DIGITAL EARTH RESISTANCE Model KM 2030

Similar documents
4-20mA DC PROCESS CLAMP METER

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

SOIL RESISTIVITY TESTER

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

RTD CALIBRATOR Mode KM-CAL-720

ANALOG INSULATION RESISTANCE TESTER

HIGH VOLTAGE PROXIMITY DETECTOR

TEMPERATURE CALIBRATOR Model KM-CAL-801

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

DIGITAL 4 WIRE EARTH RESISTANCE TESTER

OPERATING INSTRUCTION

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Tachometer. English. Users Manual

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

i400s Calibration Information Introduction

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

TMD90A Dual Input Digital Thermometer

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Digital Low Resistance Ohm Meter

Infrared Thermocouple Probe

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Calibration Manual. Detachable Jaw True-rms Clamp Meter

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

KMP7010. Ground Resistance Tester. Users Manual

362 Clamp Meter. Users Manual

Model Battery Powered Milliohm Meter

Users Manual. Phase Rotation Indicator

362 Clamp Meter. Users Manual

365 Detachable Jaw True-rms Clamp Meter

PY-11 Voltage & Continuity Tester


323/324/325 Clamp Meter

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

P5510. Users Manual. Pneumatic Comparison Test Pump

OPERATING INSTRUCTION

User's Manual. Earth Ground Resistance Tester. Model Introduction

INSP-3 Wiring Inspection Tester

TACH-10 Contact / Non-Contact Tachometer

KMP Insulation-Continuity Tester. Users Manual

302+/303 Clamp Meter. Users Manual

Temperature Calibrator

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

233 True-rms Remote Display Digital Multimeter Safety Information

TIME-10 Process Control Stopwatch

373 Clamp Meter. Users Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

OPERATING INSTRUCTIONS. TempCheck Non-Contact Infrared Thermometer IRT200 F C + -

Electrostatic Fieldmeter

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

80PK-2A Type K Immersion Probe

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Users Manual. MegOhmMeter

Table of Contents Title Page No.

2-Pack Indoor/Outdoor Simulated Security Cameras. Owner s Manual

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Electric Chainsaw Sharpener With Bar Mount

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

THWD-3 and TH-3 Relative Humidity and Temperature Meters

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

110 Volt/12 Volt Portable Inflator

TMA5 Mini Vane Anemometer

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

Dawson DDM190D. Digital Multimeter User s Manual

Clamp Earth Tester MET-2. Instruction Manual

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

MegOhmMeter. Users Manual

Instruction Manual VT25 / VT28 VOLTAGE TESTER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

3000RS PRECISION RESISTANCE STANDARD 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

Phase Sequence Tester

OPERATING INSTRUCTIONS

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

Hydraulic Bead Breaker Kit

Instruction Manual. IM-191 Magnetic Field Meter

ATD-5540 Digital Automotive Engine Analyzer/Multimeter Owner s Manual

Visit us at

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL

EA / 10 / 50 Clamp Coil Adapter. Operation Manual. Version 1.00 April 2007 All product names are trademarks of their respective companies

i3000s/i2000 Flex AC Current Probe

For technical questions and replacement parts, please call

5.2 PRE-OPERATION PROCEDURE WARRANTY

Safety design conforming to the following provisions

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Transcription:

An ISO 9001:2008 Company GENERAL SPECIFICATIONS : DIGITAL EARTH RESISTANCE Model KM 2030 Display : 3½ Digit LCD display. Ground resistance measurements from 0 ~ 01Ω to 2000Ω with 0.01Ω resolution. Earth Resistance : 20Ω / 200Ω / 2000Ω Accuracy : 20Ω : ± (2% + 0.1Ω); Earth Voltage : 0 ~ 30V Accuracy : ± (3% + 5) Resolution : 0.01Ω Working LED Indicator. Data Hold Function. Response Time : Withstand Voltage : AC 1500V An ISO 9001:2008 Company 200Ω / 2000Ω : ± (2% + 3) Measure earth resistance, about 5 seconds. Measure Earth Voltage, about 2 seconds. Low battery indication. Power : AA 1.5V X 6 & 12V x 1 Battery. Weight : approx. 680g. Dimension : 150(L) x 100(W) x 70(D) mm. Standard Accessories : Test Wires, Earth wire, Auxiliary Earth Bars, Instruction Manual, Battery & Carrying Case. Preliminary Data All Specifications are subject to change without prior notice G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct.: 022-24156638, Tel. : 022-24124540, 24181649, Fax : 022-24149659 Email : kusam_meco@vsnl.net Website : www.kusamelectrical.com D:\Chhaya\My Documents\Chhaya\backup\catlog\New Cat\2015 new arrival catalogs\km 2030.cdr (DY4100)

LIST OF PRODUCTS Digital Multimeter Digital AC & AC/DC Clampmeter AC Clamp Adaptor AC/DC Current Adaptor Thermo Anemometer Thermo Hygrometer Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood, Paper & Grain Moisture Meter Transistorised Electronic Analog & Digital Insulation Resistance Testers(upto 10 KV) Digital Sound Level Meter & Sound Level Calibrator Digital contact & Non-contact Type Tachometer Digital Non-contact (infrared) Thermometer Maximum Demand Controller/Digital Power Meter Digital Hand Held Temperature Indicators AN ISO 9001:2008 COMPANY Digital Earth Resistance Tester MODEL - KM 2030 G 17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : (022) 24156638 Tel. : (022) 24124540, 24181649. Fax : (022) 24149659 Email : kusam_meco@vsnl.net Website : www.kusamelectrical.com www.kusam-meco.co.in OPERATION MANUAL

TABLE OF CONTENTS TITLE PAGE NO. A. Introduction... 01 B. Safety Rules and Precaution... 01-02 C. Performance Features... 02 D. Technical Indicators... 03 E. Operation Diagram...... 03 F. Operation Instruction... 04-06 G. Replacing Battery... 07 H. Accessories... 07 I. Test Certificate... 08 J. Warranty... 09 WARRANTY Each KUSAM-MECO product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of goods. In case any defect occurs in functioning of the instrument, under proper use, within the warranty period, the same will be rectified by us free of charges, provided the to and fro freight charges are borne by you. This warranty extends only to the original buyer or end-user customer of a KUSAM-MECO authorized dealer. This warranty does not apply for damaged Ic s, fuses, burnt PCB's, disposable batteries, carrying case, test leads, or to any product which in KUSAM-MECO s opinion, has been misused, altered, neglected, contaminated or damaged by accident or abnormal conditions of operation or handling. KUSAM-MECO authorized dealer shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM-MECO. KUSAM-MECO s warranty obligation is limited, at option, free of charge repair, or replacement of a defective product which is returned to a KUSAM- MECO authorized service center within the warranty period. THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. KUSAM-MECO SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE WHATSOEVER. All transaction are subject to Mumbai Jurisdiction. 09

MUMBAI TEST CERTIFICATE Digital Earth Resistance Tester This Test Certificate warrantees that the product has been inspected and tested in accordance with the published specifications. The instrument has been calibrated by using equipment which has already been calibrated to standards traceable to national standards. MODEL NO. KM-2030 SERIAL NO. DATE: ISO 9001 REGISTERED 08 QC KUSAM-MECO PASS A General Introduction Digital Earth Resistance Tester is a new generation tester for electrician practice which is developed by our company in recent years. The circuit, structure and technique of traditional earth resistance tester have been improved and the new design is both fine-looking and practical. This one has more complete functions, higher accuracy, more convenient and reliable for operation and more suitable for outdoor use with dust and wet proof structure It can test earth resistance of various earth systems including power systems, electric equipments, lightning conductors as well as resistance value of low resistance conductor and AC voltage test. B Safety Rules 1. Please read this manual carefully before use. 2.It should not be used before placing the back cover back to avoid risk of electric shock. 3. Please do not touch lead terminal and circuit under test to avoid electric shock. 4. Please make sure the range select switch setting within the proper range before test 5. Make sure the coupler plug of lead inserted in the terminal tightly. 6. When the tester is wet, do not use it or replace battery. 7. Please do not turn the switch during test. 8. Please do not test in flammable places since sparkles may cause explosion. 01

v v v 9. Please stop use when metal is exposed due to breakage of casing or testing wire. Make sure the isolation skin of testing wire is intact before use. 10. Please make sure the testing wire has been removed from testing terminal and the range select switch is on off position before replacing battery. 11.Please make sure the range select switch is on off position after use. 12. Replace battery when - + shown on tester or the battery indicator light is off to ensure testing accuracy. Please remove the battery if not use it for long time. C. Performance Features 1.Measuring range of earth resistance : 0-2000 W 2.Measuring range of earth voltage : 0-30VO 3. LED green light indicates normal operating mode O 4.3 digit LCD display for more direct and convenient reading O 5. - + on LCD indicates deficiency of 12V battery. LED red light off indicates deficiency of 1.5V battery. 6. Response time : measure earth resistance, about 5 seconds. Measure earth voltage, about 2 seconds. 7. Withstand voltage : AC 1500V, 1minute between circuit and outer casing. 8. Overload protection: on earth voltage, can withstand 300V AC (1 minute). on earth resistance, can withstand 200V AC (10 seconds) 9. Power supply, 1.5V 6 AA batteries, 12V 1 battery (23A) 10. Dimensions : 150 x 100 x 70mm. 11. Weight: about 680g (including battery). 12. Working environment : Working temperature : 0 C 40 C relative humidity 80% Storage temperature : -10 C 50 C relative humidity 85% Ensure accurate temperature : 23 C + - 5 C relative humidity 75% 02 re: earth resistance of common earth electrode of commercial electric power system, etc. Re: reading value of instrument earth resistance. G. Replacing Battery 1) Do not open the battery cover if the outer casing is wet. 2) Please do not replace the battery during test. Please turn the range switch to off and remove testing leads, control bar, etc before replacing the battery to avoid electric shock. Undo the screw on battery cover at the bottom of the unit and open the battery cover. Put into a new battery, put battery cover back and tighten the screw H. Accessorie 1) assistant earth bar: 2 bars 2) testing wire: 1 set ( including red testing wire 15 meters each, yellow testing wire 10 meters each and green testing wire 5 meters each) 3) simple testing wire 1 set (including: red testing wire 1.6 meters each and green testing wire 1.6 meters each) 4) 1.5V(R6AA) battery 6pcs 5) 12V(23A) battery 1pcs 6) instruction manual 1 pcs 07

7-3 Simple measuring method of earth resistance The method is designed for places where assistance earth bar cannot be punched. Use a earth electrode with quite small earth resistance like metal water pipe, common earth electrode of commercial electric power system, earth end of building, etc to substitute assistant earth bar P and C. 1) Connecting testing wires. Please connect simple testing wires according to picture below. D Technical Indicators Earth resistance Rang Accuracy Resolution 20 W +- 2% rdg+0.1 W 0.01W 200 W 2000 W Earth Voltage +- 2% rdg+3 dgt W 0.1W 1W Rang Accuracy Resolution 30V +- 10% rdg+15 dgt 0.1V E. Operation Diagram 1 earth electrode 2 secondary 3 transformer 4elernentary Risk: be careful of electric shock when using commercial electric system earth method for test. Please do not use this tester to measure supply voltage. 2) Measuring earth voltage Please turn the range select switch to earth voltage. Make sure the voltage value below 10V since error may occur to measuring value of earth voltage if the voltage value above 10V. At this point, one can break the power supply of tested earth electrode equipment to lower earth voltage and then measure the value. 3) Measuring earth resistance First please press "Test/Stop" beginning from 1000 Q. If the show value is too small, switch to 200n /20 Q and the show value here is namely the tested earth resistance value. Note: when measuring current is about 2mA, even the residual current circuit breaker cannot take effect. Calculate the real earth voltage value RX by equation below: RX=RE re 1. LCD display 2. E port (earth electrode) 3. P port (electric potential pole) 4. C port (current pole) 5. V port (voltage pole) 6. Function switch. 7. HOLD data holding switch 8. TEST testing button 9. POWER power indicator light (red) 10. OK operation indicator light (green) 06 03

F. Operation Instruction a. Check battery voltage No - + symbol on LCD indicates sufficient 12V battery. - + symbol on LCD means you need replace 12V battery according to instruction. B. Routine method for testing earth resistance Risk :! maximum 50V voltage may be generated between E-C or E-P terminals when testing earth resistance! Please do not touch testing lead to avoid electric shock. Please make sure testing wire plug insert in testing terminal thoroughly before testing since loose connection may cause error in testing result. 1. Connecting testing wire: As shown in picture below, punch assistant earth bar P1and C1 in eart 5 to 10 meters distant from tested earth substance; connect green wire to terminal E, yellow wire to terminal P and red wire to terminal C. Note: please place assistant earth bar in land with high water content. You need add water in dry land, sand land or land containing crushed stones to maintain humidity of inserting position of earth bar. Lie earth bar flat and add water when meeting cement ground and cover wet towel, ect on earth bar before testing, 2. Working power and connecting wire testing Press Test/Stop, POWER light off indicates insufficient 1.5V battery. Please replace it. OK light on indicates normal connecting of lead and P, C terminals and earth resistance of assistant earth within permitted range. If light is off, check the lead connecting P and C terminals or change the position of earth bar, or water the land to lower assistant earth resistance to a proper level. Check breakage by short circuit of spring clamps of red and yellow lead ends. 3. Measuring earth voltage: Please turn the range select switch to earth voltage. Make sure the voltage value below 10V since error may occur to measuring value of earth voltage if the voltage. In the picture, E connect earth electrode poet P connect electric potential pole port C connects voltage pole port V connects voltage pole port 04 In the picture, E connects earth electrode port P connects e I ectr i c potent i a 1 pole port C connects cur rent po I e port V connects vo I tage po I e port value above 10V. At this point, one can break the power supply of tested earth electrode equipment to lower earth voltage and then measure the value. 4) Measuring earth resistance First please press "Test/Stop" beginning from 20000. If the show value is too small, switch to 2000 /20.Q and the show value here is namely the tested earth resistance value. Note: make sure connecting wires separated during wire connecting since testing when testing leads wind about with each other may encounter mutual inductance to affect reading. The assistant earth resistance value may be too big and error may occur to show value. Make sure assistant earth bar P and C into wet land and complete contact of connecting parts 05