PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

Similar documents
UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

CRP. Commissioning damper, Ductwork Leakage Class 0

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

TBV - Terminal Unit. Halton TBV. Terminal Unit

VOLUME CONTROL / REGULATING DAMPERS

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

Mechanical mixing box MBM

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

IrisControlDamper. For Adjustment and Measuring of Airflow.

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

ACCESSORIES FOR DUCT FANS

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Actionair Control and Shut Off Dampers

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

Variable Air Volume Dampers

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Mounting Installation Instructions LM, NM, AM, GM

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

ceiling swirl diffuser DQJ

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

VAV TERMINAL BOXES TYPE: BA BT

MULTI-LEAF & SHUT-OFF DAMPERS Product Catalogue

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Particle Filter Box Model FKF

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Damper actuators with spring return

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

BOX - Airflow management unit BOX. Airflow management unit. Solution. Options & Accessories

CAV controllers Type RN

CFSD Series. Product Description

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Particle Filter Box FKU

Blade Features. AirShield Control and Shut Off Dampers. AirShield

Mounting Installation Instructions NKQ, GK

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

BLBd

VARYCONTROL VAV Dual Duct Terminal Boxes

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Long Throw Nozzle WDA

PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised

VAV controller. TROX Auranor Norge AS. Telephone Fax

Volume Flow Limiters Type VFL

products 22 º C Ventilation Air Conditioning Refrigeration Inside PROVIDED BY HEINEN & HOPMAN

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

CCS Zone/Bypass Damper Assembly

Technical information

TRANS-Quick System. ALNOR ventilation systems. Download Wentyle Download AlnorCAM Order via B2B platform

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Table of Contents PAGE General Mounting Standard Reversible Clamp Linear Rotary Retrofit Brackets...275

ULA - Valve. Halton ULA. Valve

Fitting Instructions DucoGrille Close /03/2018

Zest Iris Duct Dampers

AF Series Spring Return Direct Coupled Actuator

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Flowmeter MDW 500. description. 230 VAC (50/60 Hz), 24 VAC/VDC with polarity reversal protection, 110VAC(60Hz) on request

3. Dimensions and weights Placement and installation Pressure lost Material... 14

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Ceiling swirl diffusers

Technical documentation

DAC - Conical Diffuser. Halton DAC. Conical diffuser

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

TECHNICAL BULLETIN PRODUCT INQUIRY

Slot diffusers, Round duct diffusers. IMP Klima

ESAS Smoke control damper

Regulation and shut-off damper SPB and SPC

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

ACCUVALVE MODEL AVT6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVT6000 AVT6 - - DWG. NO: REVISION: REV. DATE:

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

USS - External Louvre. Halton USS. External Louvre

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Transcription:

Halton PTS Single-Blade Damper Shut-off, adjustment, balancing or control damper Casing leakage classification: EN 1751, Class C Casing and damper blade made of galvanised steel Tightness classification of shut-off damper: EN 1751, Class 4 Product models and Accessories Shut-off, adjustment, balancing or control damper Adjustment, balancing or control damper Adjustment, balancing or control damper with perforated blade Several actuator options MATERIAL PART MATERIAL NOTE Casing Blade and shaft Operating mechanism Blade gasket Duct gaskets Actuator platform Galvanised steel Galvanised steel Galvanised steel EPDM rubber 1C-polyurethane hybrid Galvanised steel Used only in PTS/A model QUICK SELECTION D qmin qmax [mm] [l/s] [m 3 /h] [l/s] [m 3 /h] 100 8 28 47 170 125 12 44 74 265 160 20 72 121 434 200 31 113 188 679 250 49 177 295 1060 315 78 281 468 1683 400 126 452 754 2714 500 196 707 1178 4241 qmin 1 m/s duct velocity qmax 6 m/s duct velocity - recommended maximum airflow for comfort applications 76

DIMENSIONS NS L L1 L2 ØD 100 145 70 36 99 125 145 70 36 124 160 145 70 36 159 200 145 70 36 199 250 145 70 36 249 315 145 70 36 314 400 245 175 35 399 500 245 175 35 499 Actuator platform, low (ML) ØD 65 L2 L1 L Actuator platform, high (MH) 24.5 45.2 57.5 45.2 70 70 4.7 160 4.7 160 25 45.2 25 45.2 Product models and Accessories There are three different product models, for different purposes: Shut-off, adjustment, balancing or control damper, PTS/A Tightness classification: EN 1751, Class 4 Adjustment, balancing or control damper, PTS/B Adjustment, balancing or control damper with perforated blade, PTS/C Minimum torque 4 Nm 10 Nm PTS/A 100...250 x PTS/A 315...500 x PTS/B 100...500 x PTS/C 100...500 x Actuator options Standard actuators Belimo LM24A / LM230A / LM24A-SR (5 Nm), NM24A / NM230A / NM24A-SR (10 Nm) and LF24 / LF230 (4 Nm) For technical data for available actuators, consult the list below. After sales installation of the actuator Actuator installation on the site is possible with the help of an actuator bed and extension shaft. This enables installation of a universal actuator type. The actuator bed selected can be of standard type when the ductwork is not insulated or of high type if the ductwork is insulated. Manual operation Handle for manual operation with blade position locking. 77

PTS/A with actuator (B4) Actuator IL / IH PTS Electrical actuator: specific data If other actuator types are required, consult Halton in order to specify the type and manufacturer. CODE NAME MANUFACTURER TORQUE Nm POWER SUPPLY CONTROL TYPE POWER CONSUMPTION B1 LM24A Belimo 5 24 VAC/VDC On-off, 2-wire 3 VA / 2 W B2 LM230A Belimo 5 230 VAC On-off, 2-wire 12 VA / 1 W B3 LM24A-SR Belimo 5 24 VAC/VDC Modulating 0 10 VDC 4 VA / 2 W B4 NM24A Belimo 10 24 VAC/VDC On-off, 2-wire 3.5 VA / 2 W B5 NM230A Belimo 10 230 VAC On-off, 2-wire 18 VA / 2 W B6 NM24A-SR Belimo 10 24 VAC Modulating 0 10 VDC B7 LF24 Belimo 4 24 VAC On-off, spring return B8 LF230 Belimo 4 230 VAC On-off, spring return 3 VA / 1.5 W 7 VA / 5 W 8 VA / 5 W 78

PTS/A PTS/B Function The PTS unit can operate as a shut-off, control or adjustment damper depending on the product model. This damper is available for circular standard duct sizes 100 mm to 500 mm. Damper position is visually indicated below the operating mechanism. The PTS/A is a shut-off damper of leakage class 4 according to the EN 1751 standard. It includes rubber gaskets to ensure low leakage flow when the damper is in closed position. The PTS/A is available with a handle for manual operation or with an electric actuator for on-off control or for modulating control using a 0...10 VDC control signal. PTS/C The PTS/C is an airflow adjustment damper. The damper blade is a perforated blade that is acoustically and operationally designed for balancing of airflow rates. The PTS/B can be used for airflow control or adjustment of airflow rates in the ductwork. It includes a steel blade without gasket. The PTS/B is available with a handle for manual operation or with an electric actuator for on-off control or for modulating control using a 0 10 VDC control signal. The electric actuator is normally installed in the factory on the actuator platform with screws. On-site actuator installation is possible with the help of an actuator installation kit. The actuator installation kit, available as an accessory, includes an actuator platform and extension shaft for universal actuator fixing. The actuator platform and actuator can be installed easily using standard hand tools. 79

Installation Fasten the damper to the ductwork with, e.g., rivets. Ensure that the rivets do not prevent the operation of the damper. The position of each rivet must be at least 10 mm from the duct end. External duct gaskets ensure an airtight joint when the damper has been mechanically fastened to the duct with rivets or screws. The electric actuator (where applicable) is to be connected to the power supply and control signal wires according to the wiring diagram. Examples of connections for the standard actuators are shown in a separate diagram. The electric actuator can also be installed, when necessary, in an on-site procedure with the help of an actuator platform and universal shaft fitting, available as an accessory: Remove the operating mechanism (1) by opening the locking screw. Assemble the actuator platform in the location of the operation mechanism (2) and ensure its stability mechanically by bending the legs of the actuator platform with a hand tool. The universal actuator fitting enables connection of most actuator types to the shaft (3) (4). Wire connections are to be performed according to the instruction for the actuator installed. Electric wire connections Belimo ~ 24 VAC, 24 VDC 230 VAC ~ 24 VAC, 24 VDC 0-10 VDC 2-10 VDC 1 2 3 5 1 2 3 5 ~ Y1 U ~ Y1 U LM...A NM...A LM24A-SR NM24A-SR LF24-SR SM24A-SR ~ 24 VAC, 24 VDC 0-10 VDC 2-10 VDC S1 S2 S3 1 2 3 5 ~ Y1 U M AF24-SR LF AF 80

Pressure drop and sound data PTS/A-100 PTS/A-125 PTS/A-160 PTS/A-200 81

Pressure drop and sound data PTS/A-250 PTS/A-315 PTS/A-400 PTS/A-500 82

Pressure drop and sound data PTS/B-100 PTS/B-125 PTS/B-160 PTS/B-200 83

Pressure drop and sound data PTS/B-250 PTS/B-315 PTS/B-400 PTS/B-500 84

Pressure drop and sound data PTS/C-100 PTS/C-125 PTS/C-160 PTS/C-200 85

Pressure drop and sound data PTS/C-250 PTS/C-315 PTS/C-400 PTS/C-500 86

Suggested specifications The casing and circular (perforated) blade of the shutoff / adjustment / control damper shall be made of galvanised steel. The shut-off damper shall meet EN 1751, Class 4 tightness requirements. External rubber gaskets on the spigot shall provide an airtight connection to circular ductwork. Product code PTS/S-D S = Version A Damper with blade gasket B Damper without blade gasket C Damper with perforated blade D = Diameter of duct connection 100, 125, 160, 200, 250, 315, 400, 500 Specifics and accessories MA = Material CS Steel MO = Actuator type NA Manual=default B1 LM24A, 5 Nm, 24 VAC/VDC, on-off B2 LM230A, 5 Nm, 230 VAC, on-off B3 LM24A-SR, 5 Nm, 24 VAC/VDC, modulating B4 NM24A, 10 Nm, 24 VAC/VDC, on-off B5 NM230A, 10 Nm, 230 VAC, on-off B6 NM24A-SR, 10 Nm, 24 VAC/VDC, modulating B7 LF24, 4 Nm, 24 VAC/VDC, on-off, spring return B8 LF230, 4 Nm, 230 VAC, on-off, spring return AC = Accessories BA Handle for manual operation ML Actuator platform, low MH Actuator platform, high IL Installation kit for actuator, low IH Installation kit for actuator, high IJ Actuator platform; low for LF actuator Code example PTS/A-100, MA=CS,MO=NA 87