TENSION DISPLAY PANEL ALS8A MA Current Loop input

Similar documents
TENSION DISPLAY PANEL ALS8A mv/v input signal

ALS6A100 BACKUP DISPLAY PANEL Operations and Maintenance Manual

MAGNETIC MARK INTENSIFIER AMS5A105

AM3KA520 COMBINED DEPTH/TENSION MEASUREMENT DEVICE WITH 4-20MA TENSION AMPLIFIER

AMS 3K COMBINED DEPTH/TENSION MEASUREMENT DEVICE WITH LOW VOLTAGE TENSION AMPLIFIER

36220 FM 1093 P. O. BOX 850 Simonton,Texas Phone: Fax: benchmarkwireline.com

AM3K COMBINED DEPTH/TENSION MEASUREMENT DEVICE

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

AMS 3K COMBINED DEPTH/TENSION MEASUREMENT DEVICE

DP140e. Installation & Operations Manual

AM5K COMBINED DEPTH/TENSION MEASUREMENT DEVICE. Baker Atlas. AM5KA509 (CH) one encoder, no MMD. AM5KA517 (OH) two encoders, MMD, Zone 2 F

CONTROLLER DIAGNOSTIC GUIDE

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

AM5K COMBINED DEPTH/TENSION MEASUREMENT DEVICE ATEX ZONE 2 CE HALLIBURTON ENERGY SERVICES CONFIGURATIONS

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Crane Systems GREER COMPANY. LALT 1151L System for Lattice Cranes. Installation and Calibration Manual. 1 of 39

AM5K COMBINED DEPTH/TENSION MEASUREMENT DEVICE Zone 2 - Class 1 Div 2 For Open & Cased Hole or Cased Hole E-Line Logging STANDARD CONFIGURATIONS

Division Systems TM Baggage Scale System. Product Specifications

Low Pressure Sensor. Overview. Specifications. Installation and Operation

FP-100 Fuel Pressure and Ammeter Indicator Page 1 of 16. All specification subject to change Aerospace Logic Inc.

DPS280 / DVS280 Series

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

CALIBRATION MANUAL. GREER COMPANY Crane Systems LALT SYSTEM for HYDRAULIC CRANES

Series 10-ZSE40A(F)/10-ISE40A

ECONOMISER SERIES E2T USER MANUAL

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

Battery Fuel Gauge Specification

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

POWER AMPLIFIER SERVICE MANUAL CONTENTS

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

********SERVICE MANUAL********* MODELS:

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Fincor Series 2230 MKII/2240

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Transmitter CSA-591 Instruction Manual

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

Super Brain 989 The Pinnacle of Performance with Power to Spare User s Manual Model Rectifier Corporation

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

ZT-1 Tonnage Load Module By Toledo Integrated Systems User s Manual

Emergency lighting units EM series

CENTRIFEEDER ELECTRONICS

SAFETY NOTICES INSTALLATION MANUAL SAFETY NOTICES / 1. Safety notices are one of the primary ways to call attention to potential hazards.

Super Brain 969 Pro AC/DC Delta Peak Charger with Dual Output and Discharge Function Instruction Manual Model Rectifier Corporation

Super Brain 977. AC/DC Charger with Dual Output and Discharge Function. User s Manual. Model Rectifier Corporation

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

InBin-P Pressure switches 5 Pa Pa

SWII Users Manual. Intercomp Co County Road 116 Minneapolis, MN (763) Fax

CATALOG OF REPLACEMENT PARTS SLICERS (INCLUDES MOTOR PARTS) A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

USER MANUAL. Insulation Tester + DMM. Model MG320

User s Manual. Automatic Switch-Mode Battery Charger

Intercomp. PT300 Users Manual. Manual #: E

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

LAN Power Supply Module.

MUNTIFUNCTION SURVEY METER

RS Stock No

Installation Instructions

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

Emergency lighting units EM powerled


Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

ValveMate 7000 Controller Operating Manual

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS

Chek-A-Cell TM TestEquipmentDepot.com. Instruction Manual Rev A 8/12

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

SERVICE MANUAL (INTERNATIONAL)

INSTALLATION INSTRUCTIONS AM rev. A

General_technical_data Series

MODEL 908. Read Instructions Carefully! Fuel Gauge CURTIS INSTRUMENTS, INC.

Patient Lift Scale Indicator Owner s Manual

CD3000S-1PH Thyristor Unit Analog Input version

SPA MICROPROCESSOR COMBINED TACHO&SPEEDO/GAUGE INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS

LM 3188 PORT: LASER DUST MONITOR

Digital display Pressure range ON/OFF output Linear output Model

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

DIESEL Engine Fire Pump Controllers Features

2-Color Display High-Precision Digital Pressure Switch

PRODUCT INFORMATION BULLETIN

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

QUANTUM LX CONTROL PANEL

THUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions

Transcription:

TENSION DISPLAY PANEL ALS8A120 4-20MA Current Loop input Oct-2010 Rev B Page 1 of 14

1.0 GENERAL DESCRIPTION The 4-20MA Tension Display panel is designed to be an independent tension measurement indicator for mounting inside a wireline unit. The tension signal is read from a load cell connected to a wireline sheave or from a load pin in the measuring head. It can be displayed in either pounds or kilograms at the display unit. The unit is powered by three internal batteries. It can be connected to an external AC or DC power source to keep the batteries charged. An external output is provided to allow the panel to be connected to an analog gauge to show tension. The unit is designed to operate without intervention from the user. When external power fails, the display is maintained by the batteries. If the input is inactive for more than one hour the unit switches itself off. Front panel controls allow the operator to: Zero the tension reading Select a different settings using the menu button Switch the power off manually (for use when running on battery power) The unit is switched on automatically, when external power is restored, or When the user selects the enable switch on the front panel 2.0 OPERATING PROCEDURES 2.1 Turn the unit on by pressing the enable switch up. If external power is applied, the unit will power on automatically. 2.2 Select the appropriate settings from the menu (see section 4.0) 2.3 The system is now ready to measure tension. Oct-2010 Rev B Page 2 of 14

3.0 DESCRIPTION OF FEATURES 3.1 Enable Switch The ENABLE/OFF switch is a center-biased three position switch. If you push the switch down, the panel stores the menu setting in the nonvolatile memory and switches the unit off if not on external power. The unit cannot be switched off when connected to external power. The display unit forces you to use two switches, to prevent accidental loss or corruption of the depth display value. The up position (ENABLE) does several things: The unit powers on, and the unit re-displays the stored value. Enable is also required to zero the tension. 3.2 Menu Switch This button is used to change the internal settings of the panel. These settings include Load Cell type, Scales, Load Cell Angles, English/Metric units, etc. Refer to section 4 for detailed description of these features. 3.3 Zero Switch The ZERO switch allows you to zero the display, it is a two position momentary switch. To activate this switch, you must hold the ENABLE switch up, then press this switch. 3.4 Increase / Decrease Switch The INCREASE/DECREASE switch is a center biased three position switch. Use this switch to change values in each menu. 3.5 EXT PWR LED There is one LED on the front panel of the display unit. The LED is lit when the unit is connected to an external power source, either 240/120 vac or 12 vdc. If the LED is not lit, then the unit is operating off of battery power. Oct-2010 Rev B Page 3 of 14

4.0 MENU SELECTIONS The internal settings of the panel can be set by pressing the menu button. IMPORTANT NOTE: To change a setting, press and release the menu button until the desired setting is displayed. Use the +/- switch to change the setting. After a setting is changed, continue pressing the menu button until you pass the last setting. At this time you will be asked if you want to ACCEPT the setting changes. To accept the changes press + then the MENU button. If you press or wait for four seconds, the changes will be ignored. If you wait for four seconds between switch presses, the panel will time out and go back to displaying depth. 4.1 LINE SIZE OR LOAD CELL FULL SCALE 4.1.1 LINES SIZE (WITH HEAD TYPE 3K OR 5K) When the menu button is pressed once, the panel will display LS and then Line Size stored in the system. Use the +/- switch to change the display until desired line size setting is displayed. IMPORTANT NOTE: If the first menu is FS then the Load Cell is selected as the head type. Refer to 4.3 for information regarding full scale values. Line sizes will be displayed as the following options: LS 3:16-3K and 5K LS 7:32-3K and 5K LS 9:32-3K and 5K LS 5:16-3K and 5K LS 3:8-3K and 5K LS 7:16-5K only LS 15:32-5K only LS 15d - 5K only LS 472-5K only LS 472d - 5K only LS 484-5K only LS 492-5K only LS 17:32-5K only Oct-2010 Rev B Page 4 of 14

4.1.2 FS LOAD CELL The panel will display Hd_LC for the Load Cell when Head Type LC is selected. The panel will display FS XY.AB where X is tens of thousands of pounds, Y is thousands of pounds, A is hundreds of pounds and B is 10 s of pounds. Use the +/- switch to select the setting the desired setting. PANCAKE STYLE LOAD CELL (typically used on the BenchMark tension test stand) This value is located on the load cell tag. See the following example. This is an Example of a load Cell Tag. Note: This tag will be used for full scale and sensitivity values. Oct-2010 Rev B Page 5 of 14

COMPRESSION LOAD CELL WITH HYDRAULIC GAUGE (typically used with a Martin Decker hydraulic load cell installed in a measuring head). Multiply effective area of the of the surface area by the full scale PSI value of the electrical transducer connected to the load cell. Example 1: A typical 5000 pound MD Totco load cell has a area of 4.02 sq inches. If a transducer with a full scale reading of 500 PSI is used then the number to be entered would be 2010 pounds. Example 2: A typical 10,000 pound MD Totco load cell has a area of 6.44 sq inches. If a transducer with a full scale reading of 1475 PSI is used then the number to be entered would be 9500 pounds. Oct-2010 Rev B Page 6 of 14

4.2 DISPLAY CALIBRATE RESULT If the panel is connected to a load cell that includes a calibrate or shunt cal function, the calibrate signal will be displayed at this time. 4.3 UNITS MENU Press the menu button again and the panel displays UN for units. Select LB for pounds or Hg for Kilograms. Note: Remember to move to menu 4.4 to accept these changes. 4.4 HEAD TYPE Press the menu button again and the panel displays Hd for Head type. Select 5H for the 5k head or 3H for the 3K Head. The line size menu will then be the first option on the menu (4.1.1.) Select LC for use with the load cell. This setting is used for the pancake style load cell on the top of the tension test stand. When using the load cell, the line size menu will be replaced with the FS or full scale menu. 4.5 ACCEPT/DISCARD CHANGES Press the menu button again and the panel displays ACCEPt. If you want to accept the changes put the +/- switch in the + position. The panel displays YES. Pushing the menu button writes the new values to flash. If you want to discard the changes put the +/- switch to the - position. The panel will display NO. Push the menu button again. Oct-2010 Rev B Page 7 of 14

5.0 INSTALLATION AND MOUNTING 5.1 INSTALLATION PROCEDURE 5.1.1 Prepare an appropriate panel cut-out with four fixing holes (refer to drawing in section 6.1) or use one of the two mounting brackets shown below (section 5.2). 5.1.2 Connect the tension input cable to the rear of the unit. 5.1.3 Ensure that power is off. Connect the unit to a 12vdc or 120/240 vac power supply. 5.1.4 Insert the display unit into the panel and secure it at the four corners. 5.1.5 Ensure that the unit is setup for the desired measurement units (pounds or kilograms). 5.1.6 Before you start to use the display unit, leave it connected to the external power for 4 hours to ensure that the batteries are fully charged. Oct-2010 Rev B Page 8 of 14

5.2 MOUNTING KITS 5.2.1 AMS4A161 PIVOTING MOUNT 5.2.2 AMS4M110 PLATE MOUNT TOP VIEW FRONT VIEW SIDE VIEW Oct-2010 Rev B Page 9 of 14

6.0 SPECIFICATIONS 6.1 Mechanical Material Weight Mounting Aluminium, anodized 1.5 lbs (.68 kg) 4.019 holes fixing centers: 6.19 (19.05 cm) from side, 2 (5.08 cm) from top/bottom. 6.2 Environmental IP Rating 40 Temperature 0 to + 50 Centigrade Humidity 10% - 80% RH non-condensing. Oct-2010 Rev B Page 10 of 14

6.3 Electrical Input power Voltage Input power frequency Input power current 100-240 VAC or 12 24 VDC 50-60 Hz, DC 0.4 A 6.4 Batteries Battery Voltage Lifetime 2100 mah 1.2 V NIMH Approx. 5 years (depending on usage) The batteries are trickle charged when external power is connected to the unit. The batteries are fully charged after 3 hours. The batteries discharge if the unit is left unpowered for a few weeks. 6.6 AC Power Input Live Brown White Neutral Blue Black Earth Green/Yellow Green Power is fused inside the display unit case with a 250 ma fuse 6.7 DC Power-input Live Pin 1 Neutral Pin 2 Earth Pin 3 DC connector spec: AMS4P257 -CONN KPT06E8-33P 3 PIN Oct-2010 Rev B Page 11 of 14

The battery voltage and charge current can be displayed by pressing enable and menu at the same time. The voltage will be displayed as: E 4180 4180 would be a battery voltage of 4.18 volts. When the battery reaches 4.8v the charge will stop. The charge current will be displayed as: A 310 310 would be a battery charge current of 310 ma. The display will cycle between the voltage and current display as long as the buttons are being depressed. The charge current is limited to between 250 ma and 350 ma. Oct-2010 Rev B Page 12 of 14

7.0 PARTS LISTS AND DIAGRAMS 7.1 PARTS LISTS ALS8A120 TENSION DISPLAY PANEL LINE NO. PART NO. DESCRIPTION QTY REFERENCE ALS6M001-1 2 PANEL FR TENSION BKUP PNL MT 1 2 ALS8M009 PANEL REAR TENS BKP 4-20 1 4 ALS6M004 CHASSIS BACKUP DISPLAY PNL TOP 1 5 ALS6M005 CHASSIS BACKUP DISPLAY PNL BTM 1 6 C276P366 CONN MS3102E-14S-5S 1 LOAD CELL 7 AMS4P257 CONN KPT02E8-33P RECEPTACLE 1 8 AMS4P039 CONN MS3102E-14S-5P 1 TENS OUT 9 AMS4P569 LCD 6 DIGIT.71" REFLECTIVE TN 0 10 ALS8A021B PCB ASSY TENSION BU 4-20 1 12 AMS4P621 POWER SUPPLY 12V 7W 85-264ACIN 1 15 C276P155 CABLE BELDEN 177431 10' AC 1 16 AMS4P276 RECEPTACLE 115/240 VAC FUSED 1 17 AMS4P786 FUSE 0.5A 250V 5X20MM GLASS 2 18 AMS4P618 BATTERY 1.2V NIMH AA 2100MAH 6 22 AMS4P021 SWITCH CAP ALCO C-22 BLACK 1 MENU SW 23 AMS7P017 SWITCH CAP ALCO C-22 RED 1 ZERO SW 28 AMS4P631 NUT 1/4-40 DRESS BRIGHT NICKEL 4 31 AMS4P659 CONN TERMINAL RECPTACLE.25TAB 3 35 AMS7P022 CONN 102398-6 AMP 16 POS PCB 1 36 AMS7P026 CONN 102536-6 AMP 16 POS BACK 1 37 AMS7P025 CONN 102681-3 AMP 16 POS FRONT 1 38 AMS4P661 CONN HOUSING 3POS 2.5MM SHROUD 1 39 AMS4P662 CONN FE TERMINAL CRIMP 2.5MM 4 40 AMS4P663 CONN HOUSING 2POS 2.5MM SHROUD 1 41 ALS8P041 HOLDER BATT 6AA W 9V SNAP CON 1 42 ALS8M057 TRAY BATTERY 6XAA BK TENSN 1 43 ALS8M037 CLAMP BATTERY 6XAA BKUP TENSN 1 44 ALS8P042 SPACER ROUND PHENLC #6 X 1-1/2 2 48 ALS8P043 SCREW 6-32 X 2 PHIL PAN SST 2 49 ALS6P033 SCREW 4-40 X 3/16 FH PHIL SST 2 BATTERY HOLDER 50 ALS6P085 SCREW 4-40 X 1/4 FH PHIL SST 14 51 AMS8P091 SCREW 4-40 X 1/4 PHIL PAN SST 12 52 AMS8P036 WASHER #4 LOCK SST 12 53 ALS8A121 PLUG SHORTING ALS8A120 1 Oct-2010 Rev B Page 13 of 14

7.2 INTERNAL VIEW TOP Note position of the three batteries. USE ONLY 1.2V NIMH AA 2100MAH BATTERIES WARNING DO NOT USE NON RECHARGEABLE BATTERIES AS THEY ARE LIKELY TO EXPLODE WHEN CHARGED Oct-2010 Rev B Page 14 of 14