Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Similar documents
Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Acoustic Twin Fans (ATQ)

Mixed Flow Roof Fans (RMH)

Sabre Plate Mounted Sickle Fans (VSP)

Square Mixed Flow Fans (MFQ)

Vent-Axia Sabre Sickle Roof Fans (VSR)

Mixed Flow Roof Fans (RMH)

NEW Acoustic In-Line Fans (ACQ)

Bifurcated Case Axial Fans (BIFA)

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Performance. Sound Levels. Impellers. Motors. Accessories

Sentinel D-Box Twin Fan

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Sentinel D-Box Single Fan

NEW Slimpak EC Box Fan (SLPT EC)

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

HIGH TEMPERATURE TWIN SQUIF FANS

Access Rectangular In-Line Fans (ARH)

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

ifan Copford Box Range

ACOUSTIC CABINET FANS CVB / CVT Series

AC Commercial Fans Edition. ErP ready

Features: Available in horizontal and vertical units

supplied in Form (B) configuration. Airflow over Impeller- Motor.

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

Uniclass L7534. Manufacture controlled to ISO9001

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Axial fans. What s more, non-stock models are normally available within two weeks.

TWINFLOW STDR Product Brochure

QUBE SQU-HT(S) Product Brochure

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

BOX BLB Centrifugal Box Fan

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

QUIETSCROLL TWIN FAN RANGE

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

VORTICENT C E RANGE Centrifugal fans

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

SQUIF HIGH TEMPERATURE FANS

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

AXIAL FANS Catalogue CN0050C01 May 2008

BIFURCATED AXIAL FLOW FANS

CHMT Series, F Rated Fans

Unobox units with backward curved centrifugal impellers

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

NCF fans 50 Hz. Protection class IP 55

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

Plate mounted axial flow fans HXBR / HXTR Series

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS

Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9")

MAJAX-2 GENERAL SPECIFICATION

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

CYCLONE F 400 smoke extraction casing

KV sileo 100 M. Circular duct fans. Circular duct fans

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

Max. airflow m 3 /s Diam. min. Diam. max

Single Phase Electronic Speed Controllers

GigaBox centrifugal fans Product specific information

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

QC RANGE ACOUSTICALLY LINED SINGLE BOX FANS PUREAIR KENT LTD ERP 2015 COMPLIANT

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

NALTF & NALTRF Belt Drive Roof and Plantroom Twinfans

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

DXP 100 Air Cooled Condenser

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

Section 4. Axial Fans - Section 4

BATHROOM EXTRACT FANS DECOR-100 Series

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

Fan - Powered Terminal Unit Series Flow

REVOLUTION SLCX Product Brochure

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

COMPACT Series type HCFB / HCFT (Plastic impellers)

ROOFMASTER STEF-HT ROOF FAN

NCF 60 Hz. Protection class IP 55

Medium Pressure Centrifugal Fans

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

ACOUSTIC CABINET FANS CVAB / CVAT Series

AXUS HIGH TEMPERATURE AXIAL FANS

Short casing. Long casing (L version) Commercial premises

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX

Transcription:

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features and Benefits In-line, Belt Driven, compact centrifugal twin fan. High Quality Heavy Gauge Galvanised Steel Casing. Optional IP65 Service Isolator Motor Insulation Class F. Maximum operating temperature 4 C. Manufacture controlled to BS EN ISO 91. Performance tested to BS 848 Part 1 & 2. The GDB Galaxy In-line Belt Driven, Twin fan range represents the latest development from Vent-Axia in high performance, run and standby twin fan. Designed to be controlled in-conjunction with Vent-Axia Trakmaster twin fan controller range, the total package offers the end user flexibility when interfaced with or without a (BMS) Building Management Systems, such as manual selection, 12/24hr auto changeover ensuring the extended life of the fan and motor, night setback during low levels of occupancy, for energy management control during 24hr extraction. The unit casing is manufactured from Heavy Gauge Galvanised Steel fitted with inlet and outlet discharge spigots. Individual gravity return shutters are fitted as standard to prevent air re-circulation through the standby or the system during shut down periods. Galaxy Duct Mounting Belt Driven Twin Fans are suitable for horizontal mounting only. Assembly controlled to BS EN ISO 91. To meet COSHH requirements, double pole service isolator switches are available. With access to the fan section via an easily removable access panel from the top of the unit, for cleaning and maintenance during shut down periods. The Galaxy range is available in four models with extract performance ranging from.2m 3 /s up to 2.5m 3 /s (72m 3 /h to 9m 3 /h), with pressure characteristics of up Pa. Fan/Motor Assembly Galaxy GDB belt driven fans are double inlet double width, forward curved centrifugal fans belt driven by totally enclosed fan ventilated, wound to suit 22-24V/1/5HZ or 38-415V/1/5Hz electrical supply. Protected to IP54, against dust and water jets complying with BS EN 6529:1992. Motor insulation Class F as a minimum, suitable for operating temperatures up to +4 C. Both the fans and motors are mounted on a steel frame, with anti-vibration mounts between the frame and casing and a flexible connection between the fan scroll and fan plate, minimising vibration. All belt driven Galaxy units are supplied with metric pulleys to ISO 4183 and wedge belts to ISO 4184 and DIN 7753. Electrical All Motors are available in either single phase 22-24V 5 Hz capacitor start and run or three phase 38V-415V 5Hz. Sounds Levels Fan sound levels are measured in a reverberant chamber in accordance with BS848 Part 2 1985. Published db(a) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 1-5 Pa (2 micro-pascal). The inlet and outlet sound power level spectra figures are db with a reference of 1-12 Watts (1 pico-watt). To ensure minimum noise levels during speed control, an auto transformer speed control is recommended Quality Assurance Design and manufacture are in accordance with the standard for quality management system BS EN ISO 91:1994. Selection Procedure Plot your specified duty on the above graphs. Select motor size and fan speed required. The full Stock Ref. No. for your unit will comprise of the unit size, motor rating, supply and fan speed. MOTOR S IZES :.37 = C.55 = D.75 = E 1.1 = F 1.5 = G 2.2 = H 3. = J 4. = K Typical Stock Ref. No.: Galaxy Range Duct Mounting Belt Drive Unit Size Voltage 1 = 23V/1 Ph/5Hz 3 = V/3 Ph/5Hz GDB 1/C/3/16 Motor Size Fan Speed (see opposite) (RPM) Example: Duty required =.35m 3 /s @ 15Pa Unit Size = GDB1 Supply = 3Ø From above graph (GDB1): Speed=16rpm Motor=.37 Stock Ref. No. will be: GDB1/C/3/16 29 T: 844 856 591

Twin Fans GDB1 Pa.55.75 3 2 1.37 1 1 13 12 11 18 17 16 19 21 2 22 23 1.1 1.5.1.2.3.4.5.6.7.8 m 3 /s Size r.p.m dbw 63 125 25 1k 2k 4k 8k dba @ 3m GDB1 12 71 64 66 65 65 64 61 58 52 5 GDB1 13 73 66 68 67 67 66 63 6 54 52 GDB1 1 75 68 7 69 69 68 65 62 56 54 GDB1 1 76 69 71 7 7 69 66 63 57 55 GDB1 16 78 71 73 72 72 71 68 65 59 57 GDB1 17 79 72 74 73 73 72 69 66 6 58 GDB1 18 8 73 75 74 74 73 7 67 61 59 GDB1 19 82 75 77 76 76 75 72 69 63 61 GDB1 2 84 77 79 78 78 77 74 71 65 63 GDB1 21 86 79 81 8 8 79 76 73 67 65 GDB1 22 88 81 83 82 82 81 78 75 69 67 GDB1 23 9 83 85 84 84 83 8 77 71 69 W: www.vent-axia.com 291

Galaxy In-Line Belt Driven Twin Fans (GDB) GDB2 Pa 6.75 1.1.55 16 1.5.37 1 3 12 13 1 2 1 9 11 1 7 6 8.2.4.6.8 1. 1.2 1.4 m 3 /s Size r.p.m dbw 63 125 25 1k 2k 4k 8k dba @ 3m GDB2 6 68 61 63 6 6 58 56 55 48 45 GDB2 7 7 63 65 62 62 6 58 57 5 47 GDB2 8 73 66 68 65 65 63 61 6 53 5 GDB2 9 75 68 7 67 67 65 63 62 55 52 GDB2 1 77 7 72 69 69 67 65 64 57 54 GDB2 11 79 72 74 71 71 69 67 66 59 56 GDB2 12 82 75 77 74 74 72 7 69 62 59 GDB2 13 84 77 79 76 76 74 72 71 64 61 GDB2 1 86 79 81 78 78 76 74 73 66 63 GDB2 1 88 81 83 8 8 78 76 75 68 65 GDB2 16 9 83 85 82 82 8 78 77 7 67 292 T: 844 856 591

Twin Fans Pa 7 GDB3 6 1.1 1.5 2.2 3. 4..75 1.37.55 13 3 11 1 12 9 2 8 1 7 6.5 1. 1.5 2. 2.5 m 3 /s Size r.p.m dbw 63 125 25 1k 2k 4k 8k dba @ 3m GDB3 69 62 63 61 6 63 58 54 51 48 GDB3 6 73 66 67 65 64 67 62 58 55 52 GDB3 7 75 7 69 67 66 69 64 6 57 56 GDB3 8 8 73 74 72 71 74 69 65 62 59 GDB3 9 83 76 77 75 74 77 72 68 65 62 GDB3 1 86 79 8 78 77 8 75 71 68 65 GDB3 11 88 81 82 8 79 82 77 73 7 67 GDB3 12 9 83 84 82 81 84 79 75 72 69 GDB3 13 92 85 86 84 83 86 81 77 74 71 GDB3 1 94 87 88 86 85 88 83 79 76 73 W: www.vent-axia.com 293

Galaxy In-Line Belt Driven Twin Fans (GDB) GDB4 Pa 6.55.75 1.1 1.5 2.2 3. 1 3 8 9 2 6 7 1.5 1. 1.5 2. 2.5 3. m 3 /s Size r.p.m dbw 63 125 25 1k 2k 4k 8k dba @ 3m GDB4 72 65 66 65 64 61 6 58 53 49 GDB4 75 68 69 68 67 64 63 61 56 52 GDB4 6 79 72 73 72 71 68 67 65 6 56 GDB4 7 83 76 77 76 75 72 71 69 64 6 GDB4 8 86 79 8 79 78 75 74 71 67 63 GDB4 9 88 81 82 74 8 77 76 74 69 65 GDB4 1 9 83 84 83 82 79 78 76 71 67 Fan Dimensions (mm) 7.5 25 5 x 5 x 5 support angles B 5 C 5 E A G F 18 D 25 Plan View Unit A B C D E F Weight Kg GDB1 48 85 1 65 25 11 125 GDB2 54 11 1175 762 35 116 175 GDB3 675 125 145 9 135 21 GDB4 765 1 145 1 457 153 27 294 T: 844 856 591

Twin Fans Accessories **ITC **ITC-DS Man/Auto 12/24hr Auto RSC Remote IP65 Isolator Standard Insulated Changeover Changeover Visual Starter (Factory fitted) Unit Unit Controller Controller Indicator + Overload Mounting Bracket Stock Ref. Stock Ref. KW Stock Ref. Stock Ref. Stock Ref. Stock Ref. Stock Ref. Stock Ref. GDB1 GDBI1.37 *13142 131421 131422 444744+44472 55GDB1MB 71ISOL4 GDB1 GDBI1.55 *13142 131421 131422 444744+44473 55GDB1MB 71ISOL4 GDB1 GDBI1.75 *13142 131421 131422 444744+44473 55GDB1MB 71ISOL4 GDB1 GDBI1 1.1 *13142 131421 131422 444744+44475 55GDB1MB 71ISOL4 GDB2 GDBI2.37 *13142 131421 131422 444744+44472 55GDB1MB 71ISOL4 GDB2 GDBI2.55 *13142 131421 131422 444744+44473 55GDB1MB 71ISOL4 GDB2 GDBI2.75 *13142 131421 131422 444744+44473 55GDB1MB 71ISOL4 GDB2 GDBI2 1.1 *13142 131421 131422 444744+44475 55GDB1MB 71ISOL4 GDB2 GDBI2 1.5 ACO/9.-15./1 - - 444744+44476 55GDB1MB 71ISOL4 GDB3 GDBI3.37 13142 131421 131422 444744+44472 55GDB3MB 71ISOL4 GDB3 GDBI3.55 13142 131421 131422 444744+44473 55GDB3MB 71ISOL4 GDB3 GDBI3.75 13142 131421 131422 444744+44473 55GDB3MB 71ISOL4 GDB3 GDBI3 1.1 13142 131421 131422 444744+44475 55GDB3MB 71ISOL4 GDB3 GDBI3 1.5 *13142 131421 131422 444744+44476 55GDB3MB 71ISOL4 GDB3 GDBI3 2.2 *13142 131421 131422-55GDB3MB 71ISOL4 GDB3 GDBI3 3 *13142 131421 131422-55GDB3MB 71ISOL4 GDB3 GDBI3 4 ACO/9.-15./1 - - - 55GDB3MB 71ISOL4 GDB4 GDBI4.55 *13142 131421 131422 444744+44473 55GDB3MB 71ISOL4 GDB4 GDBI4.75 *13142 131421 131422 444744+44473 55GDB3MB 71ISOL4 GDB4 GDBI4 1.1 *13142 131421 131422 444744+44475 55GDB3MB 71ISOL4 GDB4 GDBI4 1.5 *13142 131421 131422 444744+44473 55GDB3MB 71ISOL4 GDB4 GDBI4 2.2 *13142 131421 131422 444744+44473 55GDB3MB 71ISOL4 GDB4 GDBI4 3 *13142 131421 131422 444744+44474 55GDB3MB 71ISOL4 GDB4 GDBI4 4 ACO/9.-15./1 - - 444744+44476 55GDB3MB 71ISOL4 * Auto changeover Controllers will require 2 x D.O.L. Starters for each installation. **Not suitable for use with edemand controllers. For compatible changeover panel, see Accessories and Controllers Section NOTE: Weatherproof treatment for GDB models is available, please enquire. Units include anti vibration mounts & flexible connections internally, as standard. Electrical Data Motor Motor Nominal V/3Ph/5Hz Rating Speed F.L.C. S.C. r.p.m Amps Amps*.37 1 1.2 4.73.55 1 1.7 8.5.75 1 2.1 9.5 1.1 1 3.25 13.75 1.5 1 3.9 2.7 2.2 1 5.3 28.2 3 1 7 37.2 4 1 9.5 52.65 Motor Motor Nominal 23V/1Ph/5Hz Rating Speed F.L.C. S.C. r.p.m Amps Amps*.37 1 2.7 14.55 1 3.6 18.75 1 5 25 1.1 1 7 35 1.5 1 1 5 * D.O.L. Start FLC = Full load current SC = Starting current W: www.vent-axia.com 295