J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Similar documents
L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

K: bracket type. L: pole type

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6402/2

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear fluorescent luminaire LED V-CG-S

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

7 Lighting Technology

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-Steel Light Fittings Series 6114/1

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Emergency Luminaire with LED Series EXLUX 6409/1

LED Linear Luminaire Series EXLUX 6402

Plug and Socket Devices SolConeX 16 A Series 8570

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Load disconnect switch Series 8146/5-V11

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

7 Lighting Technology

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Sheet-Steel Light Fittings Series 6014 / 6414

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Linear fittings EVDL LED fitting - zones 21, & 22

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Floodlight Series 6121

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

7 Lighting Technology

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Terminal Boxes Series 8125

Floodlight LED Series 6125

EXEL-L. Detail of the internal side. Transparent polycarbonate

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Linear fittings EVNL LED fitting - zones 2, & 22

Floodlight LED Series 6525

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Easy and safe installation

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Floodlight LED Series 6525

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

EX-REPAIR AND MAINTENANCE RECEPTACLES

Position Switches Series 8060/2

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Compact Sheet-Steel Light Fittings Series 6114

10 Load and Motor Switchgear

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Position Switches Series 8074/2

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Position Switches Series 8070/2

Linear Luminaire for Fluorescent Lamps

Tubular Light Fitting with LED Series 6036

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Sheet Steel Emergency Light Fitting Series 6018

Control Buttons / Switches for Panel Mounting Series 8003

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

7 Lighting Technology

Linear fittings EVN Fluorescent fitting - zones 2 & 22

I Ex-Safety switches I

Safety Switches Series 8537

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

Battery Boxes Series 8316

I Ex-safety switches I

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

EWE. Ex de. Cooling fins

Operating Instructions

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Terminal Boxes Series 8125

Zone 1 Linear Range - Installation Guide

11 Control Panels, Distribution Panels and Components

7 Lighting Technology

Tank Inspection Lights Series 6122

Control switch/load disconnect switch Series 8008

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

HTSB system System overview

Transcription:

Lighting Technology Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone Zone 1 and Zone Class I, Zone 1 and Zone Class I, Division, Groups A, B, C, D Two enclosure types: 18W, 36W. Enclosure in glass fibre reinforced polyester, diffuser in polycarbonate, corrosion-proof. Ex e enclosure with explosion-proof components inside. Safety interlock between enclosure and diffuser switches off on opening. Electronic ballast, power factor.9. Emergency unit with protections against over charge and over discharge. End of lamp life (EOL) rectification effect protection. Catalogue number logic BAY1-Q x J: Emergency lighting (optional) L: pole type X: ceiling type Mounting B: wall type D: pendant chain type G: pendant pole type Lamp number Lamp power (W) Explosion-proof light fittings for fluorescent lamp Zones 1&; 1& / General Catalogue 1.1.13

Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Technical data Explosion-proof light fittings for fluorescent lamp BAY1-Q x Explosion protection Gas explosion protection Dust explosion protection Certificates Conformity to standards Material Enclosure Diffuser Ballast Exposed fastener Interlock Lamp Lamp brand Lamp power (W) II G Ex deq IIC T4 Gb II D Ex t IIIC T8 Db IP66 LCIE 1 ATEX 34X; IECEx CQM 7.7 BR977 (Brazil); S-XPL/447 (South Africa); FM (USA); GOST.R (Russia) EN 679-:9, EN 679-1:7, EN 679-:7, EN 679-7:7 EN 679-31:9 IEC 679-:7, IEC 679-1:7, IEC 679-:7, IEC 679-7:6 IEC 679-31:8 GRP, stands 7J impact, corrosion-proof Polycarbonate, 9% light transmission, stands 7J impact Explosion-proof electronic ballast, power factor.9, with protection against short circuit, overload, lamp aging, lamp damage and dissymmetry power of lamp tube. Certificate No.: LCIE 6 ATEX 3U; IECEx CQM 7.U; BR976-U (Brazil). Stainless steel BZX-6 explosion-proof distance switch, switching off on opening. Certificate No.: LCIE 6 ATEX U, IECEx CQM 7.6U PHILIPS T8 (supplied with the light fittings) 36W x 18W x 36W x 1 18W x 1 Rated voltage Protection class Degree of protection Ambient temperature Terminal Cable entries Available cable outer diameter 96~4V AC /6Hz II (Protection against electric shock) IP66 - ~+ 3 x 1.~4mm (L+N+PE) 4 x Φ6: x M x 1. cable gland (DQM-I Ex e, plastic), x M x 1. plug. Φ9~Φ16 (mm) Selection table Type/Ordering code Lamp power(w) Weight(kg) Type/Ordering code Lamp power(w) Weight(kg) BAY1-QL 11.4 BAY1-Q36 x L 36 x 11.6 BAY1-QX 11.3 BAY1-Q36 x X 36 x 11.4 BAY1-QB 1.3 BAY1-Q36 x B 36 x 1. BAY1-QD 1.6 BAY1-Q36 x D 36 x 1.7 BAY1-QG 1. BAY1-Q36 x G 36 x 1.4 BAY1-QL 6.8 BAY1-Q18 x L 18 x 7. BAY1-QX 6.7 BAY1-Q18 x X 18 x 6.9 BAY1-QB 7.8 BAY1-Q18 x B 18 x 7.9 BAY1-QD 8.1 BAY1-Q18 x D 18 x 8. BAY1-QG 7.7 BAY1-Q18 x G 18 x 7.8 Note: Products above include all the mounting accessories listed in Mounting Accessories & Spare Parts Table (see P/6~7). General Catalogue 1.1.13 /3

Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Technical data Explosion-proof emergency light fittings for fluorescent lamp BAY1-Q x J Explosion protection Gas explosion protection Dust explosion protection Certificates Conformity to standards Material Enclosure Diffuser Emergency unit Emergency controller Exposed fastener Lamp Lamp brand Lamp power(w) Emergency power(w) Emergency start time Charge time Emergency lighting time Rated voltage Protection class Degree of protection Ambient temperature Terminal Cable entries Available cable outer diameter II G Ex deq IIC T4 Gb II D Ex tb IIIC T8 Db IP66 LCIE 1 ATEX 39; IECEx CQM 1.X; BVC 1.3 (Brazil); FM (USA) GOST.R (Russia) EN 679-: 9, EN 679-1: 7, EN 679-: 7, EN 679-7: 7 EN 679-31: 9 IEC 679-: 11, IEC 679-1: 7, IEC 679-: 7, IEC 679-7: 6 IEC 679-31: 8 GRP, stands 7J impact, corrosion-proof Polycarbonate, 9% light transmission, stands 7J impact Special emergency controller and NI-MH battery pile, with protection against over charge and over discharge BY- explosion-proof emergency controller. Certificate No.: LCIE 1 ATEX 31U, IECEx CQM 11.41U Stainless steel PHILIPS T8 (supplied with the light fittings) 36W x 36W x 1 36W x 1, 18W x 1.3s 4h 1min (18min is optional) 96~4V AC /6Hz II (Protection against electric shock) IP66 - ~+ 3 x 1.~4mm (L+N+PE) 4 x Φ6: x M x 1. cable gland (DQM-I Ex e, plastic), x M x 1. plug. Φ9~Φ16 (mm) 18W x 18W x 1 Selection table Type/Ordering code Lamp power(w) Weight(kg) Type/Ordering code Lamp power(w) Weight(kg) BAY1-QLJ 13. BAY1-Q36 x LJ 36 x 13. BAY1-QXJ 1.9 BAY1-Q36 x XJ 36 x 13.1 BAY1-QBJ 14. BAY1-Q36 x BJ 36 x 14.1 BAY1-QDJ 14.3 BAY1-Q36 x DJ 36 x 14.4 BAY1-QGJ 13.9 BAY1-Q36 x GJ 36 x 14. BAY1-QLJ 8.6 BAY1-Q18 x LJ 18 x 8.8 BAY1-QXJ 8. BAY1-Q18 x XJ 18 x 8.7 BAY1-QBJ 9.6 BAY1-Q18 x BJ 18 x 9.7 BAY1-QDJ 9.9 BAY1-Q18 x DJ 18 x 1. BAY1-QGJ 9. BAY1-Q18 x GJ 18 x 9.6 Note: Products above include all the mounting accessories listed in Mounting Accessories & Spare Parts Table (see P/6~7). /4 General Catalogue 1.1.13

Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Photometric data 18W x photometric data Rated luminous flux:1lm; The data from PHILIPS lamp; Luminous intensity distribution cd/1lm 36W x photometric data Rated luminous flux:lm; The data from PHILIPS lamp; Luminous intensity distribution cd/1lm 4 8 1 16 3 9 6 1 1 3 3 4 4 349 348 34 33 34 39 9 7 48 6 6 7 7 8 8 9 193 16 13 98 66 38 18 4 8 1 16 3 9 6 1 1 3 3 4 4 783 78 779 776 77 77 777 776 77 76 6 6 7 7 8 8 9 78 731 7 66 61 36 18W x 1 fluorescent lamp*. 36W x 1 fluorescent lamp*. We can provide lighting design and data by professional lighting software DIALUX based upon simulated site situation on request. Schematic diagram (BAY1-Q x J) 1 1 Note: Tube for lamp shall be default for single tube fittings. Dimension drawings (all dimensions in mm) - subject to alteration BAY1-Q36 x BAY1-Q18 x General Catalogue 1.1.13 /

Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Mounting type (all dimensions in mm) - subject to alteration Installation reference D: pendant chain type G: pendant pole type 6-Φ1. -Φ84 4-Φ1 1 3 4 L: pole type (the pole is provided by user) Φ4 7 8 Φ4 7 6 Φ4 7 6 Φ48 4-Φ14 Φ48 Φ48 Suitable for ground pole type Suitable for fence pole type Suitable for wall pole type X: ceiling type B: wall type 4-Φ1 9 1 4-Φ11 Mounting accessories and spare parts table Supplied according to the mounting type Mounting Accessories Ordering Weight type Name Qty Illustration code (kg) 3-Φ1. 1.Sucker 13617.1 D: pendant chain type Φ84.Chain Length: 4mm 13616.8.Mounting bracket Same as pendant pole type 1363.7 3.Mounting bracket Φ8. 1S1G1.4 -Φ1 G: pendant pole type 4.M8 Screw Length: 3mm 1S1G.1.Mounting bracket Φ9 1363.7 -Φ1 Note: Accessories not in the table shall be supplied by user. /6 General Catalogue 1.1.13

Light Fittings for Fluorescent Lamp BAY1-Q Series Explosion-proof Light Fittings for Fluorescent Lamp Mounting accessories and spare parts table Supplied according to the mounting type Mounting Accessories type Name Qty Illustration Ordering code Weight (kg) 6.Mounting bracket 1361.4 -Φ7 L: pole type 7.G1 1/4 Pipe clamp 13614.4.Mounting bracket Same as pendant pole type 1363.7 X: ceiling type 9.Mounting bracket 1361. B: wall type 1.Wall bracket Welded sheet steel 136B.6 Note: Accessories not in the table shall be supplied by user. Accessories Picture Name Ordering code Weight (kg) Explosion-proof distance switch 1363.4 Spanner 1364. Lamp holder (with wires) 136. 36W Explosion-proof electronic ballast 13611 1.3 18W Explosion-proof electronic ballast 1184 1.3 36W Explosion-proof emergency controller (with battery) 13619 1.7 18W Explosion-proof emergency controller (with battery) 118 1.7 General Catalogue 1.1.13 /7