5 hp, 7.5 hp 5 hp, 7.5 hp, 0hp Maximum usable motor.45 hp, 5.75 hp, 8.6 hp 5.75 hp, 8.6 hp,.5 hp output (US Only) Motor - Drive kit number hp Kit 55-75 rpm Kit 70-965 rpm 5 hp Kit 685-856 rpm Kit 4 850-045 rpm Kit 5 945-85 rpm 7.5 hp Kit 6 850-045 rpm Kit 7 945-85 rpm Kit 8 045-85 rpm 5 hp Kit 685-856 rpm Kit 4 850-045 rpm Kit 5 945-85 rpm 7.5 hp Kit 6 850-045 rpm Kit 7 945-85 rpm Kit 8 045-85 rpm 0 hp Kit 7 945-85 rpm Kit 0 045-85 rpm Kit 5-65 rpm Blower wheel nominal diameter x width - in. () 5 x 5 () 5 x 5 () 5 x 5 () 5 x 5 Filters Type of filter Fiberglass, disposable Number and size - in. (6) 4 x 4 x Electrical characteristics 08/0V, 460V or 575V - 60 hertz - phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. AHRI Certified to AHRI Standard 40/60; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air; minimum external duct static pressure. Integrated Energy Efficiency Ratio tested according to AHRI Standard 40/60. Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. NOTE Units equipped with Single Zone VAV Supply Fan option are limited to a motor service factor of.0. K-Series Packaged Gas / Electric to 5 Ton / Page 8