File E Vol. 1 Sec. 125 Page 1 Issued: and Report Revised:

Similar documents
Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Amendment to Test Report

Amendment to Test Report

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

COVER PAGE FOR TEST REPORT

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

Power Supply XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

CA/11022/CSA. Lineage Power N/A. Ref. Certif. No. Component DC-DC Converters for Use With ITE

UL TEST REPORT AND PROCEDURE

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

UL TEST REPORT AND PROCEDURE

SPECIFIC TECHNICAL CRITERIA

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

UL TEST REPORT AND PROCEDURE

Installation Couplers intended for permanent connection in fixed installation

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

UL TEST REPORT AND PROCEDURE

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

File E Project 07CA Issued: August 29, 2007 Revised: June 22, 2015 REPORT *COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT

COVER PAGE FOR TEST REPORT

DK M2-UL. Ref. Certif. No. CB TEST CERTIFICATE CERTIFICAT D ESSAI OC. Date: Original Issue Date:

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

Page 2 of 23 UNT150420C11

Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

AS/NZS AS/NZS

TEST REPORT DIN V VDE V

PLUG-IMQ 3/4

TEST REPORT DIN V VDE V

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

SGS Australia Pty Ltd

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

IEC Information technology equipment Safety Part 1: General requirements

This document is a preview generated by EVS

EU RO Mutual Recognition Technical Requirements

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module

Installation Couplers intended for permanent connection in fixed installation

Products :: Circuit Protection :: Thermal Circuit Breakers

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

Certificate of Compliance

< > Page 2 of 84

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

GETTING STARTED GUIDE NI DI, ±5 V to 24 V, Differential/Single-Ended, 500 ns

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

ISO INTERNATIONAL STANDARD

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

File E Project 92ME February 6, 1992 REPORT COMPONENT - POWER SUPPLIES. For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL

RECHARGEABLE LITHIUM-ION BATTERIES FOR SYSTEMS

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

TEST REPORT. IEC 62133: 2012 (Second Edition)

NovitaTech Engineering

ISO 1217 INTERNATIONAL STANDARD. Displacement compressors Acceptance tests. Compresseurs volumétriques Essais de réception. Fourth edition

TEST REPORT IEC Connectors Safety requirements and tests

Packing Data Installation Instructions

Intertek Testing Services Shanghai Address... : Building No.86, 1198 Qinzhou Road (North), Shanghai , China Applicant s name... : GlobTek, Inc.

GETTING STARTED GUIDE NI AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

NI 9251 with mini XLR

LISTING REPORT/INSPECTION PROCEDURE

4CR SERIES MOTOR STARTING RELAY All Position, Current-Type

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT

Test Report issued under the responsibility of: Report Number...:

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Provläsningsexemplar / Preview. Fourth edition

ISO 3934 INTERNATIONAL STANDARD

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements


Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND

Transcription:

File E131905 Vol. 1 Sec. 125 Page 1 Issued: 2007-04-18 and Report Revised: 2009-04-24 DESCRIPTION PRODUCT COVERED: USR, CNR - Switching Power Supply, Models SPASUNM-03, SPASUNM-07, SFP1050-12B, may be followed by suffix G denoting non-safety critical options. ELECTRICAL RATINGS: (Optional) Input _ Output (DC) _ Model V _A Hz V _ A _ SPASUNM-03 100-240 12-5 50/60 V1: 12 86.7 V2: 3.3 3.0 SPASUNM-07 100-110/ 13 50/60 V1: 12 90.8 V2: 3.35 3.0 120-127/ 11 50/60 V1: 12 90.8 V2: 3.35 3.0 200-240 7 V1: 12 99.2 V2: 3.35 3.0 SFP1050-12B 100-240 12 50/60 V1: 12 86.7 V2: 3.3 3.0 ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE): Use - For use only in (or with) Applicant's Information Technology Equipment, where the acceptability of the combination is determined by Underwriters Laboratories Inc. Special Considerations - The following items are considerations that were used when evaluating this product. * USR/CNR indicates investigation to the U.S. and Canadian (Bi-National) Standard for Safety of Information Technology Equipment, Including Electrical Business Equipment, CAN/CSA C22.2 No. 60950-1-07, UL 60950-1, Second Edition, March 27, 2007. The equipment is considered: For building in Class I (earthed), intended for use on a TN power system.

File E131905 Vol. 1 Sec. 125 Page 2 Issued: 2007-04-18 and Report Revised: 2009-04-24 Conditions of Acceptability - When installed in the end-use equipment, consideration shall be given to the following: *1. This component has been judged on the basis of the required spacings in the Standard for Safety of Information Technology Equipment, CSA/UL 60950-1, Second Edition, dated March 27, 2007, Sub-clause 2.10, which would cover the component itself if submitted for Listing. 2. All secondary output circuits are SELV. Output V1 is at hazardous energy level. V2 is not at hazardous energy level. 3. The output connector has not been evaluated for field wiring. 4. The power supply shall be properly bonded to the main protective earthing termination in the end product. 5. Magnetic devices (e.g., transformer, inductor) employ an Unlisted Component (OBJY3)0, Electrical Insulation System, covered under File E137507, Vol. 1, Sec. 3, report issue date 1991-04-05. See report for designated Class. 6. The equipment has been evaluated for use in Pollution Degree 2 environment. 7. A suitable Electrical and Fire enclosure shall be provided. 8. Models SPASUM-03 and SPASUM-07 have been evaluated for use at 45 C ambient. Model SFP1050-12B has been evaluated for use at 50 C ambient. 9. Production-Line Dielectric Voltage Withstand (Electric Strength) and Grounding (Protective Earthing) Continuity Tests are being conducted on this power supply. 10. The Connector Current Interruption Test was performed on the Output Connector (Molex, Type 87667) for 50 cycles (insertion/withdrawal). Testing for additional cycles shall be determined during the end product evaluation, depending on end product application.

File E131905 Vol. 1 Sec. 125 Page 2A Issued: 2007-04-18 and Report New: 2008-11-20 *11. The Clearance values of these power supplies has been evaluated for an altitude up to 3200 m, for models SPASUNM-03 and SPASUNM-07 and up to 3000 m for model SFP1050-12B, under IEC 60664-1: 1992 Table A.2 (altitude correction factor is 1.17 for model 3200 m and 1.15 for 3000 m). 12. This component is not intended for use in vehicles, on board ships or aircraft. 13. The equipment was tested on a 30 A branch circuit. If used on a branch circuit greater or lower than this, additional testing may be necessary. 14. The maximum measured voltage is 556 V pk and the dielectric test voltage was 2594 V dc. Dielectric test voltage in the end product should employ this value.

CERTIFICATE No. P15219559 Order No. 278527 Page 1/2 Product Applicant Manufacturer AC-DC switching power supply Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Factory See page 2 Ratings Trade mark SPASUNM-03 Input: 100-240 VAC, 12-5 A, 50 / 60 Hz; SFP1050-12B Input: 100-240 VAC, 12 A, 50 / 60 Hz Model / Type Ref. Principal characteristics SPASUNM-03, SFP1050-12B where the model name may be followed by G indicating RoHS version See next page(s) A sample of the product was tested and found to be in conformity with OFF EN 60950-1:2006;A11;A1;A12;A2 Validity Additional information This certificate documents conformity with the standards shown, and also applies as license for use of Nemkos name and certification mark. The certificate and license is valid as long as the applicable conditions are complied with, and provided that any changes to the product are notified to Nemko for acceptance prior to implementation. New standards or amendments to the standards may imply that the product design must be updated and/or that re-testing and re-certification is necessary. See next page(s) Additional model(s) The abovementioned certified equipment complies with current regulatory requirements regarding electrical safety in Norway and other EU/EEA member states, as far as this can be checked. Compliance with requirements regarding building-in, protection against electric shock and Electromagnetic Compatibility (EMC) must be checked when the equipment is built-in a completed product or forms a part of a complete system. See next page(s) Date of issue 17-03-2015 Juan Z. Kleppenes Certification Department Nemko AS Gaustadalléen 30, P.O. Box 73 Blindern, 0314 Oslo, Norway TEL +47 22 96 03 30 FAX +47 22 96 05 50 EMAIL info@nemko.com ENTERPRISE NUMBER NO974404532 nemko.com

CERTIFICATE No. P15219559 Order No. 278527 Page 2/2 Product AC-DC switching power supply Pos. No 1 Model / Type Ref. SPASUNM-07 Trade mark (if different from page 1) Rating Principal characteristics Input: 200-240 VAC, 7 A, 50 / 60 Hz where the model name may be followed by G indicating RoHS version Factories: BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District, Shenzhen 518108 China Bel Power Solutions, s.r.o. Areal ZTS 924 Dubnica nad Vahom 01841 Slovakia Date of issue 17-03-2015 Juan Z. Kleppenes Certification Department Nemko AS Gaustadalléen 30, P.O. Box 73 Blindern, 0314 Oslo, Norway TEL +47 22 96 03 30 FAX +47 22 96 05 50 EMAIL info@nemko.com ENTERPRISE NUMBER NO974404532 nemko.com

Ref. Certif. No. NO85680 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI DACCEPTATION MUTUELLE DE CERTIFICATS DESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la deuxième page Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) AC-DC switching power supply Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Additional information on page 2 SPASUNM-03 Input: 100-240 VAC, 12-5 A, 50 / 60Hz SFP1050-12B Input: 100-240 VAC, 12 A, 50 / 60Hz Type of Manufacturer s Testing Laboratories used Type de programme du laboratoire d essais constructeur Model / Type Ref. Ref. De type SPASUNM-03, SFP1050-12B Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire, peuvent être indiqués sur la deuxième page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport dessais numéro de référence qui constitue partie de ce Certificat where the model name may be followed by G indicating RoHS version Additional information on page 2 IEC 60950-1(ed.2);am1;am2 278527 This CB Test Certificate is issued by the National Certification Body Ce Certificat dessai OC est établi par l'organisme National de Certification Gaustadalléen 30 NO-0373 Oslo, Norway Date: 17-03-2015 Signature: Juan Z. Kleppenes Certification Department Issued 2007-04 1/2

Ref. Certif. No. NO85680 BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District, Shenzhen 518108 China Bel Power Solutions, s.r.o. Areal ZTS 924 Dubnica nad Vahom 01841 Slovakia Gaustadalléen 30 NO-0373 Oslo, Norway Date: 17-03-2015 Signature: Juan Z. Kleppenes Certification Department Issued 2007-04 2/2

Test Report issued under the responsibility of www.nemko.com Report Number....: 278527 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Date of issue...: 13 March 2015 Total number of pages...: 57 Applicant s name...: Bel Fuse Inc. Address...: 206 Van Vorst St., Jersey City, NJ 07302 Test specification: Standard...: IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 Test procedure...: CB-Scheme Non-standard test method...: N/A Test Report Form No.... : IEC60950_1F Test Report Form(s) Originator...: SGS Fimko Ltd Master TRF...: Dated 2014-02 Copyright 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report. This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.

Page 2 of 57 Report No 278527 Test item description... : AC-DC switching power supply Trade Mark...: Manufacturer...: Same as Applicant Model/Type reference...: SPASUNM-03, SPASUNM-07, SFP1050-12B (maybe followed by G indicating RoHS version) Ratings...: SPASUNM-03 Input: 100-240 VAC, 12-5 A, 50 / 60 Hz SPASUNM-07 Input: 100-110 VAC, 13 A, 50 / 60 Hz, 120-127 VAC, 11 A, 50 / 60 Hz, 200-240 VAC, 7 A, 50 / 60 Hz SFP1050-12B Input: 100-240 VAC, 12 A, 50 / 60 Hz Input _ Output (DC) _ Model V _A Hz V _ A _ SPASUNM-03 100-240 12-5 50/60 V1: 12 86.7 V2: 3.3 3.0 SPASUNM-07 100-110/ 13 50/60 V1: 12 90.8 V2: 3.35 3.0 120-127/ 11 50/60 V1: 12 90.8 V2: 3.35 3.0 200-240 7 50/60 V1: 12 99.2 V2: 3.35 3.0 SFP1050-12B 100-240 12 50/60 V1: 12 86.7 V2: 3.3 3.0 Testing procedure and testing location: CB Testing Laboratory: Testing location/ address... : Associated CB Testing Laboratory: Testing location/ address... : Tested by (name + signature)... : Nemko USA Inc. 2210 Faraday Ave. Suite 150, Carlsbad, CA 92008, USA Luis Gonzalez Approved by (name + signature)... : Jeff Busch Report History: Original report TRF No. IEC60950_1F

Page 3 of 57 Report No 278527 List of Attachments (including a total number of pages in each attachment): Attachment 1: European Group Differences and National Deviations... 84 pages Documented deviations contain individual national documents for several European countries that are already documented in the European Group Deviations. The European Group Differences: EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 are considered Normative. The individual national documents (Denmark, Finland, Germany, Ireland, Norway, Spain, Sweden, Switzerland and United Kingdom) are considered Informative and included at the manufacturer s request. Attachment 2: Miscellaneous Documentation, e.g. Photos, PWB Layout, Schematic etc.... 35 pages (Not for publication Engineering use only) TRF No. IEC60950_1F

Page 4 of 57 Report No 278527 Summary of testing General Power supply All comments relate to all models, unless specifically stated. The equipment is an enclosed, Class I switch mode power supply with universal AC input and multiple DC voltage outputs for building-in. This report covers multiple models and all comments / tests apply to all models unless otherwise indicated. 1.1.2; The unit is intended to operate at an altitude over 2000 m. This equipment is intended to be operated at an altitude of up to 3200 m (models PASUNM-03G, SPAUNM-07G), so the clearance is multiplied by the altitude correction factor (1.17), This equipment is intended to be operated at an altitude of up to 3000 m (SFP1050-12B), clearance is multiplied by the altitude correction factor (1.15) specified in table A.2 of IEC 60664-1 2 nd Edition:2007-04. Refer to Tables 2.10.3 and 2.10.4. 1.5, 3.2.5; Power supply cord set. A power supply cord set is not provided with the power supply. A power supply cord set, complying with the national regulations of the country in which the product is to be sold, shall be provided with the end-use equipment. 1.7.2; Safety instructions. Instructions and equipment markings related to safety are to be provided in a language, which is acceptable in the country in which the equipment is to be sold. English language verified. 1.7.2.4; IT power distribution systems The equipment complies with the requirements for connection to the Norwegian IT power systems. The following information should be given (but is not required) in the installation instruction: This product is also designed for IT power system with Phase to Phase voltage 230V. 2.7.4; Number and location of protective devices. In Norway, IT power distribution system is used. Equipment with a single protective device is accepted in Norway. Other countries may have additional requirements. Equipment normal configuration is provided with a single fuse (F1) in the line phase of the input, however the power may be supplied with an optional fuse (F2) in the neutral phase of the input. 2.7.6; Warning to service personnel. After operation of the protective device, the equipment is still under voltage if it is connected to an IT-power system. A warning is required for service personnel. Norway does not require this warning. 5.2: Electric Strength test Increased test voltages for Basic insulation applied to the equipment, based on measured working voltages. TRF No. IEC60950_1F

Page 5 of 57 Report No 278527 Summary of testing: Tests performed (name of test and test clause): 1) Input... 1.6.2 2) Durability... 1.17.11 3) Capacitance Discharge... 2.1.1.7 4) SELV Reliability... 2.2 5) Protective Bonding... 2.6.3.4 6) Humidity... 2.9.2 7) Working Voltage Measurement... 2.10.2 8) Hazardous Voltage Measurement... 2.10.2 9) Handle Loading... 4.3.2 10) Connector Interruption... 4.3.5 11) Heating... 4.5.1 12) Touch Current... 5.1 13) Electric Strength... 5.2.2 14) Component Failure... 5.3 15) Abnormal Operation... 5.3 16) PS Output Overload and Short... 5.3 Testing location: See page 2 Summary of compliance with National Differences: List of countries addressed: Austria (AT), Australia (AU), Canada (CA), China (CH), Denmark (DK), Finland (FI), Germany (DE), Ireland (IE), Israel (IS), Korea (KR), Norway (NO), Slovenia (SI), Spain (ES), Sweden (SE), Switzerland (CH), United Kingdom (GB), United States of America (US) The product fulfils the requirements of : EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 Copy of marking plate: The artwork may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. (Additional requirements for markings. See 1.7 NOTE) TRF No. IEC60950_1F

Page 6 of 57 Report No 278527 Calibration Measurement uncertainty Evaluation of results All instruments used in the tests given in this test report are calibrated and traceable to national or international standards. Further information about traceability will be given on request. Measurement uncertainties are calculated for all instruments and instrument set-ups given in this report. Calculations are based on the principles given in the standard EA-4/02 (Dec. 1999), IEC Guide 115:2007, Nemko routine L227 and other relevant internal Nemko-procedures. Further information about measurement uncertainties will be given on request. If not explicitly stated otherwise in the standard, the test is passed if the measured value is equal to or below (above) the limit line, regardless of the measurement uncertainty. If the measured value is above (below) the limit line, the test is not passed - ref IEC Guide 115:2007, and Nemko routine L220. The instrumentation accuracy is within limits agreed by IECEE-CTL (ref. Nemko routine L227). TRF No. IEC60950_1F

Page 7 of 57 Report No 278527 Test item particulars: Equipment mobility... : [] movable [] hand-held [] transportable [] stationary [ X ] for building-in [] direct plug-in Connection to the mains...: [ X ] pluggable equipment [ X ] type A [] type B [] permanent connection [] detachable power supply cord [] non-detachable power supply cord [] not directly connected to the mains Operating condition...: [ X ] continuous [] rated operating / resting time: Access location...: [] operator accessible [] restricted access location Over voltage category (OVC)...: [] OVC I [] OVC II [] OVC III [] OVC IV [ X ] other: Mains supply tolerance (%) or absolute mains supply values... : -10%, +10% Tested for IT power systems... : [] Yes (Norway only) [ X ] No IT testing, phase-phase voltage (V)... : 230V Class of equipment...: [ X ] Class I [] Class II [] Class III [] Not classified Considered current rating of protective device as part of the building installation (A)...: 30 A Pollution degree (PD)... : [] PD 1 [ X ] PD 2 [] PD 3 IP protection class... : IP x0 Temperature, Ambient ( C)... : 45 C maximum (SPASUNM-03, SPASUNM-07) 50 C maximum (SFP1050-12B) Relative Humidity (RH)... : 10% to 85% RH Altitude during operation (m)... : 3200 m (SPASUNM-03 and SPASUNM-07) 3000 m ( SFP1050-12B); Altitude of test laboratory (m)... : 38 m Mass of equipment (kg)... : 1.6 kg Possible test case verdicts: - test case does not apply to the test object... : N/A - test object does meet the requirement... : P (Pass) - test object does not meet the requirement... : F (Fail) Testing: Date of receipt of test item... : February 2015 Date(s) of performance of tests... : February 2015 March 2015 TRF No. IEC60950_1F

Page 8 of 57 Report No 278527 General remarks: "(see appended table)" refers to a table appended to the report. "(see Enclosure #)" refers to additional information appended to the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. Throughout this report a comma / point is used as the decimal separator. Manufacturer s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided... : When differences exist; they shall be identified in the General product information section. Name and address of factory (ies)... : Yes Not applicable Bel Power Solutions, s.r.o. ArealZTS Dubnica n.vahom c.924 01841 Dubnica nad Vahom SLOVAKIA BPS Asia Pacific Electronics (Shenzhen) Co.,Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District 518108 Shenzhen PEOPLE'S REPUBLIC OF CHINA TRF No. IEC60950_1F

Page 9 of 57 Report No 278527 General product information: This test report is based on a TUV SUD test report Ref. No. SI12000112133-00 with appended CB cert Ref. No. DE -59750, evaluated to the requirements of IEC 60950-1:2005 2 nd ed. + A1:2009. This test report includes an upgrade to IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013, an addition evaluation of the power supply to the requirements of IT power systems (Norway only) and an evaluation of the Leakage at the output of the PSU. For continuity, data from the original TUV report is included in this report, along with the additional evaluation referenced. Models SPASUNM-03 and SPASUNM-07 are a front-end rectifier, for building in. Provided with AC inlet, fan and I2C communication. The unit can be used on hot-swappable redundant system. Model SPASUNM-03 and SPASUNM-07 can be operated at maximum 45 C ambient. Model SFP1050-12B can be operated at 50 C. Model differences: Model SPASUNM-03 is the base model. Model SPASUNM-07 is similar to SPASUNM-03 except for input and output ratings, chassis material, PWB insulator shape, chassis cover provided with heatsink and provided with thermal protection RT3 on heatsink HS2. Model SFP1050-12B is similar to SPASUNM-03 except for additional front bezel, input current, input inductor L1, L2, capacitors C2, C15, C16, inductor L4, Main and Logic PWB, longer bottom chassis and maximum operating ambient temperature. Conditions of Acceptability: When installed in the end use equipment, the following are among the considerations to be made: The following must be evaluated at end use: 1) A suitable fire enclosure. 2) A reliable ground (Protective Earth) connection. 3) Operator access with a tool. 4) Energy hazard protection. 5) Interconnection of equipment. 6) A reliable disconnecting device. 7) Enclosure test. Abbreviations used in the report: - normal conditions... N.C. - single fault conditions... S.F.C - functional insulation... OP - basic insulation... BI - double insulation... DI - supplementary insulation... SI - between parts of opposite polarity... BOP - reinforced insulation... RI Indicate used abbreviations (if any):... None TRF No. IEC60950_1F