HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

Similar documents
Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

COM Overcurrent Relay

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

Magnetic Overload Relays

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

GEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K. GE Protection and Control 205 Great Valley Parkway Malvern, PA

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

INSTRUCTIONS. GEI-38974A Supersedes GEI INSTANTANEOUS CURRENT RELAY TYPE PJC2OA GENERALS ELECTRIC

INSTRUCT IONS GEH-1 793J INSTANTANEOUS AUXILIARY RELAY TYPES HGA11A, C, H, J, K, P, S, T, V, W, X GENERAL ELECTRIC AUILIARV P A GENERALS ELECTRIC

C. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

TABLE I 60 CYCLE BURDEN OF THE CVD RELAY AT CONTINUOUS RATING

INSTRUCTIONS GEI-98305C UNDERVOLTAGE RELAY D-C. Type NGV18A GENERAL ELECTRIC

Installation Sheet January, 2016 Supersedes February, 2013

CX-Series. Circuit Breaker

DETAIL SPECIFICATION SHEET

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

Model HEA Multicontact Auxiliary

GENERAL ELECTRIC INSTRUCTIONS GEK- 2M42. Insert Rooklet GEH 1793 INSTANTANEOUS AUXILIARY RELAY TYPE HGA MODEL 12HGAI1E(-)A I NTRODUCT ION

4.0 OPERATION Type ITH-T Relay

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

A. Submit manufacturer's literature and technical data before starting work.

F-Series. Circuit Breaker

Horizontal Circuit Switchers

Horizontal Circuit Switchers

F-Series. Circuit Breaker

AF series contactors (9 2650)

34 th Hands-On Relay School

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

B CW POWER RELAY

Critical Power Switchboards. Selection and Application Guide

Crane Control Class 9055

INTERPLANT STANDARD - STEEL INDUSTRY

INSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS

IN2 Enclosed Switches and Circuit Breakers

Installation Sheet January, 2016 Supersedes June 2013

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

SURE-TRIP OEM RELACEMENT TRIP UNIT

AF series contactors (9 2650)

Circuit breaker interlocking and operation requirements SIEMENS

Technical Information

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

Type SOQ Negative Sequence Time Overcurrent Relay

6R MATRIX. Modular Relays. rms. Auxiliary, Trip & Supervision Relays

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

SURE TRIP RETRO KITS

MERCURY CONTACTORS & RELAYS

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

P. Sub 4 184A404. Sub 3 876A220

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

INSTRUCTIONS SYNCHRONISM-CHECK RELAYS. GE Meter and Control. 205 Great Valley Parkway Malvern, PA Types IJS51A.

INSTRUCT ION S GEK A. Supersedes GEK TIME OVERCURRENT RELAY TYPE IAC66S GENERAL ELECTRIC

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

www. ElectricalPartManuals. com Type CO Overcurrent Relays E ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA

~ SERVICE SPECIFICATION SU-4522-A ~

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SECTION MOTOR CONTROLLERS

(Example) In case of DC24 to 48V, it is operating time for DC24V.

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

41-747G. Figure 1: Type DGF Relay without case (Photo)

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

INSTRUCTIONS GEI-10190L DC AUXILIARY RELAYS TYPE HGA17A TO F, H, M, R, S, T GENERAL ELECTRIC

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

AC Contactors. Type IC5181. Ward Leonard Electric Company Inc. 401 Watertown Road Thomaston, CT USA Tel:

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

The galvanic separation of the primary or actuating circuit and the load circuits

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

SECTION MOTOR CONTROLLERS

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

Auxiliary Relay. Type RXP8n, RXPQ8n

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Auxiliary Relay. Type P8n, PQ8n, PN8n

Most home and business appliances operate on single-phase AC power. For this reason, singlephase AC motors are in widespread use.

CR193 Vacuum Limitamp* Contactors

MCCB Accessories to suit AF

GEK 45484B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAY HFA151 TYPE. GE Protection and Control 205 Great Valley Parkway Malvern, PA

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

Cat. RK 47-2 E CASE AND MOUNTING. January 1967 DESIGN AND MODE OF OPERATION

Transcription:

HA Hinged Armature Auxiliary Hinged armature auxiliary relay to perform auxiliary functions in and circuits. eatures and Benefits Molded case with 4 mounting options Drawout case available Applications multiplication Protection and Control Standard, low and variable time pickup available undervoltage (low dropout) E Multilin

Applications The HA hinged armature auxiliary relays are designed to provide additional contacts, higher contact carrying and interrupting ratings, timing, interlocking, electrical separation, or other auxiliary functions. Where more than two circuits are to be controlled, the coils of two or more relays may be connected either in parallel on or in series or parallel on to obtain the desired results. eneral-purpose Relays Standard : The HA is the standard auxiliary relay which is instantaneous in operation and is used for auxiliary functions where intentional delays of over -/4 to cycles are not required and where standard pickup values, as listed in the table, are satisfactory. The contact arrangement for each relay (or unit) is doublepole, double-throw ( normally open, normally closed). Low Pick-up: The HA4 relay has been designed with a shorter armature gap which is obtained by the setting of an adjustable back contact. This construction allows a lower pickup value than normal and a faster pickup time. Also, relays are available for tripping duty and target operation with pickup times of / cycle on a 0-cycle basis, and are intermittently rated. The contact arrangement is one single-pole, double-throw contact and one normally open contact for each relay (or unit). The second normally closed contact is not used with the low pickup setting. This second contact can be used if the wipe is restored to normal and the control spring tension increased thus raising the pickup toward the 80 percent (0 percent cold) level which would apply with standard gap relays. Undervoltage Low Dropout. The HA4BH(-)A relay is a three-phase residual voltage relay with low dropout. A primary application is as on automatic throwover schemes where induction motors are the principal load. Time-Delay Relays ixed-time Dropout. The HA is designed to provide a timedelay dropout of approximately cycles (0-cycle basis). The delay is obtained by momentarily sustaining the magnetic flux at the relay pole face by means of induced currents in a copper ring which acts as a shorted one-turn coil. A small delay in pickup time is also obtained since the induced currents also tend to retard the buildup of the relay magnetic field. Operating times are measured at or from rated voltage or amperes for pickup and dropout times respectively. Adjustable-time : The HA4D has a resistor-capacitor timing circuit with the resistor being adjustable to vary the charging time of the capacitor which is connected across the relay operating coil. arrangement for the fixed-time dropout (HA) is one single-pole, double-throw contact and one normally open contact per relay (or unit). Relay Characteristics Voltage or Current Values. The values listed in the table below apply as indicated for all relays. Ratings Standard Relays - HA The current-closing rating of the contacts is 0 A. The currentcarrying rating is A continuously or 0 A for one minute. Interrupting Ratings of s in Amperes -circuit Single V V Break NONINDUCTIVE CIRCUITS - 8 0. 0 0 INDUCTIVE CIRCUITS - 0. Double Break 0 0.4 0 0. 0. 0 Low Relays HA4, HA The current closing ratings of the contacts is 0 A. The current carrying rating is A continuously or 0 A for one minute. The interrupting ratings (noninductive circuits) for the various voltages are as follows: -circuit V V NONINDUCTIVE CIRCUITS - INDUCTIVE CIRCUITS - Single Break 0. 0. 0 0. 0. www.eindustrial.com/multilin

Relay Percentage of Rated V or A Classification Value Dropout Value HA Standard 80% 80% -0% -% HA4 Low % 0% 0-0% -% HAA,B,C Time 0-% 0-0% -% -% HAD,H Time 80% Max. 0% Max. -% -% BC surface mounting with cover BC semi-flush mounting with cover C surface mounting with cover C surface mounting with cover with provisions for front mounting HA Order Code Breakdown Standard HA * ** * A J S Surface mounted front connected with solid cover Surface mounted front connected with solid cover and provision for front mounted Electrical data (see column under Selection guide) 4 8 0 0 4. 4 0 0 Hz 0 Hz N.O. N.C Res. @ C 00 0 80 0 00 Res. 00 0 80. Wt. in lbs (kg) (0.) (.4) Order Code Breakdown HA *** **** B 4B4 J Standard pickup general purpose double unit Standard pickup general purpose single unit Low pickup general purpose single unit Low pickup general purpose double unit Single short gap unit with rectifiers (0 cycles, low burden) Low pickup time delay single unit, fixed time ( cycles min. dropout) (copper slugged coil) Electrical data (see column under Selection guide) www.eindustrial.com/multilin

Drawout Case Relays Option B B B B B B B B B B J A A A 4A A A 8A 4A 80A 4A A A A A 4A A A A A A A A A A A 4A A A A A A A A A A A 4A A A 8A 4A 80A 4A A A A 4A A A A A 4. 4, 4. 0 4. 4. V 0 Hz V 0 Hz @ C 0 80 0 0 0 80 0 0 0 80 0 0 00 0 80 0 0 8 8 80 00 Each Unit Z 0 0 0 0 ➀ ➀ Time Case S S S S S. Wt. in lbs (kg) (.) (.) () () () ➀HA (standard pickup) double pole, double throw { normally open/two normally closed} per unit. HA4 (low pickup) one single pole, double throw. HA (time delay) plus one normally open contact per unit. 4 www.eindustrial.com/multilin

HA4 order Code Breakdown Adjustable Time Delay on HA4 * * D X Back connected with cover Electrical data (see column under Selection guide) 4 Volts or Less - 0 - - 0-0 - 0 N.O. N.C -4 - - - - - 4-4. Wt. in lbs (kg) 8 (.) (.4) HA4 order Code Breakdown Molded Case Tripping Relays, / Cycle or Less (for tripping two breakers) HA4 ** ** AM AL Back connected with cover ront connected with cover Electrical data (see column under Selection guide) 4 8 4 8 0 8 4 4 4 4 4 Volts 80% or Less N.O. N.C or A AM or A or 0. A AM or 0. A or Carrier CX or CY AL. Wt. in lbs (kg) (0.) (.4) www.eindustrial.com/multilin

HA4 Order Code Breakdown Low (% of rating for or 0% of rating for ) HA4 * ** * A A Surface mounted front connected with solid cover Electrical data (see column under Selection guide) 4 8 0 0 4. 4 0 0 Hz 0 Hz N.O. N.C Res. @ C 00 0 80 0 00 Res. 00 0 80. Wt. in lbs (kg) (0.) (.4) HA Order Code Breakdown Time Delay, ixed Time ( cycles dropout) (copper slugged coil) HA * ** * A C H ront connected with solid cover (NO STUDS) Electrical data (see column under Selection guide) 4 8 0 4. 4 0 0/0 Hz N.O. N.C Res. @ C 00 80 8 8 4. 00 Res.. Wt. in lbs (kg) (0.) (.4) www.eindustrial.com/multilin

HA order Code breakdown ixed Time with. -cycle Delay on Dropout HA * ** * D H ront connected with solid cover (NO STUDS) Electrical data (see column under Selection guide) 4 8 0 4. 4 0 0/0 Hz N.O. N.C. Volts 0% 80% Res. @ C 00 80 8 8 4. 00 Res.. Wt. in lbs (kg) (0.) (.4) Order online save time www.eindustrial.com/pm www.eindustrial.com/multilin