IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Similar documents
READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTIONS

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

Captivate Illuminated Mirror Light

Specification Grade Contemporary Wall Mount/Technical Installation Data

INSTALLATION GUIDE Works in double and single ended wiring.

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

LED Recessed Troffer Retrofit Kit

MAXLITE RKT LED Retrofit Kit

MOONRING 1.5 MOONRING 3

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

Universal Retrofit System Installation Instructions Revised:

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Wet Rated Batten LED Luminaire

Horticulture Batten LED Luminaire

Lumination TM LED Luminaire LUR Series

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

SURE-LITES FBP140XLP Instruction Manual

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

IMMERSION. imagination at work. Retrofit Installation Guide. GE Lighting. LED Refrigerated Display Lighting

GETTING STARTED WITH IN-WALL DIMMER SWITCH

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

IMMERSION. GE Lighting. OEM Installation Guide. imagination at work. LED Display Lighting

AEROBAY INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation Instructions BLTR and 2BLTR Relight Assembly

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps


LED IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

I. Pendant Mount Installation

LED Utility Wrap Fixture

LED 2/3/4ft T8 Tube 120V

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

WARNING / AVERTISSEMENT

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

INSTALLATION INSTRUCTIONS

TECTONIC LED CORP. ISO

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION Bollard Light 12V

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

INSTALLATION INSTRUCTION

UL AND CODE COMPLIANCE

Installation Instructions Central Battery Units

Installation Instruction

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

Product Installation Instruction LED Tube Lamp Retrofit Kits

Cable Cubby 1202 and 1402 Installation Guide

poollux Power plx-pw60 & plx-pw100

IMMERSION. imagination at work. LED Refrigerated Display Lighting. Vertical Cases RV40 Series LED Drivers GEPS4000NCMUL-SY

IMPORTANT SAFEGUARDS

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

LAL SERIES LED LUMINAIRE

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Installation and Operation Instructions 10/04/13

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Instruction/Installation Manual

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Cable Cubby 650 UT Installation Guide

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

P

Transcription:

ZR-RK Series LED Retrofit Troffer Kit Includes: ZR22RK and ZR24RK Standard and Emergency Luminaires IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION DANGER RISQUE DE CHOC COUPER L ALIMENTATION AVANT L INSTALLATION 2. WARNING Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of the LED upgrade kit. Check for enclosed wiring and components. ATTENTION - Risque d incendie ou de choc électrique. Câblage électriques peuvent être endommagés lors du perçage pour l installation du kit upgrade LED. Vérifier les fils et composants. 3. WARNING Risk of fire or electric shock. LED Upgrade Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Product must be installed in accordance with NEC or your local electrical code. If you are not familiar with these codes and requirements, contact a qualified electrician. ATTENTION- Risque d incendie ou de choc électrique. L installation du kit upgrade LED exige la connaissance des systèmes électriques pour luminaires. Si non qualifié, ne tentez pas d installation. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié. 4. WARNING Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings where the input rating of the retrofit kit does not exceed the input rating of the luminaire. ATTENTION - Risque d incendie ou de choc électrique. Installez ce kit seulement dans les luminaires qui ont les caractéristiques de construction et les dimensions dans les photographies ou les dessins de la page suivante. 5. Only the holes indicated in the photographs or drawings may be made or altered as a result of the kit installation. Do not leave any other holes open in a wiring enclosure or electrical component. Seulement les trous indiqués dans les photographies ou les dessins peuvent être faits ou altérés pour l installation du kit upgrade LED. Ne laissez aucun trou ouvert dans le compartiment électrique. 6. WARNING To prevent wiring damage or abrasion, do not expose wires to the edge of sheet metal or any other sharp objects. ATTENTION - Pour éviter les dégâts de câblage par l abrasion, ne pas mettre en contact les fils électriques avec des bords de tôle ou d autres objets pointus. 7. CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment. 8. For Emergency Luminaires, to reduce the risk of electric shock, disconnect both standard and emergency power supplies and converter connector of the emergency driver before servicing. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE LIST OF SUPPLIED COMPONENTS Kit contains the following parts: Assembly Sliding End Cap NOTES: 1. Upgrade Kit is for installation in 2x2 or 2x4 recessed troffer that are using NEMA 9/16 or 15/16 T-Bar ceiling grid. 2. We recommend a test installation before final installation due to variety of troffer styles and ceiling grid types. During test installation, determine if lamp holders and ballast need to be removed 3. Minimum internal pan size of existing pan is: 2x2 23.5 (W) x 23.5 (L) x 3 (H) 2x4 23.5 (W) x 47.5 (L) x 3 (H) Side Panel 4. Designed for use in 120-277V 50-60 Hz protected circuit (fuse box, circuit breaker). Supply wire sized as per NEC or governing code(s), 90C rated. 5. Products with the -EB suffix are provided with a factory-installed emergency lighting LED battery pack and are eligible to serve as part of a facility s emergency lighting system in accordance with ANSI/ NFPA 101 and Article 700 of ANSI/NFPA 70. 6. When mounted at or below 15ft, -EB products will provide the required 1 foot-candle of illuminance on the floor. 7. Make sure to cap off all unused leads. 8. Consult your local authority regarding disposal or recycling of removed ballast and lamp. 9. ** Not intended for use with 9/16 T-Bar grids unless used with a 9/16 accessory clip like Armstrong LFC- Fixture Clip which can be purchased through distribution. Consult factory for non-standard grid applications. Refer to Figure 2. 1 of 5 LPN00429X0001A2_A

TO INSTALL: 1 Lamp Holder Leads Lamp Holder REMOVAL OF EXISTING LIGHT ENGINE Disconnect power to the host lighting fixture to be replaced. Ballast Cover Ballast Remove the /Louver, Fluorescent Light Bulbs, Lamp Holders (if applicable), Lamp Holder Leads and Ballast Cover from existing lighting fixture. See Figure 1. Fluorescent Light Bulbs /Louver STEP 3: Cut the power wires going into the input side of the ballast. The ballast may remain in place, unless it is determined that it needs to be removed to provide extra clearance. NOTE: If parts have to be removed from the host lighting fixture in order to complete the installation of this upgrade kit, then make sure that open holes are closed-off utilizing the existing host lighting fixture hardware (i.e. screws, covers, etc.) 2 3 End Cap 4 This Corner goes in First for Assembly Installation Assembly Armstrong LFC- Fixture Clip to use for 9/16th applications. Sliding End Cap Existing Troffer Pan Assembly This Corner goes in First for Sliding End Cap Installation INSTALLATION OF ZR-RK RETROFIT NOTE: Bring the sliding end cap with you while installing the retrofit main assembly to have for Step 2. The sliding end cap has a belt hook feature that allows for easy carrying on your belt loop. The sliding end cap needs to be installed in Step 2 before stepping away or letting go of the main assembly to ensure the retrofit is secured into existing troffer pan. Bring the retrofit main assembly into the existing troffer pan at an angle as shown in Figure 3. Insert the corner of the main assembly that is circled in Figure 4 into the corner of the existing troffer pan between the existing troffer pan and the t-grid. Then slide the other end of the main assembly into the existing troffer pan. Gently push the full main assembly up into the existing troffer pan. Ensure that the end cap is flushed with the ceiling grid and that there are no gaps. NOTE: Do not let go off the assembly until Step 2 is finished. While holding onto the retrofit main assembly insert the corner of the sliding end cap that is circled in Figure 4 into the corner of the existing troffer pan between the existing troffer pan and the t-grid. Then attach the sliding end cap over the retrofit main assembly bracket. Once attached over the bracket slide the other end of the sliding end cap into place. Ensure that the sliding end cap and the main assembly are flushed together and that there are no gaps between the two. See Figure 5. STEP 3: Make wiring connections per the Electrical Connections section. STEP 4: Attach the safety cables to the existing troffer pan. Attach one end of each safety cable to the top of the existing troffer pan using supplied #8 self drilling screws. 2 of 5 LPN00429X0001A2_A

5 6 Safety Cable Retrofit Side Panel Sliding End Cap Assembly Bracket Edge of Side Panel insert into Existing Troffer Pan Ground Wire Ground Wire Attached to Main Retrofit Assembly 7 8 Retrofit Side Panel Latch Plastic Extruded Protector 9 Flat Edge Assembly Bracket STEP 5: Bring the retrofit side panel up to the existing troffer pan and connect the ground wire on the back of the side panel to the retrofit main assembly as shown in Figure 6. Tuck the ground lead up into the main assembly. STEP 6: Insert the edge of the side panel, that is opposite of latches, between the existing troffer pan and t-grid. Then insert the other side into the retrofit main assembly by engaging the 2 latches on the side panel into the 2 slots on the main assembly. See Figure 6 and 7. NOTE: Make sure not to pinch any wires, all wires should be tucked up inside the main assembly. STEP 7: Remove the LED plastic extruded lens protector and discard extruded lens protector. See Figure 8. STEP 8: Install the lens over the LEDs by putting the lens flat edge over one side of the bracket located on the main assembly. While pushing on the middle of the lens, to widen the lens, insert the other flat end of the lens over the other side of the bracket. See Figure 9 and 10. Figure 10 is on the next page. 3 of 5 LPN00429X0001A2_A

10 FCC NOTICE CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CAN ICES-005 (A)/NMB-005 (A) EMERGENCY DRIVER CHECK When AC power is applied, the charging indicator light is illuminated, indicating the battery is being charged. When power fails, the emergency driver automatically switches to emergency power, operating the LED array. When AC power is restored, the emergency driver returns to the charging mode. Although no routine maintenance is required to keep the emergency driver functional, it should be checked periodically to ensure that it is working. The following schedule is recommended: Visually inspect the charging indicator light monthly. It should be illuminated. Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds. When the test switch is depressed, the LED array should operate. Conduct a 90-minute discharge test once a year. The LED array should operate for at least 90 minutes. If the luminaire fails any of these checks, consult service personnel. REFER ANY SERVICING INDICATED BY THESE CHECKS TO QUALIFIED PERSONNEL EMERGENCY DRIVER AND AC DRIVER MUST BE FED FROM THE SAME BRANCH CIRCUIT NOTE: For short-term testing of the emergency function, the battery must be charged for at least one hour. The emergency driver must be charged for at least 24 hours before conducting a long-term test. ELECTRICAL CONNECTIONS LUMINAIRE FOR ZR22RK and ZR24RK : Make the following Electrical Connections: a. Connect the black fixture lead to the voltage supply Line position, Hot. b. Connect the white fixture lead to the neutral supply position. c. Connect the green ground lead to the incoming ground lead from the conduit or screw the green ground lead to the existing troffer pan if the safety ground is made through the pan on the existing troffer. d. If 0/1-10V Dimming is used, connect the violet lead to the supply positive dimming lead. If dimming is not being used ensure to cap off the violet lead. SUPPLY WIRING LINE 1 GREEN NEUTRAL VIOLET GREY LINE-BLACK GROUND-GREEN LINE-WHITE DIM (+) VIOLET DIM (-) GREY (DIMMING OPTIONAL) e. If 0/1-10V Dimming is used, connect the grey lead to the supply negative dimming lead. If dimming is not being used ensure to cap off the grey lead. 4 of 5 LPN00429X0001A2_A

ELECTRICAL CONNECTIONS FOR ZR22RK-EB and ZR24RK-EB : NOTE: The emergency driver must be fed from the same branch as the AC Driver. Using customer supplied 90 C minimum rated wire connectors, make the following electrical connections: a. Connect the black luminaire lead to the unswitched voltage supply lead. b. Connect the white/red luminaire lead to the switched supply switched. c. Connect white luminaire lead to the neutral supply lead. d. Connect ground bare or green/yellow lead to the incoming ground lead from the conduit or screw the green ground lead to the existing troffer pan if the safety ground is made through the pan on the existing troffer. e. If 0/1-10V Dimming is used, connect the violet lead to the supply positive dimming lead. If dimming is not being used ensure to cap off the violet lead. f. If 0/1-10V Dimming is used, connect the gray lead to the supply negative dimming lead. If dimming is not being used ensure to cap off the gray lead. Locate the two red leads in the junction box and connect them using customer supplied connector. SUPPLY WIRING GROUND NEUTRAL SWITCHED HOT UNSWITCHED HOT DIM (+) VIOLET DIM (-) GREY ** NOTE: DO NOT mate leads until installation is complete and AC power is supplied LUMINAIRE BARE OR GREEN/YELLOW WHITE WHITE WHITE/RED BLACK VIOLET GREY **RED **RED (DIMMING OPTIONAL) 2017 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change. See www.cree.com/lighting/products/warranty for warranty and specifications. Cree is a registered trademark, and the Cree logo is a trademark of Cree, Inc. www.cree.com/lighting 5 of 5 LPN00429X0001A2_A