USER MANUAL MODEL NUMBER: CTX2V-EZB. EZBlend Chemical Transfer Unit. English (Original Instructions)

Similar documents
USER MANUAL MODEL NUMBER: FST FSTK FSTV. Flooded Suction Tank. English

USER MANUAL MODEL NUMBER: FG-10N-2 FG-10NK-2 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: SP-WC AND RELATED UNITS

Wall Mounted Foam Unit MD20016 USER MANUAL

USER MANUAL MODEL NUMBER: GI-5N GI-5NK GI-5NV AND RELATED UNITS. 5 Gallon Air Operated Portable Gel Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: FG-10N-3 FG-10NK-3 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: GI-25N GI-25NK GI-25NV AND RELATED UNITS. 25 Gallon Air Operated Portable Gel Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: SP-20N SP-20NK SP-20NV AND RELATED UNITS. 20 Gallon Air Operated Portable Spray Equipment. English (Original Instructions)

TS5600 TS5600V TS5600K

USER MANUAL MODEL NUMBER: FI-50N FI-50NK FI-50NV AND RELATED UNITS. 50 Gallon Air Operated Portable Foam Unit. English (Original Instructions)

USER MANUAL MODEL NUMBER: FI-WC FI-WCK FI-WCV FI-WC-AP FI-WC-ST AND RELATED UNITS

USER MANUAL MODEL NUMBER: GI-30N-AM GI-30NK-AM GI-30NV-AM AND RELATED UNITS. 30 Gallon Air Operated Portable Gel Unit with Agitator

USER MANUAL MODEL NUMBER: FG-10N-2 FG-10NK-2 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

USER MANUAL MODEL NUMBER: FG-10N-3 FG-10NK-3 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: FI-5N FI-5NK FI-5NV FI-5N-ST FI-5NK-ST FI-5NV-ST AND RELATED UNITS. 5 Gallon Air Operated Portable Foam Equipment

USER MANUAL MODEL NUMBER: FI-30N-SM FI-30NK-SM FI-30NV-SM AND RELATED UNITS. 30 Gallon Smart Foam Unit. English (Original Instructions)

USER MANUAL MODEL NUMBER: FOG-IT6 FG-NA-N130 FG-NA-26SS AND RELATED ITEMS. Wall-Mounted Fog System. English (Original Instructions)

FI-10 FI-10K FI-10V FI-10 ST FI-10K ST FI-10V ST

10 Gallon Portable Air-Operated Foaming Unit

USER MANUAL MODEL NUMBER: GK2T

900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg.

USER MANUAL. 2.5 and 5 Gallon Chemical Transport Jug. English

USER MANUAL. 2.5 and 5 Gallon Chemical Transport Jug. English

USER MANUAL MODEL NUMBER: SS2 SS2-FMH SS2-MBS AND RELATED UNITS

Caution! Pg. 1 of 5 I-932

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

910 BHF OWNER S MANUAL. Pg. 1 of 9

FI-15 OWNER S MANUAL

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Tools Needed for Mounting Cleá Filling Station

Spray & Foam Dispenser Item #

Owner's Manual. Model: LS-PCO-100-GEM ( ) (100 Gallon Skid-Mounted High Pressure Sprayer) Technical Specifications. General Information

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Set-Up Instructions. for EC-VM400. Motorized Valves

Owner's Manual. Model: ( ) (150 Gallon, 5.5 HP Skid Sprayer) Technical Specifications. General Information. Warranty/Parts/Service

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

Heavy Duty Sprayer Owners Manual Model MS-O

Items # and #

WARNING: Do not use pumps for gasoline or highly flammable products! Do not use pumps for water based fluids, solvents or chemicals!

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

Fluid Dispensing Systems

Shaft No. of Part # Old No. Model No. Housing Rotation dia Rollers Seals. NOTE: CI = Cast-Iron, N = Ni-Resist, SL = Silver Last

HIGH PRESSURE SPRAY GUNS &ACCESSORIES

Congratulations PRE-OPERATION SETUP

Shaft Adapter (5/8 to 3/4 ) NOTE CI = Cast Iron, N = Ni-Resist, SL = Silver Last. Series Series 7560

CHAPTER 4 PARTS AND DIAGRAMS

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose:

Table of Contents WARRANTY

SHOP PRO FXP 95 UPGRADE KIT (REGULATED)

OPTIMUS SE-1200 SE-1250 SE-1255

DELUXE TELESCOPING LANCE ASSEMBLY

SP30 10:1 Piston Pump

Page 1 of 19. Part# /10/2006

Silver Selection Sprayers Specification Sheet

Parts and Accessories

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

Used for Safety Shower combination stations: SE-603 SE-616 SE-690 SE-693 SE-695 SE-697

BLACK SHADOW SERIES DISPENSER. Tools Needed for Mounting SCS Dispenser Hammer Drill with 1/4, 1/8, 9/32 and 5/32 Diameter Bits Pliers

MODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO & UP

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

M IJ ET WASHS TAT ION

Owner's Manual. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/2.5 H.P. Engine, 4-Roller Pump, Deluxe Handgun) Technical Specifications

TERMITICIDE APPLICATION TOOLS

Certo Chemical Dilution System

FRS Dispenser (Foam-Rinse-Sanitize) Model # ol Systems. Dilution Control OPERATION SERVICE PARTS CARE

CHEMICALS ONE-WASH ( ) fax (662) HYDROMINDERS HYDROMINDER TIP SELECTOR HYDROMINDERS

ILCS EDGE System Installation Manual

Technical Manual. Table of Contents

Operation, Installation, Maintenance and Repair Guide. HighFlo (HF) Control Handle. SERVICE BULLETIN SB 3097 Rev. A 6/14

Lynx 3:1 Pump. Model: OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE

50 GALLON LAWN & GARDEN SPRAYER

Gregson-Clark SPREADER-MATE

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

Overview: Packing List:

Silver Selection Trailer Sprayers Specification Sheet

TL960 PARTS MANUAL. Fuel Section. Page 9-1. Fuel 09/97

PRESSURISED SANDBLASTER MODEL NO: CPSB200B

BHS1.com Accessories Battery Watering Devices

PRESSURISED SANDBLASTER MODEL NO: CPSB100B PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

F20 Series. Maximum Flow Rate: 1.0 gpm (3.8 l/min) Maximum Pressure: 1500 psi (103 bar) for Metallic Pump Heads

Panther HP Oil Pump Series

DEMA Pro-Fill I Sink Dispenser

B14 AAA FINE FINISH SERIES PUMP OUTFIT

Micro-Injection System

HEAVY DUTY ONBOARD AIR SYSTEM

FRP SystemOne GELCOATER OPERATION MANUAL. MAGNUM VENUS PRODUCTS Operation Manual. Part No. M Revision

E1 Bolted Pump Specifications End Ported Dimensions

CENTRO-MATIC PUMP, MODELS 84050, & 85460

Pro Master 580E OVERVIEW. Detail A Enduraplas. All Rights Reserved. Version 1.1

ULTRABOND Methacrylate Adhesive Dispensing unit IMP-DUO Start-Up Instructions

OWNER S MANUAL. Model: ATV QR ( ) (25 Gallon Deluxe Lawn & Garden/ATV Sprayer) ***IMPORTANT REMINDER*** Technical Specifications

Cleaning Systems Inc. 2 P Rev:03

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

Multi-Sprayer OWNERS MANUAL. Ideal For: Carpet & Upholstery Pre & After Sprays. Ceiling Cleaning. Janitorial Sprays. Carpet Restoration Applications

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

DEMA Pro-Fill II Sink Dispenser

Transcription:

USER MANUAL MODEL NUMBER: CTX2V-EZB EZBlend Chemical Transfer Unit English (Original Instructions)

WARNING Read this manual completely and understand the machine before operating or servicing it. Read all instructions before installing or operating unit. Always wear appropriate personal protective equipment (PPE) when operating or servicing unit. Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data Sheet (SDS). If this unit is modified or serviced with parts not listed in this manual, the unit may not operate correctly. Never point the discharge hose at yourself, another person, or any object you do not want covered in chemical. Do not exceed an incoming air pressure of 100 psi (7 bar). Do not exceed a fluid temperature of 100 F (37 C). Never use unit with hydrocarbons or flammable products. Only use clean and dry air. Air must be filtered and free of moisture or pump life will be diminished. If needed, install a water separator (WS-20CFM) before the unit. Do not use an air lubricator before the unit. Unit must be depressurized when not in use and before disassembling unit or performing maintenance. PROTECT THE ENVIRONMENT Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations. SPECIAL INSTRUCTIONS This chemical dispensing unit is specifically configured for transferring Sterilex products. Acceptable products listed below. ALWAYS AFFIX STERILEX CHEMICAL JUG TAGS TO EACH JUG. CONTACT YOUR STERILEX PRODUCT CHEMICAL VENDOR FOR JUG TAGS. Sterilex Solution 1/ Disinfectant Products Sterilex Ultra Disinfectant Cleaner Solution 1 (US) Sterilex Ultra CIP (US) Sterilex Ultra-Kleen Solution: Solution 1 (Canada) Sterilex Ultra Soft Metal Disinfectant Cleaner (Canada) REQUIREMENTS Compressed air requirements Liquid temperature range Chemical compatibility SPECIFICATIONS Power type Chemical pickup type Number of products unit can draw from Suction line length/ diameter Discharge hose diameter/length Discharge wand/tip type Flow rate* Pump seals Sterilex Solution 2/ Activator Products Sterilex Ultra Activator Solution (US) Ultra Soft Metal Activator (US) Sterilex Ultra-Kleen Solution: Solution 2 (Canada) Sterilex Ultra Soft Metal Activator (Canada) 20-80 psi (1.4-5 bar) with 2 cfm (56.6 l/min) 40-100 F (4.4-37 C) This unit is specifically configured for use with Sterilex liquid products. Compressed air Draws from concentrated product One product per pump, individually or simultaneously 8 ft. (2.4 m) hose with 1/2 in. (12.7 mm) inside diameter 8 ft. (2.4 m) hose with 1/2 in. (12.7 mm) inside diameter Polypropylene trigger handle 3.5 gal/min (13.2 l/min) per pump Viton *Flow rates given are based on chemical with viscosity of water and factory air pressure settings. Always remember to recycle. *Specifications and parts are subject to change without notice. Page 2 of 5 05232018

Installation Instructions: 1. Remove all components from packaging. 2. Select desired area to mount the unit. 3. Mount the unit to the wall using the longer screws (WMS14-2) and plastic anchors (WMS14A) provided in the parts package. Note: To drill holes for the plastic anchors, use a 5/16 inch drill bit. 4. If desired, mount the wand brackets (SSG12H-BRKT) using the screws (WMS14) and plastic anchors (WMS14A) provided in the parts package. 5. With the air inlet valve in the closed position, connect 3/8 inch tubing air line to the air inlet quick-fit (QF1438). Operation Instructions: NOTE: Follow color coding indicators for proper dispensing. Incorrect dispensing may minimize effectiveness of solutions or result in off label product usage. 1. Follow all Sterilex product label instructions when using product. 2. Place the chemical suction line into container of Sterilex concentrate. NOTE: Only use blue chemical suction line for Sterilex Solution 1 product and green chemical suction line for Sterilex Solution 2/Activator product. 3. Open the air inlet valve (BVB14). Verify the quick-fit shut off valves (QFSOV14) are open. 4. Dispense Solution 1 product into 5 gallon jug with blue cap by activating the unit by using the trigger gun (SSG12H). Release the trigger to stop the flow of product. 5. Dispense Solution 2/Activator product into 5 gallon jug with green cap by activating the unit by using the trigger gun (SSG12H). Release the trigger to stop the flow of product. After Use Instructions: Depressurize unit when not in use and before disassembling unit or performing maintenance. 1. Shut off the air supply to the unit by closing the air inlet valve (BVB14). 2. Open the discharge valve (SSG12H) to relieve any pressure remaining in the unit. 3. Close the discharge valve (SSG12H) after all pressure has been relieved from the unit. 4. Complete depressurization process with all discharge valves. Store the unit with the discharge valve (SSG12H) in the closed position. Maintenance Instructions: To keep your chemical transfer unit operating properly, periodically perform the following maintenance procedures: Note: Before performing any maintenance, ensure that the unit has been depressurized according to the After Use Instructions. Inspect the pumps (P56V) for wear and leaks. Inspect all hoses for leaks or excessive wear. Make sure all hose clamps are in good condition and properly secured. Replace the filter (AFR25) located within the air regulator (R25) as needed. Clean by unthreading the air regulator bowl (ABR25) from the air regulator (R25). Check the chemical suction lines and strainers (FV2) for debris and clean as needed. Drain your air compressor tank on a regular basis to help extend pump life. An air source with a high moisture content will accelerate pump wear. Note: If your air source has a high moisture content, you may wish to install a water separator (item number WS- 20CFM, sold separately) before the unit. Troubleshooting Instructions: If air passes through the pump (P56V) without cycling, the pump needs to be replaced. Check for proper air pressure on the air gauge (AG100). The air regulator (R25) is factory set at 50 psi (3.4 bar). Operating range is 20 to 80 psi (1.4 to 5 bar) with 2 cfm (56.6 l/min). If the unit operates at a reduced pressure: oo Check the air compressor supplying the unit. If the pressure is less than 40 psi, turn the unit off until the compressor can catch up. oo If the air supply is 50 psi (3.4 bar) or above, check the air gauge (AG100), which should read near 50 psi (3.4 bar). If the air gauge reads more or less than 50 psi (3.4 bar), adjust the pressure by turning the knob on the top of the air regulator (R25). Check the chemical suction lines and strainers for debris or damage. Clean or replace as needed. To prevent damage to the unit, the strainers (FV2) must always be used. Page 3 of 5 05232018

CTX2V-EZB R25 AG100 QFEL14P QF1438 BVB14 BEL14M14M P56-BRKT P56-BRKT-SCREW P56V H14BU QF14PAF QFSOV14 QFT14 NMCC12 P56-BRKT-SCREW H12B-F H12G-F SHW3 SSC12 FV2 SSC12 SSG12H Page 4 of 5 05232018

ITEM NUMBER AG100 BEL14M14M BVB14 FV2 H12B-F H12G-F H14BU NMCC12 P18 P56V 20756103B HB14P HB5638V P56-BRKT P56-BRKT- SCREW P56-SSPIN DESCRIPTION 1.5 INCH DRY MODEL 20 DUAL SCALE GAUGE ELBOW 1/4in MPT X 1/4in MPT AIR INLET VALVE - VA BRS 025-4F4F-BT, NICKEL FOOT VALVE, VITON, BLUE 1/2 INCH BLUE HOSE-HYBRID TPE-Available per ft. 1/2 INCH GREEN HOSE-HYBRID TPE-Available per ft. 1/4in OD BLUE POLYURETHANE TUBING - Available per ft. 1/2in NONMETALLIC CONDUIT CLAMP PLUG 1/8 MPT HEX HEAD 304 SS PUMP WITH VITON SEALS - INCLUDES HOSE BARBS, AIR FITTING, AND EXHAUST BARB Polypro G57 Air Port x HB Straight, w/ Viton o-ring 1/4in BRASS HB AIR FITTING /G57/P56 HOSE BARB FOR P56V PUMP PUMP BRACKET- STAINLESS STEEL HI LO SCREW FOR RETAINING P56-BRKT STAINLESS DOWEL PIN - 5MM DIA X 30MM LONG PL-CT2 PLATE FOR CTX2 QF1438 QUICK FIT-1/4 MPT X 3/8 OD TUBE-POLYPROPYLENE QF14PAF QUICK FIT-1/4 MPT PUMP AIR FITTING QFEL14P FIXED ELBOW 1/4in TUBE X 1/4in MPT - POLYPROPYLENE QFSOV14 SHUT OFF VALVE 1/4in TUBE - POLYPROPYLENE QFT14 UNION TEE 1/4in TUBE - POLYPROPYLENE R25 AIR REGULATOR - 1/4fpt TWO PORT 1/8fpt TWO PORT - INCLUDES FILTER AND BOWL ABR25 METAL AIR BOWL for R25 AFR25 AIR FILTER for R25 REGBRKT A33-82 BRACKET,MTG SHW3 3in LONG COATED WEIGHT SSC12 STAINLESS SCREW BAND CLAMP FOR 1/2 IN HOSE SSG12H WHITE FILL GUN-1/2IN HOSE BARB-HASTELLOY SPRING SSG12H-BRKT MOUNTING BRACKET FOR SSG12H WMS14 14 X 1 1/4 HEX W/H SMS SLOTT, S/S WMS14-2 1/4in X 2in LAG SCREW STAINLESS STEEL WMS14A 5/16 X 1 1/2 STRAIGHT PLASTIC ANCHOR Page 5 of 5 05232018