model 2000SN FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS Recessed Wall-Mount Bottle Filling Station

Similar documents
Model 2000SMS/2000SMSN Bottle Filler with Lifecycle Control

Modular Outdoor Fountain System

Installation Instructions

H1011.8HO Barrier-Free Wall Mounted Electric Drinking Fountain

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

FILTER KIT. HWF172 Watersentry VII Kit (Lead, Aesthetic Chlorine Taste & Odor & Particulate Class I Reduction) FOR COMMERCIAL USE ONLY

FILTER KIT EWF172 Watersentry VII KIT (Lead, Aesthetic Chlorine Taste & Odor & Particulate Class I Reduction) FOR COMMERCIAL USE ONLY

Model 1920FR Drinking Fountain

Halsey Taylor Owners Manual

Model 8309WC Barrier Free Shower & Eye/Face Wash

model H with1920

Model 8309WC Barrier Free Shower & Eye/Face Wash

model1001 with1920 ADA Compliant Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS

Halsey Taylor Owners Manual

Model 8346/8346CRP Shower & Eye/Face Wash

Installation/Care/Use Manual

F3000-B2B, F3000-B2M FILTRATION SYSTEM INSTRUCTION MANUAL

Model 8317 Combination Shower Eye/Face Wash

5874SS/5874PB/5874PBF/VRK5874/PBA6/ PBA6HPB/PBA7 Valve/Push Button

Model 8300 & 8300CRP Shower/Eyewash

Model 1001/1001HPS Drinking Fountain

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

5874PB/5874PBF/VRK5874/VRK5874HF/ PBA6/ PBA7 Valve/Push Button

Owner s Manual WARNING

Installation, Operation and Maintenance Manual

model1001 with1920 ADA Compliant Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS

Viking Installation Guide

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Surface Mounted Bottle Fillers

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS STUDIO S

INSTALLATION INSTRUCTIONS PATIENCE

Full Flow Drinking Water System Model: 3MFF100

Installation Instructions AQ-4000 Countertop Water Filter. White, Black, and Brushed Steel finishes

Installation Instructions

Scale Feeder Manifold Water Filtration System Instruction Manual

Installation Instructions Series Series

Viking Installation Guide

Installation Instructions

Undercounter Refrigeration Design Guide

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

Installation Instructions

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

Installation Instructions

Installation, Operation and Maintenance Manual

Set Up Instructions. Powered Water Filtration System. We re here to help! Quick Start

Installation Instructions

NSF MODELS: CTP200, CTP100. This System does not require the services of a plumber. Read and Save these Instructions. Important

Installation and Operating Instructions

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Installation Instructions

PRE-PLUMBED SEWAGE SYSTEM

Installation Instructions

Hydrosafe - Model HSFS

Installation/Care/Use Manual

SERIN MONOBLOCK LAVATORY FAUCET with

Undercounter Refrigeration Design Guide

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Dual Flow Manifold Systems Instruction Manual

ONLINE WARRANTY INFORMATION CrystalQuest.com/warranty.html

Installation Instructions 7024

Pressure Product Catalog

Installation Instructions

Installation Instructions

Installation Instructions

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

VWR Zero Air Generator

Installation Instructions Series

Installation and Operation Manual

The BEST Plumbing Specialties. One Source. B 1 Quality, Durability, reliability

ETF-600 Sensor Operated Lavatory Faucet

LZS8WS EZH2O BOTTLE FILLING STATION & COOLER

Installation Instructions

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation Instructions

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

PURE WATER. Installation, Operation and Maintenance Manual. 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG. Important.

Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation Instructions

Installation Instructions

CARBONATORS & WATER BOOSTERS

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

MONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR

Installation Instructions

Installation Instructions

Everpure Claris filter cartridge family

Installation Instructions

Installation Instructions

MONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR

Owner s Manual Pelican Whole House Iron and Manganese Filtration System

Installation/Care/Use Manual

INSTALLATION INSTRUCTIONS

MONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR

GE Infrastructure Water and Process Technologies. Merlin Point of Use Drinking Water System. Installation and Maintenance Manual

Installation and Operation Manual

A152/FG-BF4 Series Rounded Box Barrier-Free Wall Mount Bi-Level Drinking Fountain with Sensor Activated Bottle Filler

Milano AUTOMATIC FAUCET

Dual Port Manifold Water Filtration Systems Instruction Manual

Transcription:

model 2000SN Recessed Wall-Mount Bottle Filling Station FEATURES & BENEFITS QUALITY CONTROL The Haws bottle filling station is pre-built and fully water and pressure tested to ensure no leaks and proper function for reduced installation time and added peace of mind. SERVICING & SECURITY Durable ABS plastic front panel allows simple access to internal components. 30 second time-out prevents unwanted use. Hidden lock and hinges discourages vandals. ADVANCED FILTRATION 2,500-gallon (9463 L) capacity, electronic lifecycle control filter cartridge will shut off water flow when capacity is reached to ensure fresh, filtered water with every activation. Filter replacement indicator light will flash yellow when filter life is at 10% and will flash red when replacement is necessary. Preparing to replace filter is important when the filter light flashes yellow. DURABLE FINISH #4 satin stainless steel back panel can be easily cleaned and maintained while also resisting corrosion. SENSOR OPERATED Electric sensor allows for tough-free hygienic operation, eliminating the need for manual activation. OPTIONS 2000 Series Mounting Frame: Model MTGFR.HSC, galvanized steel mounting frame with grille for the 2000 series bottle filling stations. Remote Drinking Fountain Water chiller: Model HCR8, 8 gph (30.3 L) remote water chiller provides instantaneous cooling to meet a continuous demand for chilled water. For more information, visit www.hawsco.com or call (888) 640-4297. SPECIFICATIONS Model 2000SN Hydration By Haws water dispenser is a semi-recessed, wall-mounted wheel chair accessible bottle or cup filling station constructed of durable ABS plastic and 16 gauge, Type 304 Stainless Steel with a satin finish. It features an electric sensor for touch-free hygienic operation and a 30-second timeout preventing unwanted use, laminar flow to prevent splashing, and.5 gpm (1.9 L) flow rate for quick fill-up. 2,500-gallon (9464 L) carbon block filter reduces chlorine (taste and odor) and lead, and removes 99.99% of cysts. The mounting frame is of heavy gauge, galvanized steel. 110 volt, 60Hz, and.1 amp draw when in use. Tailpiece is 1-1/4" (32 mm) O.D. Provision for trap (not included) must be made in or behind wall. Model 2000SN has no logo for a clean, aesthetically pleasing look. APPLICATIONS Perfect for either public or private indoor settings, the Hydration By Haws bottle filling station is a great fit in areas where aesthetics are important to the overall appeal of the architecture. Specifically, this type of semi-recessed wall mounted bottle filling station is ideal for office buildings, airports, schools, manufacturing facilities and municipalities.model 2000SN meets the Americans with Disabilities Act when mounted at the correct height. Haws manufactures drinking fountains and electric water coolers to be lead-free by all known definitions including NSF/ANSI Standard 61, Section 9, NSF/ANSI Standards 42 & 53, NSF/ANSI 372 and CSA Standard B483.1. Product is compliant to California Health and Safety Code 116875 (AB 1953), California Proposition 65 and the Federal Safe Drinking Water Act. Model 2000S is certified to the Standard for Water Treatment Appliances (UL979). 1455 Kleppe Lane :: Sparks, NV 89431 :: p. 775.359.4712 :: f. 775.359.7424 :: e. info@hawsco.com :: www.hawsco.com :: 20 June, 2018 DISCLAIMER: Continued product improvements make specifications subject to change without notice. Check www.hawsco.com for the latest product information and updates.

INSTALLATION GUIDE 1455 Kleppe Lane Sparks, NV 89431-6467 (888) 909-4297 website: www.hawsco.com Model 2000S/2000SN Bottle Filler with Lifecycle Control No. 0510000663 (2) NOTE: A Class A ground-fault circuit interrupter (GFCI) shall be installed in the branch-circuit supplying power to this unit. CAUTION! Prior to making any electrical connections, verify with a voltmeter that power from the service panel is off. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL, OR REQUIRE REPLACEMENT PARTS, PLEASE CALL: TECHNICAL SUPPORT: 1-800-766-5612 HOURS OF OPERATION: MON-THURS 7:00a.m. - 4:30p.m PT, FRI 7:00a.m.- 11:00a.m. PT QUICK START REFERENCE PARTS LIST: 1 bottle filler, 1 filter cartridge, 1 plastic drain basin, 1 brass waste bend, 1 waste nut, 1 rubber waste washer, 1 hex key, 2 drain basin screws, 2 drain basin screw washers. RECOMMENDED TOOLS: Phillips screwdrivers, level, slip joint pliers. REQUIRED PARTS (NOT SUPPLIED): Qty. 6 10 #6 sheet metal or wood screws (depending on construction of wall studs), 1/2 screwdriver stop, 3/8 tubing (to be used for water supply inlet), 1-1/4 trap, qty. 3 wire connectors. PRODUCT INSTALLATION: When installing this product, local, state or federal codes should be adhered to. This unit is certified for indoor use only. SUPPLY LINE: Minimum recommended line size is 1/2" IPS with 30-90 PSI (2-6 ATM) flowing pressure; supply water is to be cold water supply. Intended for municipal water only. PLUMBING CONNECTIONS: Inlet is 3/8 O.D. push-in type fitting. Waste bend is 1-1/4 O.D. pipe; an acceptable trap must be used after waste bend. ELECTRICAL CONNECTIONS: 115VAC, 60HZ, approx. 0.14A. Unit wired directly to incoming line (stripped leads provided). RATED SERVICE FLOW: 0.5 GPM (2725L/day) OPERATING TEMPERATURE: 35 100 F (1.7 37.8 C) OPERATING PRESSURE: 30-90 PSI FILTER CAPACITY: 2500 gallons (9460L) or 1 year REPLACEMENT FILTER CARTRIDGE: Electronic Lifecycle Control Filter Model 6423 2017 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 08/17 Model 2000S/2000SN Page 1 of 6

INSTALLATION PROCEDURE WARNING: Make certain power is disconnected before installation to reduce risk of electrical shock. WARNING: Filter is not intended to withstand operating pressures greater than 100 PSI (6.8 ATM). If inlet pressure is greater than this, filter must be protected with a pressure regulator. NOTES: 1. This unit is certified for indoor use only. Step 1: 2. For all plastic push-in type fitting connections, only connect NSF-61 copper or plastic tubing. Stainless steel or glass tubing is not recommended. The following assembly instructions must be followed to ensure a watertight connection: a. Cut tubing square and clean. b. Mark from end of tube the length of insertion (See table below). c. Push tube into the fitting until it bottoms out. d. To remove, depress collet and pull tubing out. Tube Sizes O.D. Tolerance Insertion Depth 1/4 ±.005 11/16 3/8 ±.005 3/4 1/2 ±.005 7/8 3. Use NSF-61 approved pipe joint sealant on all threaded water connections. 4. Do not use with water that is microbiologically unsafe or unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. 5. Use the cardboard inserts from the box to support the unit while preparing for installation by placing unit face down on inserts. To open the unit, slide the supplied hex key into the notch in the left-hand side of the hinged upper plastic panel and press the key firmly in that same direction. This will disengage the internal spring latch. Simultaneously pull open the hinged panel (see Step 1 Diagram). Take care not to damage the stainless steel panel or the spring latch in this process. Step 1 Diagram Step 2: Unscrew the 4 side-mounted panel screws on the outside of the bottle filler using the 08/17 Model 2000S/2000SN Page 2 of 6

supplied hex key, and remove the mounting frame from the bottle filler (see Step 2 Diagram). Step 3: Use the 2 washers and the 2 screws supplied to attach drain basin to unit as shown in Step 3 diagram (other components removed for clarity). Install waste bend with nut and rubber washer as shown (see Step 3 Diagram). Step 2 Diagram Step 3 Diagram (Back View) Step 4: Firmly screw filter cartridge into filter head (see Step 4 Diagram). NOTE: Bottle filler will work only if a filter cartridge is installed and its wiring is plugged in (see Step 9). 08/17 Model 2000S/2000SN Page 3 of 6

Step 5: Create a wall opening for the unit as shown in Step 5 Diagram hold rough-in dimensions to within 1/8. The bottle filler is designed to fit between two normally spaced 2 X 4 studs (16 center-to-center). Install waste line, supply line, and electrical lines in locations shown. The supply line should be brought up through the rectangular waste cutout in the bottom of the unit. Double-check waste, supply, and electrical line locations. Install a 1/2 IPS supply screwdriver stop (not supplied) into the water supply line where it will be readily accessible. NOTE: A suitable trap must be used in conjunction with the waste. This trap should be positioned in a location where it can be accessed and removed (it may be helpful to use a wall-mounted access panel). NOTE: When installing this unit, all pertinent local, state, or federal codes should be adhered to. Bottle filler (rear cover removed) viewed from behind wall Step 5 Diagram 08/17 Model 2000S/2000SN Page 4 of 6

Step 6: Place the mounting frame into its opening such that it sits flush against the wall. Use some appropriate #6 screws (between 4 & 8 as required; not supplied) to secure the frame into the wall; notice that mounting holes are provided in the top, bottom, and sides of the mounting frame (see Step 6 Diagram). Use a level to verify that the mounting frame is level horizontally and vertically; this will help to assure proper drainage and water flow that is properly aligned. Step 6 Diagram Step 7 Diagram Step 7 Diagram Step 7: Place the bottle filler onto its mounting frame and make the connection between the bottle filler waste and the plumbed-in waste line. Secure the bottle filler to the mounting frame using the 4 screws removed in Step 2 (see Step 7 Diagram). Step 8: Open the power junction box; run supply power wiring through the bottom cable grip. Connect supply power to lead (black), neutral (white), and ground (green) wires inside the box (stripped leads provided) (see Step 8 Diagram). Replace cover. Step 8 Diagram 08/17 Model 2000S/2000SN Page 5 of 6

Step 9: Run 3/8 tubing (not supplied) between the screwdriver stop (installed in Step 5) and the bottle filler s supply inlet elbow in the filter head (it may help to temporarily remove the filter cartridge see Step 9 Diagram). Connect the wiring coming off of the filter cartridge to the wiring coming out of the circuit board enclosure (see Step 9 Diagram). Step 10: Step 11: Open the screwdriver stop wide open and check for leaks. Close the hinged upper panel and provide power to the bottle filler. Activate the bottle filler by placing a bottle or cup in front of the sensor (see Step 11 Diagram A). If water does not dispense, see the Troubleshooting Guide in the Owner s Manual. The pressure regulator may need to be adjusted to better complement the input pressure at the installation site (see Step 11 Diagram B below). To do so, pull out the adjustment knob and rotate as needed (clockwise from the front of the unit decreases flow); push knob in when desired flow is achieved. * Flow rate is factory set to the maximum flow rate for reduced water consumption. Step 9 Diagram (Back View) Step 11 Diagram A Step 11 Diagram B Step 12: Approximately five gallons of water must be run through the system after the unit is installed in order to remove the loose carbon particles from the filter cartridge and any air bubbles from the system (both of these are normal occurrences after a filter change). Check the system for leaks. Place hex key in a secure location. 08/17 Model 2000S/2000SN Page 6 of 6