OPTEC 1000 DMV VISION TESTER

Similar documents
AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

Preface. Scope of Application. General Requirements for Safety THE SAFETY MARKS USED IN THIS INSTRUMENT

1,000,000 Rechargeable Spotlight

Stereo Microscopes Instruction Manual

Model QuadraFlare DOT

Service Manual. Model Number: DF2426GB DF2426SS DF2550 DF2562. UL Part Number to 500

INSTRUCTION SHEET FOR SIGNALMASTER MODELS SM518A AND SM428A

Advisory Bulletin. TB-99 Cleaning and Maintenance For Bobrick B-824 or B-828 Automatic Counter-Mounted Soap Dispensers B-824 B-828

MOVING HEAD. User manual CAUTION!

Mania EF1 user manual

Operation and care of the Visual Optics Fiber Scopes

MANUAL EXC-120 MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

FiberSource Q150. user manual P/N

SR500 PAPR How to Copyright 2015 by The S.E.A. Group 1

Spotlight 1,000,000 Power Series Cordless Rechargeable


I1 7.5 Pre-Lit Clear Christmas Tree

ME310B BATTERY POWERED CRIMP TOOL

AFE8B BATTERY POWERED CRIMP TOOL

Sylvania 7.5 Pre-Lit Lindberg Pine Tree 500 Clear Incandescent Lights-One Plug Tree Tree ID #C15, Item # V

Tactical Laser Illuminator

Riverside. Placid Cove Entertainment PIER Assembly Instructions. Pier Left & Right Item # THANK YOU FOR YOUR PURCHASE.

Ego 01 Ego 02 Ego 03 Logo Projector user manual

HPFB. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

LED Twister II. User manual UK Version 1.0

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1

USER MANUAL LUX-LD30W LED MOVING HEAD

USER MANUAL TACTICAL FLASHLIGHTS. Triple Duty P4 & Triple Duty Q5

7.5 Oregon Fir With SYLVANIA Multi Color Mini Lights and Multi Color G50 Soft Glow Lights Pre-Lighted Tree V69139 INSTRUCTION MANUAL

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

16" STAND FAN WITH REMOTE

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

INSTALLATION INSTRUCTIONS

OBY-5. User manual MOVING HEAD CAUTION!

INSTALLATION INSTRUCTIONS

USER S MANUAL TUBE SEALER. Model SE700. No. CAT.SE70011Ce

HD4170 SETUP & OPERATOR MANUAL. Performance Design Inc East Braniff St. Boise, Idaho 83716

WIRELESS CAMPER JACK LITERATURE NUMBER REV. C CCD WARNING PERSONAL INJURY & PROPERTY DAMAGE WARNING EXPLOSION. Effective NOV 2018

Easy Packer. Industrial Case Erecting, Packing and Taping System. User Guide

Installation Instructions

XPERT SL 45 Slit Lamp. Instruction Manual

CM1000C CM1800C ChangeMakers. Operator s Manual. Seaga Manufacturing, Inc. 700 Seaga Drive Freeport, IL USA

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

CH-158 Color Bank 8 USER MANUAL

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL S Rear. Front METRIC SAE. Level of Difficulty. Parts List. Product Image. Tools Required. Notes and Maintenance

INSTALLATION INSTRUCTIONS

NICHE-HV. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES B

INSTALLATION INSTRUCTIONS

SCION xd INTERIOR LIGHTING UPGRADE Preparation

6.5 Multi Function C5 LED Pre-Lighted Tree Pre-Lighted Tree 96842

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree

USER MANUAL SLIT LAMP MICROSCOPE

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

Mania DC3 user manual

POWERED RUNNING BOARDS INSTALLATION MANUAL

PRELIMINARY INSTALLATION INSTRUCTIONS PARTS LIST. Combination light switch Right fog light. 4 Self-tapping washer-screws.

XCEL 250 XCEL 400/700. Xcel Slit Lamp USER'S GUIDE Rev. F Page1

User Manual Stealth s Power Tilt

INSTALLATION INSTRUCTIONS

Vision Ped Plus. Operators Guide. Studio Pedestal. Vinten Camera Control Solutions

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

Duo Massager. Cordless Shiatsu & Percussion Massager

SERIES 80/81/82 STROBE AND HALOGEN PERIMETER LIGHT HEADS INSTALLATION & OPERATION MANUAL IMPORTANT: SERIES 80/81/82 STROBE AND HALOGEN

INSTALLATION INSTRUCTIONS

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

Contents INTRODUCTION

USER S MANUAL & WARRANTY INFORMATION

INSTALLATION INSTRUCTIONS

AP250 Automated Projector

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Mini Aquatic ORDERCODE 30844

Product Data Sheet : LIGHTHAWK 6 CELL

INSTALLATION INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

9' Warm White /Multi LED Color Changing M5 One Plug tree V INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS

Motion System Components Diagram. Note: #2 Mirror Cover and X-Axis Motor Cover have been removed for visibility. Maintenance.

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Ichip Mystére LED FOLLOWSPOT USER MANUAL

WIRELESS TRI-JACK WIRELESS REMOTE KIT COMPONENTS LITERATURE NUMBER REV. C WARNING EXPLOSION WARNING PERSONAL INJURY & PROPERTY DAMAGE

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

BUICK SKYLARK/GS

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

USER MANUAL PAR56 LED PAR CANS

SERIES 6000 FILM OPACITY METER MODEL RT REV A.1 INSTALLATION & OPERATION MANUAL

FOR INDOOR/SEASONAL USE ONLY

M200. Battery Charger. For lead-acid batteries. User Manual and Guide to professional charging of starter and deep cycle batteries.

Non-Contact Phase Rotation Tester

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ITEM #75618 Sylvania Staylit 7.5 ft. Sherwood Pine Pre-lit Tree MODEL #V

ECO Spot 2500 User Manual

INSTALLATION INSTRUCTIONS

Transcription:

INSTRUCTION AND MAINTENANCE MANUAL OPTEC 1000 DMV VISION TESTER Stereo Optical Company, Inc. 8600 W. Catalpa Ave., Suite 703, Chicago, IL 60656 USA Phone: 1.773.867.0380 or 1.800.344.9500 Fax: 1.773.867.0388 Email: Sales@StereoOptical.com www.stereooptical.com Copyright 2017 Stereo Optical Company, Inc. Optec is a registered trademark of Stereo Optical Company, Inc.

TABLE OF CONTENTS I. Vision Testing 1 II. Operating the Control Panel of the OPTEC 1000 1 III. Administering the Tests 4 V. Maintenance of the OPTEC 1000 Vision Tester 5

I. VISION TESTING To be a skillful tester you must become familiar with the OPTEC 1000 Vision Tester. Look into the instrument and note what happens when the eye switches are ON and OFF. It is important to recognize whatever the subject may be describing and be able to answer any questions. Concentrate on acquiring a smooth delivery of instruction and description of the test target. The tester's expertise can help relax the subject, get better cooperation and a more accurate response. When speaking to the subject, never act surprised or provoked by their responses or lack of response. Give the subject every opportunity to demonstrate their best vision. If the subject is wearing glasses or contact lenses, they should wear them during the testing to determine whether they meet the requirements for corrected vision. The table or counter should be of convenient height with surface space for the instrument. Normal room lighting is acceptable, but care should be taken to avoid light shining on the lenses or on the subject's face. II. OPERATING THE OPTEC 1000 The first step is to connect the control panel to the instrument. Connect the multi-prong plug to the back of the control panel. The plug will fit in only one way. Push the plugs together and tighten the screw on each side of the plug. You should not have to unplug the control panel once you have joined the instrument and panel together. Plug control panel into an electrical outlet by using the black cord with the three (3) prong plug. (110 V AC) 1

CONTROL PANEL OPERATIONS CONTROL SWITCHES: From left to right; (see figure #1) TOP ROW: Figure #1 First: Right Eye Switch: Orange color; when the switch is turned ON (depressed) the right eye will see the target, when the switch is turned OFF (raised) the right eye will see nothing. Second: Left Eye Switch: Green color; same as above. When both switches are ON together, the subject will see with both eyes (binocularly). Third: Day/Night Control: White color; when this switch is raised, daylight conditions are simulated in the instrument. When the switch is depressed, night-time conditions are simulated in the instrument. Most testing is done under day-light conditions. Fourth: Power Switch: Red color; this controls the power for the instrument. Depressed, the power is ON. Raised, the power is OFF. 2

Fifth Ready Light: Green color; this will light when the subject applies pressure to the headrest trigger and is in the proper position to be tested. MIDDLE ROW: Perimeter Test First: Yellow Color: 45 nasal perimeter test. When the switch is held down, a momentary light will flash in the face plate. The light will appear on the opposite side from the side you are testing. Second: Blue Color: 55 temporal perimeter test Third: Blue Color: 70 temporal perimeter test Fourth: Blue Color: 85 temporal perimeter test These switches are momentary. They will only flash as long as pressure is applied and will flash along the side you are testing. The same switches are used for testing both right and left sides. Turn the eye switch off for the eye not being tested. BOTTOM ROW: Test Switches First: TEST #1: White color; depress switch and test will be illuminated. Press again to turn illumination off when test is finished. Proceed to TEST #2. Second, Third and Fourth: TEST #2, #3 AND #4: White color; same as above. If you are only doing one test, you can leave it on and the light will go off or on automatically as the subjects apply pressure to the headrest trigger. 3

III. ADMINISTERING THE TEST Turn the power on by depressing the red power switch. Depress the two eye switches--orange and green, being sure the white switch (day/night) is NOT depressed but in the raised position. Pull off the first headrest tissue so there is a clean tissue available for the subject. Have a subject step forward and adjust the height of the instrument. Have the subject hold the instrument with both hands, one on each side, looking into the lenses. The subject's forehead should press against the headrest trigger. The green ready light on the control panel should light. Depress the switch marked TEST #1 and administer the test. Check your score key for correct answers. Depress switch marked TEST #1 again so it will turn off. Proceed to switch marked TEST #2 for the next test. Continue this process until all testing is completed. PERIMETER TESTING Ask the subject to look straight ahead. Use the top line of the center column of an acuity test as a fixation point. Turn left eye off (switch raised). Press the switches in the middle row of the control panel in any sequence. Ask the subject to point to where they see a light flashing. Once you have gone through all four positions, turn the left eye on and the right eye off, following the same procedures. IMPORTANT CHECKPOINTS: Be certain the instrument is plugged into a 110-120V AC outlet. 4

Push RED power switch on control panel to activate the instrument. Check both eye switches to be certain they are depressed (ON). Tear off headrest tissue so a clean tissue is ready for the next subject. Be certain the subject presses their forehead against the headrest trigger so the illumination in the unit is activated and the GREEN "READY" indicator on the control panel is lit. Be certain you have a score key available. IV. MAINTENANCE OF THE OPTEC 1000 VISION TESTER Stereo Optical's OPTEC 1000 Vision Tester was designed to minimize maintenance. It has been engineered and built for a lifetime of use. The only annual maintenance required is simple and does not necessitate a service call. There are no moving parts with the OPTEC 1000. The only components requiring occasional maintenance are: EYEPIECE LENSES: The external sides of these lenses need to be cleaned occasionally (see figure #2). Care should be taken not to use any abrasive material on these lenses. Use the cleaner supplied with the vision tester. It is important to dry the lenses with a soft cotton cloth or tissue. CLEANING OF SLIDE: Open the slide cover door and remove the slide. Use a damp soft cloth or tissue with lens cleaner and wipe both sides of the slide. 5

EXTERIOR: The aluminum and ABS plastic of which the instrument body is made can be cleaned with a damp cloth and a mild detergent. Make sure control panel is disconnected. CHANGING LIGHT BULBS: When you have a burned out bulb, identify which test is affected. Turn the power (RED switch) off. Unplug the instrument from the electrical outlet. Remove screws from top left and right rear of instrument. Take a firm grasp of the two knobs in the center of the back door and pull back and down (see figure #3). The door will open and the eight (8) light bulbs will be exposed (see figure #4). With two fingers slide the burned-out bulb and socket out. Replace the bulb with a blue coated bulb, (Optec 2000-226). It is suggested that you replace the bulb opposite the burned out one at the same time. Slide the socket and bulb back into the track with the screw head on the socket top, on the outside of track. Close the door and replace the two screws. Turn power back on by plugging the cord into wall socket and depressing the red switch. You are now ready to continue testing. Figure #2 6

Figure #3 Figure #4 7

Stereo Optical Company, Inc. 8600 W. Catalpa Ave., Suite 703, Chicago, IL 60656 USA Phone: 1.773.867.0380 or 1.800.344.9500 Fax: 1.773.867.0388 Email: Sales@StereoOptical.com www.stereooptical.com Copyright 2017 Stereo Optical Company, Inc. Optec is a registered trademark of Stereo Optical Company, Inc. PN 70099