CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card

Similar documents
AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

with the AgGPS TrueGuide System Quick Reference Card

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Installation Instructions ISOBUS Liquid ECU

Quick Setup Guide for IntelliAg Model YP Air Pro

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

CONTROL SYSTEMS FOR PRECISION FARMING. IntelliAg puts the future of application control in your cab providing state-ofthe-art

System User Interface

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev.

Quick Setup Guide for IntelliAg Model YP Twin Row

Population pre-def ned Every Row Population. For other pre-def ned are made to the system or if options are added to the base planter.

Planting. Press to Highlight Configuration. Gauge Wheel Load Alarm. Value must be entered for your specific planter and parallel arm combination

Quick Setup Guide for IntelliAg Model YP

ROW PRO DOWN PRESSURE

400 INSTALLATION & OPERATION INSTRUCTIONS

SureFire Drives and Harnesses for use with John Deere Dry Rate Controller

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

Diagnostic Trouble Code (DTC) List

Display Quick Reference Guide

Full screen alarms identify abnormal or failed operation on all enabled system components/controls

Raven RS1 Guidance and Steering Calibration & Operation Manual. P/N Rev. A 09/17 E29677

Endeavor Fertilizer Controler" Electric Pump Fertilizer System for John Deere GS2 with Servo Control

Matrix Pro GS. Setup Guide. For use with software version 3.0x. TeeJet Aabybro Mølhavevej 2 DK 9440 Aabybro Danmark

ISOBUS Product Control Installation & Operation Manual. Manual No Rev. F 7/16 E28148

INSTALLATION INSTRUCTIONS ALL JOHN DEERE SYSTEMS

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

Driver s Display. ALFA-Elite & ALFA-Pro. Owners Manual. Rev 1.2, July (Preliminary) (September 21, 2012) Small Systems Specialists

844-E Sprayer Control. Installation, Programming and Operating

24V1 Spray Controller

CONTENTS 1.0 INTRODUCTION SAFETY... 5

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

Y1. Troubleshooting / Service Guide for SureFire PWM Liquid Application Systems. SureFire Commander II Controller

Reference Manual /12

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev.

Do isolate the power supply from other high power systems such as Stereos and Alarms

Advanced User Manual

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

OPERATING INSTRUCTIONS AutoForce

Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

Spray Height Controller

AQUIS Foam System. Installation, Operation, and Maintenance Instructions AQUIS 1.5, AQUIS 3.0, and AQUIS 6.0

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION

AGRICULTURAL PRODUCTS JOHN DEERE AG MANAGEMENT SOLUTIONS John Deere 4640 Universal Display Equipment for Base Machine

RADION Automatic sprayer control Software version 1.07

I. SIM card preparation 3 II. Installation into a vehicle 3. III. Most common issues and their solutions 9 III. Attachments 10

To get started with RLINK, install the RLINK Smart Device on your bike using this guide.

System Background and Operation

TASC-6100 LIQUID/GRANULAR APPLICATION CONTROL SYSTEM USER GUIDE PN R2 Software Version 1.30

ALFA-Club. Owners Manual Rev 4.0, August Small Systems Specialists 201 N. Lobb Ave. Pen Argyl, PA Memory Checkpoint Clock

Calibration & Operation Manual

CEBIS and controls guide. CLAAS LEXION combines

PATRIOT 2240 SELF-PROPELLED SPRAYER

All machines one language

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00

SmartFOAM. Electronic Foam Proportioning Systems. Models: Class A only 1.7AHP, 2.1A Class A/B 3.3, 5.0, 6.5 FOAM OPERATION QUICKSTART FSG-MNL-00179

Spray Height Controller

Field-IQ & PumpRight for PWM Control. Pump Models & Flow Capability. Max Flow GPM

An ISO 9001:2008 Registered Company

ECHO Enhanced Controller Hook Count Application *** Infrared Photo Sensors *** GCA 110 ECHO Controller. Version 3.5

Mega 475

Installation and User Manual. with RAIN SENSOR.

Appendix 9: New Features in v3.5 B

Operating instructions

Installation and Operations Manual

MAGPOWR Spyder-Plus-S1 Tension Control

Module 13 Rate-controller functions and settings Getting the best out of the functions available

USER S GUIDE LandAirSea 7100 Real Time GPS Tracking System

KONGSKILDE KONNECT 1000

Indian Speedometer and Body Control Module Service Tool Users Guide

Hardi. Precision Defined. precision Spray Height Control

Components. Options Accessory Harness USB Charger. Quick Connector. Hook & Loop / Cable-ties. RFID Antenna. Module. Main Harness.

RECON ZONE BLOCKAGE AND FLOW MONITOR INSTALLATION MANUAL. Document revision: 1.2 Last revised: October 25, 2017

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

DeltaForce System Operation

NexSysLink. Operation Manual. NMEA 2000 SAE J1939 Indmar Engines. CAN Instruments Product Family

User Manual By Firstech LLC, Version: 1.0

Ahi template for Taranis and Horus. Setup Guide

SOFTWARE OPERATING GUIDE

Seed Rate Controller Operators Manual

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

AUTOMATIC TRANSMISSION (5AT)

SCS 440 SERIAL INTERFACE INSTALLATION AND SERVICE MANUAL

Seed-Squirter. Installation Guide. APPLICATION SYSTEMS FOR PROFESSIONALS. How Can We Help?

USER GUIDE 1 USER GUIDE

Release Notes. Release Notes Contents. Overview. New Vehicle Coverage - Summary: Version

B. Ford Fusion 2013-up

NORAC Rogator Operator s Manual

Vehicle Security System

CS 430RC. Solid De-icer Controller Configuration and Set-up Manual

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

User Manual By Firstech LLC, Version: 1.0

MicroGuard 586. Operation/Setup Manual MG-586. Crane Systems. Rated Capacity Indicator/Limiter System GREER COMPANY. Page 1 of 44

User Manual. Applicable to the following remote(s) 600R / 700R FCC ID : VA5JR260A433. Toll Free : th Ave S Kent, WA 98032

DJ - RAM 2500 PICKUP - 6.7L I6 CUMMINS TURBO DIESEL

Gillig EFAN Diagnostic Software User Guide & Troubleshooting Guide 8A Rev H Last Revised: 3/23/2017

WIRELESS BLOCKAGE MONITOR OPERATOR S MANUAL

3200NT Timer Service Manual

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

Transcription:

CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card RUN SCREEN The Trimble CFX-750 display is a touchscreen display that is configured and run by tapping the icons that appear on the display screen. The image below shows the run screen when using the Field-IQ system with firmware version 4.00. c d Item Notes c Quick Access icon Access common Field-IQ settings, including tank setup and refill. d Pump arming status Pump armed Pump disarmed e f g h i j k l e Target rate The target application rate for the current rate switch position. This is the amount of product that you want to apply. f Actual rate The actual application rate. This is the amount of product that is currently being applied. g Rate switch position Indicates the current position of the rate switch. Rate 1 1 Rate 2 2 Manual M h Section control Shows the current position of the section control switch. i Location Shows the current location and material. Automatic Manual j Master switch status Shows the current position of the master switch. On Off Jump start k Section and control Indicates the current status of the sections. l Sensor status You can add up to two sensors to this location with their setup name. For more information, see Sensor setup (page 5). 1

Before you start Installing Field-IQ hardware Warning: Anhydrous ammonia (NH3) can cause severe burning, blindness, or death. Before you begin to operate or service equipment that contains NH3 or any other chemical, carefully read and follow all safety instructions in the CFX-750 Display User Guide. For information on installing Field-IQ system, refer to the Field-IQ Installation Instructions. For the latest versions of these documents, go to www.trimble.com/agriculture. Help The CFX-750 display has built-in, context-sensitive Help that lets you quickly find information you need. To access Help from any configuration screen, tap. When you are finished with the Help screen, tap. Note - For more information on how to use this product, refer to the latest version of the CFX-750 Display User Guide. Setting up the Field-IQ system on the CFX-750 display Navigating the display: Tap to return to a previous screen. Tap to discard all changes and start again. 1. In the guidance screen, tap Settings and then tap Implement 2. Tap Application Control. 3. If you are setting the system up for the first time, tap Initial Setup. If you have previously installed the Field-IQ system, more options will appear. Implement Setup. 4. In the Controller Type screen, tap Field-IQ and then tap. 5. A summary screen appears. Verify that all hardware that was installed is recognized and then tap. Implement setup 1. From the Implement Operation drop-down list, select Spraying. 2. Implement Layout. 3. Set the Implement Measurements. The options are: Implement Width Number of Rows Overlap / Skip Left/Right Offset Forward/Back Offset Implement Draft Total width of the implement. Not used for sprayers. Needs to be higher than the number of sections. Distance of overlap or skip between passes. Distance the implement is off from the center line of the tractor. Distance of the application point from the antenna (for manual guidance) or from the fixed axle (for the Trimble EZ-Steer, EZ-Pilot, or Autopilot system). Distance that the implement is drafting. 4. Set up the Implement Switch, if applicable. The options are: Number of Switches Min Changed Switches Number of implement switches hooked up to the Field-IQ system. Number of switch changes that are required to show the implement in a lifted state. For example, if three switches are hooked up to the Field-IQ system and this setting is set to two, the system must see two switches in the lifted position before the implement appears as lifted on the display. 2

Material Setup 1. In the Application Control screen, tap Material Setup. 2. Tap New Material. 3. Material Type. 4. Enter a Name for the material. 5. Set the Application Rates. The options are: Target Rate 1 Target Rate 2 Target Rate Increment Manual Rate Increment Minimum Rate Maximum Rate Preset rate for position 1 on the rate switch. Preset rate for position 2 on the rate switch. Rate increase/decrease when the rate adjustment switch is clicked once. Value increase/decrease when the increment switch is clicked when the rate switch is in the manual position. Minimum rate that can be applied. Maximum rate that can be applied. 6. Complete the Operation Setup. The options are: Jump Start Speed Shutoff Speed Minimum Override Speed The speed the control system will use when the switch is in this position. The speed at which the system will shut down. If the speed is below this value, the control system will act as if it is still at this speed. Control (Location) Setup 1. In the Application Control screen, tap Control Setup. 2. If this is the first time you are setting up a control, tap Unassigned. 3. Enter a location name. 4. For Material Assignment, select the material set up previously. 5. For Material Control, indicate if you are using switch boxes or the display only. 6. Set up Section Control. a. If you select On, enter the number of modules for this location and select the module serial number(s). The options are: Number of Sections Control Type Turn Off When Stopped Number of sections assigned to the module The Boom Valve where the section control module sends power to the section valve to turn the clutch on is the most common for sprayers. If yes, the sections turn off when stopped. b. If required, set up additional section control operations. The options are: Latency On: Length of time between when the command to turn sections on and application actually begins. Off: Length of time between when the command to turn sections off and application actually ends. Apply Latency to Boundary Rate Snap If yes, the latency values apply to field boundary and exclusion zones. When on, if the Applied Rate is within 10% of the Target Rate the Applied Rate is displayed as the same value of the Target Rate. Latency Command given to turn off 3

Overlap Coverage Allowable Rate Error Start Overlap: The amount of intentional overlap when going into a non-covered section of the field. End Overlap: The amount of intentional overlap when going into a previously covered area. Start Overlap End Overlap Coverage Switching Overlap: The amount of side-to-side coverage overlap before a section shuts down. 1% 99% Boundary Switching Overlap: The amount of side-to-side boundary overlap before a section shuts down. 1% 99% Coverage allowable rate error. c. If required, set Fence Nozzles. If Right or Both is selected, the option for Right Nozzle Wiring appears. the wiring configuration of your sprayer to ensure control of the correct section for right fence nozzle: b. In Drive Setup, complete the Valve Setup. The options are: Valve Type Plumbing Servo: Standard 2-wire servo, performs more slowly. Servo Fast: Fast 4-wire servo, performs more quickly. PWM: 2-wire PWM valve, commonly used to control hydraulic flow to the pump. Hardi % Bypass Servo: Used on Hardi sprayers equipped with 3-way section valves that return flow to the tank when the boom section is off. Pump Servo: Servo valve commonly used to control hydraulic flow to the pump. Electric Over Hydraulic: A valve that uses electric current to control the hydraulic valve output. Set the valve plumbing for servo-type valves only (that is, Servo, Servo Fast, and Hardi % Bypass Servo). Note Pump Servo does not have a plumbing type as it controls hydraulic flow to the pump. This is similar to a PWM setup. The options are: Inline: The control valve is between the pump and the sections/nozzles. This means that the control valve controls the amount of material out to the section/nozzles directly. Note To increase the amount of material that is sent to the section/nozzles, the control valve must open more in order to force more material to the sections/ nozzles. Bypass: The control valve is between the pump and the tank. This means that the control valve controls the amount of material that goes back to the tank. Note To increase the amount of material that is sent to the section/nozzles, the control valve must close more in order to force more material to the sections/ nozzles. 7. Set up Rate Control. a. If On, enter the number of drives for this location and select the module serial number(s). If there is more than one module, select the width associated with the module. Auxiliary Valve Pump Disarming Switch Disabled, Master, or Dump Disabled or Enabled 4

c. Also in Drive Setup, complete the Feedback Setup: Flow Meter Type Flow Meter Units Flow Meter Calibration Minimum Flow The options are: Raven Trimble Navigation Limited Other Other Other (per cu in) The options are: Pulses/gallon Pulses/liter Enter the value on the meter if available. This value will be updated following flow meter calibration. The system minimum flow that is maintained when the rate is going to be below this value. d. In the Rate Control Setup, set up the Tank/Bin if required: Status When on, the system will track the tank level and provide warnings. 8. Set up Sensors. The most common sensors are pressure, speed, and bin/tank. Sensor Name Module Assignment Input Location RPM Calibration Alarm on Change Alarm Text Enter a name for the sensor. Serial number of the module the sensor is connected to. Applies to Pressure Sensors Only. Location the pressure sensor is connected to on the module. Applies to RPM Sensors Only. The pulse per revolution for the sensor. Applies to Bin Sensors Only. Low to High: The alarm is triggered when the module sees the sensor go from 0 V to 12 V. High to Low: The alarm is triggered when the module sees the sensor go from 12 V to 0 V. Applies to Bin Sensors Only. Enter the text to be displayed when the alarm is triggered. Capacity Units Capacity Current Volume Partial Refill Warning Level units. The total volume of the tank. The volume of material currently in the tank. The amount of a partial refill. The amount of material that triggers a low material warning. e. In the Rate Control Setup, enter the Number of Nozzles. 5

Calibration 1. In the Application Control screen, tap Calibration. 2. the Location you set up earlier. 3. Implement Lift Calibration, if applicable, and follow the steps on the screen 4. Rate Control and Drive Calibration and follow the steps on the screen. 5. Rate Control and Flow Calibration and follow the steps on the screen. 6. Sensor(s) and calibrate accordingly. Calibrate Maximum Flow During calibration, the maximum flow value is required. This is calculated as follows: (boom width in feet) x (ground speed in mph) x (application rate in gpa) x 0.00202 Changing the Minimum Override Speed To change the Minimum Override Speed at which the system will continue to run at if the vehicle drops below this speed: 1. From the Run screen, tap Settings. 2. Implement. 3. Application Control. 4. Material Setup. 5. your previously set up material and then tap Edit. 6. On the Material Management screen, tap. 7. Minimum Override Speed and then enter the required value. Saving your current configuration To save your current configuration, including all settings and calibration information: 1. From the Run screen, tap Settings. 2. System. 3. Advanced. 4. Save/Load Configurations. 5. Save Current Configuration. 6. Save the configuration to the internal memory (to reload if unwanted adjustments are made) or to a USB drive (to have an external backup and be able to move between displays). Note: To load a saved configuration, follow this procedure, but select Load a Configuration in Step 5. Spraying Corners 1. Drive around the corner. 2. When you have passed the corner and straighted up, stop the vehicle: 3. Switch the Section Control Switch on the Master Switch box to Manual and the Master Switch to Off. 4. Reverse the vehicle until the spraying implement is at the field boundary: 5. Hold Master Switch on the Master Switch Box at Jump Start position and begin driving. 6. When up to speed, release Master Switch and set at ON position. 7. When pass the previously covered area, switch the Section Control Switch on the Master Switch Box back to Automatic: 6

Operation Once you have enabled, configured and calibrated your Field-IQ crop input control system, the Run screen appears (see page 1). This allows you to control the application. The LED has the following status indicators: Green The unit is powered and is communicating with the CFX-750 display. Yellow The unit is initializing communications with the CFX-750 display. Red The unit is powered but not communicating with the CFX-750 display. Field-IQ master switch box All systems must have a Field-IQ master switch box. c Switch Increment/ decrement Functions Increases the applied amount by a set amount (to set this amount, go to Material Setup / Application Rate Setup / Rate). d Rate Choose preset Rate 1, preset Rate 2, or Manual. e c d e f Automatic/ Manual Automatic mode Sections automatically turn on and turn off sections when entering areas of overlap, non-apply zones, or crossing boundaries. Manual mode Sections are controlled manually. f Master A. Jump start. The system is overridden to use preset control speed. Use if you lose a GPS signal or want to start applying before the implement is up to speed. B. On. Sections and rate ready to be commanded by the display. C. Off. Sections are closed, rate set to zero. a b c Field-IQ 12-section switch box The 12-section switch box is required for section control. For rate control only, the switch box is optional. Only one section switch box can be used on each system. Each section switch is automatically assigned to the corresponding module. The modules are read from left to right. For example, switch 1 assigns to the module furthest on the left when standing behind the implement. The section switches have different functions, depending upon the status of the master Automatic/Manual section switch on the master switch box. If the section control switch on the Master Switch Box is set to... and an individual section switch position on the 12-section switch box is... then... Automatic Up / On the section is controlled by the display. Down / Off the section is off. Manual Up / On the section is turned on. Down / Off the section is off. 7

CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card 2013. Trimble Navigation Limited. All rights reserved. Trimble, the Globe and Triangle logo, and EZ-Steer are trademarks of Trimble Navigation Limited, registered in the United States and in other countries. CFX-750 and Field-IQ are trademarks of Trimble Navigation Limited. Version 4.00, Rev A (June 2013). 8