Status Date Prepared Reviewed Endorsed Approved

Similar documents
Title Specification - Fuses for Railway Signalling Applications. Reference Number SPS 32 - (RIC Standard: SC SP)

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)

Reference Number PDS 18 - (RIC Standard: EP SP)

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

Australian/New Zealand Standard

Discipline: Engineering (Track & Civil) Category: Code of Practice. Clearances. Section 7. Applicability. ARTC Network wide.

Title Requirements for Electric Aerials Crossing ARTC Infrastructure. Reference Number PYS 02 - (RIC Standard: EP SP)

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

045 : 2000 CEB STANDARD

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Structural Requirements For Drawgear And Buffers On Railway Vehicles

Powermate Range pitch 7.00 Powermate Range pitch 7.00

Minimum Operating Standards for. Rolling Stock WOS 01

Crimpmate Range pitch 5.00

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

AS/NZS 3112:2004 AS/NZS

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

TERMINATION TECHNOLOGIES FOR HAZARDOUS AREAS A practical guide

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

High Voltage Operating Rods

Locomotive Hauled Passenger Vehicle Specific Interface Requirements WOS

Equipotential Bonding of Rail Vehicles to Running Rail Potential

Maintenance of Signal Sighting and Signals

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

This document is a preview generated by EVS

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Hydraulic fluid power Dimensions and requirements of quick-action couplings

Stud connection system HSK

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

FR circuit breaker - hydraulic magnetic,

This document is a preview generated by EVS

MDual Power Connector

ES5 Security Theory/Regulations Answer Schedule

AS/NZS :2013. Plugs and socket-outlets for household and similar purposes AS/NZS :2013

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Phase + Neutral, neutral on left side

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Guidance for Low Voltage Electrical Installations

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

DX³ RCCBs - ID 4P up to 100 A

INTERNATIONAL STANDARD

Class J modular ferrule and knifeblade fuse blocks

34-SDMS-02 SPECIFICATIONS FOR

SERIES 54 Inductive Proximity Sensor

Phase + Neutral, neutral on right side

introducing the new macey range of waterproof and flameproof connectors for the oil & gas industry

Powerline QC. Single Power Connectors. Ten 47 Limited

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

Design Standard. Purpose: Design Standard:

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33

AS/NZS 3131:2001 AS/NZS

FAKRA-Comliant SMB 50-Ohm Inline Connectors 27 JUN 11 Rev E

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

General Interface Requirements

TX³ RCCBs 2P up to 100 A

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T

Data sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX

A. Submit manufacturer's literature and technical data before starting work.

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

FAQ S. Main Switchboard Design Criteria. ENGINEERED SOLUTIONS FOR ALL YOUR SWITCHBOARD NEEDS

Rotary Disconnect Switches, Bulletin 194R

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

ENGINEERING SPECIFICATION

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

CONTA-CONNECT SUPPLEMENTS

Explosion protected terminal boxes type, GHG 72.

DOUBLE-LEVEL TERMINAL BLOCKS SRKD SSLD

Track Circuit Assister Configuration for Rail Vehicles

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas

HI-POT/CONTINUITY TESTER Model PLEP01

Electrak powertrack / underfloor busbar system

RX 3 M.C.B A up to 63 A

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

KINGDOM OF SAUDI ARABIA SAUDI STANDARDS AND QUALITY ORGANIZATION SASO SAUDI STANDARD. DRAFT No :2010

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

ype UP T Busplugs Low Voltage Switchboard Equipment

RX 3 M.C.B A up to 63 A

Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

Technical Specification for Pole Mounted Capacitor Rack

INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT

Model DS1000/DT20 System

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green

INTERNATIONAL STANDARD

Low Voltage Power Supplies in Electrified Areas

Transcription:

Discipline Engineering Standard NSW Category Signalling Title Specification - Solderless Terminals Screw and Spring Clamp Terminal Blocks Reference Number SPS 51 - (RIC Standard: SC 11 14 00 00 SP) Document Control Status Date Prepared Reviewed Endorsed Approved May 05 Standards and Systems Standards Engineer GM Infrastructure Strategy & Performance Safety Committee Refer to Reference Number H Olsen M Owens Refer to minutes of meeting 12/08/04

Disclaimer Australian Rail Track Corporation has used its best endeavors to ensure that the content, layout and text of this document is accurate, complete and suitable for its stated purpose. It makes no warranties, express or implied, that compliance with the contents of this document shall be sufficient to ensure safe systems of work or operation. Australian Rail Track Corporation will not be liable to pay compensation in respect of the content or subsequent use of this document for any other purpose than its stated purpose or for any purpose other than that for which it was prepared except where it can be shown to have acted in bad faith or there has been willful default. Document Approval The technical content of this document has been approved by the relevant ARTC engineering authority and has also been endorsed by the ARTC Safety Committee. Document Supply and Control The Primary Version of this document is the electronic version that is available and accessible on the Australian Rail Track Corporation Internet and Intranet website. It is the document user s sole responsibility to ensure that copies are checked for currency against the Primary Version prior to its use. Copyright The information in this document is Copyright protected. Apart from the reproduction without alteration of this document for personal use, non-profit purposes or for any fair dealing as permitted under the Copyright Act 1968, no part of this document may be reproduced, altered, stored or transmitted by any person without the prior written consent of ARTC. May 2005 Page 2 of 11

About This Standard This specification describes the general requirements for solderless screw and spring clamp type wire terminal blocks for use in wiring railway signal apparatus. This specification covers terminal blocks, which shall be suitable for both "DIN rail" mounting, and for surface mounting. May 2005 Page 3 of 11

Document History Primary Source RIC Standard SC 11 14 00 00 SP Version 2.0 List of Amendments ISSUE DATE CLAUSE DESCRIPTION 1.1 01/09/2004 Reformatting to ARTC Standard 1.2 14/03/2005 Disclaimer Minor editorial change 1.3 06/05/2005 All Document reformatted May 2005 Page 4 of 11

Contents 1. Introduction...6 2. Applicable Documents...6 2.1 ARTC Specifications...6 2.2 Australian Standards...6 2.3 International Standards...6 3. Definitions...6 4. General Description...7 5. Environmental Conditions...7 6. Service Conditions...8 7. Material...8 7.1 Insulating Material...8 7.2 Metallic Parts and Coating...8 7.3 Fire and Heat Characteristics...8 8. Types and Applications...8 8.1 Test - Disconnect Terminal (Link Type) Blocks...8 8.2 Test - Disconnect Terminal (Pin or KnifeType) Blocks...8 8.3 Feed Through Terminal Blocks...9 8.3.1 For Conductors to 70 sq mm...9 8.3.2 For Conductors over 70 sq mm...9 8.4 Fuse Terminal Blocks...9 8.4.1 Type 1...9 8.4.2 Type 2...9 8.4.3 Type 3...9 8.5 Earth Terminal Blocks...9 8.6 Surface Mounted Terminal Blocks...10 9. Mechanical Design and Testing 9.1 Surface Leakage...10 9.1 General Features...10 10. Electrical Requirements...10 11. Dielectric Properties, Current Leakage and Insulating Requirements...10 12. Identification and Marking...11 13. Labelling...11 May 2005 Page 5 of 11

1. Introduction This specification describes the general requirements for solderless screw and spring clamp type wire terminal blocks for use in wiring railway signal apparatus. This specification covers terminal blocks, which shall be suitable for both "DIN rail" mounting, and for surface mounting. 2. Applicable Documents 2.1 ARTC Specifications Specification SPS 06: Connectors for Signalling Interface. 2.2 Australian Standards This Specification refers to the following Australian Standards: AS 1125 Conductors in Insulated Electric Cables and Flexible Cords. AS 1147.1 Electrical Material for Coal Mines - Insulating Materials. Part 1: Materials for Insulating Power Conducting Components. AS 2420 AS 3000 AS 3013 AS 3100 Fire Test Methods for Solid Insulating Materials and Non-Metallic Enclosures Used in Electrical Equipment. SAA Wiring Rules. Electrical' Installations - Wiring Systems for Specific Applications. Approval and Test Specification - General Requirements for Electrical Equipment. AS 3169 Approval and Test Specification - Flat, Quick Connect Termination. 2.3 International Standards This Specification refers to the following International Standards: VDE 0607 BS 4579 AAR Part 14.1.2 Specifications for Clamps of Screwless Terminals for Connecting or Joining Copper Conductors from 0.5 mm ² up to 16 mm ². Specification for the Performance of Compression Joints in Electric Cable and Wire Connectors. Recommendations for Design Criteria and Operating / Functional Guidelines for Solderless Screw Clamp Type Terminal Blocks for Use in Wiring Signal Apparatus with Copper Wire Only. DIN 46277/EN Mounting Rail TS 32 3. Definitions For the purpose of this specification, the following definitions shall apply :- May 2005 Page 6 of 11

Vital Circuits Circuits directly involved in ensuring the safety of the signalling system. Non-Vital Circuits Circuits involved in the control and indication of the signalling system, but not directly connected with the safety functions. Dielectric Material which offers relatively high resistance to the passage of an electric current. Comparative Tracking Index The numerical value of the voltage corresponding to the asymptote to a curve produced from the results of tests carried out in accordance with this specification. Creepage Distance The shortest path between two conductive parts, or between a conductive part and the bounding surface of the equipment, measured along the surface of the insulating material. DIN Rail Mounting rail to DIN 46 277-1 (DIN 1) or DIN 46 277-3 (DIN 3) or NFC 63015 (DIN 3). 4. General Description Solderless clamp type terminal blocks are used for terminating wiring and cable with solid or multistrand conductors, for circuits rated up to 600 volts, to signal apparatus in weather-protected instrument and termination cases and housings. Conductor cross sectional areas range from 0.5sq mm to 300sq mm. All stranded conductors of less than 4sq mm cross sectional area shall be terminated with a pin type crimp lug or ferrule before insertion into the terminal. Dimensions of feed-through and disconnect terminals shall be sufficient to permit the uncrowded termination of a large number of stranded conductors, each of typically 3mm overall diameter insulation and fitted with a double insulated pin type crimp lug or ferrule and pre-printed identification sleeve. Except for earthing terminals and terminals for cable in excess of 70sq mm, the terminal block assembly shall be fully insulated with no exposed conductive parts. 5. Environmental Conditions Terminal blocks and accessories, including DIN rail shall be suitable for service under the following conditions: Temperature: -5 C to 85 C Relative Humidity: 0 to 95% Vibration: As detailed in Specification SPS 02 All non-metallic materials shall resist deterioration caused by ultraviolet light exposure. Exposure to dust, dirt, and moisture shall not cause deterioration of the terminal blocks. All materials shall be fungi growth resistant. May 2005 Page 7 of 11

6. Service Conditions All non-metallic materials shall resist, warping or softening in temperature up to 85 C and shall not become brittle in temperatures down to -5 C. All non-metallic materials shall resist deterioration due to contamination with petroleum products, common cleaners, water displacement films and vapours. All non-metallic materials shall be chemically inert with regard to the metallic components. 7. Material 7.1 Insulating Material Insulating material shall be Melamine, Polyamide 6 (PA6) or an equivalent with natural tracking resistance, KB > 600, as measured in accordance with DIN/VDE 0303 part 1. 7.2 Metallic Parts and Coating All metallic portions of the terminal block and terminal block assembly shall be either of corrosion resistant material or coated or electroplated to prevent corrosion. Coatings shall be of cadmium, zinc, chromium, lead, nickel, tin, and silver or tin/lead combination. All current carrying components shall be of copper or copper alloy. Cadmium and Zinc coating shall not be used on the current carrying parts. All threaded and clamping components and screws shall be of steel or stainless steel. 7.3 Fire and Heat Characteristics Materials shall be fire resistant and self-extinguishing upon removal of direct flame. Smoke and toxic gas propagation shall be minimised. Terminals shall be tested in accordance with the requirements of AS-2420 and AS- 3013 (or equivalent international standards) and test results shall be made available on request. 8. Types and Applications The following requirements relate to terminal blocks for mounting on DIN-rail. These terminal blocks may be used in non-vital and vital circuits rated up to 600 volts using single conductors and multi-strand conductors of 0.5 sq mm to 16 sq mm cross sectional area. 8.1 Test - Disconnect Terminal (Link Type) Blocks Terminal blocks with disconnect by slide link shall be used only for non-vital circuits. The sliding disconnecting device shall allow the circuit to be opened and closed without having to disturb the permanent wiring. Test probe sockets shall be provided to allow the easy connection of test or measuring instruments. The slide clamp shall be able to be actuated by a normal flat blade screwdriver. 8.2 Test - Disconnect Terminal (Pin or KnifeType) Blocks Disconnect pin type terminal blocks shall employ a multi-contact Beryllium Copper spring which ensures a high number of disconnect/connect operations whilst May 2005 Page 8 of 11

maintaining a low through resistance. The disconnect pin shall be able to be disconnected/withdrawn with the fingers to open or interrupt a circuit. The grip of the disconnecting pin shall be shaped to allow good grip and shall incorporate a coloured band, which remains visible until the pin is fully pushed home. Knife type disconnect terminal blocks shall be able to be opened by hand and, when opened, shall spring to the fully open position with no possibility of contact being made without positive pressure being applied to the disconnect link. The current capacity of these terminal blocks shall be 25A (unless otherwise specified) and the terminal block shall provide provision for permanent connection of two or more in parallel (bussing). Test probe sockets shall be provided to allow the easy connection of test or measuring instruments. 8.3 Feed Through Terminal Blocks 8.3.1 For Conductors to 70 sq mm Feed through terminal blocks for conductors to 70 sq mm cross sectional area shall be fully enclosed types with no exposed conductive parts. Clamping screws shall be operated by a flat bladed screwdriver and provision shall be made for bussing of terminals. 8.3.2 For Conductors over 70 sq mm Feed through terminal blocks for conductors 70 sq mm and over cross sectional area shall provide either bolts and nuts or studs and nuts for the termination of crimp lugs. The bolt or stud diameter shall be commensurate with the terminal cable capacity but shall not be less than M8. These terminals are not required to be fully enclosed. 8.4 Fuse Terminal Blocks Three types of fuse terminal blocks are required. Each type shall provide for bussing of multiple fuse blocks 8.4.1 Type 1 This type of fuse terminal block shall accept fuses with indicator to DIN 41576 (5x20mm). Fuse range 0.1 Amps to 6.3 Amps (250V). 8.4.2 Type 2 This type of terminal block shall accept fuses to DEF 59-96, 11/4in x 1/4 in, (32mm x 6.35mm) with current capacities from 1 to 16 Amps (250V). 8.4.3 Type 3 This terminal shall accept fuses with indicator to DIN 49522 (Neozed) ranging from 20 Amps to 63 Amps (440V) with the approximate fuse size of 15x36.5mm. 8.5 Earth Terminal Blocks The earthing terminal block shall provide positive electrical connection to the mounting rail. The form of the terminal block shall be similar to feed through terminal blocks. May 2005 Page 9 of 11

8.6 Surface Mounted Terminal Blocks Surface mounted terminal blocks (2, 3, 4, 6 10 or 12 way) shall be fitted with a clamp plate or spring. Terminals in which the clamp screw directly contacts the conductor are not acceptable. 9. Mechanical Design and Testing 9.1 Surface Leakage The surface leakage distance between any two adjacent terminals and between the two sides of a disconnect terminal, when the link (or pin) is open shall be at least 6 mm. 9.1 General Features All metallic and current carrying portions of the terminal shall be retained within the insulating and housing frame and irrespective of whether the wire or conductor clamping mechanism is tightened or not. The mechanical strength of the terminal block and the conductor clamping mechanism shall exceed the maximum force, which can be exerted by the clamping screws or spring. The clamping screw shall not directly make contact with the conductor. A captive clamping plate or similar, which cannot rotate, shall separate the screw and conductor. The clamping screw shall also be captive. The conductor clamping method shall be designed so that it will securely clamp the smallest multistranded conductor for which the terminal is rated without the possibility of individual strands becoming free. All surfaces shall be smooth as possible to minimise entrapment of dirt, dust and other contaminants. A positive mechanical locking mechanism shall be provided to lock the terminal block assembly to the rail, where mounting rail is used. Rail mounted terminals shall clip into place from the side of the rail. 10. Electrical Requirements The minimum value of insulation resistance between terminal to adjacent terminal or terminal to mounting rail shall be 100 M-Ohm when measured with a 500V DC insulation tester. Testing for the Comparative Tracking Index shall be performed in accordance with Appendix D of AS 2420 (or with an equivalent international standard). The Comparative Tracking Index shall be not less than 600. Creepage distances and clearances shall be in accordance with the values shown in Section 4 of AS 3100. 11. Dielectric Properties, Current Leakage and Insulating Requirements Dielectric properties shall be measured when the maximum size conductor, for which the terminal is rated, is terminated. Both volume and surface leakage currents shall be May 2005 Page 10 of 11

assessed. All tests shall be made at room temperature of 20 +/- 2 C with a relative humidity of 65 +/- 5%, by applying a 50 Hz 3,000 volt peak constant voltage test potential between the two points between which the volume and surface leakage current flow and flashover are to be measured. 1) The flashover test shall be made by applying the test potential for a period of one minute. The flashover resistance requirement shall be met if, after one minute current flow does not exceed one milliampere, and no evidence of insulation fracture or rupture is observed. 2) The leakage test shall be made by applying the test potential for one additional minute if the requirements of the flashover test have been met. The leakage test requirement shall be met if the leakage current does not exceed 1 x 10 the maximum rated amperage of the smallest cross sectional area conductor for which the terminal is rated. 12. Identification and Marking Each terminal block shall be identified and marked at manufacture, and shall include the following information: a) Manufacturer's name and identification mark. b) Type reference or catalogue number. c) Conductor size or range of conductor sizes. d) Recommended tightening torque for the clamp screw if relevant for a specific application. 13. Labelling A means shall be provided on the terminal block for attachment of numbering or labelling. The identification shall be firmly and securely attached to withstand all environmental and operating conditions and requirements. It shall be possible to remove, replace or change the identification without damage to the terminal block. May 2005 Page 11 of 11