Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Similar documents
Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Miniature I/P, E/P Transducer

Electropneumatic Transducer (I/P, E/P)

Table of Contents. Proportional & Precision Regulator Instrumentation

Precision Regulators.

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Numatics 2003 Rev. 11/03 PDFPRECISION-1

Features and Benefits

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

Type Type 1001 Transducers. I/P & E/P Transducers

Type Type I/P & E/P Transducers

Type I/P & E/P Transducers

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

Fisher i2p 100 Electro Pneumatic Transducer

Fisher 3660 and 3661 Positioners

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

Precision Control Devices

V200 Series Positioners

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Data Sheet. I/P and E/P converters. RS stock numbers ,

Features. Flexibility

Valve Positioners Series 760P/E Valve Positioners

Fisher 546 Electro Pneumatic Transducer

Valve Positioners Series 760P/E Valve Positioners

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09


The Series I/P Current to Pressure Transducer

Transducers. Type Type 1000EX. Type 1000HR. Type 1000 Hazardous Use. Type Type 1001 Nema 3R. Type 1001 Nema 4X.

Corrosion Resistant Pneumatic Positioners Model 4700P and 4700E

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

The friction free alternative

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

Fisher 3660 and 3661 Positioners

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

ELECTRONIC CONTROLLER

The Widest Range of Products for Diverse Market Applications

When you need pneumatic control of force, motion and displacement to deliver unparalleled accuracy and resolution:

Type 3660 and 3661 Positioners

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter

POSITIONERS and Controls for Complete Valve Automation

TECHNICAL BULLETIN. Logix 520MD Series Digital Positioner. Experience In Motion FCD LGENTB /09

Ar-Mite TM Low Flow Armored Flowmeter

PI-Air WV-121. PI-Air type WV-121 Pneumatic cylinder actuator with positioner

ITT Conoflow Process Control Solutions

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

Masoneilan. Model 8007 and 8008 Electropneumatic Transducers. New Nozzle Design Minimises Effect of Vibration. Specification Data BS 6500 E 06/03

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

WARNING! READ BEFORE INSTALLATION

m WARNING! READ m BEFORE INSTALLATION

Series Level-Trol Electronic Liquid Level Transmitters

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter

THE INSIDE STORY OF THE QPV OR MPV:

Fisher 3660 and 3661 Positioners

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Fisher 646 Electro Pneumatic Transducer

Type 2000 Transducer Product Instructions

ABB Automation. Characterizable Pneumatic Positioners Series AV1/2/3/4. Series AV1/2/3/4 Pneumatic Positioners

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Fisher 646 Electro Pneumatic Transducer

PSC-B. Pressure sensing and control. Herion 18D Pneumatic pressure switches (diaphragm type), - PSC-2

Precision Pneumatic and Electropneumatic Controls

SKINNER Intrinsically Safe Series Four-Way

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Actuators & Positioners Characterizable Pneumatic Positioners Series AV1/2/3

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /13

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

ABB MEASUREMENT & ANALYTICS DATA SHEET. AV1 and AV2 Characterizable pneumatic and electro-pneumatic positioners

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Series 3730 Electropneumatic Positioner Type

PIT, PIF & PIX. Features. Pressure-to-Current Transmitters

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

FasTrak High Capacity Smart Positioner

Fisher 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter

Fisher i2p-100 Electro Pneumatic Transducer

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

V200 Series Positioners

PIT, PIF & PIX Pressure-to-Current Transmitters

2 Manifold and Rack Kit

TZIM. Electropneumatic Analog Positioner 10/ EN

Electro-pneumatic Transducers Pressure Regulators Pneumatic Relays Volume Boosters Accessories Product Overview

Fisher 846 Current-to-Pressure Transducers

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Type 646 Electro-Pneumatic Transducers

Series AV1 / 2 / 3 / 4 Characterizable pneumatic positioners

Fisher FIELDVUE DVC6000 Digital Valve

Transcription:

Type 900X Miniature I/P, E/P Transducer for Electronic Air Pressure Control Self-correcting to maintain precise control Available with zero-based ranges The Type-900X I/P, E/P transducer converts an electrical signal (current or voltage) to a proportional pneumatic output. Utilizing closed-loop pressure feedback circuitry, it provides precise, stable pressure outputs to final control elements. Immunity to vibration effects or mounting position, high tolerance to impure air, and low air consumption make this unit ideal for demanding applications. The compact housing, accessible ports and easy adjust-ments make it perfect for constrained spaces. An integral volume booster provides high flow capacity, increasing control speed in critical applications. Features Electronic Closed-loop Feedback Minimizes effects of vibration, mounting position, temperature and supply pressure Compact Size Great for high density mounting Easy Wiring Conduit, terminal block, M12 or DIN 43650 connections Input/Output Ports on Front and Back Provides flexible pneumatic connections Other Features Field selectable outputs (optional), field reversible, RFI/EMI protection, external orifice, supply pressures up to 130 psig Intrinsic Safety Approvals Standard feature for 4-20mA units: Factory Mutual (FM), Canadian Standards Assoc. (CSA) Optional feature for 4-20mA units: ATEX

Type 900X Durable, precise control from a variable signal Functional Specifications Standard Range High Output Range Inputs 4-20 ma, 0-10VDC, 1-9 VDC, 0-5 VDC, 1-5 VDC Outputs psig 1-17 3-15 3-27 6-30 0-15 0-30 2-60 2-100 0-60* (BAR) (0.07-1.20) (0.20-1.00) (0.20-1.80) (0.40-2.00) (0.00-1.00) (0.00-2.00) (0.14-4.00) (0.14-6.90) (0.00-4.00) Supply Pressure psig 22-60 20-100 32-100 35-100 25-65 40-70 65-130 105-130 70-80 (BAR) (1.50-4.0) (1.40-6.90) (2.20-6.90) (2.40-6.90) (1.72-4.50) (2.75-4.82) (4.50-9.00) (7.20-9.00) (4.82-5.50) Air Consumption* 1.5 scfh (0.75 Nl/min) at 4.5 scfh (2.25 Nl/min) at mid range typical mid range typical Flow Capacity 4.5 scfm (127 Nl/min) at 20.0 scfm (566 Nl/min) at 25 psig (1.7 BAR) supply 130 psig (9.0 BAR) supply 12.0 scfm (340 Nl/min) at 100 psig (7.0 BAR) supply Temperature Limits Operating -40 to +158 F (-40 to +70 C) Storage -40 to +200 F (-40 to +93 C) Loop Load, I/P Transducer 9.5 VDC @ 20 ma Supply Voltage, 7-30 VDC, less than 3 ma E/P Transducer Signal Impedance 10 Kilohms E/P Transducer Extended periods of electrical input without supply air pressure may damage unit. *Zero-based units have slightly higher air consumption. Principles of Operation The heart of this unique technology is a bimorph piezo actuator that is encapsulated in a protective skin. This provides a constant defense against humidity and contaminants often found in process operating environments. The Type-900X utilizes a nozzle to control a pilot pressure to an integral volume booster. The resultant output pressure is measured by a pressure sensor which in turn provides a feedback signal to the circuitry. The feedback circuit compares this signal to the input signal and self corrects as necessary, thus minimizing the effects of variation in vibration, position, temperature, and supply pressure. The current/voltage signal flows to the piezo actuator causing the actuator to move toward a nozzle. This restricts the flow of air through the nozzle and creates back pressure in the nozzle which acts as a pilot pressure to an integral booster relay. Performance Specifications Accuracy, Hysteresis, and Repeatability Deadband Position Effect Vibration Effect Supply Pressure Effect Temperature Effect Reverse Polarity Effect RFI/EMI Effect ±0.10% of span guaranteed.02% of span No measurable effect Less than ±1.0% of span under the following conditions: 5-15Hz @ 0.8 inches constant displacement; 15-500Hz @ 10g s No measurable effect ±0.045%/ F (0.07%/ C) of span No damage from reversal of normal supply current (4-20 ma) or from misapplication of up to 60 ma Less than.5% of span change in output pressure per En 61000-4-3:1998, Amendment 1, Performance Criterion A Pressure Sensor Start-up Spring Diaphragm Assembly Supply Valve Potentiometer Piezo-electric Actuator Nozzle Relief Valve

High accuracy ±0.10% of span NEMA-4X (IP65) enclosure Intrinsic safety approvals Optional field selectable outputs Field reversible Split range operation Conduit, terminal block, M12 or DIN connector options Wall, panel, pipe or DIN rail mounting Vibration and position insensitive Low air consumption for greater operating economy Reliable in harsh environments Compact size Built-in volume booster Supply pressure up to 130 psig Input/output ports on front and back Applications The Type 900X is used extensively by professionals who demand maximum performance and reliability when controlling valve actuators, pneumatic valve positioners, air cylinders, clutches, brakes, dampers, louvres, and pumps. Original equipment applications include: Machinery for grinding or polishing Automated assembly, conveying, dispensing and web tensioning Semiconductor manufacturers Food processing HVAC, welding, leak testing and painting Physical Specifications Port Sizes Pneumatic 1/4" NPT Electric 1/2" NPT Media Clean, dry, oil-free, air-filtered to 40 micron Mounting Wall, panel, 1.5" or 2" pipe (optional) or DIN rail (optional) Enclosure NEMA 4X {IP-65} (conduit connection A only) Materials Housing Chromate-treated aluminum with epoxy paint. NEMA 4X (IP65) Elastomers Buna-N Trim Stainless steel; brass; zinc-plated steel Weight 13.0 oz (0.4 kg)

Type 900X Standard Configurations Electrical Connections Options Terminal Block (T) 2.96 75.2.80 20.3 1/2 inch Conduit Connection (A) 3.12 79.3 1.00 25.4 2.94.500 74.7 12.7 Mounting Holes #10 32 UNF 2B X 3/8 Deep 2 Places 22 GA. wire leads approx. 18" long pos, neg, grd DIN 43650 Connector (D).125 Vent 3.17 3.69 93.7 3.12 79.2 1 NPT 2 1.13 28.7 1.50 38.1 1.80 1.30 45.7 33.0 Back view typical of all units 2.18 55.4 In and out ports 1/4 18 NPT 4 places.516 13.1.383 9.72.766 19.4 M12 Connector (M) 3.01 76.5 4 Pin M12 Connector 3.08 78.2 Mounting Options Pipe Mounting-1.5" or 2" Pipe Order kit # 448-542-005 DIN Rail Mounting Order kit # 445-766-024 3.50 88.9.61 15.5 3.33 84.6 1.43 36.2 1 1/2" Pipe 1.67 42.4 2" Pipe Panel Mounting 1.68 42.7 DIN Rail Kit suitable for EN-50035, EN-50045 and EN-50022 Rails g d

Type 925 Multifunction Supply Manifold A common supply port with individual shut off valves Dimensional Drawings 4.724 120.0 2.559 65.0 Standard inlet fitting 1/2 NPT ControlAir Type 550X Transducer 1.598 40.6 6 1/4 NPT Standard mounting bracket 2.579 1.299 65.5 33.0 Standard end cap Bracket DIN rail 7 3.984 25.0 2 1 1.575 40.0 "A" "B" 4 5 The Type 925 Multifunction Manifold provides a common air supply line to multiple units of our Type 550X and Type 900X I/P, E/P transducers. Manifolds are available to hold 3, 5, 10 or 15 units. Each port features a patented individual shut-off valve that allows safe on-line service or modification with supply pressure on. Individual units may be installed or removed without effecting other units on the manifold. Construction of the manifold is simple and flexible. Connection ports thread easily into the I/P, E/P units. No additional hardware such as check valves or adapter kits are required. The Type 925 is DIN rail mountable (optional). The Type 925 can also be used as a common output manifold for solenoid valves. Ordering Stations Length A Length B in. (mm) in. (mm) 3 6.1 (155) 7.13 (181) 5 9.3 (236) 10.31 (262) 10 17.3 (439) 18.31 (465) 15 25.3 (642) 26.30 (668) Type 925 Manifolds Part Number 3 Unit Manifold Kit 438-544-005 5 Unit Manifold Kit 438-544-006 10 Unit Manifold Kit 438-544-007 15 Unit Manifold Kit 438-544-008 Each kit includes manifold, mounting brackets (2), end cap, 1/2 NPT inlet fitting Diagram # Accessories Part Number 1 1/2 Supply Shut-off Valve 445-778-008 2 1/2 to 1/4 NPT Reducer 445-722-005 3 Pressure Gauge (1/4 bottom mount, 0-60 psig) 446-725-014 3 Pressure Gauge (1/4 bottom mount, 0-160 psig) 446-725-015 4 1/4 Shut-off Valve 445-778-009 5 1/4 Elbow 445-722-004 6 Extended Mounting Bracket Kit (Includes both brackets) 448-544-009 7 DIN Rail Mounting Kit 448-542-004

Type 900X Miniature I/P, E/P Transducer for Electronic Air Pressure Control Output Pressure psig (BAR) Output Pressure PSIG Performance Characteristics Output Pressure psig (BAR) 100 (6.9) 75(5.2) 50 (3.4) 25 (1.7) 2 (0.1) 15 (1.0) 12 (0.8) 9 (0.6) 6 (0.4) 3 (0.2) 15 12 9 6 3 0 0 2.0 (3.4) 0 1.0 (1.7) 4.0 (6.8) 2.0 (3.4) 6.0 (10.2) 8.0 (13.6) 10.0 (17.0) Flow scfm (m3/hr) 3.0 (5.1) 4.0 (6.8) 120 psig supply 12.0 (20.4) 4 8 12 16 20 Input Signal ma 14.0 (23.8) 16.0 (27.2) 5.0 6.0 7.0 8.0 (8.5) (10.2) (11.9) (13.6) Flow scfm (m3/hr) 9.0 (15.3) 100 psig supply 20 psig supply 10.0 (17.0) 11.0 (18.7) 12.0 (20.4) Warranty ControlAir, Inc. products are warranted to be free from defects in materials and workmanship for a period of eighteen months from the date of sale, provided said products are used according to ControlAir, Inc. recommended usages. ControlAir, Inc. s liability is limited to the repair, purchase price refund, or replacement in kind, at ControlAir, Inc. s sole option, of any products proved defective. ControlAir, Inc. reserves the right to discontinue manufacture of any products or change products materials, designs or specifications without notice. Note: ControlAir does not assume responsibility for the selection, use, or maintenance of any product. Responsibility for the proper selection, use, and maintenance of any ControlAir product remains solely with the purchaser and end user. Drawing downloads available at www.controlair.com. Ordering Use this coding system to order Model 900 Input Signal A 4-20 ma C 0-5 VDC D 1-9 VDC E 0-10 VDC F 1-5 VDC Accessories DIN Rail Mounting Kit Kit # 445-766-024 1.5" or 2" Pipe Mounting Kit Kit # 448-542-005 *Field selectable option is available only for units with the following outputs: 3-15 psig, 3-27 psig, 6-30 psig. Hazardous Area Classification Factory Mutual (FM) & Canadian Standards (CSA) Approvals Standard feature for 4-20mA units Intrinsically Safe (1/2" NPT Conduit) Class I, II, III, Division 1, Groups C, D, E, F, & G Enclosure Nema 4X(IP 65) Rated 4-20 ma, 30 VDC Max. Intrinsically Safe (DIN & Terminal) Class I, Division 1, Groups C & D Rated 4-20 ma, 30 VDC Max. Entity Parameters (conduit) Ui (Vmax) = 30 VDC Ii (Imax) = 125 ma Output psig BAR C 3-15 0.20-1.0 D 3-27 0.20-1.8 E 6-30 0.40-2.0 F 1-17 0.07-1.2 G 2-60 0.13-4.1 H 2-100 0.13-6.9 L 0-15 0.00-1.0 I 0-30 0.00-2.1 J 0-60 0.00-4.1 Ci = 0 uf Li = 0 m H Pi =.7 w Max. ATEX Approvals (option K) II 1 G Ex ia IIB T4 1725 Tamb = -40 C to +70 C FM08ATEX0048X Non-Incendive (Conduit,DIN,Terminal) Class I, Division 2, Groups A, B, C & D Suitable for (Conduit only) Class II & III, Division 2, Groups F & G Entity Parameters (DIN and Terminal) Ui (Vmax) = 30 VDC Ii (Imax) = 125 ma Options A Field selectable outputs* (0.20% accuracy) K ATEX Approvals (4-20mA only) U 1/4" BSP Porting Electrical Connection A 1/2" NPT conduit with pigtail D DIN 43650 connector M M12 Connector T Terminal Block Ci =.03 uf Li = 0 mh Pi =.7 w Max. Entity Parameters U: (Vmax) = 30 VDC Ci = 1 uf I: (Imax) = 125 ma Li = 2.2 mh Pi =.7 W Max. 8 Columbia Drive / Amherst, NH 03031 USA / www.controlair.com / sales@controlair.com / 603-886-9400 / FAX 603-889-1844 An ISO-9001:2015 Certified Company P/N 441-625-014 10/17