PERCHLORIC ACID FUME HOOD H25. Fume Hoods. 48"- 60"- 72"- 96" long

Similar documents
Supreme Air Series VENTURI FUME HOOD. Operation Maintenance Technical Manual KEWAUNEE

General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood

Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME

LABORATORY FUME HOODS OF 5

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section )

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com

F. VAV hoods shall have a restricted bypass plate.

Installation Instructions

Labconco 48, 60, and 72 Hoods

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

V05 General Purpose Bench Fume Hood

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

FUME HOOD SELECTION GUIDE

Head Terminal Repair Parts. Hopper Repair Parts

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION

CORPORATION DURALAB CORPORA

DOOR KIT P/N , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Installation Instructions

INSTALLATION INSTRUCTIONS

ASSEMBLY & INSTALLATION INSTRUCTIONS

Supreme Air Fume Hood Option Availability

Owner smanual. Banks Ram-Air Super-Scoop Chevy/GMC Pickups. with Installation Instructions

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Requires Ductwork and Blower

How to Use a Chemical Fume Hood Safely

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Size Grade Torque 9/ ft/lbs. 5/ ft/lbs. 3/ ft/lbs. 7/ ft/lbs ft/lbs.

Body Preparation. Stretching the Frame. Stretch Kit CHAPTER 4

Assembly & Installation Instructions

Fume Hood Operation & Maintenance Manual

Supreme Air Venturi KEWAUNEE. Laboratory Fume Hoods. encouraging new discovery...worldwide

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features

Bedcolab Vanguard Laboratory Fume Hoods

INSTALLATION INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

Fume Hoods Overview OVERVIEW

RH INSTALLATION INSTRUCTIONS 2

GrilleGuy.com, LLC. Installation Instructions and Care Guide : Toyota Tacoma Grille UPPER GRILLE

UTV Universal Stronghold Auto- Latch Double Boot Mount

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Pre-Wired and Pre-Piped

Wildcat System Instructions

TS Series TS Series

Ram 1500 Crew Cab A Ram 2500/3500 Crew Cab A

LIFT-507 BMF Lift Kit E-Z-Go RXV Gas or Electric Installation Instructions

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

FUME HOOD. Installation and Operations Manual

th Avenue Spring Lake, MI Ph:

Z1 Motorsports 350Z / G35 Oil Cooler Kit Installation Manual

Model 854/856. Operating and Assembly Manual. Midwest Equipment Manufacturing, Inc Serum Plant Road Thorntown, IN 46071

! CAUTION! Before You Start. General Information. Assembly Instructions. Small Seeds Box Attachment Option. Assembly Instructions

Supreme Air Venturi Laboratory Fume Hood Catalog. ehpricesales.com

Thermo Scientific Hamilton Air Flow Products. Table of Contents

INSTALLATION INSTRUCTIONS SEMI Hidden Kit Part Number: Application: Toyota Tacoma

CATALOG OF REPLACEMENT PARTS

Instruction Sheet. Kit Numbers: , , & CRANK PULLEY KIT DISASSEMBLY. Package Contents

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

Z1 Motorsports 370Z/G37 Oil Cooler Kit Installation Manual

Installation, Operation & Maintenance

Other HEMCO Products. HEMCOR Lab Planning Solutions. Installation, Operation, Maintenance Manual UniFlow LE FM Floor Mounted Fume Hood

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

User s Manual. LabShield. Laboratory Fume Hoods. Air Foil By-Pass Models: 6714, 6716, ADA Models: 8796, 8798, Demonstration Hood 6725G

Other HEMCO Products. HEMCOR Lab Planning Solutions

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

INSTALLATION INSTRUCTIONS

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS

Removable Applied Panel Mounting System

The engine cowling installation and firewall should be inspected and modified as specified in this Service Bulletin.

EXTERIOR PAINTED KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev 01 05/16 Page 1 of 5. Slingshot

A CAB KIT (Shown with GLASS DOORS KIT A-11859)

CENTRAL VACUUM SYSTEMS

MC2500. Installation and Operation Manual

~-- (I, G & H 4.9L W/O AC BELT DRIVE, SLC REV. D. c u ~~~~ SERIES FORD 6 CYL 300 CID PECULIAR HYDRAULICS HPS458Ò

WATER PUMP INSTALLATION INSTRUCTIONS WEIAND WATER PUMPS ACTION PLUS & TEAM G APPLICATIONS FOR SMALL BLOCK & BIG BLOCK CHEVROLETS

AUDIO KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

INSTALLATION INSTRUCTIONS AND PARTS LIST

69-74 VW Beetle IRS Rear Kit Part No

Combine Cover Manual

ITEM PART NO. DESCRIPTION QTY BODY - SNORKEL (SS156HF) ½" AIR RAM ASSEMBLY BRACKET - UPPER MOUNTING 1

Installation Instructions

COLD AIR INTAKE INSTALLATION INSTRUCTIONS

Siderolling Tarp Systems Under 9 6 Wide

CAUTION. INSTALLATION INSTRUCTIONS Part Number Hidden Winch Kit with special XD 9000 Short Drum Winch For Ford F-150 Truck

Thermo Scientific Hamilton Horizon Fume Hoods. Operation, Maintenance and Installation Instructions

SECTION 1 SEAT BACK SUPPORT INSTALLATION

Hiniker Company th St. P.O. BOX 3407 Mankato, MN VEHICLE INSTALLATION INSTRUCTIONS FORD 4x4: SUPER DUTY F

TAILGATE SPREADER INSTALLATION INSTRUCTIONS

~~ " '" :.~ ~. -~ :: ø U) 6Â~ l\ '---_._ , " ~ -1rr-~.." fj PECULIAR HYDRAULICS. " f ',~, ...

Assembly Instructions

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

Installation Instructions for: TOYOTA 3.4L SUPERCHARGER SYSTEM

Ford F-150 Billet Grilles Upper Replacement

INSTALLATION INSTRUCTIONS

EXHIBIT HEAD & DRIVE PULLEY LAGGING

Transcription:

Supreme Air PERCHLORIC ACID FUME HOOD with Vertical Rising Sash H25 S T Y L E Fume Hoods 48"- 60"- 72"- 96" long Publication No. IIH25-SA 11/05 Part Number: IMAN-H25

Supreme Air Bench Hood Perchloric Acid Fume Hood w/vertical Rising Sash Figure 1 SASH CABLE SASH ADJUSTMENT (loosen screws to adjust) 1/4" -20 x 3/4" R.H. Bolt w/nut & Washers FRAMELESS SASH WEIGHT BOX Detail 2A CABLE CONNECTOR Figure 2 Detail 2B IIH25-SA 11/05-2

Packing List Installation Instructions Supreme Air Bench Hood Perchloric Acid Fume Hood w/vertical Rising Sash On Pallet Fume Hood Sash Weight Box Hardware Package Hardware Package (10) Nylon Screw Caps (EXTRAS) (10) 3/4" Plastic Plug Buttons (2 EXTRAS) (3) Deflectors Clamps Preparation 1. Place, level, and install the Base Unit Assembly that will support the Fume Hood. Base Unit Assembly must be level. Shim beneath as needed. 2. Uncrate Fume Hood taking care to sort and inventory all parts. 3. Remove End Panels from Fume Hood and remove screws holding Fume Hood and Weight Box to pallet. (Save End Panel screws to reattach End Panel later.) 4. Remove all packing from Fume Hood and any tape holding parts in place for shipping. Installation Fume Hood is packed fully assembled except for Weight Box. The Top Front Panel and Lower Deflector Vane may be removed to fit through narrow doorways and/or for easier access. Generally electrical fixtures and plumbing fittings are shipped installed, but may be shipped loose depending on job requirements. Fittings may also be pre-wired and/or pre-piped. Fixtures are not shown on assembly diagram as quantities and locations vary to meet individual requirements. 5. Check that Sash Cables are properly routed over front pulleys, around rear pulleys, and through the Sash Adjustment pulleys. (see Figure 2) 6. Attach Weight Box to cables using one (1) 1/4" -20 x 3/4" R.H. Bolt, Nylock Nut, and two (2) Flat Washers (bolt, nut, and washer shipped attached to cable ends) 7. Loosen Sash Adjustment pulley bolts and slide pulleys as needed to level sash. Re-tighten when adjusted.! CAUTION Handle Frameless Sash with care - Laminated Safety Glass will crack if abused. 8. Using as many workers as needed, lift assembled Fume Hood and place on leveled Base Unit Assembly. Make sure hood is centered side-to-side on Base Unit Assembly and overhangs the front by 1 1 /2".! CAUTION If hood is pushed too far back, Sash Weights will not operate properly and End Panels will not fit. 9. Attach the spacer tabs on the bottom of the Lower Deflector Vane to the Worksurface using the Deflector Clamps. 10. Coordinate connections of service fittings, electrical fixtures, and ductwork with the respective trades (i.e. mechanical, electrical, HVAC). After connections are complete, replace the exterior End Panels. Cover screw holes in End Panels with 3/4" Plastic Plug Buttons. 11. Check Sash again for level and smooth movement. Adjust as needed. To level, loosen pulley screws on Sash Adjustment mechanism and slide pulleys as necessary. (see Detail 2A) To adjust Sash side-to-side, loosen screws on back of Sash Handle and slide the Cable Connectors as needed. (see Detail 2B)! CAUTION When adjusting side-to-side, make sure sash edges clear the front pulleys. 12. Inspect the complete installation, remove any dust, dirt, or other debris. Check all moving parts for proper operation, and adjust or lubricate as necessary. IIH25-SA 11/05-3

Base Unit Assembly for Bench Type Fume Hoods REAR FILLER (optional- install as required) KEMSTRUTS (install as required) Screws (4) required one each corner FACE FILLER (optional- install as required) Detail 1 Fume Hood Base Cabinet Location BASE UNITS PLUG BUTTONS ADJUSTMENT BOLT (accessible thru cabinet bottom with straight blade screw driver) Detail 2S Steel base cabinets are leveled using the adjustment bolts located in the cabinet base. Preparation 1. Locate and mark hood and base cabinet locations making sure area is clear of obstructions and debris. Be sure all conduit, duct work and service lines have been run and are ready for final connections. Kemstruts and other pipe or worksurface supports should be installed before the base cabinets are moved into place. 2. Locate the high point of the floor within the area that the base cabinets will be installed. Installation 3. Starting with the base cabinet on the highest point on the floor, move the first cabinet into location. Make sure the back of the cabinet is located 8 from the rear wall, as shown in Detail 1 above, and in proper relationship to adjacent walls or equipment as shown on job drawings and floor plans. 4. Using a four foot carpenters level, level the cabinet; side-to-side, front-to-back, and diagonally. (see Detail 2S to the left for leveling methods) Blocks or cleats may be used to fasten cabinets to floor or walls to insure cabinets don t move during installation. 5. Move the next cabinet into position and clamp it to the first cabinet, making sure that the cabinet faces and tops are flush. 6. Level the cabinet, as in step 4. 7. Using four (4) #8 x 1/2 Truss Head Sheet Metal screws, fasten the two cabinets together at all four corners of the end panels. (pilot holes must be drilled in the steel cabinets before driving screws) 8. Complete hood installation and all mechanical connections before installing any required fillers or scribes. It is recommended that the polyethylene liner be removed from Acid Storage cabinets during installation to allow fastening to adjacent cabinets and ease plumbing connections. Be sure to replace when installation is complete. IIH25-SA 11/05-4

Supreme Air Bench Hood Perchloric Acid Fume Hood w/vertical Rising Sash NOTES: IIH25-SA 11/05-5

H25 Fume Hood - Parts Listing PRT QTY DESCRIPTION 39 1 SASH STOP, SIDE PANEL MOUNT 38 1 SASH STOP, BACK OF HANDLE 37 8 3/4" DIA. HOLE PLUG BUTTONS 36 1 FRONT LOAD COLD WATER 35 1 WASHDOWN KIT 34 1 SASH WEIGHT ASSEMBLY 33 2 DUPLEX RECEPTACLE 32 1 LIGHT SWITCH 31 1 FACE PLATE MOUNTING STRAP 30 1 BLANK FACE PLATE, ST/STEEL 29 1 RIGHT REAR CABLE RETAINER 28 1 LEFT REAR CABLE RETAINER 27 1 BYPASS BLOCK SUPPORT ANGLE 26 1 FUME RETAINER 25 2 VAPOR PROOF LIGHT 24 2 END PANEL 23 1 FRONT PANEL ASSEMBLY 22 1 SASH ADJUSTMENT PLATE 21 1 SASH ADJUSTMENT BRACKET 20 8 2" DIA. PULLEY 19 1 RIGHT REAR PULLEY BRACKET 18 1 LEFT REAR PULLEY BRACKET 17 2 FRONT PULLEY BRACKET 16 1 SASH ASSEMBLY 15 1 DEFLECTOR VANE WELDMENT 14 1 RIGHT FACIA 13 1 LEFT FACIA 12 2 SASH TRACK ASSEMBLY 11 1 BYPASS BLOCK OFF PANEL 10 2 BYPASS BLOCK PANEL ANGLE 9 1 BYPASS PANEL 8 1 LOWER REMOVABLE BAFFLE 7 1 UPPER REMOVABLE BAFFLE 6 3 CENTER WORKTOP REINFORCEMENT 5 1 FRONT WORKTOP REINFORCEMENT 4 1 PERCH. WRAPAROUND WELDMENT 3 1 TOP BACK LINER ANGLE 2 1 BOTTOM BACK LINER ANGLE 1 2 END FRAME WELDMENT IIH25-SA 11/05-6