XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

Similar documents
DIN Track Terminal Blocks with Screw Terminals XW5T

G3PE-Single-phase. Solid State Relays for Heaters

S8JX-N/S8JX-G Series Replacement Brackets

DIN Track Terminal Blocks with Screw Terminals

DIN Track Terminal Blocks with Screw Terminals XW5T

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

D4BS CSM_D4BS_DS_E_8_4

Dimension A. Dimension B

Better Productivity by Standstill and Low-speed Monitoring

D4GS-N CSM_D4GS-N_DS_E_7_2

A165E CSM_A165E_DS_E_11_2

Model Number Structure

2NC (slow-action) Direct. Model. opening

D4BL. Guard Lock Safety-door Switch

A22LK CSM_A22LK_DS_E_6_2

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

D4NH CSM_D4NH_DS_E_7_1

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

Digital display Pressure range ON/OFF output Linear output Model

2NC (slow-action) Direct. Model. opening

CSM_D4N-_R_DS_E_6_1

Redundancy Unit. Model Number Structure. Ordering Information. Model Number Legend. New Product. S8VK-R Series name

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Multiple Limit Switch

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

1,000 M min. (at 500 VDC)

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

A4EG CSM_A4EG_DS_E_6_1

Solid State Relays for Heaters

Smile 41 Push-button box with/without emergency stop

Tina 4A Connection block

Smile 11 RA/-B Smile 12 RF/-G Reset button

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Tina 11A Connection block

A3S. Pushbutton Switch Series with Square 40-mm Body. Lighted Pushbutton Switch (Square) List of Models

Pushbutton Switches 30-mm Pushbutton Switches Universal Design. Emphasis on Color Coding, Workability, and Safety.

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

Small-diameter Proximity Sensor

Tina 10A/B/C Adaptor unit

Safety Limit Switch

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

LED Signal Towers. Pre-assembled and pre-cabled in different aperture to highlight the processes. Features/Unique selling proposition

EStrong-series Emergency Stop

FMC-1/2 Tina Muting unit

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Safety Guard Switching Unit G9SX-GS

D4BL. Guard Lock Safety-door Switch

Sense7-series Non-contact coded safety switch

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

D4NL CSM_D4NL_DS_E_9_2

A22E. Model Number Structure. Emergency Stop Switch. Model Number Legend. Completely Assembled. Install in 22-dia. or 25-dia.

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Solid State Relays for Heaters G3PJ

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

Solid State Relays for Heaters

Eden AS-i Proximity safety sensor

20250 Module Installation Guide

MKey9-series Safety Interlock Switch with Guard Locking

37SCENE 46SCENE 79SCENE

A22TK Key-type Selector Switch with Direct Opening Mechanism

GRADE 3 TUBULAR LOCKSETS INDEX:

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

Solid State Relays for Heaters G3PJ

HPx-JDx3-xx HARNESS INSTALLATION

A22. Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) Pushbutton Switch (Cylindrical 22/25-dia.) List of Models

Losi (LOSB9810) 2400mAh 11.1V LiPo Transmitter Battery for JR Z1, KoPropo Helios, and Other Radios of Similar Battery Configuration

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

D4SL-N /

AC/DC Powered Peak Detection Fast Charger for 4- to 8-Cell Ni-Cd & Ni-MH Batteries

Submersible Pond Pump with UV 800 Gallons Per Hour

Guardian NV Flywheel Coupling

Female Plug. connecting to Fuel Quantity

30100 Module Installation Guide L

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

Guardian FBA Flywheel Coupling

Manual Transfer Switch

SOARER TT BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

CM52 Network Protector with Arc Flash Reduction Module

GLYCOL SYSTEM MONITOR (GSM)

Stellar 4 Clutch Manual

LEXION SINGLE FUNCTION HYDRAULIC VALVE KIT

SUPRA JZA80 TWIN TURBO BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

Type Flexair Pneumatic Pressure Control Valves

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

TONS. Before each shift: Before operating: Before initial operation of hoist:

15100 Module Installation Guide Mercedes EPA07 w/dpf

GERINGHOFF. Corn Header Manual f HEADSIGHT.COM

Transcription:

Common Terminals XW2R-COM CSM_XW2R-P_M_B-COM_DS_E Space-saving and less wiring work of power supply wiring are achieved. Common wiring is already wired on the PCB, transition wiring is unnecessary. Wiring is completed by one action. Models available with +,,+ Mix. Application Example for Each terminal connected by PCB. Bus-bar and transition wiring are unnecessary. for Connection Examples PLC Connection cable (XW2Z) Power supply Common Terminal XW2R-P40@D-COM Connector terminal conversion unit for signal (XW2R-@34GD-C@) Model list X W 2R - P 40 @ D - COM Wiring metho P Push-in spring Terminal number of poles Type of connector P + Common M Common B + Mix D DIN Track mounting COM Provided

XW2R Ordering Information Appearance Specification Number of poles Model + Common terminal Common terminal 40 + Mix terminal Ratings and Specifications Rated current Rated voltage Insuration resistance Ambient operating temperature Applicable wires Applicable wire sizes Stripped length 0A(Unit total) 25VDC/240VAC 00MΩmin. (at 500VDC) 0 to 55 C Ferrule:AWG24 to 4 (0.2mm 2 to 2mm 2 ) Stranded or solid wire:awg 28 to 4 (0.08mm 2 to 2mm 2 ) (Outer diameter of insulation must be 4 mm max) AWG28-6: 8 to 0 mm AWG4: 9 to 0 mm Details on Crimp Terminals Applicable Ferrules Use ferrules of the lengths and thicknesses specified below.if other lengths or thicknesses are used, connection maynot be possible or it may not be possible to insert or remove the posts. Ferrule Dimensions Square ferrules Round ferrules Dimension A (Width) Dimension B (Height) Dimension C (Diameter) Square ferrules B 8-0 mm A Round ferrules Dia. C 2.7 mm max. The cross-sectional area after crimping must be 2 mm max. 4.8 mm 2 or less 2 mm dia. max. (after crimping) 8-0 mm Refer to page 3 for information on Square/Round ferrule and use tool. Dimensions 64.4 The label contents depend on the model. (33.) 50 9.7 Wiring Diagram XW2R-P40PD-COM XW2R-P40MD-COM XW2R-P40BD-COM Label Contents XW2R-P40PD-COM Upper + + + + + + + + + + Lower + + + + + + + + + + XW2R-P40MD-COM Upper Lower XW2R-P40BD-COM Lower Upper + + + + + + + + + + 2 3 4 5 6 7 8 9 0 2 3 4 5 6 7 8 90 2 3 4 5 6 7 8 90 2 3 4 5 6 7 8 90 2

Safety Precautions XW2R Precautions for Correct Use Wiring Precautions Do not perform wiring work, remove connectors, or connect connectors while power is being supplied. Electric shock or damage to the device may result. Double-check all wiring before turning ON the power supply. After wiring, route the cable so that force is not applied directly to the connections. Wires for Terminal Blocks Do not damage the cores when stripping the insulation from them. Always twist stranded wires together before connecting them. Do not presolder wires. It may not be possible to connect them or remove them. XW2R-P@@ type (Square/Round ferrule) Type of terminal Manufacturer Size Recommend ferrule Recommend crimp tool Square ferrule Round ferrule Phoenix Contact Weidmuller Nichifu AWG24 AWG22 AWG20 AWG8 AWG6 AWG4 AWG24 AWG22 AWG20 AWG8 AWG6 AWG4 AWG22- AWG6 Note: @@ of ferrule model is for color (Ex: YE = Yellow) AI0.25-8@@ AI0.34-8TQ AI0.5-0WH AI0.5-8WH AI0.75-0GY AI0.75-8GY AI.5-0BK AI2.5-8BU H0.25/2 H0.34/2 H0.5/4 H0.75/4 H.5/4 H2.5/5D TGV TC-.25-9T When an electric wire is connected directly (J,E,P type) CRIMFOX6 PZ6 roto NH NH32 NH65 a Model XW2R-J@@ XW2R-E@@ XW2R-P@@ Strip length a 9 mm 7 mm AWG28-6: 8 to 0 mm AWG4: 9 to 0 mm Mounting Units to and Removing Units from DIN Track Mounting Procedure Removal Procedure 2 Press. Hook.. Hook the Unit on the DIN Track. 2. Press the Unit onto the DIN Track to secure it.. Insert a flat-blade screwdriver into the DIN Track lock. 2. Move the screwdriver like a lever to free the lock. 3

XW2R Connecting Spring cramp Terminals Using Ferrules How to insert wire How to release wire Release hole Terminal holes The wire should be pushed into the terminal block till stopping. Insert the screwdriver into the release hole and pull out the ferrule. Using Stripped Wires Inserting and Removing Wires Insert the screwdriver into the release hole, and the wire should be inserted into the wire insertion hole, and then pull out the screwdriver. Inserting Wires. Press the a flat-blade screwdriver diagonally into the release hole. Press at an angle of 0 to 5. If you press in the screwdriver correctly, you will feel the spring in the release hole. Removing Wires. Press the flat-blade screwdriver diagonally into the release hole. Press at an angle of 0 to 5. If you press in the screwdriver correctly, you will feel the spring in the release hole. Release hole 0 to 5 0 to 5 2. Leave the flat-blade screwdriver pressed into the release hole and insert the stranded wire or the solid wire into the terminal hole. Insert the stranded wire or the solid wire until the stripped portion is no longer visible to prevent shorting. 2. Leave the flat-blade screwdriver pressed into the release hole and pull out the wire. 2 Stranded wire/solid wire 3. Remove the flat-blade screwdriver from the release hole. 3 2 Wire 3. Remove the flat-blade screwdriver from the release hole. 3 4

XW2R Precautions for Safe Use Do not press the flat-blade screwdriver straight into the release hole. Doing so may break the terminal block. When you insert a flat-blade screwdriver into a release hole, press it down with a force of 30 N max. Applying excessive force may damage the terminal block. Do not tilt or twist the flat-blade screwdriver while it is pressed into the release hole. Doing so may break the terminal block. Make sure that all wiring is correct. Do not bend the cable forcibly. Doing so may sever the cable. Use tool Select a use tool from following table. Model Use tool Specialized tool and dimension XW2R-J@@ Phillips screwdriver JIS#2 XW2R-E@@ XW2R-P@@ Model XW4Z-00B Model XW4Z-00B Head of screwdriver Is 0.4 x 2.5mm max. Bending Radius of Connecting Cables To prevent damaging the Connecting Cables, use the following minimum bending radii as guidelines. XW2Z - @ @ @ @ @ End of model number BF-L, EE-L, FF-L A EE B, D, K, L, N Minimum bending radius 66 mm 67.2 mm 83 mm 88 mm For checking electrical continuity XW2R-E@@ type: There is no elecrical continuity in the screw, Please confirm it at hole for confirming continuity or wiring part. 5

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 205. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 205 All Right Reserved.