DPL/DPL-AF SERIES PLENUM FANS OPERATION INSTRUCTIONS AND PARTS MANUAL MODELS: DPL/DPL-AF-12, 13, 15, 16, 18, 20, 22, 24, 27, 30, 33, 36 GENERAL SAFETY

Similar documents
Ø5/16" HOLES FOR FASTENING TO CURB

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

Installation, Operation and Maintenance Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH

Installation, Operation and Maintenance Manual

Emergency Smoke Control Centrifugal Roof Exhaust Fans

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST

DESIGN GUIDELINES FANS PAGE 1 of 7

SECTION AXIAL HVAC FANS

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

SECTION CENTRIFUGAL HVAC FANS

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

MODEL CLS Centrifugal Filtered Supply Fans

Tubular Centrifugal Inline Fans TCN

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

BLOWER PARTS & ACCESSORIES

K SERIES SIDEWALL PROPELLER FANS

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

200, 9200 & 9200-VIB SERIES

Twin City Fan & Blower

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

Operation and Maintenance Manual. Series BI Centrifugal Blowers

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

NSGV Direct Drive Pressure Blower (AF) Aluminum Housing & Wheel

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Duct Blower Cabinet Fans

CPL Centrifugal Plenum Fans

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

VANEAXIAL & TUBEAXIAL FANS

SECTION HVAC POWER VENTILATORS

TMX Mixed Flow Inline INSTALLATION, OPERATION AND MAINTENANCE MANUAL

HOOD EXHAUST OR SUPPLY PROPELLER FAN

READ AND SAVE THESE INSTRUCTIONS. Installation Operation and Maintenance Manual

OPERATION & MAINTENANCE INSTRUCTIONS CONTROLLABLE PITCH VANE AXIAL FANS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL CNW DHK PVK

Turning Air Into Solutions. PLUG FANS TYPE BCPL

D-Series Blowers and Exhausters

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

User s Manual D-Series Blowers and Exhausters

Inline Fans [ 14 ] * UL is optional and must be specified.

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

SQUARE INLINE CENTRIFUGAL FANS

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Fixed Pitch Vane Axial Fan

for Untempered - Make-Up Air Units

TSL and QSL Inline Centrifugal and Mixed Flow Fans

COMMERCIAL DUTY PLENUM FANS

TUBULAR CENTRIFUGAL INLINE FANS

SQI Centrifugal Square Inline Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

THE GIANT-VAC PTO BLOWER MODELS 2000*/3200**/4000***

BLISS PELLET MILL 200

DUCT BLOWER Cabinet Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Table of Contents. Document Centrifugal Utility Fans. Model SWB - Series 100, 200 and 300 Models SFB, SFD, SWB and SWD. Model SWB Series 200

Installation, Operation and Maintenance Manual

Centrifugal Upblast Power Roof Ventilators

IMPORTANT! READ BEFORE PROCEEDING! PAF Axial Propeller Fans

IM Centrifugal Power Roof & Wall Ventilators. Introduction. Shipment and Receiving. Handling. Storage. Issue Date: 4-97 Rev.

INSTALLATION MANUAL TBH/TBV BELT DRIVE BLOWER-COIL UNITS HORIZONTAL. Redefine your comfort zone.

Twin City Fan & Blower

AT Clutch Major Service Sizes 25, 55, 115

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

COYOTE ENTERPRISES, INC. 9/10 BLAST WHEEL MAINTENANCE & ASSEMBLY MANUAL

Support Units. FA Units

WELDING FUME EXHAUSTERS & ARMS

Advanced Technology Tension Clutches

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

IM-210 INSTALLATION MAINTENANCE, OPERATING INSTRUCTIONS HOODED ROOF VENTILATORS UPBLAST ROOF VENTILATORS AIR PRESSURE AND SUCTION A WORD ABOUT SAFETY

Auger Belt Tension Adjustment DB7659

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

CCP Centrifugal Plug Fans

INSTALLATION, OPERATION & MAINTENANCE MANUAL Hooded Propeller & Tubeaxial Roof Fans. Models: LHB, LHD, LHBF, LHDF, THB, THD, THBF, THDF

Propeller Fan BE Series

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

INSTALLATION, OPERATION & MAINTENANCE MANUAL. Centrifugal Square Inline Fans

REBEL/AQ/SEP/ETE/ETS IO&M

Advantage Fan 36" and 48"

INSTALLATION AND MAINTENANCE MANUAL

Step-by-Step Instructions for ieq45 R.A. Worm Installation/Replacing September 2013

Twin City Fan & Blower

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

Transcription:

DPL/DPL-AF SERIES PLENUM FANS OPERATION INSTRUCTIONS AND PARTS MANUAL MODELS: DPL/DPL-AF-12, 13, 15, 16, 18, 20, 22, 24, 27, 30, 33, 36 GENERAL SAFETY Rotating parts on fans should not be exposed. Where these components are not protected by ductwork, cabinets or covers, appropriate guards should be employed to restrict exposure to rotating parts. Access doors should not be opened with the fan operating to avoid foreign objects being drawn into the system. On initial start-up a careful inspection should be carried out to ensure no foreign material is present which could become airborne in the system. Read installation and operation instructions carefully before attempting to install, operate or service Delhi DPL/DPL-AF Series Blowers. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference. MODEL MAX. H.P SHAFT DIA. WEIGHT DPL-12 7-1/2 1 51 DPL-13 7-1/2 1 57 DPL-15 7-1/2 1 68 DPL-16 10 1-3/16 80 DPL/DPL-AF-18 7-1/2 / 10 1-3/16 91 / 81 DPL/DPL-AF-20 10 / 15 1-3/16 104 / 96 DPL/DPL-AF-22 10 / 15 1-7/16 148 / 139 DPL/DPL-AF-24 15 / 20 1-7/16 185 / 162 DPL/DPL-AF-27 15 / 25 1-7/16 205 / 185 DPL/DPL-AF-30 20 / 30 1-11/16 236 / 248 DPL/DPL-AF-33 25 / 40 1-15/16 288 / 306 DPL/DPL-AF-36 30 / 40 1-15/16 344 / 357 ALL SHAFTS ARE KEYWAYED Fig. 1 GENERAL Inspect unit for damage, report any shipping damage to carrier. Check all fasteners and re-tighten as required. Rotate the blower wheel by hand to ensure free rotation.. If rubbing occurs, loosen the set screw(s), re-position the wheel to the shaft centre, re-tighten set screw(s). UNIT DESCRIPTION Rigid welded angle iron frame construction. Full Class II capability. Min L10 bearing life of 35,000 hrs (average L50 bearing life of 175,000 hrs). Standard backwardly inclined flat blade steel wheel for DPL-12 through DPL-36 (aluminum wheel available as an option). Standard Aluminum airfoil wheel for DPL-AF-18 through DPL-AF-36.

INSTALLATION 1. Secure the unit through the mounting holes located on the angle iron frame. 2. Rotate the blower wheel by hand. It should not rub against the inlet venturi. If rubbing occurs, loosen the hub bolts and adjust the motor wheel position. 3. Install the motor mounting platform using the hardware supplied with the optional 10-30 HP motor platform. Mount the motor to the motor platform (motor platform shown in Figure 2) from Delhi Industries, or base mount the motor. (supplied by others) WHEEL MOTOR PLATFORM DIAMETERS MAX HP MAX FRAME SIZE 12 TO 20 22 TO 27 30 TO 36 10 15 30 215T 284T 286T FIGURE 3: 10-30 HP OPTIONAL MOTOR PLATFORM 4. Mount the blower sheave on the blower shaft and tighten its set-screw securely on the key of the shaft. (See Table 1 for drive data). 5. Mount the motor sheave on the motor shaft. Leave some clearance between the pulley and the motor end bell. Tighten the set-screws on the key of the motor shaft. 6. When using the 10-30 HP motor platform, with the slide base in its minimum position install the V belt within the sheave grooves. Adjust the sheave on the blower shaft to ensure proper pulley alignment (see Figure 3) and secure in place. A straight edge across the face of the driven pulley should be parallel to the belt once proper alignment has been achieved. WARNING: Excessive belt tension is the most frequent cause of bearing wear and resulting noise. Proper belt tension is critical for quiet efficient operation. FIGURE 3: PULLEY ALIGNMENT 7. Adjust the slide base motor platform to tighten the belt. Ideal belt tension is the lowest tension at which the belt will not slip during start up. As rule of thumb suggests that ¾ of deflection mid span under medium finger pressure (2-3 lbs.) for every foot of span is approximately proper belt tension. Tighten all hardware once belt has been adjusted properly.

Correction Factors: PERFORMANCE CONSIDERATIONS The actual performance of the plenum is based upon the overall design of the plenum system. Two correction factors must be applied to all plenum fans. 1. Outlet duct loss 2. Influence of adjacent plenum walls ESTIMATED LOSSES DUE TO PLENUM OUTLETS Outlet losses based on the outlet configuration and duct velocity must be included in the systems external static pressure requirements. Outlet losses are dependent on the direction of the outlet, shape of the outlet and size of the Plenum. On Plenum s with more than one discharge, select the configuration that has the greatest loss. CORRECTION FACTOR CALCULATIONS INCLUDED IN DELAIR SOFTWARE PACKAGE AVAILABLE FOR DOWNLOAD OR ON CD AT: WWW.DELHI-INDUSTRIES.COM

CORRECTION FACTORS DUE TO INFLUENCE OF ADJACENT PLENUM WALLS

ELECTRICAL WARNING: Ensure power supply is disconnected and locked out prior to making electrical connections. Before connecting the motor to the electrical supply, check the electrical characteristics and wiring instructions as indicated on the motor nameplate or as shown below. Complete electrical connections as indicated. WARNING: A ground wire must be connected from the motor housing to a suitable electrical ground. OPERATION 1. After electrical connections are completed, remove belts, energize the motor momentarily to ensure proper motor rotation. Re-install the belts. 2. With the air systems in full operation and all ducts and access panels attached, measure current input to the motor and ensure that it is less than the rated full load motor amperage. 3. Proper adjustment to the belt tension is critical for quiet efficient operation. MAINTENANCE Ensure power supply is disconnected and locked out prior to performing maintenance 1. Inspect and tighten the wheel hub bolts after the first 50 to 100 hours of operation and periodically thereafter. 2. Follow the motor manufacturer s instructions for motor lubrication. Remove any excess lubrication. 3. Drives: A Check belt tension and alignment, replace cracked or worn belts. If it is necessary to replace one belt on a multiple belt drive, replace all the belts with a matched set. B Under normal conditions, no re-lubrication is the rule. The bearing lubricant cavity is 1/3-1/2 filled as shipped from the factory. Never lubricate new bearings. C Tighten set-screws on sheaves, wheel and bearing locking collars. 4. Clean the blower wheel periodically. Material build up on the blades can cause wheel imbalance which, may result in wheel or motor bearing failure. 5. Generally, bearings should be lubricated at six to twelve month intervals. Recommended lubricants are: a) Imperial Oil ESSO Beacon 325, or b) Shell Oil Alvania Grease #3. A small amount of grease should be added slowly when the shaft is rotating. Note: Over greasing may cause damage to the bearing. Avoid rupturing the bearing seal. 6. To reinstall replacement ball bearings press the locking collar against the inner ring of the bearing and turn in the direction of the shaft rotation until engaged. Insert a drift pin into the pin hole and tap lightly to set. Tighten setscrew on locking collar firmly. 7. Should further service to the blower be necessary, refer to the exploded view illustration (see Figure 4).

PARTS LIST 1.PLENUM INLET WALL 2.DETACHABLE INLET VENTURI 3.C-SHAPED FRAME 4.T-BAR 5.PILLOW BLOCK BEARING 6.SHAFT 7. BACKWARDLY INCLINED FLAT BLADE STEEL WHEEL OR BACKWARDLY INCLINED AIRFOIL WHEEL 6 5 3 2 4 7 8 3 5 1 FIGURE 4:EXPLODED VIEW WARRANTY Delhi Industries Inc. Air Moving Products are guaranteed for a period of one year against manufacturing defects in material and workmanship when operating under normal conditions. Liability is limited to the replacement of defective parts. Labour and transportation costs are not included.