Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems

Similar documents
RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems

Lockshield valves with Pressfit connection Type RLV with isulation and regulation

Valve bodies type RA-N with integrated presetting

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

High capacity valve body, type RA-G

X-tra Collection for designer radiators and bathroom towel rails

X-tra Collection for designer radiators and bathroom towel rails

High Capacity Valve Body, Type RA-G

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

Pressure relief controller AVA (PN 25)

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Flow controller (PN 25) AVQ - return and flow mounting

Floor heating system, heating circuit with FHV-A in flow.

Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange

2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange

Flow-compensated temperature controller AVTQ DN 15

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Flow controller (PN 25) AVQ - return and flow mounting

FHV control valves are flexible to use, easily installed and are available in two versions:

Integrated valves Series 3

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

ASSEMBLY INSTRUCTIONS

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

Your Personal Catalog Temperature Controllers All our know-how - is now yours

V2000Kx KV type TRV Body

Mikrotherm F. Manual Radiator Valves With presetting

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)

Spare parts Pipesystems / Pre-Wall Installation Catalogue 01/2018.

V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Manual presetting valves LENO MSV-BD

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

RTL. Floor Heating Controller Return temperature limiter with and without presetting

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE

Automatic balancing valves ASV-PV DN (3rd gen.)

Thermostatic valve Type AVTA

Regutec F. Return Lockshield Radiator lockshield

k VS DN (mm) Connections ( C) (m 3 /h)

INT 4/15 Catalogue 2015/2016 We reserve the right to effect changes. System press tools. Piping technology

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

4-way Distribution Valve

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Thermostatically operated cooling water valves Type AVTA

Flow controller (PN 16, 25, 40) AFQ / VFQ 2(1) - return and flow mounting

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

Pressure operated water valve Type WVFX and WVS

VPI45..Q with pressure test points. Combi valves, PN 25

The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters.

Pressure independent balancing and control valve

2-position electric actuators with Ball valves VBZ ½...11/4

VE-S_15-32 Pressure Independent Balancing & Control Valves

Combi valves PN 16 with flanged connections

RADIATOR VALVE ACCESSORIES

611, 671. Diaphragm Valve, Metal

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Manual Presetting Valves LENO MSV-B

Please refer to our catalogue for details of the full product range

TRIM, TRIM A, RADITRIM A, TRIM K, STK, TA Loop

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT

Diaphragm Valve, Metal

HENCO TECHNICAL MANUAL 2006

Differential pressure controller AFP / VFG 2 (VFG 21)

Angle Seat Control Valve 7020

three-way mixing valve

2-Port and 3-Port Zone Valves, PN16

Globo P. Ball valves Pump ball valve made of gunmetal

611, 671. Diaphragm Valve, Metal

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

Assisted lift operated 2/2-way solenoid valves Type EV250B

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

Valencia Radiator Valve Range

Pressure independent balancing and control valve AB-QM DN

Thermostatic radiator valves with presetting

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

2-Port and 3-Port Zone Valves PN 16

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

3-Port Seat Valves with Male Thread, PN 16

Horizontal Distribution Units - HDU Multi-port

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

Diaphragm Valve, Metal

V Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Angle Seat Valve 7010

Transcription:

Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems EN 215 Application Straight Angle Horizontal angle The valve bodies with pressfit connection are used for heating systems with stainlass steel or copper pipes. The fitting require a commercial compression tool. List of available tools is found on page 2. The valve bodies are physically and technically identical to RA-N, DN15 standard valves. All RA 2000 thermostatic sensors, as well as the new RAX design series, may be used as desired. The RA-N valve bodies with integrated presetting are used in two-pipe pumped heating systems. Flow is adjustable in the range 0.04-0.73 m 3 /h. RA-N valve bodies are supplied with a red protective cap which can be used for manual regulation during the construction phase. The protective cap must not be used as a manual shut off device. A special manual shut off device (code no. 013G5000) should be used. Technical data are according to Euronorm EN 215. The valve bodies are equipped with a self sealing tailpiece featuring an O-ring seal. Valve bodies are manufactured from DZR brass with nickel plating. The pressure pin of the gland seal is of chrominium steel and works in a lifetime lubricated O-ring. The complete gland seal can be replaced without draining down the system. Should water treatment be used it is essential that dosing instructions of the manufacturer are strictly observed. It is recommended that formulations containing mineral oil are avoided. Ordering and data Type Code no. Design RA-N 15 3) 013G3237 013G3238 013G3239 Angle Straight Horiz. angle Connection Settings, k v values with RA 2000 sensor, m 3 /h 1) mal actuator With ther- Inlet Outlet Xp 1 2 3 4 5 6 7 N N(k vs ) Pressfit R½ Xp=1 0.04 0.09 0.15 0.22 0.28 0.33 0.36 0.43 0.90 Xp=2 0.04 0.09 0.16 0.25 0.36 0.43 0.52 0.73 0.90 1) The kv-value indicates the water flow (Q) in m 3 /h at a pressure drop ( p) across the valve of 1 bar; k v = Q: p. The k vs -value states the flow Q at a maximum lift, i.e. at fully open valve at setting N. At setting N the k v -value is stated according to EN 215, at Xp = 2K i.e. the valve is closed at 2 C higher room temperature. At lower settings the Xp value is reduced to 0.5 K of the setting value 1. 2) The maximum differential pressure specified is the maximum pressure at which the valves give satisfactory regulation. As with any device which imposes a pressure drop in the system, noise may occur under certain flow/pressure conditions. To ensure quiet operation, maximum pressure drop should not exceed 0.05-0.2 bar. The differential pressure can be reduced by the use of a Danfoss differential pressure regulator. Accessories Product Code no. Gland seal, may be exchanged with system in operation. O-Ring (5pcs.) 013G0290 013G4149 Approvals Danfoss Pressfit valves are tested and approved according to EN 215 (CEN). Pipes compatible with Danfoss pressfit valves are according to EN 10312 (welded stainless steel pipes ), EN 10305-3 (Thin-walled carbon steel pipes), EN 1057 (seemless copper pipes) with a minimum wall thickness of 1 mm. The O-rings used in the Danfoss pressfit valves bodies are according to EN 681. DKCD VDUZL402 Danfoss 02/2009 1

Presetting Presetting area Reference mark The calculated setting value can be set easily and accurately without using special tools: remove the protective cap or sensor. raise the setting ring. turn the scale on the setting ring until the desired value faces the reference mark, orientated towards the valve outlet. release the setting ring. Factory setting = N. N the valve is completely open. A setting in the shaded area must be avoided. When the sensor is mounted, the presetting is hidden and thus protected against unauthorized alteration. The presetting can be chosen from values between 1 and 7 with intervals of 0.5. At setting Press system Pipes Copper and stainless stell pipes which complies to EN 1057 or EN 10312. Steel pipes Outer diametre and pipe weight according to EN 10312, Table 2 for serie 2 steelpipes. Danfoss recommends a pipe weight of min. 1 mm. Carbon steel pipes Tubes in unalloyed steel E195(W.nr.1.0034) and E235(W.nr.1.0308) according to EN10305-2 or EN 10305-3 in condition +A or +N. Copper pipes Outer diametre and wall thickness according to EN 1057, Table 3. Danfoss recommends a minimal wall thickness of 1 mm. Pipe hardness min. R 290, meaning that only copper pipes in bars are compatible. No internal reinforcement is required. Compatibility The pressable area of Danfoss Pressfit valves are designed to match a range of commercial press tools and jaws as described in the table. For tools not mentined please check the with the manufacturer. Compatible press tools Press tools and jaws must be used and serviced as described by their manufacturer, and the actual press operation must be inspected. Danfoss require a minimal press force of 30 kn. The actual pressing must not be interrupted and the tool should be locked for removal until the pressing has been completed correctly. The testing of the press points is done according to the manufactures specs. Compatible press tools Geberit Mapress: PWH 75, EFP2, ECO1/ACO1, EFP3, AFP3, ACO 3 REMS: Power-Press E, Power-Press 2000, Power- Press (ACC), Akku-Press (ACC) Rothenberger: ROMAX Pressliner, ROMAX Pressliner ECO, ROMAX AC ECO SANHA: ECO201, ACO201, ACO3, ECO301 Viega: PT3-EH, PT3-AH, Picco, Typ 2 Novopress: AFP 101 RIDGID: CT-400, 320-E Klauke: UAP2, UNP2, UP2EL-14 Compatible press jaws Mapress Geberit: Press jaws15 mm (90532) REMS: V15 (570115), M15 (570110), SA15 (570935) Rothenberger: SV 15 mm (1.5212X), M 15 mm (1.5102X) SANHA: Standard, 15 mm (1692015, 1695815) Viega: PT2 15mm (Modell 2299.9, Typ 461 898) Novopress: M 15 RIDGID: ProPress 15 mm (16958) Klauke: KSP3 M15 mm, KSP4 V15 mm With system under pressure all pressfit connections should be inspected. Even if no leakage is seen the connection should be checked. 2 VDUZL402 Danfoss 02/2009 DKCD

Fitting 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. DKCD VDUZL402 Danfoss 02/2009 3

Capacity Capacities in combination with RA 2000 sensor at P band between 0.5 K and 2K. The P band is the change in room temperature which is required to move the valve from closed position to the position which allows the calculated flow. Sizing example: Required heat: 0.7 kw Cooling across radiator: 20 C. Flow through radiator: Q = 0.7 20 x 1.16 = 0.03 m 3 /h = 30 liter/h Pressure drop across valve: p = 1 mwg. Valve setting: 2.5 Alternatively the setting can be read directly in the table "Data and ordering": k v = Q (m 3 /h) p (bar) 4 VDUZL402 Danfoss 02/2009 DKCD

Design Materials in contact with water Valve body and other metal parts K v -limiter O-Ring Valve cone Pressure pin and valve spring Nozzle Ms 58, DZR brass PPS EPDM NBR Chrome steel PP The valve bodies are nickle-plated on the outside. 1. Gland seal 2. O-Ring 3. Pressure pin 4. Seal 5. Regulation spring 6. Setting dial 7. Valve body 8. Union nut 9. Nipple 10. Pressfit connection The radiator thermostats consist of the thermostatic elements of the RA 2000/RAX series and the valve body. The element and the valve body are ordered separately. Dimensions 57 ISO 7/1 - R1/2 28 29 58 SW24 SW 24 41 109 72 42 15 57 96 28 29 109 SW 24 41 Dimensions with RA 2990 or RAX thermostatic sensor. DKCD VDUZL402 Danfoss 02/2009 5

6 VDUZL402 Danfoss 02/2009 DKCD