Module 6. Actuators. Version 2 EE IIT, Kharagpur 1

Similar documents
LECTURE 24 TO 26 - HYDRAULIC CIRCUIT DESIGN FREQUENTLY ASKED QUESTIONS

Basic Electrically-Controlled Hydraulic System

Pneumatic Systems. Module 3: Logic Operations in Electropneumatics. IAT Curriculum Unit PREPARED BY. August 2008

LECTURE 15 TO 17 DIRECTIONAL CONTROL VALVES FREQUENTLY ASKED QUESTIONS

Lecture 25 HYDRAULIC CIRCUIT DESIGN AND ANALYSIS [CONTINUED]

Name common, basic subsystems that compose

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Lesson 5: Directional Control Valves

Experiments on Hydraulic and Pneumatic circuit trainers HYDRAULIC CIRCUITS:

FLUID POWER P&IDs. IDENTIFY the symbols used on engineering fluid power drawings for the following components:

three different ways, so it is important to be aware of how flow is to be specified

DISCUSSION OF FUNDAMENTALS. A hydraulic system can be controlled either manually or automatically:

Actuators and directional control valves

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

Hydraulic energy control, conductive part

Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Considerations on Flow Regeneration Circuits and Hydraulic Motors Speed Variation at Constant Flow

Input, Control and Processing elements

5.2 to 79 gpm 3000, 3600, 5000 psi

Chapter 6 Pneumatic Logic Sensors and Actuators

DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Sub. Code/Name: ME1305 Applied Hydraulics and Pneumatics Year/Sem: III/V

Chapter 19. Applying Pneumatic Power. Typical Circuits and Systems

FRL unit consist of Filterations, Regulators and Lubricator unit.

The CASCADE Method. IA Cascade Method

What does pressure refer to in relation to hydrostatics and what is it dependent on?

CH.6 Hydraulic and Pneumatic Circuits/20M. 6.1 Hydraulic Circuits

: Automation Laboratory 1

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Hydraulic Circuit Design

Fluidics. Hydraulic circuit. Course teacher Prof. Mahbubur Razzaque

Basic Machine Interface Options

t2_ il PioC Oper. led Relet Valve Symbol ~~~ CHAPTER 12 Pilot Operated Pressure Control Valves

Applications of Pneumatics and Hydraulics

Projekthandbuch. Project Manual Industriehydraulik. Industrial Hydraulics RE 00846/ Trainee's manual. Schülerhandbuch

Series PAVC Variable Volume, Piston Pumps

Definitions of Technical Terms

ENERPAC hydraulic valves are available in a wide variety of models and configurations.

Module 6 Assignment Part A

BASIC PNEUMATICS BASIC PNEUMATIC CIRCUITS LEARNING ACTIVITY PACKET BB834-BA02XEN

Chapter 13: Application of Proportional Flow Control

Using Hydraulic Systems

Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance.

Shaper Automation Using Electro-Pneumatic Devices And Plcs

Basic Hydraulics and Pneumatics

Series CNS. Cylinder with Lock Double Acting, Single Rod - X X1166. ø125, ø140, ø160. How to Order. Without auto switch With auto switch

Project Manual Industrial Hydraulics

Test. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder Answer:

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications

For system diagrams and component identification

Learning System for Automation and Communications. Electropneumatics. Workbook Basic Level S1 K1 K1 Y1

JIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.

Workshop Instructions CA 152. Hydraulic Circuit Diagrams W1521EN1,

2. Hydraulic Valves, Actuators and Accessories. 24 Marks

HYDROTRAINER-200 Hydraulics - Electro-hydraulics

University of Jordan School of Engineering Mechatronics Engineering Department. Fluid Power Engineering Lab

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

The pneumatic circuit and parts' list needed to perform this operation are shown by Figure C.1.

speed hydraulic motors. Permission granted to reproduce for educational use only. Contrast the operation of fixed- and variable-

Proportional Directional Valve System

Basic Hydraulics. Module 2: Actuators and directional control valves. Curriculum Development Unit PREPARED BY. August 2013

DIRECTIONAL CONTROL (LD) DIRECTIONAL AND FLOW CONTROL (LD) SOLENOID OPERATED DIRECTIONAL

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

I) Clamping the work piece II) Drilling the work piece. III) Unclamping the work piece. 10

Series circuits. The ammeter

EManually Operated Directional Valves

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

SDigital vs. Analog Sensors

Module 6: Air Foundation Brakes

Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive

Where theree are hydraulic transmissions where there are YUCI products

Introduction. Pre-Lab

PNEUMATIC & HYDRAULIC SYSTEMS

Discrete Control Logic. 1. Pneumatic circuits. - Low forces - Discrete, fixed travel distances - Rotational or reciprocating motion

Pneumatic Trainer Kit

Directional Controls

Mobile control block, 6-way version sandwich plate design. Type SM12, series 1X RE /05.03

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

High Pressure, High Flow Rate Modular Valves

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

EManually Operated Directional Valves

Marine Engineering Exam Resource Review of Hydraulics

LECTURE-23: Basic concept of Hydro-Static Transmission (HST) Systems

Lecture 7. Lab 14: Integrative lab (part 2) Lab 15: Intro. Electro-hydraulic Control Setups (2 sessions)

Unit C: Agricultural Power Systems. Lesson 1: Understanding Principles of Operation of Internal Combustion Engines

Electropneumatics Basic Level Set of Overhead Transparencies TP 201

application and are used in chemical injection systems (water

Design and Fabrication of Sequencing Circuit with Single Double Acting Cylinder

Pneumatic Control System

Automatic Control System PS Pneumatic Training System. Features

Pneumatic & Hydraulic SYSTEMS

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

[You may download this article at: ]

Appendix A. Standard Symbols for Hydraulic Components

Introduction. General Information. Systems Operation

Manual Proportional Directional Control Valve (with Pressure Compensation, Multiple Valve Series)

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Transcription:

Module 6 ctuators Version 2 II, Kharagpur 1

Lesson 28 Industrial Hydraulic ircuits Version 2 II, Kharagpur 2

Lesson Objectives fter learning the lesson students should be able to escribe typical industrial actuation problems Interpret hydraulic system symbols and circuit diagrams escribe techniques for energy saving in hydraulic systems Introduction ypical hydraulic circuits for control of industrial machinery are described in this lesson. Graphical hydraulic circuit diagrams incorporating component symbols are used to explain the operation of the circuits. ase Study I: Unloading System for nergy Saving n unloading system is used to divert pump flow to a tank during part of the operational cycle to reduce power demand. his is done to avoid wasting power idle periods. For example, it is often desirable to combine the delivery of two pumps to achieve higher flow rates for higher speed while a cylinder is advancing at low pressure. However, there may be considerable portions of the cycle, such as when the cylinder is moving a heavy load, when the high speed is no longer required, or cannot be sustained by the prime mover. herefore, one of the two pumps is to be unloaded resulting in a reduction of speed and consequently, power. he components of this system are:, : Hydraulic pumps,, : ilot operated Spring loaded Relief valves, : heck valve Mode 1: oth umps Loaded In Figure 28.1 below, when both pumps are delivering, oil from the pump passes through the unloading valve and the check valve to combine with the pump output. his continues so long as system pressure is lower than the setting of the unloading valve. Version 2 II, Kharagpur 3

M Fig. 28.1 Unloading ircuit Mode 2: One pump unloaded In Fig. 28.1, when system pressure exceeds the setting of the unloading valve, it makes pump to discharge to the tank at little pressure. lthough the system pressure, supplied by pump, is high, the check valve prevents flow from through the unloading valve. hus only pump now drives the load at its own delivery rate. hus the load motion becomes slower but the power demand on the motor M also reduces. If the system pressure goes higher, say because load motion stops, pump discharges when its relief valve settings would be exceeded. oints to onder: 1. an you imagine what would happen, if the check valve was not present?. How would you modify the system if you wanted to unload pump instead of pump? ase Study II: Selection of System Operating ressure he circuit shown in Figures 28.2-28.4 allow selection of operating pressure limits in a hydraulic system from three options, namely, two maximum pressures, plus venting. First note the components, namely, : Reservoir with Filter, : Hydraulic ump,, : ilot Relief Valve, : Solenoid activated Four-way irectional valve. Venting Mode In Figure 28.2, both solenoids a and b of the directional valve are de-energized. he opencenter spool is centered by the valve springs, and the vent port on the relief valve is opened to tank. herefore, the pump flow opens to tank at a very low pressure. Version 2 II, Kharagpur 4

a b o System M Fig. 28.2 Venting Mode Intermediate Maximum Operating ressure In Figure 28.3, the left-hand solenoid a of the directional valve is energized. he valve spool is shifted to the leftmost position and connects the relief valve vent port to the remote control valve. ump flow is now diverted to tank when the pressure setting of the remote valve is reached. a b o System M Fig. 28.3 Operating Mode with Intermediate Maximum Operating ressure Version 2 II, Kharagpur 5

High Maximum ressure In Figure 28.4, the right solenoid b of the directional valve is energized. he spool now shifts right to connect the relief valve vent port to a plugged port in the directional valve. he relief valve now functions at the setting of its integral pilot stage. a b o System M oints to onder: 2 Fig. 28.4 Operating Mode with High Maximum Operating ressure. Why are lines connecting to and to marked in dashed lines?. an you briefly describe a scheme to automate the above system such that whenever, in the intermediate pressure mode, pressure setting is exceeded, the system would automatically switch to the low pressure mode? ase Study III: Reciprocating ylinder with utomatic Venting at nd of ycle reciprocating cylinder drive is a very common hydraulic system. In systems where it is not necessary to hold pressure at the end of a cycle, it is desirable to unload the pump by automatically venting the relief valve, to save energy. Figures 28.5-28.8 show such a system. he system components are : : Reservoir with Filter, : Hydraulic pump,, : heck valve, : ilot operated relief valve, F : wo-position electro-hydraulic pilot operated Four-way irectional valve, G : am operated pilot valve, H : ouble acting Single rod ylinder, I : Limit Switch. Version 2 II, Kharagpur 6

xtension Stroke onsider the beginning of the machine cycle when the solenoid of the spring offset directional valve F is energized. ump output is connected to the cap end of the cylinder. he vent line drawn from the directional valve output connected to the cap end of the cylinder is blocked at the cam-operated pilot valve G. hus, vent port of the relief valve is blocked, and the cylinder moves under full pump pressure applied to the cap end. H G F b Retraction Stroke Fig. 28.5 xtension Stroke t the extreme end of the extension stroke, the limit switch is made on by the cylinder rod to break the solenoid circuit for the directional valve F. he directional valve now shifts to its right position and the pump gets connected to the rod end of the cylinder which now retracts. Note that the relief valve vent connection is still blocked. utomatic Venting at nd of Retraction Stroke t the extreme end of the retraction stroke, the cam on the cylinder is operated by the rod Version 2 II, Kharagpur 7

H G F R Fig. 28.6 Retraction Stroke to shift valve G. he relief valve vent port is thus connected, through and G, to the line from the cap end of the cylinder, and to tank through the F and the inline check valve. his vents the relief valve and unloads the pump. ush utton Start of ycle If another cycle of reciprocating motion is desired, a start button connected to the solenoid circuit is depressed to energize the solenoid, and, in turn, the directional valve shifts to direct pump output into the cap end of the cylinder. his causes the check valve in the vent line to close. ressure again builds up and the cylinder starts extending. his releases the cam, which, under spring action, shifts and the vent port of is again blocked at G. hus the cycle repeats. oints to onder: 3. How does the solenoid get energized if the limit switch is made?. Is the speed of the cylinder going to be equal during extension and retraction? If not, then what decides the speeds? Version 2 II, Kharagpur 8

F R H G 1 2 Fig. 28.7 utomatic Venting at nd of Retraction Stroke F R H G 1 2 Fig. 28.8 ush utton Start of ycle Version 2 II, Kharagpur 9

ase Study IV: Regenerative Reciprocating ircuit onventional reciprocating circuits use a four-way directional valve connected directly to a cylinder. In a regenerative reciprocating circuit, oil from the rod end of the cylinder is directed into the cap end to increase speed, without requiring to increase pump flow. Such a circuit is shown below in Figures 28.9-28.10. he circuit components are : : Hydraulic ump, : Relief valve, : Four-way two position solenoid operated valve, : ouble-acting Single-rod ylinder. he operation of the regenerative circuit is shown in Figures 28.9-28.10. Regenerative dvance In Figure 28.9, the port on the directional valve, which conventionally connects to the cylinder, is plugged and the rod end of the cylinder is connected directly to the pressure line. With the valve shifted to the left most position, the port is connect to the cap end of the cylinder. If the ratio of cap end area to rod end annular area in the cylinder is 2:1, the pressure being the same at both end, the force at the cap end is double that at the rod end. here is therefore a net force on the cylinder to move the load. Similarly, at any speed of the cylinder, the flow into the cap end would be double that of the rod end. However, in this connection, the flow out of the rod end joins pump delivery to increase the cylinder speed. hus only half of the flow into the cap end is actually supplied by the pump. However, the pressure during advance will be double the pressure required for a conventional arrangement for the same force requirement. his is because the same pressure in the rod end, effective over half the cap end area, opposes the cylinder s advance. In the reverse condition shown in Figure 28.10, flow from the pump directly enters the rod end of the cylinder through two parallel paths, one through the directional valve and the other directly. xhaust flow from the cap end returns to the tank conventionally through the directional valve. Note that, in contrast to the conventional case, the force on the cylinder as well as the pump flow remains unchanged during extension and retraction. hus, the speed of the piston during both advancement and retraction remain same. a b Fig. 28.9 Regenerative xtension Stroke a b Fig. 28.10 Regenerative Retraction Stroke Version 2 II, Kharagpur 10

oints to onder: 4. xplain all parts of the symbol of the directional valve in Figures 28.9-28.10.. ompare, point by point a regenerative reciprocation circuit with a conventional one. ase Study V: Sequencing ircuits In many applications, it is necessary to perform operations in a definite order. Following is one of several such circuits. he components of the system are as follows. : Reservoir and Filter ; : Hydraulic ump ; : ; Relief valve : ; F 1, F 2, G : Relief valve with integral check valve ; H, J : ylinders ; I : heck Valve he sequence of operation realized by the circuit shown in Figure 28.11-28.14 is: Step xtend ylinder H Step xtend ylinder J while holding pressure on ylinder H Step Retract ylinder J Step Retract ylinder H F 1 J G H F 2 Fig. 28.11 ylinder H xtending Version 2 II, Kharagpur 11

Step ressing a pushbutton would start the cycle and shift the directional valve to the position shown in Fig 28.11. t first the fluid flows through the integral check valve in G into the cap end of H and returns freely through the check valve in F 2. he pump pressure is low during this period, only to the extent of pushing the load on H. Step Once H reaches its rod end, the pressure builds up and now the flow develops through F 1 into the cap end of J and out through the rod end to go back directly to tank through F 2, and. Note that a pressure equal to the setting of the valve F 1 is maintained on H. When J is fully extended, pressure increases further and is limited by the setting of, providing overload protection to. F 1 J G H F 2 Step Fig. 28.12 ylinder J xtending Similarly, when the other solenoid of is energized, the directional valve shifts to the other position, as shown in Fig. 28.13. Now, pump delivery is directed through, and F 2, into the rod end of J. s before, the flow out of the cap end of J flows to tank through F 1, and. Step is illustrated in Fig. 28.13. Version 2 II, Kharagpur 12

Step On completion of Step, the pressure increases again, and the flow is directed through F 2 to the rod end of H and out through the cap end to flow into the tank through the valve G at its pressure setting and then freely to tank through F 1, and. Note that F 2 maintains a pressure equal to the setting of H at the rod end of J during the retraction of H. Note further that, while H is retracting, a back pressure is provided to it by G, to prevent rapid falling of the load during lowering, under gravity. In the above circuit, sequencing is achieved by grading the pressure settings of the relief valves. Note that sequencing can also be achieved electronically by L control of the solenoids of separate directional valves driving H and J. F 1 J G H F 2 Fig. 28.13 ylinder J Retracting Version 2 II, Kharagpur 13

F 1 J G H F 2 Fig. 28.14 ylinder H Retracting Lesson Summary In this lesson we have presented industrial hydraulic circuits for following applications:. Unloading of pumps based on relief valve and check valve to avoid overloading.. Selection of system operating pressure from two values based on settings of relief valves and their selection with a directional valve.. xtension-retraction ircuit for one cylinder with automatic unloading of pump at the end of cycle. xtension-retraction ircuit for one cylinder with regenerative feedback. Sequenced extension-retraction circuit for two cylinders. Version 2 II, Kharagpur 14

nswers, Remarks and Hints to oints to onder oints to onder: 1. an you imagine what would happen, if the check valve was not present? ns: hen, if the setting of the relief valve is reached, both pumps would have unloaded.. How would you modify the system if you wanted to unload pump instead of pump? ns: hen, a check valve is to be placed between pump and the system, after the relief valve. he relief valve after would be removed. Finally, the setting of would have to be set lower than that of. oints to onder: 2. Why are lines connecting to and to marked in dashed lines? ns: ecause these are pilot lines for the relief valve.. an you briefly describe a scheme to automate the above system such that whenever, in the intermediate pressure mode, pressure setting is exceeded, the system would automatically switch to the low pressure mode? ns: One of the ways is to devise an automated logic for exciting the solenoids of the directional valve. he above feature can be implemented by using a pressure switch which would be made if the pressure setting is exceeded. his pressure switcvh contacts can then be incorporated into a relay circuit or a L program that would drive the solenoid of the directional valve corresponding to high pressure. oints to onder: 3. How does the solenoid get energized if the limit switch is made? ns: he limit switch contacts can be incorporated into a relay circuit or a L program that would drive the solenoid of the directional valve.. Is the speed of the cylinder going to be equal during extension and retraction? If not, then what decides the speeds? ns: he speed of the cylinder is going to be different during extension and retraction. Note that the cross-sectional areas of the two sides of the piston are different because of the single-rod configuration. uring extension, the pump pressure acts on the cap end of the cap end of the cylinder which has higher area than the rod end. herefore, the net force acting on the piston during extension is more than that during retraction. he speeds reached during these strokes depend on the load that exists during these Version 2 II, Kharagpur 15

strokes. hus, to summarize, the speeds depend on the loads as well as the areas of the rod and the cap ends f the cylinder. oints to onder: 4. xplain all parts of the symbol of the directional valve in Figures 28.9-28.10. ns: he directional valve has two positions and is a four-way valve with the pump port and the tank port on one side and the two load side ports and on the other. he valve is not spring loaded and therefore requires two solenoids for moving it to the two positions. he solenoid moves a hydraulic pilot valve spool, which, in turn, moves the main valve spool. he valve is called detented because it has a mechanism that locks the piston into the position it moves into and holds it there. In the circuit in which the valve is used, in the left position, one port of the valve is plugged, as marked by a cross.. ompare, point by point a regenerative reciprocation circuit with a conventional one. ns: In a regenerative circuit higher cylinder speed can be reached with a lower pump flow rate. However, for a given force requireent to move the load, higher pup pressures are needed, since there exists a back pressure at the rod end of the piston, unlike in a conventional reciprocation circuit. In the retraction stroke, however, regeneration is not possible. In both cases, regenerative and conventional, cylinder speeds during retraction and extension are different in general. Or the regenerative case, however, they may be made equal with area ration of 2:1 of the cap and the rod ends of the piston. Version 2 II, Kharagpur 16