SUBMITTAL DATA: MXZ-2C20NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz

Similar documents
SUBMITTAL DATA: MXZ-3C30NAHZ2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Yes Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz

SUBMITTAL DATA: MXZ-3C30NA2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM

SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz

SUBMITTAL DATA: MXZ-4C36NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM

SUBMITTAL DATA: MXZ-4C36NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Hermetic Fan Motor (ECM) F.L.A Sound Pressure Level

Job Name: Tag# 3 Port, 2-Ton Outdoor Heat Pump

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1AO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

Multi-Room Ductless heat-pump systems Submittal Data: MULTI56HP230V1AO 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 48,000 BTU/H RLA 23.0 A

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 53,000 BTU/H RLA 23.0 A

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

Bosch Climate 5000 Ductless Minisplit System

YCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

Version Modification Date Remark

HCH6. Product Specifications

Bosch BOVA Split System Heat Pump

SINGLE. Technical Data Book. HSP Duct for America (R410A, 60Hz, H/P)

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

PHR5. Product Specifications

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

PRAC14 PRODUCT SPECIFICATIONS

Bosch BOVA Split System Heat Pump

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

RAC. Technical Data Book. RAC for North America (Inv, R410A, 60Hz, HP)

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

PRPAC14 PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER INSTALLATION WARRANTY

Ductless Split Systems

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P)

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

VRF Technical Data Book

Ductless Systems. Right product for the right application. Fall 2015 Edition

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

2010 Duct-Free Splits Line Card

Multi-Splits. Split-System Air Conditioning. Multi-Splits

TECHNICAL SPECIFICATIONS WSH2BF

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

Ductless Split Systems

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

Job Name: Tag# 2.5-Ton Wall Mounted Heat Pump System. Indoor Specifications. Electrical. Outdoor Specifications. Piping Liquid (in) Efficiency

Ductless Split Systems

Ductless Split Systems

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

DLC4AV09J1A DLC4AV18K1B DLC4HV09J1A DLC4HV12J1A 1 DLC4HV12K1A 1 DLC4HV18K1A DLC4HV30K1A

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

Engineering Data Book

FSH1BE Series. High Efficiency Heat Pump TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 14 SEER Residential System 1 1/2 5 Ton Capacity

R4H4. Product Specifications

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

Technical Specifications

AIR CONDITIONING SYSTEMS. Debuting the New Multi System MXZ-5A100VA. Maximum comfort for 5 rooms, using 1 outdoor unit

HIGH-EFFICIENCY MINI-SPLIT AIR CONDITIONERS AND HEAT PUMPS

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

13 SEER Light Commercial 3 Phase

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data. S Two-stage scroll compressor S Variable speed blower motor Control

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

TECHNICAL SPECIFICATIONS

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

14 SEER R -410A PACKAGE DUAL FUEL HEAT PUMP 2 to 5 TONS Two -Stage, Gas Heating / Electric Heating and Cooling Unit

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

Q7RE Series Single Packaged Heat Pump, Single Phase

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

Enhanced Air Conditioning

High Cap. (Btuh) HSPF COP

MULTI F MAX HEAT PUMP SYSTEM ENGINEERING MANUAL. Multi-Zone Heat Pump Systems 1.5 to 4.5 Tons. Dual and Tri-Zone Multi F.

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control

COST vs. COMFORT. Experience the technology that ends the fight MITSUBISHICOMFORT.COM

WCA4**4. Product Specifications

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

FT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity

Transcription:

M-SERIES SUBMITTAL DATA: MXZ-2C20NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-2C20NAHZ ACCESSORIES 3/8" x 1/2" Port Adapter (MAC-A454JP; for use with 15,000 Btu/h Indoor units) M-NET Adapter (PAC-IF01MNT-E) Airflow Guide (PAC-SH96SG-E) Cooling* (Non-ducted / Ducted) Heating at 47 F* (Non-ducted / Ducted) Heating at 17 F* (Non-ducted/Ducted) Specifications Unit Type Model Name MXZ-2C20NAHZ Rated Capacity Btu/h / Capacity Range Btu/h 6,000 - Rated Total Input W 1,334 / 1,819 Rated Capacity Btu/h 22,000 / 22,000 Capacity Range Btu/h 7,400-25,500 Rated Total Input W 1,612 / 1,748 Rated Capacity Btu/h 13,700 / 13.700 Maximum Capacity Btu/h 22,000 / 22,000 Rated Total Input W 1,450 / 1,588 Heating at 5 F* Maximum Capacity Btu/h 22,000 Energy Star (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) (For data on specific indoor units, see the MXZ-C Technical and Service Manual.) Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 40 MCA A 28.9 Voltage Indoor - Outdoor S1-S2 V AC 208 / 230 Indoor - Outdoor S2-S3 V DC ±24 Compressor DC INVERTER-driven Twin Rotary Fan Motor (ECM) F.L.A. 1.9 Sound Pressure Level Cooling 54 db(a) Heating 58 External Dimensions (H x W x D) In / mm 41-9/32 x 37-13/32 x 13 1048 x 950 x 330 Net Weight Lbs / kg 187 / 85 External Finish Munsell No. 3Y 7.8/11 Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 / 6.35 In / mm Gas (Low Pressure) A,B: 3/8 / 9.52 Max. Refrigerant Line Length Ft / m 164 / 50 Max. Piping Length for Each Indoor Unit Ft / m 82 / 25 Max. Refrigerant Pipe Height If IDU is Above ODU 49 / 15 Ft / m Difference If IDU is Below ODU 49 / 15 Connection Method Flared/Flared Refrigerant R410A Yes * Rating Conditions per AHRI Standard: Cooling Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling Outdoor: 95º F (35º C) DB / W.B. 23.9 C (75 F) Heating at 47ºF Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47ºF Outdoor: 47º F (8º C) DB / 43º F (6º C) WB Heating at 17º F Indoor: 70º F (21º C) DB Heating at 17º F Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB

SPECIFICATIONS: MXZ-2C20NAHZ, contd. OPERATING RANGE: Cooling Outdoor D.B. 14 to 115 F [ D.B. 10 to 46 C]*1 Heating W.B. -13 to 65 F [ W.B. 25 to 18 C ] *1. D.B. 5 to 115 F [ D.B. 15 to 46 C ], when an optional Air Outlet Guide is installed. ENERGY EFFICIENCIES: Indoor Unit Type SEER EER HSPF Non-ducted (09 + 09) Ducted and Non-ducted COP @ 47 F COP @ 17 F 17.0 13.5 9.8 4.00 2.77 16.00 12.25 9.65 3.85 2.65 Ducted (09 + 12) 15.0 11.0 9.5 3.69 2.53 NOTES: Minimum of two Indoor Units must be connected to the MXZ-2C20NAHZ. Minimum installed capacity cannot be less than Btu/h. Total connected capacity must not exceed 130% of outdoor unit capacity. System can operate with only one Indoor Unit turned on. Information provided at 208/230V. For Reference: - MXZ-C Technical & Service Manual for detailed specifications and additional information per Indoor Unit Combination. - MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: Only 1 MVZ may be used on any system. When an MVZ is connected, total connected capacity must be 100% or less. When an MVZ is connected, no P-Series indoor units can be used (PCA, PLA, or PEAD). Notes:

MXZ-2C20NAHZ OPERATIONAL PERFORMANCE NON-DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) 1 6 1 9 1 12 1 15 2 12 2 15 Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C 6,000 - - 6,000 6 7,400 7,400 - - 9,000 9,000 - - 9 11,000 11,000 - - - - 12 14,400 14,400 - - 14,000 14,000 - - 15 - - 6,000 6,000-6 + 6 14,800 7,400 7,400-15,000 6,000 9,000-6 + 9 18,400 7,400 11,000-6,000-6 + 12 22,000 7,500 14,500-6,000 14,000-6 + 15 22,000 6,400 15,600-9,000 9,000-9 + 9 22,000 11,000 11,000-8,600 11,400-9 + 12 22,000 9,500 12,500-7,800 12,200-9 + 15 22,000 8,300 13,700-10,000 10,000-12 + 12 22,000 11,000 11,000 - DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) 1 9 1 12 1 15 Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C 9,000 - - 9,000 9 10,900 10,900 - - - - 12 13,600 13,600 - - 15,000 15,000 - - 15 - - 9,000 9,000-9 + 9 10,900 10,900-8,600 11,400-9 + 12 22,000 9,800 12,200-7,500 12,500-9 + 15 22,000 8,300 13,700-10,000 10,000-12 + 12 22,000 11,000 11,000 -

MXZ-2C20NAHZ DIMENSIONS: MXZ-2C20NAHZ Unit: inch (mm) Unit: inch (mm) Lock nut Conduit plate Conduit connector OBH702 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# MXZ-2C20NAHZ for Multiple Indoor Unit Styles - 201611

M-SERIES SUBMITTAL DATA: MXZ-3C24NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-3C24NAHZ ACCESSORIES 3/8" x 1/2" Port Adapter (MAC-A454JP-E) 1/2" x 3/8" Port Adapter (MAC-A455JP-E) 1/2" x 5/8" Port Adapter (MAC-A456JP-E) M-NET Adapter (PAC-IF01MNT-E) Airflow Guide (PAC-SH96SG-E) Cooling* (Non-ducted / Ducted) Heating at 47 F* (Non-ducted / Ducted) Heating at 17 F* (Non-ducted/Ducted) Specifications Unit Type Model Name MXZ-3C24NAHZ Rated Capacity Btu/h 22,000 / 23,600 Capacity Range Btu/h 6,000-23,600 Rated Total Input W 1,630 / 2,360 Rated Capacity Btu/h 25,000 / 24,600 Capacity Range Btu/h 7,200-30,600 Rated Total Input W 1,725 / 1,871 Rated Capacity Btu/h 14,000 / 14,000 Maximum Capacity Btu/h 25,000 / 24, 600 Rated Total Input W 1,622 / 1,635 Heating at 5 F* Maximum Capacity Btu/h 25,000 Energy Star (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 40 MCA A 29.9 Voltage Indoor - Outdoor S1-S2 V AC 208 / 230 Indoor - Outdoor S2-S3 V DC ±24 Compressor DC INVERTER-driven Twin Rotary Fan Motor (ECM) F.L.A. 1.9 Sound Pressure Level Cooling 54 db(a) (Non-ducted/Ducted) Heating 58 External Dimensions (H x W x D) In / mm 41-9/32 x 37-13/32 x 13 1048 x 950 x 330 Net Weight Lbs / kg 189 / 86 External Finish Munsell No. 3Y 7.8/11 Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 / 6.35 In / mm Gas (Low Pressure) A:1/2 / 12.7 ; B,C: 3/8 / 9.52 Max. Refrigerant Line Length Ft / m 230 / 70 Max. Piping Length for Each Indoor Unit Ft / m 82 / 25 Max. Refrigerant Pipe Height If IDU is Above ODU 49 / 15 Ft / m Difference If IDU is Below ODU 49 / 15 Connection Method Flared/Flared Refrigerant R410A * Rating Conditions per AHRI Standard: Cooling Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling Outdoor: 95º F (35º C) DB / W.B. 23.9 C (75 F) (For data on specific indoor units, see the MXZ-C Technical and Service Manual.) Heating at 47ºF Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47ºF Outdoor: 47º F (8º C) DB / 43º F (6º C) WB Yes Heating at 17º F Indoor: 70º F (21º C) DB Heating at 17º F Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB

SPECIFICATIONS: MXZ-3C24NAHZ OPERATING RANGE: Cooling Outdoor D.B. 14 to 115 F [ D.B. 10 to 46 C]*1 Heating W.B. -13 to 65 F [ W.B. 25 to 18 C ] *1. D.B. 5 to 115 F [ D.B. 15 to 46 C ], when an optional Air Outlet Guide is installed. ENERGY EFFICIENCIES: Indoor Unit Type SEER EER HSPF Non-ducted (06 + 06 + 09) Ducted and Non-ducted COP @ 47 F COP @ 17 F 19.0 13.5 10.0 4.25 2.53 17.3 11.75 9.5 4.03 2.52 Ducted (09 + 09 + 09) 15.5 10.0 9.0 3.80 2.51 NOTES: Minimum of two Indoor Units must be connected to the MXZ-3C24NAHZ. Minimum installed capacity cannot be less than Btu/h. Total connected capacity must not exceed 130% of outdoor unit capacity. System can operate with only one Indoor Unit turned on. Information provided at 208/230V. For Reference: - MXZ-C Technical & Service Manual for detailed specifications and additional information per Indoor Unit Combination. - MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: Only 1 MVZ may be used on any system. When an MVZ is connected, total connected capacity must be 100% or less. When an MVZ is connected, no P-Series indoor units can be used (PCA, PLA, or PEAD). Notes:

MXZ-3C24NAHZ OPERATIONAL PERFORMANCE NON-DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) 1 6 1 9 1 12 1 15 1 18 2 12 2 15 3 18 3 21 3 24 3 24 Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C 6,000 6,000 - - 6 7,400 7,400 - - 9,000 9,000 - - 9 11,000 11,000 - - - - 12 14,400 14,400 - - 14,000 14,000 - - 15 - - 17,200 17,200 - - 18 21,600 21,600 - - 6,000 6,000-6 + 6 14,800 7,400 7,400-15,000 6,000 9,000-6 + 9 18,400 7,400 11,000-6,000-6 + 12 22,000 7,500 14,500-9,000 9,000-9 + 9 22,000 11,000 11,000-6,000 14,000-6 + 15 22,000 6,400 15,600-8,600 11,400-9 + 12 22,000 9,500 12,500-5,600 16,200-6 + 18 22,000 5,600 16,400-8,500 13,300-9 + 15 22,000 8,300 13,700-10,900 10,900-12 + 12 22,000 11,000 11,000-7,500 14,300-9 + 18 22,000 7,400 14,600-10,100 11,700-12 + 15 22,000 9,800 12,200-6,000 6,000 6,000 6 + 6 + 6 22,200 7,400 7,400 7,400 5,100 5,100 7,700 6 + 6 + 9 24,800 7,100 7,100 10,600 22,000 5,500 5,500 11,000 6 + 6 + 12 25,000 6,300 6,300 12,300 22,000 5,500 8,300 8,300 6 + 9 + 9 25,000 6,300 9,400 9,400 5,500 5,500 12,900 6 + 6 + 15 25,000 5,600 5,600 13,700 5,300 8,000 10,700 6 + 9 + 12 25,000 5,600 8,400 11,000 8,000 8,000 8,000 9 + 9 + 9 25,000 8,300 8,300 8,300

MXZ-3C24NAHZ OPERATIONAL PERFORMANCE, contd. DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) 1 9 1 12 1 15 1 18 Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C 9,000 9,000 - - 9 10,900 10,900 - - - - 12 13,600 13,600 - - 15,000 15,000 - - 15 - - 17,200 17,200 - - 18 21,600 21,600 - - 9,000 9,000-9 + 9 10,900 10,900-21,000 9,000-9 + 12 9,700 12,100-8,200 13,600-12 + 12 8,200 13,600-10,900 10,900-9 + 15 10,900 10,900-7,500 14,300-9 + 18 7,300 14,500-9,700 12,100-12 + 15 9,400 12,400-23,600 7,900 7,900 7,900 9 + 9 + 9 24,600 8,200 8,200 8,200

MXZ-3C24NAHZ MXZ-3C30NAHZ DIMENSIONS: MXZ-3C24NAHZ Unit: inch (mm) Unit: inch (mm) Lock nut Conduit plate Top Conduit connector Conduit plate Under OBH702 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# MXZ-3C24NAHZ for Multiple Indoor Unit Styles - 201611

M-SERIES SUBMITTAL DATA: MXZ-3C30NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: ACCESSORIES 3/8" x 1/2" Port Adapter (MAC-A454JP-E) 1/2" x 3/8" Port Adapter (MAC-A455JP-E) 1/2" x 5/8" Port Adapter (MAC-A456JP-E) 1/4" x 3/8" Port Adapter (PAC-493PI) 3/8" x 5/8" Port Adapter (PAC-SG76RJ-E) M-NET Adapter (PAC-IF01MNT-E) Airflow Guide (PAC-SH96SG-E) Outdoor Unit: MXZ-3C30NAHZ Cooling* (Non-ducted / Ducted) Heating at 47 F* (Non-ducted / Ducted) Heating at 17 F* (Non-ducted/Ducted) Specifications Unit Type Model Name MXZ-3C30NAHZ Rated Capacity Btu/h / Capacity Range Btu/h 6,000 - Rated Total Input W 2,272 / 2,661 Rated Capacity Btu/h 28,600 / 27,600 Capacity Range Btu/h 7,200-36,000 Rated Total Input W 2,096 / 2,187 Rated Capacity Btu/h / 16,500 Maximum Capacity Btu/h 28,600 / 27, 600 Rated Total Input W 1,991 / 1,993 Heating at 5 F* Maximum Capacity Btu/h 28,600 Energy Star (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) (For data on specific indoor units, see the MXZ-C Technical and Service Manual.) Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 40 MCA A 29.9 Voltage Indoor - Outdoor S1-S2 V AC 208 / 230 Indoor - Outdoor S2-S3 V DC ±24 Compressor DC INVERTER-driven Twin Rotary Fan Motor (ECM) F.L.A. 1.9 Sound Pressure Level Cooling 54 db(a) Heating 58 External Dimensions (H x W x D) In / mm 41-9/32 x 37-13/32 x 13 1048 x 950 x 330 Net Weight Lbs / kg 189 / 86 External Finish Munsell No. 3Y 7.8/11 Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 / 6.35 In / mm Gas (Low Pressure) A:1/2 / 12.7 ; B,C: 3/8 / 9.52 Max. Refrigerant Line Length Ft / m 230 / 70 Max. Piping Length for Each Indoor Unit Ft / m 82 / 25 Max. Refrigerant Pipe Height If IDU is Above ODU 49 / 15 Ft / m Difference If IDU is Below ODU 49 / 15 Connection Method Flared/Flared Refrigerant R410A Yes * Rating Conditions per AHRI Standard: Cooling Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling Outdoor: 95º F (35º C) DB / W.B. 23.9 C (75 F) Heating at 47ºF Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47ºF Outdoor: 47º F (8º C) DB / 43º F (6º C) WB Heating at 17º F Indoor: 70º F (21º C) DB Heating at 17º F Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB

SPECIFICATIONS: MXZ-3C30NAHZ, contd. OPERATING RANGE: Cooling Outdoor D.B. 14 to 115 F [ D.B. 10 to 46 C]*1 Heating W.B. -13 to 65 F [ W.B. 25 to 18 C ] *1. D.B. 5 to 115 F [ D.B. 15 to 46 C ], when an optional Air Outlet Guide is installed. ENERGY EFFICIENCIES: Indoor Unit Type SEER EER HSPF Non-ducted (06 + 06 + 09) Ducted and Non-ducted COP @ 47 F COP @ 17 F 18.0 12.5 11.0 4.00 2.65 17.00 11.40 10.40 3.85 2.58 Ducted (09 + 09 + 09) 16.0 10.3 9.8 3.70 2.50 NOTES: Minimum of two Indoor Units must be connected to the MXZ-3C30NAHZ. Minimum installed capacity cannot be less than Btu/h. Total connected capacity must not exceed 130% of outdoor unit capacity. System can operate with only one Indoor Unit turned on. Information provided at 208/230V. For Reference: - MXZ-C Technical & Service Manual for detailed specifications and additional information per Indoor Unit Combination. - MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: Only 1 MVZ may be used on any system. When an MVZ is connected, total connected capacity must be 100% or less. When an MVZ is connected, no P-Series indoor units can be used (PCA, PLA, or PEAD). Notes:

MXZ-3C30NAHZ OPERATIONAL PERFORMANCE NON-DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) 1 6 1 9 1 12 1 15 1 18 1 24 2 12 2 15 2 30 2 30 2 30 2 33 2 36 2 33 2 36 3 18 3 21 3 24 3 24 Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C 6,000 - - 6,000 6 7,400 7,400 - - 9,000 9,000 - - 9 11,000 11,000 - - - - 12 14,400 14,400 - - 14,000 14,000 - - 15 - - 17,200 17,200 - - 18 21,600 21,600 - - 22,500 22,500 - - 24 22,600 22,600 - - 6,000 6,000-6 + 6 14,800 7,400 7,400-15,000 6,000 9,000-6 + 9 18,400 7,400 11,000-6,000-6 + 12 22,000 7,500 14,500-9,000 9,000-9 + 9 22,000 11,000 11,000-6,000 14,000-6 + 15 22,000 6,400 15,600-8,600 11,400-9 + 12 22,000 9,500 12,500-23,000 5,900 17,100-6 + 18 23,000 5,900 17,100-23,000 9,000 14,000-9 + 15 23,000 8,700 14,300-23,000 11,500 11,500-12 + 12 23,000 11,500 11,500-8,200 15,800-9 + 18 8,100 15,900-11,100 12,900-12 + 15 10,700 13,300-5,100 18,900-6 + 24 5,900 18,100-9,900 14,100-12 + 18 9,600 14,400 - - 15 + 15-6,900 17,100-9 + 24 7,900 16,100-8,300 15,700-12 + 24 9,300 14,700-10,800 13,200-15 + 18 10,900 13,100 - - 18 + 18-6,000 6,000 6,000 6 + 6 + 6 22,000 7,300 7,300 7,300 21,000 6,000 6,000 9,000 6 + 6 + 9 25,800 7,400 7,400 11,000 6,000 6,000 6 + 6 + 12 7,200 7,200 14,000 6,000 9,000 9,000 6 + 9 + 9 7,100 10,600 10,600 26,000 6,000 6,000 14,000 6 + 6 + 15 6,400 6,400 15,600 6,300 9,500 12,600 6 + 9 + 12 6,400 9,500 12,500

MXZ-3C30NAHZ OPERATIONAL PERFORMANCE, contd. # of indoor unit Total Nominal Capacity (x1000 Btu/h) 3 30 3 30 3 30 3 30 3 33 3 33 3 33 3 33 Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C 9,500 9,500 9,500 9 + 9 + 9 9,500 9,500 9,500 5,800 5,800 16,700 6 + 6 + 18 28,600 5,800 5,800 17,000 5,900 8,800 13,700 6 + 9 + 15 28,600 5,800 8,600 14,100 5,700 11,400 11,400 6 + 12 + 12 28,600 5,800 11,400 11,400 8,500 8,500 11,400 9 + 9 + 12 28,600 8,600 8,600 11,300 5,300 7,900 15,200 6 + 9 + 18 28,600 5,300 7,900 15,400 5,300 10,700 12,400 6 + 12 + 15 28,600 5,300 10,300 12,900 8,000 8,000 12,400 9 + 9 + 15 28,600 7,900 7,900 12,900 7,700 10,300 10,300 9 + 12 + 12 28,600 7,900 10,300 10,300 4,900 4,900 18,500 6 + 6 + 24 28,600 5,700 5,700 17,300 4,800 9,700 13,900 6 + 12 + 18 28,600 4,900 9,500 14,200 9,500 9,500 9,500 12 + 12 + 12 28,600 9,500 9,500 9,500 5,000 11,700 11,700 6 + 15 + 15 28,600 4,900 11,900 11,900 7,300 7,300 13,900 9 + 9 + 18 28,600 7,200 7,200 14,200 7,300 9,700 11,400 9 + 12 + 15 28,600 7,200 9,500 11,900

MXZ-3C30NAHZ OPERATIONAL PERFORMANCE, contd. DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) 1 9 1 12 1 15 1 18 1 24 2 33 2 30 2 36 2 30 2 33 2 36 3 30 3 33 3 33 Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C 9,000 9,000 - - 9 10,900 10,900 - - - - 12 13,600 13,600 - - 15,000 15,000 - - 15 - - 17,200 17,200 - - 18 21,600 21,600 - - 22,600 22,600 - - 24 - - 9,000 9,000-9 + 9 10,900 10,900-21,000 9,000-9 + 12 22,800 10,100 12,700-9,000 15,000-9 + 15 9,100 14,900-7,800 19,600-9 + 24 27,600 8,600 19,000 - - 12 + 12-8,200 15,800-9 + 18 8,000 16,000-10,700 13,300-12 + 15 10,300 13,700-9,900 14,100-12 + 18 9,300 14,700-9,500 17,900-12 + 24 27,600 10,000 17,600 - - 15 + 15-11,200 12,800-15 + 18 10,900 13,100 - - 18 + 18-27,000 9,000 9,000 9,000 9 + 9 + 9 9,100 9,100 9,100 8,200 8,200 11,000 9 + 9 + 12 27,600 8,500 8,500 10,600 7,500 7,500 12,500 9 + 9 + 15 27,600 7,600 7,600 12,500 7,500 10,000 10,000 9 + 12 + 12 27,600 7,900 9,900 9,900 9,100 9,100 9,100 12 + 12 + 12 27,600 9,200 9,200 9,200 7,000 7,000 13,400 9 + 9 + 18 27,600 6,900 6,900 13,700 6,900 9,100 11,400 9 + 12 + 15 27,600 7,100 8,800 11,700

MXZ-3C24NAHZ MXZ-3C30NAHZ DIMENSIONS: MXZ-3C30NAHZ Unit: inch (mm) Unit: inch (mm) Lock nut Conduit plate Top Conduit connector Conduit plate Under OBH702 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# MXZ-3C30NAHZ for Multiple Indoor Unit Styles - 201611