SWITCHES SWITCHES. Control Switches SWITCHES. Pressure Specifications Chart , 528

Similar documents
SWITCHES. MISCELLANEOUS Air Control Switches Air Cylinders Louvers and Diffusers Switch Control Knobs

SWITCHES SWITCHES SWITCHES. AIR, CYCLING, CUT-OFF, SENSORS, TEMPERATURE, and TRANSDUCERS Miscellaneous Specifications Chart

RELAYS, RESISTORS, &SWITCHES (11- )

Section V: Illustrated

Controls. Electrical & Refrigerant 71R SERIES

Controls. Electrical & Refrigerant 71R SERIES. Did You Know The EXPANSION VALVE

71R SERIES. Controls. Electrical & Refrigerant

Controls. Electrical & Refrigerant 71R SERIES. Did You Know. Service Tip 71R SERIES

Controls. Electrical & Refrigerant 71R SERIES

Receiver Driers. Accessories

Receiver Driers. Accessories

Receiver Driers. Accessories

Basic Information EVAPORATORS EVAPORATORS. EvaporatorS Illustrations Specifications...352

RoadChoice.com HVAC CATALOG

Section V: Table of Contents

Table of Contents Accumulators RECEIVER DRIERS

HEAVY DUTY HEATING & AIR CONDITIONING UNITS & ALL MAKES PARTS. ISSDistribution.com - Call (800)

CONDENSERS BASIC INFORMATION CONDENSERS. CONDENSER Specifications Chart Visual Illustrations Section MULTI-FLOW RETROFIT CONDENSERS...

HEATER CORES. Basic Information

Table of Contents. Basic Information (Cores)

13 HVAC. Application Table Blower Motors & Parts for Trucks, Trailers & Buses. Proven, reliable and always innovative.

YEAR MODEL APPLICATION O.E.M. # PART NO. 38,48,49,58,59,69

ELECTRICAL PARTS. 3 SPEED ROTARY LONG SHANK WITH NUT PART No: SPEED ROTARY WITH RESISTOR 24v. PART No: PART No:

SERVICE VALVES. Selecting the Correct Service Valves COMPRESSOR PARTS

HVAC Solutions. New refrigerant regulations you need to know. EVERYDAY DELIVERY TO: Eastern Iowa Western Illinois Southwest Wisconsin

A/C SALES and PRODUCT TRAINING

XV. Parts. Mobile Climate Control 303

V 40/30A. Heavy duty type, 12 amp, thread

R-4122 Sleeper Heater/ Air Conditioner Unit. R-2550 Heater/Air Conditioner Unit RED DOT UNITS HEATER-A/C RESCUE VEHICLES

78R SERIES. Hoses & Filters

SERVICE PARTS for MCC XCELSIOR SERIES T -367PL REV. 02/ Mobile Climate Control

On-Road OEM Applications

25 Off Use code: COUPON-RTACCOMP25 Valid March 1 31, Off Use code: COUPON-RTACCOND20 Valid March 1 31, 2019.

rotary & headlamp switches

SWITCHES & ELECTRICAL ASSEMBLIES

No-Idle Units. NITE Phoenix System NITE Plus System NITE Battery Specifications NITE Day Cab System Espar Systems...

R-8230 Underdash Heater/Air Conditioner Unit

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

push-pull, rotary & headlamp

& 76 CHEVROLET NOVA HEATER ONLY

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Third Generation NITE Phoenix

PITNEY BOWES Sure-Feed Engineering SURE JET MODEL SJVB - TUV. Parts Manual. SJVB-TUVparts 1

Identification Tag (cannot be used for ordering purposes) Part Number Label (identifies mfg. part number of complete assy.)

FREIGHTLINER

SERVICE & OWNER S MANUAL

SWITCHES & RESISTORS

R-6160 Rooftop Condenser (24,000 BTU) R-4500 Rooftop Condenser (45,000 BTU) RED DOT UNITS CONDENSERS. Crash/Fire/Rescue

Cartridge pressure switch Type CB

Product Data Sheet. Part Number: Gen 2 Back of Cab. Product Technical Specifications

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO

refrigeration SHAKE #15-77CMT ICE CREAM MACHINE ELECTRO FREEZE 21 SHAKE DISPENSE HEAD ASSEMBLY SHAKE BEATER SEAL ASSEMBLY 9

YEAR MODEL APPLICATION O.E.M. # PART NO SERIES All w/flange type motor, heavy duty, w/oe# C1...

R134a Compressors SD 5 10 HD SD 7 H 15 HD

Replacment Parts. Red Dot. Bus HVAC Parts SCHOOL AND TRANSIT BUSES

ELECTRICAL PRODUCTS. ISO/TS Registered

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

FACTORY AIR CONVERSION HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE

an ISO 9001: 2008 Registered Company CHEVELLE without FACTORY AIR REV C 8/27/14, CHEVELLE wo AC EVAP INSTR PG 1 OF 29

an ISO 9001:2008 Registered Company 1964 CHEVY IMPALA WITHOUT FACTORY AIR REV C 7/8/14, 1964 IMPALA wo AC EVAP INST PG 1 OF 25

ELECTRICAL TABLE OF CONTENTS

REPLACEMENT PARTS ILLUSTRATION

SWITCHES SECTION. Fuse Holders. Toggle Switches - Screw Terminals. Fuses. Toggle Switches - Blade Terminals. Terminal Block - Junction Box

75R SERIES BLISSFIELD (TECUMSEH), TCCI (YORK) COMPRESSOR CLUTCHES. CLUTCH SPECIFICATIONS Clutches are sorted by increasing size of Pulley Diameter [A]

1961 PASSENGER CAR PARTS CATALOG Page 24-1 GROUP 24 - AIR CONDITIONING

Engine and exhaust solutions.

cos-8e & cos-8eds combi ovens cnv-8e convection oven

Pontiac GTO with Factory Air Control Panel Conversion Kit (473167)

R-4500 Rooftop Condenser (45,000 BTU) R-6160 Rooftop Condenser (24,000 BTU) RED DOT UNITS

A/C-HEATER SYSTEM - AUTOMATIC

READ COMPLETELY BEFORE QUOTING REPOWER

DFG-50 GAS CONVECTION OVEN REPLACEMENT PARTS LIST

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

Camaro without Factory Air

ELECTRICAL SYSTEM RP-7

Idle Free Systems, Inc. Reference Guide System Component Information

R-4500 Rooftop Condenser (45,000 BTU) R-6160 Rooftop Condenser (24,000 BTU) RED DOT UNITS CONDENSERS

an ISO 9001:2008 Registered Company CORVETTE REV B 7/3/14, COVETTE EVAP INST PG 1 OF 24

REPLACEMENT PARTS FOR: CHEVROLET/GMC FORD/STERLING FREIGHTLINER HINO INTERNATIONAL ISUZU

CHAPTER 4 PARTS. 1234av This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation.

Item Part No Description Item Part No Description Screw, 6-32 X 3/8" Column, LD * Wrapper, Models LP, S Washer, #8

A/C SYSTEM SPECIFICATIONS

BLOWER MOTORS HA TruckAirParts

CHEV PICK-UP

DESCRIPTION AND OPERATION

Accumulators -See Filter Driers BLOWER MOTORS

OPERATOR S MANUAL HWH COMPUTER-CONTROLLED 2000 SERIES LEVELING SYSTEM. FEATURING: Single Step Touch Panel Control Air Leveling

CHEV PICK-UP

ActionRental.com

Description Jacobs # RVI # Description RVI # Jacobs #

P70, P72, and P170 Controls for Low Pressure Applications

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS

an ISO 9001: 2008 Registered Company GEN IV ROTARY CONTROL PANEL KIT REV D 4/14/15, INST GEN IV ROTARY CONTROL PANEL KIT PG 1 OF 13

MP ES/ED. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

an ISO 9001: 2015 Registered Company PONTIAC GTO

A/C-HEATER SYSTEM - AUTOMATIC

Cutlass without Factory Air

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #

EFFICIENT SLEEPER COMFORT. Volvo s Battery-powered Parking Cooler Option

Transcription:

Air, Cycling, Cut-Off, SENSORS, temperature, and TRANSDUCERS Pressure Specifications Chart... 511, 528 Air operated Switches... 510 Air Sensing Switches... 545 Apads switches... 551 Binary/Trinary... 537, 538 MISCELLANEOUS Air Control Switches... 510 Air Cylinders... 510 Louvers and Diffusers... 525 Switch Control Knobs... 524 PRESSURE HIGH - LOW PRESSURES Pressure Switch Identification... 529 Pressure Specifications... 527 Visual Numerical Identification... 530 blower - Rocker, Rotary, Toggle Specifications... 512 Visual Numerical Identification... 513 Circuit Breakers... 517 Control Switches... 517 (Actuators, CTC Components, Push Button) index switches... 547 KNOBS - Switch Controls... 524 LOUVERS and DIFFUSERS... 525 Micro and Clutch Switches... 519 Relays... 519 Resistors... 522 Solenoid Valves and DIAGRAM... 545 SWITCH PLATES... 516 Thermister Components... 539 THERMOSTATIC Switches... 540 toggle switches... 513 transducers... 536 WIRING COMPONENTS... 542 (Connectors, Harnesses, Pigtails) 509

Listed in ascending order by part number. Air Operated Switches 2009 Air Cylinder Action...Double Diameter...0.89 Length...4.69 Fitting...1/8 Nylon Hose Push-In 2010 Air Control Switch Fitting...1/8 Threads Black Toggle Round Plastic Lever 2012 Air Cylinder Action...Single Diameter...0.625 Length...3.69 Stroke...1.10 Fitting...3/16 Push-In 2013 Air Cylinder Action...Single Diameter...0.75 Length...3.25 Stroke...1.02 Fitting...1/8 NPT Thread 2014 Air Cylinder Action...Single Diameter...0.625 Length...3.69 Stroke...1.10 Fitting...1/8 Push-In 2015 Air Cylinder Action...Double Diameter... 0.69 Length...4.74 Stroke... 0.5 Fitting...1/8 Push-In 2016 Air Cylinder Action...Double Diameter...0.79 Length...4.74 Stroke... 0.375 Fitting...3/16 Push-In 2017 Air Cylinder Action...Dual Shaft Diameter...0.625 Length...3.69 Stroke...1.10 Fitting...3/16 Push-In 2018 Air Cylinder Action...Double Diameter...0.90 Length...2.50 Fitting...3/16 Push-In 2019 Air Cylinder Action...Dual Shaft Diameter... 0.90 Length...4.74 Fitting...3/16 Push-In 2020 Air Control Switch Fitting...1/8 Threads Chrome Toggle 2021 Air Control Switch Fitting...1/8 Threads w/guard, 100psi Black Toggle Plastic Lever 2024 Air Switch Assembly Fitting...1/8 Threads Black Toggle Plastic Lever 2025 Air Switch Assembly Push-on Connectors 2026 Air Control Switch Fitting...1/8 Threads Black Toggle Plastic Lever 2027 Air Control Switch Fitting...1/8 Threads Black Toggle Flat Plastic Lever 510

Listed in ascending order by part number (continued). Air Operated Switches 2028 Air Cylinder Action... Single Fitting... 5/8 Threads used on Duct Assm. FLD Series Frghtlnr BOA80-618-00-039, ABPN83-318031; H061800039 2029 Air Cylinder Freightliner OE# BOA80-618-00-009, 640025.03, BCY8D 2040 Air Control Switch Chrome Push Button Momentary Off - Constant On 2051 Air Control Service Kit 2052 Air Control Service Kit Air Sensing Switches and Solenoid Valves (also see diagram on page 545) AN AIR OPERATED SOLENOID VALVE is an electronic control used to operate (engage & disengage) the air actuated engine fan clutch and/or radiator shutters on the vehicle. It can be plumbed to operate in either a normally open (N.O.) or normally closed (N.C.) position, depending upon the type of fan on the vehicle, and the specific inlet port used on the solenoid. outlet 1655 Refrigerant Solenoid Liquid Line Applications 12v, #6 Male Inserrt O ring 2002 Air Solenoid Valve, 12v Normally Open or Closed 1/8 Thread inlet 2003 Air Solenoid Valve, 12v Normally Open or Closed 1/8 Thread 2004 Air Sensing Switch, NO Male 1/8-27 NPTF Closed between 20-30psi 2005 Air Sensing Switch, NC Male 1/8-27 NPTF Opens at 25psi 2006 Solenoid Valve, NO, 12 volt Continuous Duty 5/16-24 UNF Thrds, Single Pole, 3 Terminal 2007 Solenoid Valve, NO, 24 volt Continuous Duty 5/16-24 UNF Thrds, Single Pole, 3 Terminal 2008 Vacuum Solenoid ProAir OE# 11-000-024 2008H Harness for Vacuum Solenoid ProAir OE# 04-000-039 511

Blower Switch Specifications Toggle, Lever Style Sorted by number of terminals. Rocker Style (continued) Sorted by number of terminals. TYPE TERMINALS PART# FUNCTION COMMENTS TYPE TERMINALS PART# FUNCTION COMMENTS Toggle 2 1020 ON-OFF Universal Toggle 3 1021 ON-OFF-ON Universal Toggle 3 1025 ON-OFF-ON Peterbilt Toggle 3 1030 ON-OFF-ON Lever 3 1036 Chev/GMC Toggle 4 1028 ON-ON-ON Lever 4 1032 4 Position Chev/GMC Lever 4 1033 4 Position Chev/GMC Lever 4 1034 4 Position Lever 4 1037 4 Position Chev/GMC Lever 4 1038 4 Position Ford Lever 4 1039 4 Position Ford Toggle 4 1040 ON-OFF-ON Lever 4 1041 4 Position Chev/GMC Lever 4 1042 4 Position long shaft Toggle 4 1044 ON-OFF Lever 4 1080 OFF-ON-ON-ON Toggle 5 1026 ON-OFF-ON Toggle 5 1045 ON-OFF-ON Lever 5 1050 OFF-ON-ON-ON Lever 5 1055 OFF-ON-ON-ON Lever 5 1056 OFF-ON-ON-ON bent lever Lever 5 1058 OFF-ON-ON Lever 5 1081 OFF-ON-ON-ON Toggle 6 1060 ON-OFF-ON Lever 10 1070 OFF-ON-ON-ON Lever 10 1082 OFF-ON-ON-ON Rocker Style Rocker 2 1167 OFF-ON Volvo Rocker 2 1102 ON-ON Rocker 2 1113 w/2 air lines Freightliner Rocker 3 1104 ON-OFF-ON 15 AMP Rocker 4 1179 ON-ON 24v Rocker 4 1109 OFF-ON-ON 12v Rocker 4 1110 OFF-ON-ON 24v Rocker 4 1111 OFF-ON-ON Rocker 5 1105 ON-OFF-ON Rocker 5 1107 ON-ON Rocker 6 1106 ON-OFF-ON Rocker 9 1115 - Freightliner Rocker 10 1112 - Freightliner Rocker 2 1113 - Freightliner Rocker - 1114 Air control Freightliner Rocker - 1118 Fan control Peterbilt Rocker - 1119 OFF-ON-ON-ON Peterbilt Rotary Style Rotary 3 Pin 1018 - Freightliner Rotary 4 1016 2-speed, fan 12v/24v Rotary 4 1174 Blower Ford/Sterling Rotary 5 1062 - Chev/GMC Rotary 5 1150 3-speed Long threads Rotary 5 1151 3-speed Short threads Rotary 5 1152 Blower switch harness Rotary 5 1165 3-speed GMC/Volvo Rotary 5 1311 5-speed, fan Mack Vision Rotary 6 Pin 1116 Fan Freightliner Rotary 7 1159 w/harness Freightliner Rotary - 1144 Cab control Kenworth Rotary - 1146 Bunk temp. Kenworth Rotary - 1149 Bunk fan Kenworth Rotary - 1154 3-speed 24v w/resistor Rotary - 1155 3-speed 12v w/resistor Rotary - 1157 3-speed w/wiring harness, 12v Rotary - 1158 3-speed w/thermostat control Rotary - 1160 TANDEM 12v w/resistor Rotary - 1164 TANDEM 24v w/resistor Rotary 6 1168 Cab Bunk KW, Pete Rotary - 1170 Front fan Ford E-Models Rotary - 1171 Front fan Ford E-Models 512

Listed in ascending order by part number. Blower Switches SPST = single pole, single throw SPDT = single pole, double throw DPST = double pole, single throw DPDT = double pole, double throw 1016 Fan Switch for Auxiliary Heater, 12/24 volt, 15 AMP (decal included) 2 speed, 4 Terminal 1018 Blower Switch, 3 pin 2003-07 Frghtinr Columbia/Coronado 22-54716-000 1020 Toggle Switch, SPST 2 Terminal ON-OFF 1021 Toggle Switch, SPDT 12/24 volt 3 Terminal ON-OFF-ON 1025 Toggle Switch, SPDT 12/24 volt 3 Terminal ON-OFF-ON 1026 Toggle Switch, DPDT 12/24 volt 5 Term. ON-OFF-ON 1028 Toggle Switch, DPDT 12/24 volt (chrome knob w/cover) 4 Terminal ON-ON-ON 1030 Toggle Switch, SPDT (chrome) 12/24 volt 3 Terminal ON-OFF-ON 1032 Lever Blower Switch 4 Terminal 4 Positions Chev/GMC 16015256 1033 Lever Blower Switch 4 Terminal 4 Positions Chev/GMC 16032480 1034 Blower Switch 4 Terminal 4 Positions 1036 Blower Switch 3 Terminal Chev/GMC 9349679 1037 Blower Switch 4 Terminal 4 Positions Chev/GMC 673528 1038 Blower Switch (harness #1534, knob #1270) 4 Terminal 4 Positions F0HZ-19986A; YH507 1039 Blower Switch 4 Terminal 4 Positions F100-350 D3AZ-19986A 1040 Toggle Switch, DPDT 4 Terminal ON-OFF-ON RD5-5400-0 1041 Lever Blower Switch 4 Terminal 4 Positions Chev/GMC 469368 1042 Blower Sw. (long shaft) 4 Terminal 4 Positions F600-800 D5AZ-19986A 1044 Toggle Switch 4 Term. 2 Pos. ON-OFF Peterbilt 221181KB 513

Listed in ascending order by part number (continued). Blower Switches (continued) SPST = single pole, single throw SPDT = single pole, double throw DPST = double pole, single throw DPDT = double pole, double throw 1045 Toggle Switch, DPDT (black) 12/24 volt 5 Term. ON-OFF-ON 1050 Toggle Switch, SPST, 12/24v 5 Term. OFF-ON-ON-ON harness #1055H, knob #1270 Kenworth K301-19; 65209P 1055 Blower Fan Switch, 12/24 volt 5 Term. OFF-ON-ON-ON harness #1055H, knob #1270 KW W900 221503KB 1056 Blower Switch 5 Term. OFF-ON-ON-ON 1058 Blower Switch 5 Term. OFF-ON-ON Ford L Ser. D0AZ-19986A 1060 Toggle Switch, DPDT (chrome) 12/24 volt 6 Terminal ON-OFF-ON Kysor 220758; 221189 1062 Blower Switch 5 Terminal GM 16054620; 15-71950 1070 Toggle Switch, DPDT 12/24 volt 10 Term. OFF-ON-ON-ON 1080 Blower Switch 4 Term. OFF-ON-ON-ON IHC Transtar 469368 1081 Blower Switch, 5 Term. OFF-ON-ON-ON IHC Nav 472253-C1 1082 Blower Fan Sw, 10 Term. OFF-ON-ON-ON IHC/Navistar 472253-C1 1102 Rocker Switch, SPST 12 volt 2 Terminal ON-ON 1104 Rocker Switch, SPDT 12 volt, 15 AMP 3 Terminal ON-OFF-ON 1105 Rocker Switch, DPDT 12 volt, 15 AMP 5 Terminal ON-OFF-ON 1106 Rocker Switch, DPDT 12 volt 6 Terminal ON-OFF-ON 1107 Rocker Switch, DPST 12 volt 5 Terminal ON-ON 1109 Rocker Switch, DPDT (illuminated) 12 volt 4 Terminal OFF-ON-ON 1110 Rocker Switch, DPDT (illuminated) 24 volt 4 Terminal OFF-ON-ON 1111 Rocker Switch, SPST 12 volt 4 Terminal OFF-ON-ON 1112 Rocker Switch - Bunk 10 Terminal Frghtlnr A06-30769-032 514

Listed in ascending order by part number (continued). Blower Switches (continued) SPST = single pole, single throw SPDT = single pole, double throw DPST = double pole, single throw DPDT = double pole, double throw 1113 Rocker Switch 2 Term. with 2 air lines Frghtlnr ABPN83 322405 1114 Rocker Switch Air Control Frghtlnr ABPN83 322650 1115 Rocker Switch 9 Terminal Frghtlnr A06-30769-011 1116 Rotary Fan Switch, 6 Pin Frghtlnr A22-30822-000 1118 Fan Control, SPST 5 Terminal Peterbilt #CCH33P1 Long 1119 Fan Control, SPDT 5 Terminal OFF-ON-ON-ON Peterbilt #CCH52P1 1144 Cab Control Switch Kenworth 650465BSM 1146 Temp. Circuit Board Sw Kenworth 650396BSM 1149 Bunk - Fan Control Peterbilt #BCH56P1 1150 Universal - Long Thread Rotary Switch 5 Term., 3 spd 12v / 24v, 20 AMP Short 1151 Universal - Short Thread Rotary Switch 5 Term., 3 speed 12v / 24v, 20 AMP 1152 Blower Switch Harness A/C Industries 201-902 5 terminal connector (Fits 1150 & 1151) 1154 24v, 9 AMP Universal Rotary Switch 3 Speed w/resistor 1155 12v, 18 AMP Universal Rotary Switch 3 Speed w/resistor 1157 Rotary Switch, 12 volt 3 Speed w/wiring Harness Frghtlnr A06-14889-001 1158 Concentric Rotary Blwr Sw. with Elec. Thermostat Adj. 5 Term. w/ 2 wire harness Mack 3486-7010509012 1159 Rotary Switch, 7 Terminal w/harness Frghtlnr BOA 80-928-01-029 1160 12v, 15 AMP Rotary Blower Switch TANDEM 3 Spd w/resistor Kysor 220743 1164 24v, 10 AMP Rotary Blower Switch TANDEM 3 Spd w/resistor Kysor 220746 1165 Rotary Blower Switch 5 Terminals 3 Speed Volvo/GMC 60018-0002 515

Listed in ascending order by part number (continued). Blower Switches (continued) SPST = single pole, single throw SPDT = single pole, double throw DPST = double pole, single throw DPDT = double pole, double throw 1167 Rocker Switch 2 Terminal ON-OFF Volvo V1118424 1168 Cab Bunk - Switch 6 Terminal KW, Peterbilt 650624BSM 1170 Front Fan - Ford E-Series F4UZ-19986A; YH585 1171 Front Fan - Ford E-Series E6DZ-19986A; YH445 1174 Blower Switch F-150/350; Sterling F4DZ-19986A; YH588 1179 Rocker Switch - SPST 24 volt, Amber light 4Terminal ON-OFF 1311 Fan Switch, 40 AMP 5 Speed, 5 Terminal 2000-04 Mack Vision 1568 Fan Switch, Aux AC Navistar Prostar 600338-C1 1569 Temp Control Switch, Aux AC, Navistar Prostar 3600339-C1 1583 Blower Switch, 6 Terminal Mack OE# 7787-650882 Switch Knobs, see page 524. Switch Plates 1770 (18-3200) Switch plate rectangle 1771 (18-3201) Switch plate square 1773 (18-3202) Switch plate round 516

Listed in ascending order by part number. Circuit Breakers PUSH TO RESET PUSH TO RESET AUTOMATIC RESET upto 24v PUSH TO RESET 1207 30 AMP, 12v 1210...30 AMP, 12v 1211...15 AMP, 12v 1213...20 AMP, 12v/24v 1214...23 AMP, 12v/24v 1215...40 AMP, 12v/24v 1217...5 AMP, 12v 1216...20 AMP, 12v 1218...25 AMP, 12v 1219...35 AMP, 12v PUSH TO RESET upto 24v AUTOMATIC RESET upto 24v 1201...10 AMP, 12v/24v 1202...20 AMP, 12v/24v 1203...30 AMP, 12v/24v 1204...50 AMP, 12v/24v Manual Reset Carrier/TransAir 1201A...10 AMP, 12v/24v 1202A...20 AMP, 12v/24v 1202B...20 AMP, 12v/24v 1203A...30 AMP, 12v/24v 1204A...50 AMP, 12v/24v Automatic Reset Carrier/TransAir 1360 Circuit Breaker, 12v Freightliner OE# 680-545-19-66 1361 30 AMP, 12v Circuit Breaker Plug-in Type Non-cycling Type II IHC?NAVISTAR OE# 500459-C1 Listed in ascending order by part number. Control Switches 1180 CTC Resistor Kit 1181 CTC Resistor Kit 1184 CTC Control Module 1185 Sleeper Control 517

Listed in ascending order by part number (continued). Control Switches (continued) 1186 Resistor Diode 1187 Push Button Fan Switch 4 Terminal, 3 Button 1190 Bunk Switch (CTC) Freightliner w/behr OE# A06-21497-001 1312 Blower Control Assy Mack OE# 7787-880011 1316 Control Assy - Dash Freightliner Cascadia A22-60645-002 1319 Actuator Service Kit, N.C. Freightliner Cascadia VCCT1000901D 1322 Control Stepper Motor, N.C. Freightliner Columbia BOA91594 1359C Control Switch, Potentiometer 12 volt, 7 Terminal Freightliner OE# N83-322951, BOA98213 1394 Duct Sensor Assy, 2 Pin Freightliner OE# BOAD2512 1520 Temp. Sensor Probe 12 volt, 2 Pin Navistar Prostar 3599601-C1 1539 A/C Control Panel Assembly Navistar 3545543-C5 1567 Heater Constant Discharge Sensor - Aux AC Navistar Prostar OE# 3612055-C3 1584 A/C Control Panel Assembly ABPN83-322930 1585 A/C Control Panel Assembly Kenworth OE# F21-1025-100 518

Listed in ascending order by part number (continued). Micro and Clutch Switches 1235 3 wire, 12v A/C Compressor Switch 1236 Universal A/C Switch, 12v 3 Terminal - Illuminated 1239 2 wire, 12v A/C Compressor Switch 1240 8 AMP, 2 Terminals, 12v SPDT=single pole, double throw V7-1C27E9-292; 118425 1241 15 AMP - 3 Terminals, 12v RD5-5308-0; VL3L3014-D9; 176298; 652100BSM 1242 15 AMP Freightliner BOA80 908 00 219; V7-1C27E9-263; N83-322300 1244 Micro Switch BCH39P1 KW 650471; 85103428 2 Terminal w/o lever Listed in ascending order by part number. Relays NC = normally closed NO = normally open SPST = single pole, single throw SPDT = single pole, double throw DPST = double pole, single throw DPDT = double pole, double throw 1019 15/20 AMP, 24 volt Relay Kit - Weatherproof Seal w/pigtail, w/o Diode 5 wires, 5 Terminal, SPDT (uses 1543 harness, 1262 relay) 1245 Twin-Temp Relay, 12 volt 8 Terminal 1246 Relay, 12 volt, 8 Terminal 1249 Relay, 5 Terminal, SPDT GMC 14089936 519

ELECTRICAL Listed in ascending order by part number (continued). Relays (continued) NC = normally closed NO = normally open SPST = single pole, single throw SPDT = single pole, double throw DPST = double pole, single throw DPDT = double pole, double throw 1250 BOSCH Type, 12 volt 40-30 AMP, w/o Diode 5 Terminal, SPDT (uses #1527 harness) 1250B BOSCH Type, 12 volt, 30 AMP SPDT, 5 Terminal, w/o Diode Carrier 10-00286-01, 10-00286-03 (like #1250 except bracket is on opposite side) 1251 BOSCH Type, 24 volt 10-20 AMP, 5 Terminal (uses #1527 harness) 1252 30-40 AMP, 12 volt 5 Terminal w/diode GMC, Volvo 1254 35 AMP, 4 Terminal, SP / NO grey (rectangle) Topkick, Kodiak 301-1A-S-R1 1255 Blower Relay, 5 Terminal Navistar 447186-C1 1256 Blower Relay, 5 Terminal CHEV/GMC / UNIVERSAL OE# 1115858 3989214 1260 30/40 AMP, 12 volt Relay Kit - Weatherproof Seal w/pigtail, w/o Diode 5 wires, 5 Terminal, SPDT (uses 1543 harness, 1261 relay) 1261 12v, 20/40 AMP 5 Terminal, w/o Diode Weatherproof, SPDT VF4-65F11-12V 1262 24v, 10/20 AMP 5 Terminal, w/o Diode Weatherproof, SPDT VF4A-65H11-24V 1263 40/30 AMP, 12v 5 Terminal, w/diode Weatherproof, SPST VF4-65F11-SO5-12V 1264 30 AMP, 24v 5 Terminal, w/diode Weatherproof, SPST 1265 Freightliner M2 4 Terminal, 70 AMP, SP; NO Sterling F5RZ-14089CB, V23136-J4-X31 1266 5 Terminal, 12v, 30/50 AMP, SPDT Freightliner C112, C120 VF2815F14S01, 898-H-1CH-C-R1 1267 Blower Relay 5 Terminal, 20/10 AMP, SPDT Freightliner 680-545-00-05, VFM15-F41, 12135084, VFM-15-F41 1268 5 Terminal, 20/10 AMP, SPDT; NC Freightliner C112, C120 OE# VJ2895-F24-C05 520

ELECTRICAL Listed in ascending order by part number (continued). NC = normally closed Relays (continued) NO = normally open SPST = single pole, single throw SPDT = single pole, double throw DPST = double pole, single throw DPDT = double pole, double throw 1269 Relay 30/40 AMP, SPST; NC Navistar 2503522-C1 4 Terminal/Green VF4-12F21-Z02; V23136-A4-X75 1290 A/C Relay - 5 Term, 30 AMP, SPDT CHE/GMC 12140647, VF2835F14, 12077864, 12193601 1292 5 Terminal Che/GMC 15670651 1293 4 Terminal, 70 AMP w/diode Normally Open, SPST (uses #1548 harness) Carrier 10-00328-00 1294 Normally Open 4 Terminal, SPST OE# 12193604 1295 Relay w/diode 5 Terminal, 40 AMP, SPDT Carrier/Transair 18-00173; 3607384-C1 1299 Relay, SPDT 5 Terminal, 35/20 AMP Frghtlnr 23-13265-000 1300 Relay, SPDT 5 Terminal, 35/20 AMP Navistar 3519350C9; 301-1C-C-R1 1302 Cooling Fan Relay for single fan 2007-08 Sprinter Van OE# 88098-32 1309 Cooling Fan Relay for dual fan 2007-08 Sprinter Van OE# 68013674AA 1522 Relay, 12 volt, 4 Pin S.P., Normally Open., 20 AMP NAVISTAR PROSTAR 3600330-C1, 303-1AH-C-R1 1523 Relay, 12 volt, 4 Pin S.P., Normally Open., 35 AMP NAVISTAR PROSTAR 3600329-C1, 301-1A-C-R-R1 1573 12 volt, 30 AMP Relay, 4 terminal w/bracket Carrier Bus A/C Systems 10-00286-000; V23134B-1052-C642 1574 12 volt, 40 AMP Relay, 4 terminal w/bracket Carrier Bus A/C Systems 201-806; V23234-B1001-X004 1598 Relay Assortment Kit contains: P/N Description 1250...5 term., 40/30 amp, 12v 1251...5 term., 10/20 amp, 24v 1252...5 term., 30/40 amp, 12v 1261...5 term., 20/40 amp, 12v 1267...5 term., 20/10 amp 1268...5 term., 20/10 amp, NC 521

ELECTRICAL Listed in ascending order by part number. Resistors 1022 Blower Resistor CHEV/GMC OE#15039098 1153 Resistor Block-1.80 OHM 4 Terminal, Trans Air, A/C Ind. 111-060 (Can replace 201-611) 1200 Blower Resistor Navistar, 2500918C1 1220 Resistor 3 Speed, 3 Terminal 1221 Resistor, IHC 4 Speed, 4 Terminal 1222 Mack, Resistor 4 Speed, 4 Terminal 1223P Blower Resistor 4 Terminal, 12 volt Peterbilt 5X010040; P93CAA3100-01S 1224 Resistor 4 Speed, 4 Terminal Kenworth, 2053727-C1 1226 Resistor, 4 Terminal Volvo 3946681 1227 Resistor 3 Speed, 4 Terminal Freightliner 1229 Resistor, Freightliner 4 Speed, 4 Terminal 1230 Resistor, Kysor 3 Speed, 3 Terminal 1232 Resistor, GMC 3 Speed, 3 Terminal 1233 Resistor, Volvo 3 Speed, 3 Terminal 1234 Resistor, Navistar 3 Speed, 5 Terminal 1238 Blwr Res. Circuit Board 3 Speed, 4 Terminal Frtlnr BOA80-926-00-149 522

ELECTRICAL Listed in ascending order by part number (continued). Resistors (continued) 1243 Resistor, 5 Terminal Navistar 3562102C1 1248 Resistor, 4 Terminal Ford/Sterling 4C4H19A-706AA 1297 Resistor Mack 7787-650668 1298 Resistor Che/GMC 52463898 1305 Resistor, 4 Terminal 2003-06 Sprinter Van 2.7TD w/atc 1306 Resistor, 4 Terminal 2007-08 Sprinter Van w/atc 1362 Resistor, 4 Terminal 12 volt Variable Speed, Ceramic 6-1/2 lngth x 1-3/16 dia. J. Deere Crawler/Dozer 650H 1363 Resistor, 4 Terminal, 24 volt Ceramic, Variable Speed 7 lngth x 1-1/4 dia. J. Deere Crawler/Dozer 700H 1364 Resistor, 3 Speed, 4 Terminal, 24 volt Red Dot Units 1365...ID# 1001 1366...ID# 1006 SPAL Blower Motor Resistor 4 Speed, 5 Terminal 1367...ID# 4003 1368...ID# 4004 1369...ID# 4005 SPAL Blower Motor Resistor 3 Speed, 4 Terminal 1521 LPM Module/Resistor 12 volt, 4 spade, 3 pin NAVISTAR PROSTAR OE# 3626414-C1, K2675 1528 Resistor Isuzu OE# 8-98074-114-0 1558 Resistor 5 Terminal, 12v Mack 3543-H2480 1581 Resistor E150-E550; F250SD-F750SD OE# 4C2Z-19A706AA; YH1697 1582 Resistor, 5 Terminal PACCAR OE# 651313BSM, CA1200 523

MISCELLANEOUS Listed in ascending order by part number. Knobs 1270 Control Knob Push On Style 1271 Control Knob 1/4 Shaft Set Screw 1272 Control Knob 1/4 Shaft Set Screw 1273 Control Knob 1/4 Shaft Set Screw 1273A Kysor 5/32 Shaft Set Screw 1274 Control Knob 1/4 Shaft Push On 1275 Control Knob 1/4 Shaft Set Screw 1276 Control Knob 1/4 Push On 1277 Control Knob 1/4 Push On 1280 Control Knob 1/4 Push On 1281 Control Knob Push On 1282 Control Knob 1/4 Shaft Set Screw 1283 Control Knob 1/4 Shaft Push On Kysor OE# 2599041 1283A Mack w/bergstrom A/C OE# 7787-890077 1283B Kenworth OE# 525812 1283C Knob Fastener Clip PACCAR OE# 630049BSM 1285 Control Knob Threaded 1286 Control Knob 1/4 Shaft Set Screw 1287 Control Knob Blue Top 1288 Control Knob Threaded 1291A Red Dot 1/4 Shaft Push On 1800 Freightliner OE# 22-44270-001 1801 Freightliner OE# BOA80-605-00-099 1802 Red Dot Units Knob OE# 71R4035 524 2013 2013 MEI Chad/Preston Corporation

MISCELLANEOUS Listed in ascending order by part number. Louvers and Diffusers 1705 3-1/2 Diffuser with base Includes spring to lock in place. 1706 2-3/16 x 5-7/16 opening Stud Mount 1707 Fits 2-1/2 opening Flush Mount with Retaining Ring 1708 4 x 9-15/16 opening Snap Mount 1709 Fits 1.6 x 5.1 opening Stud Mount 1710 Fits 1-3/4 x 5-1/8 opening Snap Mount 1711 Fits 1-7/8 x 3 5/8 opening Stud Mount 1712 1-15/16 x 4-25/32 opening Stud Mount 1713 1-11/16 x 5-11/16 opening Clip Mount, 100% Shut Off 1714 Fits 2.69 x 6.50 opening Stud Mount 1716 Fits 2-1/2 opening 2 Duct Hose Adapter 1718 Fits 2-1/2 opening 2-1/2 Duct Hose Adapter 1719 3-1/2 Flush Mount Diffuser (includes retaining clip) 1720 3-1/2 Flush Mount Diffuser (includes retaining clip) 1721 Fits 2-1/2 x 2-1/2 opening Pivoting Snap Mount 1722...2-1/2 Defrost Hose 1723...3 Defrost Hose 1724...3-1/2 Defrost Hose 1725 2 x 5-1/2 Snap Mount 1726 2-5/8 Diameter 1728 3-1/4 Diameter 1729 1-5/8 x 5 Snap Mount 525

MISCELLANEOUS Listed in ascending order by part number (continued). Louvers and Diffusers (continued) 1730 4-1/2 Flush Mount Diffuser (includes retaining clip) 1731 Fits 7-3/8 x 2-7/8 opening 1732 Fits 3 opening Flush Snap Mount 1733 Fits 3 opening Flush Snap Mount with adapter for 2-1/2 hose 1734 Fits 3 opening Includes spring to lock in place. 1736 3-7/8 x 1-7/8 opening Freightliner OE# 22-20576-001 1737 3-9/16 x 2-1/4 opening Freightliner OE# ABPN83-317001 1738 3.75 x 0.907 3.25 opening OE# RD5-5222-0 1739 4.75 x 2.0 1.0 deep opening OE# RD5-6987-0 1740 5-3/4 x 1-15/16 opening Freightliner OE# 680-830-00-74 1741 5-3/4 x 1-15/16 opening Freightliner OE# 680-830-01-74 1742 4 dia. x 2-3/4 Mtg. Hole Freightliner OE# A22-40223-000 1743 7-3/8 x 3-3/16 opening Freightliner OE# A22-44135-000 1744 1-3/4 x 5-1/2 opening Navistar OE# 3529263-C1 1745 Light grey Freightliner OE# A22-61254-000 1746 Dark grey Freightliner OE# A22-61254-001 1747 Fits: 3-1/2 x 1-1/2 opening Kysor OE# 3275007 1748 Ball Louver Mounting Hole: 2-3/4 dia. x 2-1/2 Kysor OE# 360224 526

PRESSURE Pressure Switch Specifications Listed in ascending order by OPEN function. CONFIGURATION OPEN CLOSE FITTING PART# CONNECTOR TYPE NORMALLY OPEN LOW PRESSURE (OPEN LOW - CLOSES HIGH) NORMALLY OPEN HIGH PRESSURE (OPEN LOW - CLOSES HIGH) 6 34 1/4 Fem 1434 Screw Mt Bergstrom 6 34 M10 Fem 1435 Screw Mt Bergstrom 6 34 1/4 Fem 1422 MxF Spade w/harness Bergstrom 6 34 M10 Fem 1441 MxF Spade w/harness Bergstrom 8 34 1/4 Fem 1371 WP 2T w/harness Index-APAds 10 20 1579 2W Bobcat 10 30 1/4 Fem 1469 Bare w/harness Bus 10 42 1/4 Fem 1450 Bare w/harness Red Dot 11 39 1/4 Fem 1370 Bare w/harness Index-APAds 12 34 1/4 Fem 1425 Bare w/harness Bergstrom 13 30 M12 Fem 1471 2 PIN Kenworth 15 35 1/4 Fem 1426 1 MB 1F w/harness Peterbilt 15 35 1/4 Fem 1399 WP 2W M w/harness Red Dot 23 47 M12 Fem 1438 2 PIN Red Dot 24 28 M12 Fem 1571 JDeere 25 34 1/4 Fem 1432 MxF Spade w/harness Bergstrom 25 35 1/4 Male 1430 2 Spade Universal 25 45 M12 Fem 1403 2 Pin GMC 30 40 1/4 Fem 1427 WP 2T w/harness Peterbilt 32 42 1/4 Fem 1447 WP 2M w/harness Red Dot 32 42 1/4 Fem 1576 2W JDeere 32 42 M10 Fem 1464 WP 2W M w/harness Red Dot M12 Fem 1519 2 Pin Green Kenworth M12 Fem 1404 2 Pin GMC M12 Fem 1397 2 Pin Ford Male 1303 3 Term Sprinter Van 170 215 1/4 Fem 1452 w/harness Red Dot 190 250 1/4 Fem 1481 Bare w/harness Peterbilt 190 250 M10 Fem 1461 MP 2W M w/harness Red Dot 174 260 1/4 Fem 1454 WP 2W F w/harness Freightliner 180 260 M10 Fem 1446 Bare w/harness Bergstrom 210 260 1/4 Fem 1462 Bare w/harness Bergstrom 210 260 M10 Fem 1442 Bare w/harness Bergstrom 210 260 1/4 Fem 1455 Screw Mt Kysor 210 260 M10 Fem 1457 Screw Mt Bergstrom 210 300 1/4 Fem 1468 WP 2W F w/harness Freightliner 250 300 M10 Fem 1499 WP 2W M w/harness Freightliner 210 340 1/4 Fem 1460 WP 2W M w/harness Peterbilt 205 375 M10 Fem 1492 2 Pin Navistar IHC 250 375 1/4 Fem 1474 MxF Spade w/harness Bergstrom 250 375 1/4 Fem 1497 WP 2F w/harness Red Dot 275 330 M10 Fem 1575 2W Case M10 Fem 1396 2 Pin Ford NORMALLY CLOSED LOW PRESSURE (OPEN HIGH - CLOSES LOW) NORMALLY CLOSED HIGH PRESSURE (OPEN HIGH - CLOSES LOW) (continued) 23 7 M10 Fem 1580 2W Case 27 3 1/4 Fem 1477 MP 2W M w/harness Navistar IHC 30 7 1/4 Fem 1476 MxF Spade w/harness Bergstrom 30 15 1/4 Fem 1433 MxF Spade w/harness Navistar IHC 35 5 M12 Fem 1493 2 Pin Navistar IHC 250 100 1/4 Fem 1482 MP 2W M w/harness Navistar IHC 250 210 M10 Fem 1383 Deutsch 3T w/harness Index-APAds 250 210 1/4 Fem 1390 WP 2T w/harness Index-APAds 260 210 M10 Fem 1443 Bare w/harness Bergstrom 265 180 1/4 Fem 1490 WP 2W M w/harness Freightliner 275 225 1/4 Fem 1484 Bare w/harness Navistar IHC 275 225 M10 Fem 1489 WP 2W M w/harness Navistar IHC 275 235 1/4 Fem 1380 WP 2T w/harness Index-APAds 275 235 1/4 Fem 1389 Deutsch 3T w/harness Index-APAds 275 235 1/4 Fem 1391 WP 2T w/harness Index-APAds 280 240 1/4 Fem 1496 WP 2W M w/harness Navistar IHC 285 240 M10 Fem 1459 WP 2W F w/harness Kenworth 300 200 1/4 Fem 1488 MxF Spade w/harness Bergstrom 300 200 M10 Fem 1440 MxF Pack w/harness Bergstrom 300 210 1/4 Fem 1486 MxF Spade w/harness Navistar IHC 527

PRESSURE Pressure Switch Specifications Listed in ascending order by OPEN function. CONFIGURATION OPEN CLOSE FITTING PART# CONNECTOR TYPE (continued) NORMALLY CLOSED HIGH PRESSURE (OPEN HIGH - CLOSES LOW) 300 210 M10 Fem 1458 WP 2W M w/harness Navistar IHC 300-325 220 1/4 Fem 1388 WP 2T w/harness Index-APAds 300 250 M10 Fem 1498 WP 2W M w/harness Freightliner 300 250 1/4 Fem 1387 Deutsch w/harness Index-APAds 300 260 M10 Fem 1385 WP 2T w/harness Index-APAds 300 265 M10 Fem 1384 Deutsch 3T w/harness Index-APAds 310 210 1/4 Fem 1495 WP 2W M w/harness Navistar IHC 325 250 1/4 Fem 1491 MxF Spade w/harness Universal 325 275 M10 Fem 1386 MP 2T w/harness Index-APAds 330 180 M10 Fem 1439 2 Pin Paccar 340 210 1/4 Fem 1487 WP 2M w/harness Red Dot 350 260 M10 Fem 1445 MxF Spade w/harness Bergstrom 355 250 M10 Fem 1472 2 Pin Kenworth 375 200 1/4 Fem 1494 Bare w/harness Bergstrom 390 240 M10 Fem 1577 2W Case, JDeere 400 300 1/4 Fem 1572 2W Carrier 430 275 M10 1465 Bare w/harness - M10 Fem 1324 4 Term Ford Miscellaneous - Air, Cycling, Cut-Off, Sensors, Solenoids, Temperature and Transducers CONFIGURATION OPEN CLOSE FITTING PART# DESCRIPTION Accumulator Press Sw. - M10 1570 Linkbelt Excavator AP A220-430-0 Air sensing switch - 20-30psi Male 1/8-27 NPTF 2004 Normally Open Air sensing switch 25psi - Male 1/8-27 NPTF 2005 Normally Closed Air sensing (liquid line) - #6 MIO 1655 Refrigerant Solenoid Liquid Line Applications, 12V Compr Refrigerant 350psi 250psi M10 male 1436 NC, 2 pin, Green, GM 15966454 Cut-off switch - - M12 Thread 1424 Low press; 2 pin, GM 52466101 Cut-off switch - - M12 Metric thread 1453 NO, Low press; 2 pin; GMC 10242579 Cut-off switch - 257 F - 1402 NC, High press; BLUE, 2 pin; GM 2724333 Cut-off switch 25psi 35psi 3/8-24 Male Spade 1430 NO, Low press; RD5-6394-0 Cycling switch - - M12 Metric female 1403 GMC Topkick/Kodiak 02-06; 1132749; 2 pin Cycling switch - - M12 Thread 1404 GMC Silverado, Suburban 02-07; 31587917; 2 pin Cycling switch on at 46psi off at 25psi 1/4 SAE 1411 Normally Open, Accumulator, Ford, R12 Cycling switch on at 46psi off at 23psi M12, female 1412 Normally Open, Accumulator, Ford, R134a Cycling switch on at 46psi off at 25psi 1/4 female flare 1410 Normally Open, Accum., 3041409, 3041596 Cycling switch 30-32psi 38-40psi 7/16-20 female UNF 1413 R12; 15-2647; GMC 52457853 Cycling switch 30-32psi 38-40psi M12 Metric female 1414 R134a; 2 Male Spade, 52460878 Cycling switch 30-32psi 38-40psi M12 Metric female 1416 NO, R134a; GMC 5466358 Cycling switch 25psi 45psi M12 Thread 1418 NO, Low press., Ford F5VY-19E561A; 2 pin Cycling switch - - M12 Thread 1417 Low press., GMC 52468323 Cycling switch - - M12 Thread 1419 Low press., 2 spade, GM 52458249 Cycling switch (accumulator) - 3/16 thread, R134a 1463 NO, GMC 12546085, 15765001, 2 pin, beige Cycling switch (compressor) - M12, R12 1421 NO, GMC 52457854; 2 pin, black w/yellow Cycling switch (compressor) - M12, R12 1423 NO, Low press.,black w/yellow, GM 52457853 Cycling switch - - M12 1429 Low press.,2 pin, GMC 52473139 Fan Override 190 250 1/4 Fem 1448 NO, MP 2W M w/harness, Red Dot Fan Override 200 270 M10 Fem 1437 NO, 2 Pin, Red Dot Fan Override 210 260 1/4 Fem 1456 NO, Bare, w/harness, Bergstrom Fan Override 250 100 M10 Fem 1451 NC, MP 2W M w/harness, Navistar IHC Fan Override 310 240 M10 1310 NC, Peterbilt, 2 pin, 79PSL3-4 Fan Temp. Timer set point 205 1449 International 1622647-C91; 205NC-432 Freon Sensor (fits #7415 accum) M12 threads 1400 Navistar 3548043-C1 Pressor Sensor - - 1353 Climate control sw., Volvo 20832008 Solenoid valve - - 1/8 thread 2002 Normally Open or Closed; 12V Solenoid valve - - 1/8 thread 2003 Normally Open or Closed; 12V Solenoid valve - - - 2006 Continuous duty; 12V Solenoid valve - - 2007 Continuous duty; 24V Superheat Sw Kit - - - 1406 Superheat; GM compressors,12v Temp. switch (ambient) - - 1398 Ford YC3Z-19C733CA; YH1532 Temp. switch 200 F switch clamps to 3/8 tube 1415 2 wire, 2 terminal; normally closed Transducer M10, 3 pin 1314 Black, Frghtlnr 22-60646-000; 2CP55-1 Transducer M10, 3 pin 1473 Brown, International 3546241C1 Transducer Male thrd, 3 terminal 1475 International 1839415-C91 Transducer 3 pin 1557 GMC w/denso Compr. 22634172 528

PRESSURE Pressure Switch Identification 20PS 002 M A 250 E 100 k Vender Spec Codes Standard Port Fitting A 1/4 NPTF Male Port E 1/8 NPTF Male Port H 1/4 SAE Male Flare J 1/8 NPTF Female Port M with valve core depressor Switch Setting A NO B NC C NO D NC E NO F NC J NO K NC L NO M NC N NO P NC T NO U NC Actuation Pressure Deactuation Pressure Tolerances Code ± psi C 3 D 4 E 5 F 6 G 7 H 8 J 9 K 10 R 15 NOTE: Lt. Blue Wire = NO Switch Black Wire = NC Switch Normally Open = NO Normally Closed = NC Also See INDEX SENSORS and CONTROLS (APADS) Section, pages 546-551. Binary and TrinaryTM Switches R12/R134a Compatible Binary Switches perform two functions; A. Prevents compressor operation if system has refrigerant loss or ambient temp. drops too low. B. Prevents compressor operation if high side pressure rises too high. Automatically resets when pressure drops to normal. Trinary II Switches are found on systems equipped with radiator shutters and/or electric or air fan clutches. They perform three functions: A. Prevents compressor operation if system has refrigerant loss, or ambient temp. drops too low. B. Prevents compressor operation if high side pressure rises too high. Automatically resets when pressure drops to normal. C. Overrides shutter/fan control to keep head pressure within normal range. BINARY OPEN CLOSE THREAD PART# CONNECTOR HARNESS APPLICATION 15-270 40-120 1/4 Fem 1510 2 Spade None Red Dot 15-270 40-120 1/4 Male 1500 2 Spade None Red Dot 28.5 395 1/4 Male 1516 2 Spade None Universal 28-38 227-312 M10 Fem 1511 MP 2W M w/harness Mack 28-40 341-455 M10 Fem 1514 2 Pin None Freightliner 350-28 227/40 1/4 Fem 1512 2 Spade None Freightliner 350-28 227/40 M10 Fem 1513 2 Spade None Freightliner 390-28 260-28 7/16-20 FF 1578 2W None Bobcat M10 Fem 1324 NC, 4 Term None Ford M10 Fem 1431 4 Terminal None Ford 241/40 426/28 M10 Fem 1515 2 Pin None PACCAR 1538 w/harness CAT TRINARY OPEN CLOSE THREAD PART# FUNCTION HARNESS APPLICATION 22-325 40-230 1/4 Fem 1560 NO None Red Dot 22-325 40-230 1/4 Male 1550 NO None Red Dot 22-325 40-230 1/4 Fem 1565 NC None Red Dot 22-325 40-230 1/4 Male 1555 NC None Red Dot Gold sticker designates Normally Closed, NC Silver sticker designates Normally Open, NO 529

PRESSURE Listed in ascending order by part number. Pressure Switches NC = Normally Closed NO = Normally Open 1303 Pressure Switch, 3 Terminal 2.7TD (fits on drier) 2003-06 Sprinter Van INDEX 351028161 1310 ORANGE, Fan Override Switch, NC (uses harness #1559) M10 Threads, 2 Pin Open: 310psi, Close: 240psi Peterbilt, 79PSL3-4 1314 BLACK, Transducer, 3 Pin M10 Threads Freightliner/Cascadia 2CP55-1, 22-60646-000 1324 GREEN, High Pressure Binary, NC 4 Terminal, M10-1.25 thrd M.P. = 325-270psi H.P. = 465-235psi Sterling 06-35209-000 1353 Pressure Sensor Climate Control Volvo OE# 20832008 reorder# 8040201P 1370 Bare Leads Low pressure, normally open Open: 11psi, Close: 39psi, R12 Only INDEX 8040201P reorder# 8040204P 1371 Weatherpak Low pressure, normally open Open: 8psi, Close: 34psi, R12 Only INDEX 8040204P reorder# 8040243P 1380 Weatherpak High pressure, normally closed Open: 275psi, Close: 235psi, R12 Only INDEX 8040137P, 8040243P reorder# 8040235P reorder# 8040088P reorder# 8040164P reorder# 8040239P 1383 Deutsch 1384 Deutsch 1385 Weatherpak 1386 Metri-Pack High pressure, normally closed Open: 250psi, Close: 210psi M10 Female Schrdr, R12 Only INDEX 8040235P High pressure, normally closed Open: 300psi, Close: 265psi M10 Female Schrader, R134a INDEX 8040088P High pressure, normally closed Open: 300psi, Close 260psi M10 Female Schrader, R134a INDEX 8040164P High pressure, normally closed Open: 325psi, Close: 275psi M10 Female Schrader, R134a INDEX 8040239P reorder# 8040134P 1387 Deutsch High pressure, normally closed Open: 300psi, Close: 250psi, R12/R134a INDEX 8040134P reorder# 8040225P 1388 Weatherpak High pressure, normally closed Open: 300/325psi, Close: 220psi, R12/R134a INDEX 8040225P reorder# 8040082P 1389 Deutsch High pressure, normally closed Open: 275psi, Close: 235psi, R12/R134a INDEX 8040082P reorder# 8040230P 1390 Weatherpak High pressure, normally closed Open: 250psi, Close: 210psi, R12/R134a INDEX 8040230P 530

PRESSURE Listed in ascending order by part number (continued). Pressure Switches NC = Normally Closed NO = Normally Open reorder# 8040231P 1391 Weatherpak High pressure, NC Open: 275psi, Close: 235psi, R12/R134a INDEX 8040231P 1396 M10 Threads, 2 Pin (uses harness #1562) Sterling F3AZ-19D594C; 6L2Z-19D594AA 1397 Pressure Cycling Switch, BLUE (uses harness #1562) M12 Threads, 2 Pin E-Ser. 2003-1999, YH1579 1399 Low Pressure, NO On: 15psi, Off: 35psi, RD5-6395-1 1400 Freon Sensor, M12 Threads uses harness #1544K (fits #7415 accumulator) Navistar 3548043-C1 1402 BLUE, Cut-out Switch High Pressure, R134a GM 2724333 1403 A/C Cycling Switch M12 Threads, 2 Pin (uses harness #1559) Topkick/Kodiak 02-06 GMC 1132749 1404 A/C Cycling Switch M12 Threads, 2 Pin (uses harness #1559) Silverado, Suburban 02-07 31587917 1406 Superheat Switch Kit, 12v for Rear Port on GM Comp 1410 Accum. Press Cycling Switch Normally Open On: 46psi, Off: 25psi Female 1/4 1411 Accum. Cycling Switch Normally Open On: 46psi, Off: 25psi Female 1/4, Ford, R12 1412 Accum. Press. Cycling Switch Normally Open, R134a On: 46psi, Off: 23psi Female 12MM, Ford 1413 Cycling Switch, R12 Open: 30-32psi Close: 38-40psi 7/16-20 Female; 1/4 thrd 15-2647; GM 52457853 1414 Low Press, R134a, NO Open: 30-32psi Close: 38-40psi 2 Male Spade M12 Metric Female GM 52460878 1415 High Temperature Switch Normally Closed Opens: 200 F Attaches to 3/8 Tube 1416 R134a, Low Pressure, NO Open: 30-32psi Close: 38-40psi M12 Metric Female, 2 pin GM 52466358 1417 Low Pressure, Cycling Switch Fan Control GM 52468323 1418 Clutch Cycling Switch, NO 12mm (R134a) Low Press. 2 Pin (uses harness #1562) Open: 25psi, Close: 45psi FORD #F5VY-19E561A, F6RZ-19E561AA 1419 Low Pressure Cycling Switch M12 Threads, 2 Spade (uses harness #1526) GM 52458249 1421 Compressor Pressure Cycling Switch, R12 black w/yellow band - 2 pin CHEV/GMC 52457854 531

PRESSURE Listed in ascending order by part number (continued). Pressure Switches (continued) NC = Normally Closed NO = Normally Open 1422 Packard Low Presssure, NO Open: 6psi, Close: 34psi 20PS125MA034D006B 1423 Low Press A/C Cycling Switch M12 Thread GM 52457853; 15-2647 1424 Low Pressure Compr. Cut Off Switch GM 52466101 1425 Low Pressure, NO 1 Male Bullet 1 Female Open: 12psi, Close: 34psi (404162) 1426 Low Pressure, NO 1 Male Bullet 1 Female Open: 15psi, Close: 35psi 18-03285; 2OPS 39-10 1427 Low Pressure (R134a) NO Open: 30psi, Close: 40psi PETERBILT 18-03599; 20PS39-15 1429 Low Press Cycling Switch M12 Thread GM 52473139; 15-5643 1430 Low Pressure Switch, 2 Spade Normally Open. (R12) Male Thread 3/8-24 UNF-2A On: 25psi, Off: 35psi UNIVERSAL 1/4 SAE Red Dot OE# RD5-6394-0 Prevents compressor damage, mounts on drier, used on Red Dot, Frghtlnr, KW, Peterbilt, and White. (Harness #1526) 1431 BLACK, High Press Binary Sw 4 Terminal, M10-1.25 thrd M.P. = 330-238psi H.P. = 464-237psi FORD L-Series F3DH19D594AA 1432 Packard Low Pressure, NO (R12) Open: 25psi, Close: 34psi 2OP127MA034D025G 1433 Low Pressure, NC (R12) Opens: 30psi, Closes: 15psi Female Thrd 1/4 SAE Navistar 547650-C1; 20PS134-5 1434 Low Pressure, NO 2 Spade Thrd Open: 6psi, Close: 34psi 1435 Low Pressure, NO 2 Spade Thrd Open: 6psi, Close: 34psi 10MM Metric Female 1436 Refrigerant Press Switch, NC (R134a) Green, 2 Pin M10 Male thread Open: 350psi, Close: 250psi CHEV/GMC #15966454 1437 GRAY, High Pressure, NO Open: 200psi, Close 270psi 10MM Female Flare P93CAA-3606-01 1438 TAN, Low Pressure, NO Open: 23psi, Close: 47psi 12MM Metric Female P93CAA-3604-1 1439 PURPLE, High Press., NC M10, Female, 2 pin Open: 330psi, Close: 180psi PACCAR 18-03835 1440 R134a, High Pressure, NC Open: 300psi, Closes: 200psi M10 Metric thrd., Female KYSOR OE# 404285, 404277, 20PS310-6 1441 Packard Low Pressure, NO Open: 6psi, Close: 34psi 10MM Metric Female 404279; 20PS309-9 1442 High pressure, NO Open: 210psi, Close: 260psi 10MM Metric Female 404283; 20PS309-11 532

Listed in ascending order by part number (continued). Pressure Switches (continued) PRESSURE NC = Normally Closed NO = Normally Open 1443 High pressure, NC Open: 260psi Close: 210psi 10MM Metric Female 404284; 20PS310-7 1445 High Pressure, NC Open: 350psi Close: 260psi 10MM Metric Female 404274; 20PS310-6 1446 High Pressure, NO Open: 180psi Close: 260psi 10MM Metric Female 404276; 20PS309-8 1447 RED, Low Pressure, NO Open: 32psi Close: 42psi RD5-6834-0; 20PS39-26 1448 RED, Fan Override, NO Open: 190psi Close: 250psi RD5-6835-0; 20PS39-25 1449 BLUE, INDEX/APADS Fan temp. timer switch Set Point 205, NC Navistar 1622647-C91, 8036079P; 205NC-432 1450 Low Pressure, NO Open: 10psi, Close: 42psi RD5-4833OP; 20PS39-24 1451 GREY, Fan/Shutter Sw., NC (R134a) Open: 250psi, Close: 100psi Female Metric M10 Thrd Navistar 3521727-C1 1452 High Pressure, NO Open: 170psi, Close: 215psi RD5-6394-0; 20PS39-4 1453 A/C Low Press (R134a) Cut Off Switch M12 thread, 2 pin CHEV/GMC 10242579 1454 High Pressure, NO Open: 174psi, Close: 260psi A22-30930-0; 20PS39-11 1455 High Pressure, NO 2 Spade Thrd Open: 210psi, Close: 260psi 1456 High Pressure, NO Open: 180psi, Close: 260psi 20PS131MA260K180K 1457 High Pressure, NO 2 Spade Thrd Open: 210psi, Close: 260psi 10MM Metric Female 1458 Packard Sky Blue (R134a) High Pressure, NC Open: 310psi, Close: 210psi Female Metric M10 thrd Nastar OE# 3521728-C1 1459 RED, High Pressure, NC Open: 285psi, Close: 240psi M10 Female; K301-382, K301-401, 40PS17-1 1460 High Pressure, NO (R134a) 1/4 SAE Open: 210psi, Close: 340psi PETERBILT 18-03600, 20PS40-11 1461 High Pressure, NO Open: 190psi, Close: 250psi M10-1.25 Female Metri-Pack RD5-10096-0 1462 High Pressure, NO Open: 210psi, Close: 260psi Kysor 404163 1463 Beige, Accumulator (R134a) 3/16 Thread, 2 Pin CHE/GMC 12546085, 15765001 533

PRESSURE Listed in ascending order by part number (continued). Pressure Switches (continued) NC = Normally Closed NO = Normally Open 1464 Low Press (on hi-side) Metric M10, NO Open: 32psi, Close: 42psi OE# 20PS309-26; RD5-9267-0 1465 High Pressure w/harness Metric M10, NC Open: 430psi, Close: 275psi 1468 High Pressure, NO Open: 210psi, Close: 300psi OE# 20PS39-36, 37; BOA80-926-00-091 1469 Low Pressure, NO Open: 30psi, Close: 10psi 1/4 SAE, 11 leads Trans Air A/C #111-025 AC Ind. OE# 201-404 1471 Low Press Sw, NO, 2pin (harness 1546) M12 Open: 13psi, Close: 30psi KW 650446, F27-1002 1472 High Press., NC, 2 pin (harness 1546) M10 Open: 355psi,Close: 250psi KENWORTH 650697 1473 Brown, Transducer M10, 3 Pin (pigtail #1561) International 2006-2001 4000, 7000, 8000 Series International 3546241C1 1474 Packard High Press., NO, R12 Open: 250psi, Close: 375psi, Kysor 404121, IHC/Navistar 442182-C1; 2OPS034MA375K250R 1475 Transducer, Male Threads 3 Terminal (pigtail #1561) International OE# 1839415-C91 1476 Packard Low Press., NC, R12 Open: 30psi, Close: 7psi, Kysor 404123, IHC/Navistar 442183-C1; 2OPS029MB030E007C 1477 GREY, Low Press., NC, R134a Open: 27psi, Close: 3psi Female Thread 1/4 SAE Navistar 1661273-C1; 20PS40-3 1481 High Pressure, NO Open: 190psi, Close: 250psi PETE 18-03601; 20PS39-16 1482 GREEN, High Pressure, NC Open: 250psi, Close: 100psi IHC/Navistr 1651985-C1; 20PS40-2 1484 High Press., NC, R12 Open: 275psi, Close: 225psi 20PS028MB260K210K 1486 Packard High Press., NC, R12 Open: 300psi, Close: 210psi IHC/Navistar 480869-C1 20PS059MB300K210K 1487 RED, High Pressure, NC Open: 340psi, Close: 210psi RD5-6833-0; 20PS40-20 1488 Packard High Press., NC, R12 Open: 300psi, Close: 200psi Kysor 404141; IHC/Navistar 544975-C1 20PS030MB300K200K 1489 RED, High Pressure Switch (R134a) NC Open: 275psi, Close: 225psi Female Metric M10 Thrd Navistar 3521729-C1 1490 High Pressure, NC Open: 265psi, Close: 180psi Frghtlnr A22-30930-001 20PS40-7 1491 Packard High Press., NC, R12 Open: 325psi, Close: 250psi 20PS129MB350K250K 534

Listed in ascending order by part number. Pressure Switches (continued) PRESSURE NC = Normally Closed NO = Normally Open 1492 GREEN, High Press., NO Open: 205psi, Close: 375psi M10 Female, 2 Pin, R143a IHC/Navistar 1676787C1 1493 BLACK, Low Press., NC, 2 pin Open: 35psi, Close: 5psi Metric M12 Female IHC/Navistr 1676786C2 1494 High Pressure, NC Open: 375psi, Close: 200psi 1495 High Pressure, NC Open: 310psi, Close: 210psi 1/4 Female Thread Navistar 1651984C1; 20PS40-1 1496 High Pressure, NC Open: 280psi, Close: 240psi 1/4 Female, R134a 2035274C1; 40PS8-1 1497 Packard High Pressure, NO Open: 250psi, Close: 325psi 1/4 Female OE# 521728C1; 20PS39-54 1498 Fan Override, NC Open: 300psi, Close: 250psi M10-1.25 Female A22-45194-1; 40PS15-1 1499 High Pressure, NO, GREY Open: 250psi, Close: 325psi M10-1.25 Female A22-45194-000; 41PS5-1 1519 Low Press Sw; N.O., GREEN M12 (harness #1546 and fits #1644 exp. vlv) 2 Pin OE# 2214003; B652578 1538 Binary Switch w/harness CAT OE# 114-5333 1557 Transducer, 3 pin (pigtail #1561) GMC w/denso Compressor OE# 22634172 1570 Accumulator Press Switch M10 - Linkbelt Excavator APA220-430-0 1571 Low Press Sw for Filter Drier Normally Open. Open: 24psi, Close: 28psi J Deere 4709907 Excavators 75-270CLC 1572 High Pressure, NC Open: 400psi, Close: 300psi Carrier 201-414 1575 High Pressure, NO 10MM Thread Open: 275psi, Close: 330psi CASE 232948A1 1576 Low Pressure Switch, NO 1/4 Thread Open: 32psi, Close: 42psi J Deere RE155938, RE60887 1577 High Pressure, NC 10MM Female Thrd, 1.25 pitch Open: 390psi, Close: 240psi J Deere 87000227 CASE 284273A1, A2 1578 Binary Switch, NO 7/16-20 Female Flare HIGH: Open: 390 / Close: 260 LOW: Open: 28 / Close: 28 Bobcat Skidsteer 6675779 1579 Low Press Sw., NO Open: 10psi, Close: 20psi Bobcat Skidsteer 6679085 1580 Low Pressure, NC 10MM Female Thread Open: 23psi, Close: 7psi CASE 122579A1 535

PRESSURE Listed in ascending order by part number. Pressure Switches (continued) NC = Normally Closed NO = Normally Open 1586 Trinary Switch 3/8-24 Thread Isuzu OE# 8-97366-964-0 1587 Trinary Switch M11-1.0 Thread Isuzu OE# 1-83564-392-1 1588 Trinary Switch Isuzu OE# 8-97095-659-0; 8-97366-963-0 1589 Trinary Switch Isuzu OE# 1-83539-218-0 1597 SWITCH ASSORTMENT KIT Kit contains: Qty. P/N Description 1 ea...1324...m10-1.25 High Pr., Binary, NC 1 ea...1400...m12 Freon Sensor 1 ea...1437...10mm Female, High Pr., NO 1 ea...1438...12mm Female, Low Pr., NO 1 ea...1439...m10 Female, High Pr., NC 1 ea...1473...m10 Transducer (3 pin) 1 ea...1489...m10 Female, High Pr., NC 1 ea...1492...m10 Female, High Pr., NO 1 ea...1493...m12 Female Low Pr., NC 1 ea...1498...m10 Female, High Pr., NC 1 ea...1511...m10 Female Binary, NC 1 ea...1512...r12 Female Binary, NO 1 ea...1513...m10 Female Binary, NO 1 ea...1514...m10 Binary, NC 1 ea...1515...m10 Binary (brown) 1 ea...1519...m12 Low Pr., NO Transducers 1314 Transducer BLACK M10 thrds, 3 Pin Freightliner/Cascadia OE# 2CP55-1; 22-60646-0 1473 Transducer BROWN M10 thrds, 3 Pin (pigtail #1561) International 2006-2001 4000, 7000, 8000 Series International OE# 3546241C1 1475 Transducer, Male threads 3 Terminal (pigtail #1561) International OE# 1839415-C91 1557 Transducer, 3 pin (pigtail #1561) GMC w/denso Compressor OE# 22634172 536

PRESSURE Binary Switches NC = Normally Closed NO = Normally Open Binary switch performs two functions: 1. Prevents compressor from operating if system charge is lost or ambient temperature is too low. 2. Prevents compressor from operating if head pressure increases to unsafe levels, automatically resetting when pressure returns to normal. illustration (1) TO CLUTCH (Black Wire) 1 2 (2) TO THERMOSTAT (Black/White Wire) BINARY PRESSURE PROTECTION Low Pressure Opens Closes 30-15PSIG 40PSIG Max (Falling Pressure) (Rising Pressure) High Pressure 270-330PSIG 80-120PSIG Below (Rising Pressure) (Falling Pressure) 1324 GREEN, High Press Binary, NC 4 Terminal, M10-1.25 thrd M.P. = 325-270psi H.P. = 465-235psi Sterling 06-35209-000 1431 BLACK, High Press Binary Sw 4 Terminal, M10-1.25 thrd M.P. = 330-238psi H.P. = 464-237psi FORD L-Series OE# F3DH19D594AA 1500 Male Binary Sw. (see illustration) (harness #1524) 3/8-24 Male Thread HIGH: Off: 270 / On: 120 LOW: Off: 15 / On: 40 Red Dot OE# RD5-4646-0; 71R-7000 1510 Binary Sw. (see illustration) (harness #1524) 7/16-20 Female, 1/4 SAE HIGH: Off: 270 / On: 120 LOW: Off: 15 / On: 40 Red Dot OE# RD5-4640-0; 71R-7050 1511 Female Binary, M10, NC w/harness HIGH: Off: 312 / On: 227 LOW: Off: 28 / On: 38 Mack OE# IMR-3550M 1512 Female Binary, NO, R12 only (harness #1526) 1/4 SAE HIGH: Off: 350 / On: 227 LOW: Off: 28 / On: 40 Freightliner OE# 22-36474 1513 Female Binary, M10, NO (harness #1526) HIGH: Off: 350 / On: 227 LOW: Off: 28 / On: 40 Freightlnr 22-43249-000 1514 Binary Switch, M10, NC (harness #1546) HIGH: Off: 455 / On: 341 LOW: Off: 28 / On: 40 Freightliner #22-51296-000 1515 BROWN, Binary Switch M10, 2 Pin (harness #1546) HIGH: Off: 426 / On: 241 LOW: Off: 28 / On: 40 Kenworth/Peterbilt OE# K301-370-1; 79PSD4-1 1516 Binary Cut-out Switch, NC (harness #1526) 3/8-24 Male Thrd HIGH: Off: 394 / On: 227 LOW: Off: 28 / On: 40 ID# GY309-23A 1538 Binary Switch w/harness CAT OE# 114-5333 1578 Binary Switch, NO 7/16-20 Female Flare HIGH: Open: 390 / Close: 260 LOW: Open: 28 / Close: 28 Bobcat Skidsteer 6675779 537

PRESSURE Trinary Switches NC = Normally Closed NO = Normally Open Trinary switch performs three functions: (Gold sticker designates Normally Closed / Silver sticker designates Normally Open) 1. Prevents compressor from operating if system charge is lost or ambient temperature is too low. 2. Prevents compressor from operating if head pressure increases to unsafe levels, automatically resetting when pressure returns to normal. 3. Overrides fan/shutter control to keep head pressure within normal range by opening shutters or operating engine fan. ILLUSTRATION 4 (4) TO POWER (Orange Wire) 3 (3) TO SOLENOID, FAN (Yellow Wire) (1) TO CLUTCH (Black Wire) 1 2 (2) TO THERMOSTAT (Black/White Wire) TRINARY PRESSURE PROTECTION Low Pressure Opens Closes 22.5±7.5PSIG 40PSIG Max (Falling Pressure) (Rising Pressure) High Pressure 325±25PSIG 230±20PSIG Shutter/Fan Override 35±60PSIG 200-230PSIG (Falling Pressure) (Rising Pressure) Listed in ascending order by part number. 1550 Trinary II Switch, NO for Fan/Override/Shutter Circuit 3/8-24 Male Thread HIGH: Open: 325 / Close: 230 LOW: Open: 22 / Close: 40 Red Dot OE# RD5-4585-0; 71R-7500 1555 Trinary II Switch, NC for Fan/Override/Shutter Circuit 3/8-24 Male Thread HIGH: Open: 325 / Close: 230 LOW: Open: 22 / Close: 40 Red Dot OE# RD5-4620-0; 71R-7600 1560 Trinary II Switch, NO for Fan/Override/Shutter Circuit 7/16-20 Female Thread Red Dot OE# 71R-7550; RD5-4583-0 1565 Trinary II Switch, NC for Fan/Override/Shutter Circuit 7/16-20 Female Thread HIGH: Open: 325 / Close: 230 LOW: Open: 22 / Close: 40 Red Dot OE# 71R-7650; RD5-4625-0 1586 Trinary Switch 3/8-24 Thread Isuzu OE# 8-97366-964-0 1587 Trinary Switch M11-1.0 Thread Isuzu OE# 1-83564-392-1 1588 Trinary Switch Isuzu OE# 8-97095-659-0; 8-97366-963-0 1589 Trinary Switch Isuzu OE# 1-83539-218-0 538

Listed in ascending order by part number. Thermister/Temperature Components TEMPERATURE SENSORS 1307 Temp. Sensor for Evaporators Mack, Sprinter Van 2003-06, 2.7TD OE# 05103937AA 1313 Sensor/Discharge Air Century Class/Columbia 1317 Evaporator Probe Kit Freightliner Cascadia OE# VCCT1000902E 1323 Control Temp. Sensor Freightliner Cascadia OE# VCCT1000903U 1347 Temperature Probe Switch Freightliner OE# BOA91619 1356 Thermister Probe Mack Truck 1359 Evaporator Temp. Probe Freightliner OE# VCC 83000036 1394 Duct Sensor Assembly, 2 Pin FREIGHTLINER OE# BOAD2512 1398 Air Temperature Control ATC Sensing Unit Ford YC3Z-19C733CA 1520 Temp. Sensor Probe 12 volt, 2 Pin Navistar Prostar OE# 3599601-C1 539

THERMOSTATIC Thermostat Specifications Sorted in ascending order by Capillary Length. NOTE: Thermostatic switches listed close at higher temperature and open at lower temperature. CAPILLAry TEMPRATURE CLUTCH HOLE ILLUSTRATIOn length PART# RANGE CYCLING SPACING NOTES Cable Controlled Thermostats 21 1343 31 F 40 F - 2 1/8 V1118416 24 1537 26 F 34 F - 2 1/8 MCC Units 30 1327 34 F 54 F 5 F 2 15/16 Pull for cold 42 1328 30 F 62 F 10 F 2 15/16 Pull for heat Fixed (Preset) Setting Thermostats 12 1342 31 F 39 F - - 9533N538 12 1345 30.5 F 44.5 F - - 30-899682, 3039429 16 1315 28 F 35 F 7 F - BD1080 18 1334 24 F 36 F - - A45-1061; 9533N401 21 1340 31 F 40 F - - 9533-478 24 1331 34 F 38 F 5 F 2 1/8 24 1332 31 F 39 F 8 F 2 1/4 Side mount 24 1333 34 F 44 F 8 F 2 3/16 30 1349 - - - - Volvo 3093431 31 1/2 1341 31 F 40 F - - BD1430-1344 - - - - Ford 40 Ser., 82034877 Rotary Thermostats 11 1536 ambient - - Eaton 9533N383 18 1318 28 F 62 F 6 F - A45-1033 27 1335 34 F 52 F 5 F - RD4172-0 36 1351 34 F 26 F - - Volvo/GM 36 1336 34 F 52 F 5 F - RD4125-36 48 1348 34 F 52 F 5 F - A10-6495-00 72 1337 34 F 52 F 5 F - A10-6499 - 1325 60 F 80 F - - Bi Metal type Listed in ascending order by part number. 1315 Preset... 16 Capillary Temp Range... 28-35 F BD1080 1318 Rotary... 18 Capillary Temp Range... 28-62 F (Adjustable) A45-1033 1325 Rotary...Bi Metal Positive... on and off Temp Range... 60-80 F (Adjustable) Twin Temp Bunkcontrol 1327 Cable... 30 Capillary Temp Range... 34-54 F (Adjustable)...Pull for Cold Hole Spacing...2-15/16 1328 Cable... 42 Capillary Temp Range... 30-62 F (Adjustable)...Pull for Heat Hole Spacing...2-15/16 540

Listed in ascending order by part number (continued). THERMOSTATIC NOTE: Thermostatic switches listed close at higher temperature and open at lower temperature. 1331 Preset... 24 Capillary Temp Range... 34-38 F Hole Spacing...2-1/8 1332 Preset... 24 Capillary Temp Range... 31-39 F Hole Spacing...2-1/4 Side mount 1333 Preset... 24 Capillary Temp Range... 34-44 F Hole Spacing...2-3/16 1334 Preset... 18 Capillary Temp Range... 24-36 F A45-1061; 9533N401 1335 Rotary... 27 Capillary Temp Range... 34-52 F (Adjustable) RD4172-0 1336 Rotary... 36 Capillary Temp Range... 34-52 F (Adjustable) RD4125-36 1337 Rotary... 72 Capillary Temp Range... 34-52 F (Adjustable) A10-6499 1340 Preset... 21 Capillary Temp Range... 31-40 F 9533-478 1341 Preset...31-1/2 Capillary Temp Range... 31-40 F BD1430 1342 Preset... 12 Capillary Temp Range... 31-39 F 9533N538 1343 Cable... 21 Capillary Temp Range... 40-31 F Hole Spacing...2-1/8 VOLVO GM OE# V1118416 1344 Preset Elect. Control Ford 40-Series Tractors OE# 82034877 1345 Preset... 12 Capillary Temp Range 30.5 F - 44.5 F WesternStar #30-899682 General Motors #3039429 1348 Rotary... 48 Capillary Temp Range... 34-52 F (Adjustable) A10-6495-00 1349 Preset... 30 Capillary Volvo 3093431, 9533N553 1351 Rotary... 36 Capillary Temp Range... 26 F-34 F Volvo/GM (Adjustable) 1354 Isuzu OE# 1-83579-283-0 1536 Ambient Thermostat Switch 11 Capillary Tube (Adjustable setting) Eaton #9533N383 Carrier Bus #AC201-500 1537A MCC Applications Preset (replaces obsolete lever type) Eaton #9533N559 541

WIRING COMPONENTS Wiring Components for Clutches, Relays and Switches Switch Pigtail 1019...1543 1038...1534 1043...1534 1050... 1055H 1055... 1055H 1056... 1055H 1150...1152 1151...1152 1250...1527 1251...1527 1252...1527 1260...1543 Switch Pigtail Switch Pigtail Switch Pigtail Switch Pigtail 1261...1543 1262...1543 1263...1543 1264...1543 1293...1548 1295... call 1310...1559 1396...1562 1397...1562 1400...1544K 1403...1559 1404...1559 1410...1526 1411...1530 1412...1530 1416...1564 1418...1562 1419...1526 1421...1564 1423...1564 1424...1564 1429...1564 1430...1526 1437...1546 1438...1546 1439...1546 1453...1564 1463...1564 1471...1546 1472...1546 1473...1561 1475...1561 1492...1564 1493...1564 1500...1524 1510...1524 1512...1526 1513...1526 1514...1546 1515...1546 1516...1526 1550...1525 1555...1525 1557...1561 1560...1525 1565...1525 1055H Blower Switch Harness (Fits 1050, 1055, 1056) 1152 Blower Switch Harness 5 term, conn. (Fits: 1150, 1151) A/C Industries OE# 201-902 1524 Binary Switch Harness, 2 wires (Fits: 1500, 1510) 1525 Trinary Switch Harness, 4 wires (Fits: 1550, 1555, 1560, 1565) 1526 Switch Harness Low Pressure UNIVERSAL (Fits: 1419, 1430, 1512, 1513, 1516) 1527 Bosch Mini-Relay Harness UNIVERSAL works on 4 or 5 prong relay (Fits: 1250, 1251, 1252) 1529 Clutch Coil Connector GM Compressor 90 with Diode 1530 FORD - Pressure Cycling Switch Harness (Fits: 1411, 1412) 1532 Clutch Coil Connector GM Vehicle with Sanden Compressor straight with diode 1534 FORD Blower Switch Harness (Fits: 1038,1043) 1535 FORD FS-6 Compressor Clutch Coil Connector 1540 UNIVERSAL - In Line Diode 1541 GM Clutch Coil Extension 1542 Weatherpack Clutch Coil Connector (mates with #1552) 1543 Bosch Mini-Relay Harness weatherproof, 5 wire (Fits: 1019, 1260, 1261, 1262, 1263, 1264) 1544K Pigtail Repair Kit for Navistar Sensor (Fits: 1400) 542

Listed in ascending order by part number (continued). WIRING COMPONENTS Wiring Components (continued) 1545 Sanden FLX7 Female Wiring Harness converts single wire to dual wire 1546 PACCAR Switch Connector - 2 wire (Fits: 1437,1438, 1439, 1471, 1472, 1514, 1515) 1547 GM High Blower Relay Pigtail 4 wire 1548 70 AMP Relay Connector (Fits: 1293 Relay) 1549 Clutch Coil Connector Female Metri-Pack Heavy Duty Blue Housing, 2 wire 1551 SD7H15 Clutch Coil Connector Metri-Pack 280 Heavy Duty Black Housing, 1 wire 1552 SD7H15 - FLX7 Adapter Black Connector to Male Bullet, 1 wire (mates with #1542) 1553 VOLVO Model 8044 Clutch Coil Connector White/Clear Housing, 1 wire 1554 Pigtail / Clutch Coil Ford Scroll Compressor 1556 CHEV/GMC - HR6, HT6,HU6 8mm pin to spade connector 1557F Sanden Deutsch Female connector pigtail 1557M Sanden Deutsch Male connector pigtail 1559 Pigtail for Pressure Switch (Fits: 1310, 1403, 1404) 1561 Pigtail for 3 wire Transducer (round) (Fits: 1473, 1475, 1557) 1562 Pigtail for Ford Cycling Switches Fits round switches w/2 terminal (Fits: 1396, 1397, 1418) 1563 Sanden Male Metri-Pack Connector Pigtail (Fits onto female Metri-Pack coil connectors) 543

WIRING COMPONENTS Wiring Components (continued) Sanden Male Metri-Pack Connector Pigtail fits onto Female Metri-Pack Coil Connectors. 1564 CHEV/GMC, International Low Pressure Switch Pigtail - 2 Wire (Fits: 1416, 1421, 1423, 1424, 1429, 1453, 1463, 1492, 1493) 1590 Clutch Pigtail Bullet and eyelet ends 1591 Clutch Pigtail Weatherpack and eyelet ends 1592 Clutch Pigtail Packard and eyelet ends 1593 Clutch Pigtail Packard MP280 and eyelet ends 1595 Sanden Clutch Pigtail Assortment Kit contains: Qty. P/N Description 2 ea...1545...sanden FLX7 2 ea...1553...volvo 2 ea...1590...bullet 1 ea...1591...weatherpack 2 ea...1592...packard 1 ea...1593...packard MP280 With these handy pigtails, you can adapt them to any 2 wire Sanden compressor clutch to match your original harness. Eliminates confusion on which wire to ground. 544

SOLENOID VALVES AN AIR OPERATED SOLENOID VALVE is an electronic control used to operate (engage & disengage) the air actuated engine fan clutch and/or radiator shutters on the vehicle. It can be plumbed to operate in either a normally open (N.O.) or normally closed (N.C.) position, depending upon the type of fan on the vehicle, and the specific inlet port used on the solenoid. See illustrations below to determine the correct inlet port. NORMALLY OPEN NORMALLY CLOSED TYPICAL PLUMBING For use on Kysor, Bendix For use on Horton N.C. Dry Air & Rockford N.O. fan drives fan drives 1 VENT 2 CLUTCH 3 VENT Clean Air to Fan Drive N.C. Solenoid Valve VENT Dry Air 3 SUPPLY PORT FILTER INSERTED HERE IF USED 2 CLUTCH 1 SUPPLY PORT FILTER INSERTED HERE IF USED Clean Air to Fan Drive N.O. Solenoid Valve VENT Air Sensing Switches and Solenoid Valves outlet 1655 Refrigerant Solenoid Liquid Line Applications 12v, #6 Male Inserrt O ring 2002 Air Solenoid Valve, 12v Normally Open or Closed 1/8 Thread inlet 2003 Air Solenoid Valve, 12v Normally Open or Closed 1/8 Thread 2004 Air Sensing Switch, NO Male 1/8-27 NPTF Closed between 20-30psi 2005 Air Sensing Switch, NC Male 1/8-27 NPTF Opens at 25psi 2006 Solenoid Valve, NO, 12 volt Continuous Duty 5/16-24 UNF Thrds, Single Pole, 3 Terminal 2007 Solenoid Valve, NO, 24 volt Continuous Duty 5/16-24 UNF Thrds, Single Pole, 3 Terminal 2008 Vacuum Solenoid ProAir OE# 11-000-024 2008H Harness for Vacuum Solenoid ProAir OE# 04-000-039 545

INDEX SENSORS & CONTROLS INDEX Sensors & Controls Fast Finder part no. page part no. page part no. page part no. page 8034100P...547 8034101P...547 8036034P... obsolete 8036036P... obsolete 8036037P... obsolete 8036041P... obsolete 8036043P... obsolete 8036056P... obsolete 8036070P...548 8036073P...548 8036078P...548 8036080P...548 8036087P...548 8036098P...548 8036100P... obsolete 8036101P... obsolete 8036103P...548 8036105P... obsolete 8036128P... obsolete 8036136P...ss 8036217P 8036137P... obsolete 8036140P... obsolete 8036150P... obsolete 8036151P... obsolete 8036152P... obsolete 8036154P... obsolete 8036156P... obsolete 8036158P... obsolete 8036160P... obsolete 8036186P...548 8036193P... obsolete 8036194P...547 8036217P... obsolete 8037018P...548 8037024P...548 8037028P...548 8037030P...548 8037032P...548 8037034P...548 8037036P... obsolete 8037037P...549 8037039P... obsolete 8037040P...549 8037041P... obsolete 8037044P...548 8037045P...548 8037048P...548 8037050P...548 8037053P...548 8037055P...548 8037058P...549 8037060P... obsolete 8037061P...549 8037082P...548 8037088P... obsolete 8037089P...548 8037090P... obsolete 8037093P...548 8037098P... obsolete 8037099P... obsolete 8037106P...548 8037107P... obsolete 8037108P... obsolete 8037111P... obsolete 8037113P...549 8037121P... obsolete 8037122P...549 8037126P...549 8037127P... obsolete 8037129P... obsolete 8037130P...549 8037131P...548 8037133P... obsolete 8037134P...548 8037135P... obsolete 8037136P... obsolete 8037137P...548 8037138P... obsolete 8037139P... obsolete 8037140P... obsolete 8037141P... obsolete 8037142P... obsolete 8037143P... obsolete 8037152P... obsolete 8037181P... obsolete 8039010P... obsolete 8039012P... obsolete 8039014P... obsolete 8039017P...549 8039019P...549 8039021P...549 8039023P...549 8039025P...549 8039026P... obsolete 8039027P... obsolete 8039029P... obsolete 8039030P... obsolete 8039031P... obsolete 8039032P... obsolete 8039034P...549 8039041P... obsolete 8039042P...549 8039043P... obsolete 8039044P... obsolete 8039045P... obsolete 8040011P... obsolete 8040015P...ss 8040250P 8040016P...ss 8040251P 8040017P...ss 8040252P 8040018P...ss 8040253P 8040024P...ss 8040212P 8040025P... obsolete 8040028P... obsolete 8040030P...ss 8040223P 8040033P...ss 8040224P 8040034P... obsolete 8040035P... obsolete 8040038P...ss 8040204P 8040049P...ss 8040225P 8040062P...ss 8040230P 8040064P...ss 8040231P 8040069P...ss 8040214P 8040077P... obsolete 8040078P...ss 8040234P 8040082P...551 8040086P...ss 8040235P 8040088P...551 8040091P...ss 8040215P 8040096P...ss 8040216P 8040097P...ss 8040255P 8040098P...ss 8040256P 8040099P...ss 8040257P 8040101P...ss 8040260P 8040102P... obsolete 8040103P...ss 8040262P 8040111P...ss 8040237P 8040112P...ss 8040238P 8040117P...ss 8040239P 8040134P... obsolete 8040135P...550 8040136P...550 8040137P...ss 8040243P 8040138P...ss 8040263P 8040139P...ss 8040264P 8040140P...ss 8040265P 8040141P... obsolete 8040142P...ss 8040245P 8040143P... obsolete 8040144P...ss 8040246P 8040145P... obsolete 8040146P... obsolete 8040157P...ss 8040268P 8040158P...ss 8040218P 8040160P... obsolete 8040163P... obsolete 8040164P...551 8040171P... obsolete 8040172P... obsolete 8040176P... obsolete 8040177P...550 8040178P...550 8040179P... obsolete 8040188P... obsolete 8040189P...550 8040194P...550 8040204P...550 8040214P... obsolete 8040215P... obsolete 8040216P... obsolete 8040218P... obsolete 8040222P... obsolete 8040223P... obsolete 8040224P... obsolete 8040225P...550 8040230P...551 8040231P...551 8040234P... obsolete 8040235P...551 8040237P...550 8040238P... obsolete 8040239P...550 8040243P... obsolete 8040244P... obsolete 8040245P...550 8040246P... obsolete 8040250P... obsolete 8040251P... obsolete 8040252P... obsolete 8040253P... obsolete 8040255P...550 8040256P... obsolete 8040257P... obsolete 8040260P...550 8040262P...550 8040263P... obsolete 8040264P... obsolete 8040265P... obsolete 8040267P... obsolete 8040268P...550 8040277P...550 8040281P...550 8040282P...550 8040283P...551 8040307P... obsolete 8040312P... obsolete 8040313P... obsolete 8040314P... obsolete 8040315P... obsolete 8040316P... obsolete 8040317P... obsolete 8040318P... obsolete 8040319P... obsolete 8040321P... obsolete 8042103P...551 8042105P...551 8042114P...551 8042138P...551 8042152P...551 8043012P... obsolete 8043013P... obsolete 8043014P... obsolete 8043015P... obsolete ACX-10...551 546

Typical Switch and Connector Styles INDEX SENSORS & CONTROLS BARE LEADS DEUTSCH Provides an air tight crimp. METRI-PACK Uses flat male blade and box female terminals. WEATHERPACK Uses round pin and round socket terminals. SINGLE POST TWO TERMINAL THREE TERMINAL Listed by switch part number series then by set point in ascending order. 8034 Series - COOLANT - LOW LEVEL PROBES SET POINT RESET HOUSING PART FUNCTION F Differential NORMALLY Thrd. Type NUMBER CONNECTOR TYPE - - - 1/4 NPT 8034101P single (post w/nut) - - - 3/8 NPT 8034100P single (post w/nut) 8036 Series - TEMPERATURE CONTROL Electrical Switches Dual and Single Function SET POINT RESET HOUSING PART FUNCTION F Differential NORMALLY Thrd. Type NUMBER CONNECTOR TYPE dual 172 F - 187 F closed 1/2 NPTF 8036217P Metripack (tower w/socket) dual 175 F - 200 F closed 1/2 NPTF 8036193P Weatherpack (shroud w/pin) dual 195 F - 210 F closed 1/2 NPTF 8036158P Metripack (tower w/socket) dual 200 F - 215 F open 1/2 NPTF 8036137P Weatherpack (shroud w/pin) single 060 F 7 +/- 2.5 F closed 1/2 NPTF 8036128P Metripack (tower w/socket) single 080 F 25 +/- 3 F closed 1/2 NPTF 8036043P Metripack (shroud w/pin) single 125 F 118 +/- 2 F closed 1/2 NPTF 8036194P Weatherpack (shroud w/pin) single 190 F 7 +/- 1.5 F open 1/2 NPTF 8036036P 3 wires single 195 F 7 +/- 1.5 F open 1/2 NPTF 8036037P 3 wires single 205 F 7 +/- 2 F open 1/2 NPTF 8036140P Weatherpack (shroud w/pin) single 205 F 7 +/- 1.5 F closed 1/2 NPTF 8036056P Weatherpack (shroud w/pin) single 205 F 7 +/- 1.5 F open 1/2 NPTF 8036041P 3 wires (continued) 547

INDEX SENSORS & CONTROLS Listed by switch part number series then by set point in ascending order. 8036 Series - TEMPERATURE CONTROL Electrical Switches (continued) Air, Single/Dual and Fan Timer SET POINT RESET HOUSING PART FUNCTION F Differential NORMALLY Thrd. Type NUMBER CONNECTOR TYPE air (sink) 125 F 7 +/- 1.5 F closed 1/2 NPTF 8036156P Deutsch (receptacle w/pin) air (sink) 150 F 7 +/- 1.5 F closed 1/2 NPTF 8036154P Deutsch (receptacle w/pin) air (sink) 150 F 7 +/- 1.5 F open 1/2 NPTF 8036151P Metripack (tower w/socket) air (source) 150 F 143 +/- 1.5 F closed 1/2 NPTF 8036186P Weatherpack (shroud w/pin) air (source) 150 F 7 +/- 1.5 F open 1/2 NPTF 8036152P Weatherpack (shroud w/pin) air (source) 190 F 7 +/- 1.5 F open 1/2 NPTF 8036098P Deutsch (plug w/socket) fan timer 195 F 188 F open 1/2 NPTF 8036100P Deutsch (plug w/socket) fan timer 200 F 193 F closed 1/2 NPTF 8036078P Weatherpack (shroud w/pin) fan timer 200 F 193 F open 1/2 NPTF 8036070P Weatherpack (tower w/socket) fan timer 200 F 193 F open 1/2 NPTF 8036101P Deutsch (plug w/socket) fan timer 205 F 198 F closed 1/2 NPTF 8036080P Weatherpack (shroud w/pin) fan timer 205 F 198 F closed 1/2 NPTF 8036087P Deutsch (receptacle w/pin) fan timer 205 F 198 F open 1/2 NPTF 8036073P Weatherpack (tower w/socket) fan timer 205 F 198 F open 1/2 NPTF 8036103P Deutsch (plug w/socket) fan timer 208.5 F 198 F open 1/2 NPTF 8036105P Deutsch (plug w/socket) Sink - switch wired between load and ground. Source - switch wired between power and load. 8037 Series - TEMPERATURE CONTROL Mechancial Switches 2, 3, and Spade Type Terminals SET POINT RESET HOUSING PART FUNCTION F Differential NORMALLY Thrd. Type NUMBER CONNECTOR TYPE mechanical 105 F 7 +/- 1.5 F open 1/2 NPTF 8037106P 2 terminal (8-32 screw thrd) mechanical 120 F 6-12 F open 1/2 NPTF 8037134P 2 terminal (8-32 screw thrd) mechanical 130 F 5-9 F open & closed 3/8 NPTF 8037089P 3 terminal (8-32 screw thrd) mechanical 130 F 5-9 F open & closed 3/8 NPTF 8037141P 3 terminal (8-32 screw thrd) mechanical 140 F 6-12 F closed 3/8 NPTF 8037142P 2 terminal (8-32 screw thrd) mechanical 150 F 6-12 F closed 3/8 NPTF 8037121P 2 terminal (8-32 screw thrd) mechanical 160 F 5-9 F open & closed 3/8 NPTF 8037090P 3 terminal (8-32 screw thrd) mechanical 165 F 6-12 F closed 1/2 NPTF 8037107P 2 terminal (8-32 screw thrd) mechanical 165 F 5-9 F open 1/2 NPTF 8037108P 2 terminal (8-32 screw thrd) mechanical 170 F 12-18 F open 3/8 NPTF 8037131P 2 terminal (8-32 screw thrd) mechanical 180 F 5-9 F open & closed 1/2 NPTF 8037044P 3 terminal (8-32 screw thrd) mechanical 185 F 5-9 F open & closed 3/8 NPTF 8037137P 3 terminal (8-32 screw thrd) mechanical 185 F 5-9 F open 1/2 NPTF 8037018P 2 terminal (8-32 screw thrd) mechanical 185 F 5-9 F open & closed 1/2 NPTF 8037045P 3 terminal (8-32 screw thrd) mechanical 190 F 5-9 F open & closed 1/2 NPTF 8037048P 3 terminal (8-32 screw thrd) mechanical 195 F 5-9 F open 3/8 NPTF 8037082P 2 terminal (8-32 screw thrd) mechanical 195 F 5-9 F open & closed 3/8 NPTF 8037093P 3 terminal (8-32 screw thrd) mechanical 195 F 5-9 F closed 1/2 NPTF 8037024P 2 terminal (8-32 screw thrd) mechanical 195 F 5-9 F open & closed 1/2 NPTF 8037050P 3 terminal (8-32 screw thrd) mechanical 200 F 5-9 F closed 1/2 NPTF 8037028P 2 terminal (8-32 screw thrd) mechanical 200 F 5-9 F open 1/2 NPTF 8037030P 2 terminal (8-32 screw thrd) mechanical 200 F 5-9 F open & closed 1/2 NPTF 8037053P 3 terminal (8-32 screw thrd) mechanical 205 F 5-9 F closed 1/2 NPTF 8037032P 2 terminal (8-32 screw thrd) mechanical 205 F 5-9 F open 1/2 NPTF 8037034P 2 terminal (8-32 screw thrd) mechanical 205 F 5-9 F open & closed 1/2 NPTF 8037055P 3 terminal (8-32 screw thrd) (continued) 548

Listed by switch part number series then by set point in ascending order. INDEX SENSORS & CONTROLS 8037 Series - TEMPERATURE CONTROL Mechancial Switches (continued) 2, 3, and Spade Type Terminals SET POINT RESET HOUSING PART FUNCTION F Differential NORMALLY Thrd. Type NUMBER CONNECTOR TYPE mechanical 208 F 5-9 F open 1/2 NPTF 8037135P 2 terminal (8-32 screw thrd) mechanical 210 F 5-9 F open 3/8 NPTF 8037138P 2 terminal (8-32 screw thrd) mechanical 210 F 5-9 F closed 1/2 NPTF 8037036P 2 terminal (8-32 screw thrd) mechanical 210 F 5-9 F open 1/2 NPTF 8037037P 2 terminal (8-32 screw thrd) mechanical 210 F 5-9 F open & closed 1/2 NPTF 8037058P 3 terminal (8-32 screw thrd) mechanical 215 F 5-9 F open & closed 3/8 NPTF 8037098P 3 terminal (8-32 screw thrd) mechanical 215 F 5-9 F closed 1/2 NPTF 8037039P 2 terminal (8-32 screw thrd) mechanical 215 F 5-9 F open & closed 1/2 NPTF 8037060P 3 terminal (8-32 screw thrd) mechanical 220 F 5-9 F open & closed 3/8 NPTF 8037099P 3 terminal (8-32 screw thrd) mechanical 220 F 5-9 F closed 1/2 NPTF 8037040P 2 terminal (8-32 screw thrd) mechanical 220 F 5-9 F open 1/2 NPTF 8037041P 2 terminal (8-32 screw thrd) mechanical 220 F 5-9 F open & closed 1/2 NPTF 8037061P 3 terminal (8-32 screw thrd) mechanical 225 F 5-9 F open 3/8 NPTF 8037122P 1/4 spade mechanical 225 F 214 F open 1/2 NPTF 8037113P 1/4 spade mechanical 225 F 5-9 F open & closed 1/2 NPTF 8037126P 3 terminal (8-32 screw thrd) mechanical 240 F 7-15 F open & closed 3/8 NPTF 8037127P 3 terminal (8-32 screw thrd) mechanical 250 F 7-15 F open 1/2 NPTF 8037111P 2 terminal (8-32 screw thrd) mechanical 255 F 5-9 F open & closed 3/8 NPTF 8037181P 3 terminal (8-32 screw thrd) mechanical 290 F 270 F closed 3/8 NPTF 8037130P 2 terminal (8-32 screw thrd) 8039 Series - TEMPERATURE CONTROL Mechancial Switches Single Post Terminal SET POINT HOUSING PART FUNCTION f reset NORMALLY Thrd. Type NUMBER CONNECTOR TYPE mechanical 175 F 165 F closed 3/8 NPTF 8039030P 1 post (8-32 screw thrd) mechanical 190 F 180 F closed 1/2 NPTF 8039010P 1 post (8-32 screw thrd) mechanical 200 F 190 F closed 3/8 NPTF 8039031P 1 post (8-32 screw thrd) mechanical 200 F 190 F open 3/8 NPTF 8039032P 1 post (8-32 screw thrd) mechanical 210 F 200 F open 3/8 NPTF 8039034P 1 post (8-32 screw thrd) mechanical 210 F 200 F closed 1/2 NPTF 8039012P 1 post (8-32 screw thrd) mechanical 210 F 200 F open 1/2 NPTF 8039014P 1 post (8-32 screw thrd) mechanical 215 F 205 F closed 1/2 NPTF 8039017P 1 post (8-32 screw thrd) mechanical 215 F 205 F open 1/2 NPTF 8039019P 1 post (8-32 screw thrd) mechanical 220 F 210 F closed 1/2 NPTF 8039021P 1 post (8-32 screw thrd) mechanical 220 F 210 F open 1/2 NPTF 8039023P 1 post (8-32 screw thrd) mechanical 225 F 210 F open 3/8 NPTF 8039041P 1 post (8-32 screw thrd) mechanical 225 F 210 F open 1/2 NPTF 8039025P 1 post (8-32 screw thrd) mechanical 230 F 215 F open 3/8 NPTF 8039042P 1 post (8-32 screw thrd) mechanical 230 F 215 F open 1/2 NPTF 8039026P 1 post (8-32 screw thrd) mechanical 235 F 220 F open 1/2 NPTF 8039027P 1 post (8-32 screw thrd) mechanical 250 F 230 F open 3/8 NPTF 8039045P 1 post (8-32 screw thrd) mechanical 265 F 240 F open 3/8 NPTF 8039043P 1 post (8-32 screw thrd) mechanical 290 F 260 F closed 3/8 NPTF 8039044P 1 post (8-32 screw thrd) mechanical 300 F 270 F open 1/2 NPTF 8039029P 1 post (8-32 screw thrd) (continued) 549

INDEX SENSORS & CONTROLS Listed by switch part number series then by set point in ascending order. 8040 Series - PRESSURE Air, Fuel, Oil SET POINT RESET HOUSING PART FUNCTION (psi) (psi) NORMALLY Thrd. Type NUMBER CONNECTOR TYPE air fuel oil 009 007 open & closed 1/4 NPTF 8040262P Weatherpack (shroud w/pin) air fuel oil 014 006 closed 1/4 NPTF 8040224P Metripack (tower w/socket) air fuel oil 014 008 open & closed 1/8 NPTF 8040257P Weatherpack (shroud w/pin) air fuel oil 015 006 open & closed 1/8 NPTF 8040250P bare wire air fuel oil 015 006 open & closed 1/8 NPTF 8040265P bare wire air fuel oil 015 007 open 1/8 NPTF 8040218P - air fuel oil 016 008 open & closed 1/8 NPTF 8040263P Weatherpack (tower w/socket) air fuel oil 018 010 closed 1/4 NPTF 8040223P Weatherpack (shroud w/pin) air fuel oil 018 010 open & closed 1/4 NPTF 8040260P Weatherpack (shroud w/pin) air fuel oil 025 015 open & closed 1/8 NPTF 8040251P bare wire air fuel oil 025 015 open & closed 1/8 NPTF 8040268P - air fuel oil 055 040 closed 1/8 NPTF 8040246P bare wire air fuel oil 060 050 open 1/8 NPTF 8040215P Metripack (tower w/socket) air fuel oil 060 050 open 1/8 NPTF 8040216P Weatherpack (shroud w/pin) air fuel oil 070 065 open & closed 1/8 NPTF 8040255P Weatherpack (shroud w/pin) air fuel oil 075 060 open & closed 1/8 NPTF 8040252P bare wire air fuel oil 075 065 closed 1/4 NPTF 8040237P Metripack (tower w/socket) air fuel oil 085 075 closed 1/4 NPTF 8040238P Metripack (tower w/socket) air fuel oil 100 085 open & closed 1/8 NPTF 8040256P Weatherpack (shroud w/pin) air fuel oil 145 120 open & closed 1/8 NPTF 8040253P bare wire air fuel oil 145 120 open & closed 1/8 NPTF 8040264P bare wire air fuel oil 150 120 closed 1/8 NPTF 8040245P bare wire 8040 Series - HIGH PRESSURE SET POINT RESET HOUSING PART FUNCTION (psi) (psi) NORMALLY Thrd. Type NUMBER CONNECTOR TYPE high, APAds 300 260 closed M10 Fem 8040177P Metripack (tower w/socket) high, R12 310 220 closed 1/4 Fem 8040225P Weatherpack (shroud w/pin) high 325 275 closed M10 Fem 8040239P Metripack (tower w/socket) high 325 275 closed M10 Fem 8040277P Metripack (tower w/socket) high 325 275 closed M10 Fem 8040312P Weatherpack (tower w/socket) high, R12 335 245 closed 1/4 Fem 8040316P Metripack (tower w/socket) high, APAds 335 245 closed M10 Fem 8040317P Metripack (tower w/socket) high, APAds 350 300 closed 1/4 Fem 8040171P Weatherpack (tower w/socket) high, APAds 350 275 closed M10 Fem 8040172P Weatherpack (tower w/socket) 8040 Series - LOW PRESSURE SET POINT RESET HOUSING PART FUNCTION (psi) (psi) NORMALLY Thrd. Type NUMBER CONNECTOR TYPE low, R12 015 004 open 1/4 Fem 8040178P Weatherpack (shroud w/pin) low, APAds 034 008 closed M12 Fem 8040136P Metripack (shroud w/pin) low, APAds 034 008 closed M12 Fem 8040189P Metripack (shroud w/pin) low, R12 034 010 open 1/4 Fem 8040204P Weatherpack (shroud w/pin) low, R134a 034 010 open M12 Fem 8040281P Metripack (shroud w/pin) low, R12 034 010 open 1/4 Fem 8040319P Metripack (shroud w/pin) low, R134a 034 010 open M12 Fem 8040321P Weatherpack (shroud w/pin) low, R134a 040 032 open M10 Fem 8040282P Metripack (tower w/socket) low, APAds 047 025 closed M12 Fem 8040194P Weatherpack (shroud w/pin) low, CCOT 047 025 open M12 Fem 8040318P Weatherpack (shroud w/pin) 550

Listed by switch part number series then by set point in ascending order. INDEX SENSORS & CONTROLS 8040 Series - FAN TRIGGER (Turns on engine cooling fan - mounted on pressure side of compressor) SET POINT RESET HOUSING PART FUNCTION (psi) (psi) NORMALLY Thrd. Type NUMBER CONNECTOR TYPE a/c fan, R12 250 210 closed 1/4 Fem 8040230P Weatherpack (tower w/socket) a/c fan, R12 250 210 closed 1/4 Fem 8040234P Deutsch (receptacle w/pin) a/c fan, R12 275 235 closed 1/4 Fem 8040082P Deutsch (receptacle w/pin) a/c fan 275 235 open 1/4 Fem 8040214P Weatherpack (shroud w/pin) a/c fan, R12 275 235 closed 1/4 Fem 8040231P Weatherpack (tower w/socket) a/c fan 275 235 closed M10 Fem 8040235P Deutsch (receptacle w/pin) a/c fan, R12 275 235 closed 1/4 Fem 8040243P Weatherpack (shroud w/pin) a/c fan 275 235 closed M10 Fem 8040283P Deutsch (receptacle w/pin) a/c fan 275 235 closed M10 Fem 8040314P Weatherpack (tower w/socket) a/c fan 275 235 open M10 Fem 8040315P Weatherpack (tower w/socket) a/c fan 300 260 closed M10 Fem 8040088P Deutsch (receptacle w/pin) a/c fan, R12 300 260 closed 1/4 Fem 8040134P Deutsch (receptacle w/pin) a/c fan 300 260 closed M10 Fem 8040164P Weatherpack (tower w/socket) a/c fan, R12 300 260 closed 1/4 Fem 8040307P Weatherpack (tower w/socket) a/c fan 300 260 open 1/4 Fem 8040313P Weatherpack (tower w/socket) 8042 Series - APAds A/C CONTROL MODULE SERVICE PARTS MODULE APAds CM-812 APAds CM-813 Std 3 minute fan (Deutsch connectors, grey) APAds CM-813 ECM fan ctrl (Deutsch connectors, grey) APAds CM-814 Std 3 min fan OE (Metri-pack 10 pin connector, black) PART NUMBER 8042114P 8042103P 8042105P 8042152P APAds CM-820 Std 8042138P shown 8042114P A/C COMPRESSOR ASSY Life Extender ACX-10 PART NUMBER Reduce your maintenance costs and downtime. Easy to install, economical smart protection 1596 Prevents rapid cycling under harmful high or low pressure conditions. A Detection and Protection System The ACX-10 A/C Life Extender detects pressure that s too high or low, and too much or too little voltage. Then, it protects expensive system components from being damaged, and saves you maintenance costs and downtime. Pressure Protection When the ACX-10 detects persistent high or low system pressure, it disengages the A/C clutch until the pressure returns to the normal, safe operating range. Voltage Protection The ACX-10 detects over- and under-voltage conditions, and temporarily disengages the A/C clutch until the voltage returns to the normal, safe range. Starter Motor Protection The ACX-10 unburdens the starter motor and extends its life by delaying the A/C clutch engagement until 15 seconds after ignition. 551