Figure 1. Two and Three-phase MagneX.

Similar documents
Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

PROTECTION AND CONTROL

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

Product Selection Guide

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

NX indoor current-limiting fuses

3.2. Current Limiting Fuses. Contents

CSP Circuit Breaker Three Phase

How to Use Coordinaide to Protect Transformers Against Secondary-Side Arcing Faults.

Edison modular fuse, vault application products

K-Limiter high ampere Companion II fuse

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

X-Limiter full-range current-limiting fuse

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Effective March 2015 Supersedes S August 2012

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

Technical Specification for Pole Mounted Capacitor Rack

Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C

PD-Series Ground Fault Circuit Protection

CATALOG. Hi-Tech Fuse Products

Section 1 Introduction to the Presentation

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

ELF -LR current-limiting fuse

INSTALLATION PRODUCTION TESTS

A 1.2 kv class externally removable secondary bushing

25 kv class fused loadbreak elbow connector

8.3kV, 9.9kV, 15.5kV, 17.2kV and 23kV Cooper ELSP Backup Fuses Testing per C

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses

Two-position sidewall (horizontal) and cover (vertical) mounted loadbreak switches

S&C Loadbuster Disconnects

SECTION PADMOUNT TRANSFORMER - OIL FILLED

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

Electromagnetic Industries LLP

Elastimold & Hi-Tech Fuse Products

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

1500 kva Padmount Transformer delta Primary Voltage 208Y/120 Secondary Voltage

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Expulsion Fuses. 2.2 Fuse Selection. 2.3 Application. 2.4 BA Type Fuses. 2.5 DBA Type Fuses. 2.6 DBU Type Fuses. 2.7 RBA and RDB Type Fuses

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

Mica Element Support. Compacted Quartz Sand. Length B

distribution transformers. Single-Phase Overhead GENERAL. Cooper Power Systems manufactures a complete line of single-phase overhead-type

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Technical Specification For Outdoor Substation Harmonic Filter Banks

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products

General Purpose Buck - Boost Wiring Diagrams... 86

Chapter 6 Generator-Voltage System

Molded Current-Limiting Fuse

Elastimold. Cable Accessories. Underground Distribution Switchgear. Molded Vacuum Switches and Fault Interrupters

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Horizontal Circuit Switchers

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

600 A 35 kv class BT-TAP deadbreak connector

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

Distribution Transformers

your Green Power WIND POWER SOLUTIONS only Greener

Solid Dielectric, Single Phase Recloser

Motor Protection. Voltage Unbalance & Single-Phasing

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

600 A 25 kv class BT-TAP deadbreak connector

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

Disconnect & ByPass Switches

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

GROUP D. Switch & Protective device.

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

Horizontal Circuit Switchers

SECTION MOTOR CONTROL

Company Directive STANDARD TECHNIQUE : TP4B/2. Relating to 11kV and 6.6kV Transformer Protection

Distribution Transformers

ELASTIMOLD & HI-TECH FUSE PRODUCTS

MAGNETIC MOTOR STARTERS

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

GENERAL. CONSTRUCTION External

FX Full-Range Current-Limiting Fuse

Solid Dielectric, Three Phase Reclosers CATALOG VS11

SWITCHGEAR DIVISION PRODUCT PROFILES

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

Compact Integrated Distribution Substation (CIDS)

Figure 1. ELSG Current-Limiting fuses. TABLE 1 Maximum Interrupting Current (rms symmetrical) INSTALLATION

Transcription:

Fusing Equipment Two- & Three-Phase MagneX Interrupter Electrical Apparatus 240-33 GENERAL The Cooper Power Systems MagneX Interrupter is an overcurrent protective device that protects distribution transformers from damaging overloads and secondary faults, and is also used for switching the transformer on or off. As a transformer protective device, the MagneX Interrupter combines safety and efficiency with economic operation. It is an integral assembly, which does not use a troublesome linkage or require calibration, making installation and operation fast and trouble free. The housing is made of an ultraviolet stabilized, high-strength, glass-filled thermoplastic material. The operating shaft is sealed against leakage with a double-viton O-ring seal. ELECTRICAL RATINGS TABLE 1 Voltage Ratings and Characteristics kv Amps Impulse 1.2 x 50 Microsecond Wave 150 60 Hz, 1 Minute Voltage Withstand 50 Continuous Current Rating 42 Switching Load Currents 42 TABLE 2 Interrupting Rating Voltage RMS RMS kv-lg Symmetric Asymmetric (A) (A) (A) 8.3 2800 4200 15.5 1500 2250 23.0 500 750 APPLICATION The three-phase MagneX Interrupter combines the functionality of three Bay-O-Net fuses and one three-phase on/off loadbreak switch into one protective device. This allows transformer manufacturers more flexibility in application of the product and potentially reduces the space Figure 1. Two and Three-phase MagneX. required to install the device on the transformer front plate. This product is ideal for three-phase pad-mounted transformer applications. The two-phase MagneX Interrupter is designed for single-phase applications where disconnecting both primary coil leads is desirable. This feature is ideal for two-bushing transformers, where a fault on either leg of the transformer may cause activation of the protective device. Secondary faults and overloads will trip the MagneX Interrupter open. However, the device can be reset once the condition is corrected. The MagneX Interrupter, in coordination with either an isolation link or current-limiting fuse, also clears primary faults. The MagneX Interrupter can also be used as a primary switch to disconnect the transformer windings not just the load. This eliminates core (no-load) losses on transformers not in service. Residual voltage problems associated with secondary breakers during banking of transformers are also eliminated. THREE-PHASE MAGNEX OPERATION Figure 2 demonstrates the circuit diagram for the three-phase MagneX Interrupter with single-phase sense, single-phase trip. The three-phase MagneX with single-phase sense, single-phase trip contains one sensors per phase. It reacts to fault currents on one phase and will cause tripping of that phase only. The MagneX then can be reset via the single operating handle by opening all three phases and closing all phases back in simultaneously. June 2004 New Issue Printed in U.S.A. Figure 2. Three-phase MagneX, single-phase sense, single-phase trip. 1

Two- & Three-Phase MagneX Interrupter Figure 3 demonstrates the circuit diagram for the three-phase MagneX Interrupter with single-phase sense, three-phase trip, containing one sensor in two of the three phases. This product should only be applied to delta-connected primary transformers, where any fault current flow in one phase will also flow in an adjacent phase. It reacts to fault currents on one phase and will cause tripping of all three phases. The MagneX then can be reset via the single operating handle by opening all three phases and closing all phases back in simultaneously. The three-phase MagneX with single-phase sense, three-phase trip should always be used in series with at least one backup currentlimiting fuse in each of the threephases. The backup current limiting fuses (see ELSP catalog section 240-50) provide high-current interruption capability. Figure 4 shows the circuit diagram for the two-phase MagneX Interrupter. The two-phase MagneX was specifically designed for single-phase, two bushing transformers, where disconnection of both bushings is desired following fault/overload detection. The MagneX will react to a fault sensed in either leg of the transformer primary. Interruption takes place in both interruption chambers simultaneously, disconnecting both legs of the transformer from the circuit. OPTIONAL HANDLE ASSEMBLIES A standard handle, as shown in Figures 5, is typically used in overhead poletype transformers. It is also used in underground pad-mounted transformer applications. The MagneX handle is reversible to enhance functionality and provide for optimal orientation of the handle in pad-mounted transformer applications. It is made of an ultraviolet stabilized high-strength, glass-filled thermoplastic material. The lower slotted portion of the handle is made of a flexible ultraviolet stabilized elastomeric material. The handle requires five pounds (2.27 kg) of force to operate manually. It allows flexibility for excessive force during operation. Figure 3. Three-phase MagneX, single-phase sense three-phase trip. Figure 4. Two-phase MagneX Interrupter. OPTIONAL HANDLE ORIENTATION MOVEMENT SWING 2.15" (54.6 mm) Ø 2.1" (54 mm) 6.32" (160.6 mm) CONNECTION POINT FOR ISOLATION LINK (2 PHASE ONLY) OR ELSP (PARTIAL RANGE CURRENT-LIMITING) FUSE (2 OR 3 PHASE) 4.40" (111.7 mm) 2.97" (75.3 mm) 4.52" (114.8 mm) 3.75" (95.3 mm) 6.20" (157.5 mm) SNAP RING HANDLE NUT TANK WALL HANDLE SHOWN IN STANDARD ORIENTATION.19" (4.8 mm) GASKET 1.85" (46.9 mm) 6.52" (165.61 mm) 1.53" (38.9 mm) 13.11" (LENGTH OF 2 PHASE) (333 mm) 19.70" (LENGTH OF 3 PHASE) (500.4 mm).32" (8 mm) Figure 5. MagneX assembly front/side/back views (with standard handle hardware kit). Note: Dimensions given are for reference only, inches (mm) 2

240-33 INSTALLATION The MagneX Interrupter is mounted under-oil on the primary side of the transformer. No special tools are required. The MagneX assembly is mounted through the transformer wall. The incoming high voltage lead is connected first to the isolation link or to the current-limiting fuse and then to the MagneX. The coil lead is then connected to the lower MagneX connection point (See Figure 8). Refer to Installation Instructions S240-33-1 for details. OPTIONAL HANDLE ORIENTATION MOVEMENT SWING Figure 6. Open/Closed handle positions (Standard positions shown). 2.25" (57 mm) 4.52" (114.8 mm) 3.75" (95.3 mm) 6.20" (157.5 mm) HANDLE IN STANDARD OPEN POSITION Figure 7. Tank mounting hole detail. STANDARD HANDLE ORIENTATION MOVEMENT SWING HANDLE IN STANDARD CLOSED POSITION 1.125" (28.5 mm) 0.156" rad. (4 mm) Note: Exterior mounting surface extending 1 / 2 " outward from the tank hole outer edge shall be flat and clear of surface obstructions. Figure 8. Lead connection points. PRODUCTION TESTS Tests are conducted in accordance with Cooper Power Systems requirements. 100% Physical Inspection 100% Electrically Tested to Meet Minimum Trip and Maximum Trip Clear TCC Curves Periodic Fluoroscopic Analysis (X-ray) ORDERING INFORMATION The three-phase MagneX Interrupter is available in two design variations. The first is a single-phase sense, single-phase trip version, for wye-connected transformers. This design is ideal for applications where customers desire fault sensing on one phase and tripping on that phase only. This option can be used with either an isolation link (recommended as a minimum) or backup currentlimiting fuse. The second three-phase MagneX design option is a single-phase sense, three-phase trip version, for delta connected transformers. This design is well suited for three-phase delta connected transformer applications (this design should NOT be used on wye-connected transformer primaries). The three-phase MagneX Interrupter with single-phase sense, threephase trip should always be used with backup current-limiting fusing. CONNECTION POINT FOR ISOLATION LINK (2 PHASE ONLY) OR ELSP (PARTIAL RANGE CURRENT LIMITING) FUSE (2 OR 3 PHASE) [THE HIGH VOLTAGE LEAD (FROM BUSHING) IS CONNECTED TO THE OTHER END OF THE ISOLATION LINK OR ELSP FUSE] CONNECTION POINT BETWEEN MAGNEX AND CORE COIL For three-phase delta primary connected transformers, use Table 3 to determine the correct MagneX sensor size and the appropriate ELSP backup current-limiting fuse required for the application. Use Table 7 to determine the exact MagneX catalog number. For three-phase wye primary connected transformers, use Table 4 to determine the correct MagneX sensor size and the appropriate ELSP backup current-limiting fuse required for the application, or refer to Table 6 for the appropriate isolation link. Use Table 7 to determine the exact MagneX catalog number. For the two-phase MagneX, refer to Table 5 to determine the correct MagneX sensor size for the application. Use Table 6 to determine the appropriate isolation link, or Table 9 to determine the appropriate ELSP backup current-limiting fuse for the application. Use Table 7 to determine the exact MagneX catalog number. NOTE: When ordering a MagneX Interrupter, the standard handle kit and hardware must be ordered separately. See Table 8 for the appropriate handle and hardware kit catalog number. 3

Two- & Three-Phase MagneX Interrupter TABLE 3 3-Phase MagneX Recommendations for Transformers with Delta Connected Primary Windings (Single-Phase Sense, Three-Phase Trip) Transformer Assumed Recommended kva Primary Minimum MagneX Recommended Rating Voltage Impedance Sensor ELSP 45 2.4 1.60% E18 3543125M71M 75 2.4 1.60% E25 3543150M71M 112.5 2.4 1.80% E40 3543125M71M x 2 150 2.4 2.00% E50 3543150M71M x 2 45 4.16 1.60% E10 3543080M71M 75 4.16 1.60% E18 3543125M71M 112.5 4.16 1.80% E25 3543150M71M 150 4.16 2.00% E30 3543165M71M 225 4.16 3.00% E50 3543125M71M x 2 100 6.6 1.80% E12 3543100M71M 160 6.6 2.00% E18 3543125M71M 200 6.6 2.00% E25 3543150M71M 250 6.6 3.00% E30 3543165M71M 400 6.6 4.00% E50 3543125M71M x 2 45 7.2 1.60% E06 3543050M61M 75 7.2 1.60% E10 3543080M71M 112.5 7.2 1.80% E12 3543100M71M 150 7.2 2.00% E18 3543125M71M 225 7.2 3.00% E25 3543125M71M 300 7.2 3.50% E30 3543150M71M 500 7.2 4.00% E50 2543125M71M x 2 100 11.0 1.80% E10 3543080M71M 160 11.0 2.00% E12 3543080M71M 200 11.0 2.00% E18 3543125M71M 250 11.0 3.00% E18 3543125M71M 400 11.0 4.00% E30 3543150M71M 500 11.0 4.00% E40 3543125M71M x 2 630 11.0 4.00% E50 3543125M71M x 2 45 12.0 1.60% E03 3543030M61M 75 12.0 1.60% E06 3543030M61M 112.5 12.0 1.80% E10 3543065M61M 150 12.0 2.00% E12 3543080M71M 225 12.0 3.00% E18 3543100M71M 300 12.0 3.50% E25 3543100M71M 500 12.0 4.00% E30 3543150M71M 750 12.0 5.75% E50 3543165M71M 45 13.2 1.60% E03 3543030M61M 75 13.2 1.60% E06 3543050M61M 112.5 13.2 1.80% E10 3543065M61M 150 13.2 2.00% E10 3543065M61M 225 13.2 3.00% E12 3543080M71M 300 13.2 3.50% E18 3543100M71M 500 13.2 4.00% E30 3543150M71M 750 13.2 5.75% E40 3543165M71M 100 15.0 1.80% E06 3544050M61M 160 15.0 2.00% E10 3544065M61M 200 15.0 2.00% E12 3544080M71M 250 15.0 3.00% E18 3544100M71M 400 15.0 4.00% E25 3544100M71M 500 15.0 4.00% E30 3544125M71M 630 15.0 4.00% E40 3544125M71M x 2 800 15.0 5.75% E50 3544125M71M x 2 100 20.0 1.80% E06 3544050M61M 160 20.0 2.00% E10 3544065M61M 200 20.0 2.00% E10 3544065M61M 250 20.0 3.00% E12 3544080M71M 400 20.0 4.00% E18 3544100M71M 500 20.0 4.00% E25 3544100M71M 630 20.0 4.00% E30 3544125M71M 800 20.0 5.75% E40 3544125M71M 1000 20.0 5.75% E50 3544150M71M 100 22.0 1.80% E06 3544050M61M 160 22.0 2.00% E06 3544050M61M 200 22.0 2.00% E10 3544065M61M 250 22.0 3.00% E12 3544065M61M 400 22.0 4.00% E18 3544080M71M 500 22.0 4.00% E18 3544100M71M 630 22.0 4.00% E25 3544125M71M 800 22.0 5.75% E30 3544125M71M 1000 22.0 5.75% E40 3544150M71M 1250 22.0 5.75% E50 3545165M71M 4

240-33 TABLE 3 (Continued) 3-Phase MagneX Recommendations for Transformers with Delta Connected Primary Windings (Single-Phase Sense, Three-Phase Trip) Transformer Assumed Recommended kva Primary Minimum MagneX Recommended Rating Voltage Impedance Sensor ELSP 45 24.9 1.60% E01 3544030M61M 75 24.9 1.60% E03 3544030M61M 112.5 24.9 1.80% E03 3544030M61M 150 24.9 2.00% E06 3544050M61M 225 24.9 3.00% E10 3544050M61M 300 24.9 3.50% E12 3544065M61M 500 24.9 4.00% E18 3544100M71M 750 24.9 5.75% E25 3544100M71M 1000 24.9 5.75% E30 3544125M71M 1500 24.9 5.75% E50 3545165M71M 45 27.6 1.60% E01 3545030M61M 75 27.6 1.60% E03 3545030M61M 112.5 27.6 1.80% E03 3545030M61M 150 27.6 2.00% E06 3545050M61M 225 27.6 3.00% E06 3545050M61M 300 27.6 3.50% E10 3545050M61M 500 27.6 4.00% E18 3545080M71M 750 27.6 5.75% E25 3545080M71M 100 30.0 1.80% E03 3545030M61M 160 30.0 2.00% E06 3545050M61M 200 30.0 2.00% E06 3545050M61M 250 30.0 3.00% E10 3545050M61M 400 30.0 4.00% E12 3545080M71M 500 30.0 4.00% E18 3545080M71M 630 30.0 4.00% E18 3545100M71M 800 30.0 5.75% E25 3545100M71M 100 33.0 1.80% E03 3545030M61M 160 33.0 2.00% E06 3545040M61M 200 33.0 2.00% E06 3545050M61M 250 33.0 3.00% E10 3545050M61M 400 33.0 4.00% E12 3545080M71M 500 33.0 4.00% E18 3545080M71M 630 33.0 4.00% E18 3545080M71M 800 33.0 5.75% E25 3545080M71M 1000 33.0 5.75% E30 3545100M71M 45 34.5 1.60% E01 3545030M61M 75 34.5 1.60% E03 3545030M61M 112.5 34.5 1.80% E03 3545030M61M 150 34.5 2.00% E03 3545040M61M 225 34.5 3.00% E06 3545040M61M 300 34.5 3.50% E10 3545050M61M 500 34.5 4.00% E12 3545080M71M 750 34.5 5.75% E18 3545080M71M 1000 34.5 5.75% E25 3545100M71M Notes: MagneX recommendations based on Minimum trip curves, and Maximum trip and clear curves, R240-91-302. Deration factor of 0.5% per degree C above ambient (25 C). Allowable loading greater than 140% for four hours in accordance with ANSI /IEEE C57.91.1981 Guide for Loading Distribution Transformers, Table 6. MagneX/ELSP coordinations based on coordination requirements of single-phase sense, three-phase trip version MagneX interrupter. Proper coordination requires delta connected transformer primary. Proper protection requires that a backup current-limiting fuse be used in series with each MagneX interruption chamber. DO NOT USE AN ISOLATION LINK WITH THE TRHEE-PHASE MAGNEX. Failure to use backup current-limiting fuse in series with the MagneX can result in an unprotected phase. Backup current limiting fuse may be rated for line-to-neutral voltage, as the three-phase MagneX is three-phase rated. Added backup protection can be achieved using phase-to-phase rated backup current-limiting fuse. 5

Two- & Three-Phase MagneX Interrupter TABLE 4 3-Phase MagneX Recommendations for Transformers with WYE Connected Primary Windings (Single-Phase Sense, Single-Phase Trip) Transformer Assumed Recommended kva Primary Minimum MagneX Recommended Rating Voltage Impedance Sensor ELSP 45 2.4 1.60% E18 3543080M71M 75 2.4 1.60% E25 3543125M71M 112.5 2.4 1.80% E40 3543165M71M 150 2.4 2.00% E50 3543125M71M x 2 45 4.16 1.60% E10 3543050M61M 75 4.16 1.60% E18 3543080M71M 112.5 4.16 1.80% E25 3543100M71M 150 4.16 2.00% E30 3543125M71M 225 4.16 3.00% E50 3543150M71M 100 6.6 1.80% E12 3543065M61M 160 6.6 2.00% E18 3543100M71M 200 6.6 2.00% E25 3543100M71M 250 6.6 3.00% E30 3543100M71M 400 6.6 4.00% E50 3543150M71M 45 7.2 1.60% E06 3543030M61M 75 7.2 1.60% E10 3543050M61M 112.5 7.2 1.80% E12 3543065M61M 150 7.2 2.00% E18 3543080M71M 225 7.2 3.00% E25 3543100M71M 300 7.2 3.50% E30 3543030M71M 500 7.2 4.00% E50 3543150M71M 100 11.0 1.80% E10 3544050M61M 160 11.0 2.00% E12 3544050M61M 200 11.0 2.00% E18 3544080M71M 250 11.0 3.00% E18 3544080M71M 400 11.0 4.00% E30 3544100M71M 500 11.0 4.00% E40 3544125M71M 630 11.0 4.00% E50 3544150M71M 45 12.0 1.60% E03 3544030M61M 75 12.0 1.60% E06 3544030M61M 112.5 12.0 1.80% E10 3544050M61M 150 12.0 2.00% E12 3544050M61M 225 12.0 3.00% E18 3544065M61M 300 12.0 3.50% E25 3544080M71M 500 12.0 4.00% E30 3544100M71M 750 12.0 5.75% E50 3544125M71M 45 13.2 1.60% E03 3544030M61M 75 13.2 1.60% E06 3544030M61M 112.5 13.2 1.80% E10 3544050M61M 150 13.2 2.00% E10 3544050M61M 225 13.2 3.00% E12 3544050M61M 300 13.2 3.50% E18 3544065M61M 500 13.2 4.00% E30 3544100M71M 750 13.2 5.75% E40 3544100M71M 100 15.0 1.80% E06 3544040M61M 160 15.0 2.00% E10 3544050M61M 200 15.0 2.00% E12 3544065M61M 250 15.0 3.00% E18 3544080M71M 400 15.0 4.00% E25 3544100M71M 500 15.0 4.00% E30 3544100M71M 630 15.0 4.00% E40 3544125M71M 800 15.0 5.75% E50 3544150M71M 100 20.0 1.80% E06 3545040M61M 160 20.0 2.00% E10 3545050M61M 200 20.0 2.00% E10 3545050M61M 250 20.0 3.00% E12 3545065M61M 400 20.0 4.00% E18 3545080M71M 500 20.0 4.00% E25 3545100M71M 630 20.0 4.00% E30 3545100M71M 800 20.0 5.75% E40 3545125M71M 1000 20.0 5.75% E50 3545150M71M 100 22.0 1.80% E06 3545030M61M 160 22.0 2.00% E06 3545040M61M 200 22.0 2.00% E10 3545050M61M 250 22.0 3.00% E12 3545050M61M 400 22.0 4.00% E18 3545080M71M 500 22.0 4.00% E18 3545080M71M 630 22.0 4.00% E25 3545100M71M 800 22.0 5.75% E30 3545100M71M 1000 22.0 5.75% E40 3545125M71M 1250 22.0 5.75% E50 3545150M71M 6

240-33 TABLE 4 (Continued) 3-Phase MagneX Recommendations for Transformers with WYE Connected Primary Windings (Single-Phase Sense, Single-Phase Trip) Transformer Assumed Recommended kva Primary Minimum MagneX Recommended Rating Voltage Impedance Sensor ELSP 45 24.9 1.60% E01 3544030M61M 75 24.9 1.60% E03 3544030M61M 112.5 24.9 1.80% E03 3544030M61M 150 24.9 2.00% E06 3544040M61M 225 24.9 3.00% E10 3544050M61M 300 24.9 3.50% E12 3544050M61M 500 24.9 4.00% E18 3544080M71M 750 24.9 5.75% E25 3544080M71M 1000 24.9 5.75% E30 3544100M71M 1500 24.9 5.75% E50 3544150M71M 45 27.6 1.60% E01 3545030M61M 75 27.6 1.60% E03 3545030M61M 112.5 27.6 1.80% E03 3545030M61M 150 27.6 2.00% E06 3545030M61M 225 27.6 3.00% E06 3545030M61M 300 27.6 3.50% E10 3545050M61M 500 27.6 4.00% E18 3545080M71M 750 27.6 5.75% E25 3545080M71M 1000 27.6 5.75% E30 3545100M71M 1500 27.6 5.75% E50 3545150M71M 100 30.0 1.80% E03 3545030M61M 160 30.0 2.00% E06 3545030M61M 200 30.0 2.00% E06 3545040M61M 250 30.0 3.00% E10 3545040M61M 400 30.0 4.00% E12 3545050M61M 500 30.0 4.00% E18 3545080M71M 630 30.0 4.00% E18 3545080M71M 800 30.0 5.75% E25 3545080M71M 1000 30.0 5.75% E30 3545100M71M 1250 30.0 5.75% E40 3545125M71M 1600 30.0 5.75% E50 3545150M71M 100 33.0 1.80% E03 3545030M61M 160 33.0 2.00% E06 3545030M61M 200 33.0 2.00% E06 3545030M61M 250 33.0 3.00% E10 3545030M61M 400 33.0 4.00% E12 3545050M61M 500 33.0 4.00% E18 3545080M71M 630 33.0 4.00% E18 3545080M71M 800 33.0 5.75% E25 3545080M71M 1000 33.0 5.75% E30 3545080M71M 1250 33.0 5.75% E40 3545100M71M 1600 33.0 5.75% E40 3545100M71M 2000 33.0 5.75% E50 3545125M71M 45 34.5 1.60% E01 3545030M61M 75 34.5 1.60% E03 3545030M61M 112.5 34.5 1.80% E03 3545030M61M 150 34.5 2.00% E06 3545030M61M 225 34.5 3.00% E06 3545030M61M 300 34.5 3.50% E10 3545030M61M 500 34.5 4.00% E12 3545050M61M 750 34.5 5.75% E18 3545080M71M 1000 34.5 5.75% E25 3545080M71M 1500 34.5 5.75% E40 3545100M71M 2000 34.5 5.75% E50 3545125M71M Notes: Line-to-neutral rated fuses can be used on Gnd Y- Gnd Y transformers with less than 50% delta loading MagneX recommendations based on Minimum trip curves, and Maximum trip and clear curves, R240-91-310. Deration factor of 0.5% per degree C above ambient (25 C). Allowable loading greater than 140% for four hours in accordance with ANSI /IEEE C57.91.1981 Guide for Loading Distribution Transformers, Table 6. MagneX/ELSP coordinations based on coordination requirements of single-phase sense, single-phase trip version of the MagneX interrupter. Proper coordination requires WYE connected transformer primary. Backup current limiting fuses may be rated for line-toneutral voltage for Gnd Y - Gnd Y connections, with less than 50% delta loading ONLY. If this guideline is not followed, recovery voltages exceeding the backup current-limiting fuse may cause fuse failure. In all other cases, voltage rating of the backup current-limiting fuse must be line-to-line rated. Note: The MagneX recommendations above 22 kv are for Gnd.Y Gnd. Y transformers with less than 50% delta loading ONLY. TABLE 6 Isolation Link MagneX Correlation Chart Sensor Number Isolation Link E01 3637803B01 E03 3637803B08 E06 3637803B02 E10 3637803B09 E12 3637803B10 E18 3637803B03 E25 3637803B03 E30 3637803B05 E40 3637803B05 E50 3637803B05 TABLE 5 Two-Phase MagneX Recommendations Primary Voltage kv kva/kv 2.4 4.16 4.8 6.9 7.2 7.62-7.97 8.32 12.00 12.47-13.2 13.8-14.4 19.92 10 E06 E06 E03 E03 E03 E03 E03 E01 E01 E01 E01 15 E10 E06 E06 E03 E03 E03 E03 E03 E03 E03 E01 25 E18 E10 E10 E06 E06 E06 E06 E03 E03 E03 E03 37.5 E25 E18 E12 E10 E10 E10 E10 E06 E06 E06 E03 50 E30 E18 E18 E12 E12 E12 E10 E06 E06 E06 E06 75 E50 E30 E25 E18 E18 E18 E18 E10 E10 E10 E06 100 - E40 E30 E25 E25 E25 E18 E12 E12 E12 E10 167 - - E50 E40 E40 E30 E30 E18 E18 E18 E12 Note: Recommendations are based on: Minimum trip curves, and Maximum trip and clear curves, R240-91-310. Deration factor of 0.5% per C above 25 C. Allowable loading greater than 140% for four hours in accordance with ANSI/IEEE C57.91.1981 Guide for Loading Distribution Transformers, Table 6. 7

Two- & Three-Phase MagneX Interrupter TABLE 7 MagneX Significant Digit Catalog Number System Example: To order a three-phase MagneX Interrupter with single-phase sense, three-phase trip, with float and E12 sensor, the catalog number would be MX3BN1MDE12 Standard Options Digits: 1 2 3 4 5 6 7 8 9 10 11 M X 3 B N 1 M D E 1 2 Product MagneX Phases 2-Two 3-Three Indicator B-w/o Indicator Overload N-Non EO Trip Type M-Multi-Phase Trip (M for 2-Phase) Float 1-w/Float 2-w/o Float System Connection D-Delta (2-Phase) Y-Wye Sensor Size E01 E03 E06 E10 E12 E18 E25 E30 E40 E50 TABLE 8 Hardware Kit Description Standard Handle Kit & Hardware, w/o Emergency Overload Standard Handle Kit & Hardware, with Emergency Overload Catalog Number 3638535A04 3638535A05 Two- and three-phase MagneX is not yet available with emergency overload feature. TABLE 9 Recommended Two-Phase MagneX Interrupter and ELSP Current-Limiting Fuse Combinations Nominal 8.3 kv 15.5 kv 23 kv Single Phase (kv 2.4 4.16 4.8 6.9 7.2 7.62-8.32 12.0-12.47 13.8-19.92 Phase-to-ground) 7.97 13.2 14.4 10 kva ELSP Rating 40 40 30 30 30 30 30 30 30 30 30 MagneX Element E06 E06 E03 E03 E03 E03 E03 E01 E01 E01 E01 15 kva. ELSP Rating 50 40 40 30 30 30 30 30 30 30 30 MagneX Element E10 E06 E06 E03 E03 E03 E03 E03 E03 E03 E01 25 kva ELSP Rating 100 50 50 40 40 40 40 30 30 30 30 MagneX Element E18 E10 E10 E06 E06 E06 E06 E03 E03 E03 E03 37.5 kva ELSP Rating 125 100 65 50 50 50 50 40 40 40 30 MagneX Element E25 E18 E12 E10 E10 E10 E10 E06 E06 E06 E03 50 kva ELSP Rating 150 100 100 65 65 65 50 40 40 40 40 MagneX Element E30 E18 E18 E12 E12 E12 E10 E06 E06 E06 E06 75 kva ELSP Rating 165 150 125 100 100 100 100 50 50 50 40 MagneX Element E50 E30 E25 E18 E18 E18 E18 E10 E10 E10 E06 100 kva ELSP Rating 150 150 125 125 125 100 65 65 65 50 MagneX Element E40 E30 E25 E25 E25 E18 E12 E12 E12 E10 167 kva ELSP Rating 165 150 150 150 150 100 100 100 65 MagneX Element E50 E40 E40 E30 E30 E18 E18 E18 E12 Note: Table shows minimum recommended ELSP Fuse ratings. Recommended ELSP Backup Fuse (described in Catalog Section 240-50) will coordinate with the MagneX Interrupter and melt on internal transformer faults. The MagneX Interrupter recommendations are based on: Minimum trip curves, and Maximum trip and clear curves R240-91-310. Deration factor of 0.5% per C above 25 C. Allowable loading greater than 140% for four hours in accordance with ANSI/IEEE C57.91-1981 guide for Loading Distribution Transformers, Table 6. 30, 40, 50 and 65 A ELSP Fuses are the Mini Configuration (I.E. 354 M61M Series). All coordinations are based on latest vintage ELSP designs. Catalog numbers for fuses larger than 65 A have M71M suffix, 3543 _M71M for 8.3 kv fuses, 3544 _M71M for 15.5 kv fuses and 3545 _M71M for 23.0 kv fuses. 2004 Cooper Industries, Inc. MagneX Interrupter is a registered trademark of Cooper Industries, Inc. Viton is a registered trademark of E.I. DuPont Demours & Company. 8 1045 Hickory Street Pewaukee, WI 53072 USA www.cooperpower.com MI 6/04