A self-contained system, the 7100 Series ARC valve has a pressure reducing trim and is in-line repairable.

Similar documents
A self-contained system, the 7100 Series ARC valve has a pressure reducing trim and is in-line repairable.

YARWAY ARC PUMP PROTECTION VALVES (AUTOMATIC RECIRCULATION) SERIES 9200, 9100, 5300 AND BPR

Double door, spring loaded, wafer check valve designed to protect your gas or liquid piping systems.

Anderson Greenwood Series 5100 Pilot Operated Pressure Relief Valves

310 Wafer high performance butterfly valve 312 Lugged high performance butterfly valve

Direct contact, metal-to-metal seating, make the gate valve ideal for most shut-off applications. Class 800 ANSI.

61W - Wafer style resilient seated butterfly valves 61L - Lugged style resilient seated butterfly valves

Installation and maintenance instructions

Cast Iron Liquid Relief Valves

ANDERSON GREENWOOD. Flow Control. Anderson Greenwood Tank and Equipment Blanketing Systems. Pad Valves. De-Pad Valves. Total Flow Control Solutions

Kunkle Safety and Relief Products. Series 6000

Crosby Series 800 and 900 OMNI-TRIM Pressure Relief Valves. Flow Control

Double block and bleed style stainless steel butterfly valve sizes 1" to 6" [25 mm to 150 mm]. F250D for imperial tubing F251D for metric tubing

Anderson Greenwood MLCP. Modulating Large Capacity Pilot Valve

Crosby Style JQ Pressure Relief Device. Flow Control

Automatic Recirculation Valves One Step Centrifugal Pump Minimum Flow Protection

Crosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure.

Kunkle Safety and Relief Products

Yarway 7100 Series ARC Valve non-filtered design Installation and maintenance instructions

Keystone Hygienic Products Figure 267J/268J (Reversible) Single Seal Piston Valves

Jordan Control Valve Series

78200/18200 Series LINCOLNLOG Valves Anti-cavitation High Pressure Control Valves

* Contact your sales representative for compliance to NACE MR or later requirements.

* Contact your sales representative for compliance to NACE MR or later requirements.

Prince Wafer Swing Check Valves Sizes 2 thru 36

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

Fisher CAV4 Control Valve

41005 Series Control Valves. Specification Data CH /10

ANDERSON GREENWOOD. Before installation these instructions must be fully read and understood.

Cash Valve. Type G-60. High Capacity Pressure Regulator. Flow Control. Issued - February 2001 CAVMC-0511-US-0609 ISO 9001 Certified

304C. Valve Group. Series Farris Engineering Pressure Relief Valves

Spring return pneumatic quarter-turn actuator for spring end torques to 685,500 lb.in.

Spring loaded Thermal Relief Safety Valves, manufacturers standard Medium and high pressure

Fisher CAV4 Control Valve

SAFETY relief VALVE SERIES # 006 DESIGN FEATURES HARSHAD ENGINEERING WORKS HARSHAD ENGINEERING WORKS TECHNICAL DATA : ISO 9001 CERTIFIED COMPANY

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

Yarway Hy-Drop Throttling valve

Fisher CAV4 Control Valve

SV80H Safety and Relief Valves

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation.

TRANSMITTER ATTACHES TO THIS SURFACE

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34

K-LOK Installation, Operation, Maintenance and Troubleshooting

Cash Valve. A Series. Pressure Regulators. Flow Control. Issued - January 2001 CAVMC-0508-US-0609 ISO 9001 Certified

Automatic Recirculation Valves PUMPENSCHUTZVENTILE

TECHNICAL BULLETIN. Valtek Multi-Z Anti-Cavitation Control Valve. Experience In Motion. Valtek Series Multi-Z FCD VLENTB /10

A comprehensive range of pneumatic actuators, providing compact, reliable and economical powered operation for all types of quarter-turn valves.

Yarway Narvik Model 37 and 47 Cryogenic injector

Butterfly Control Valve

Standard Duty A.T.-Temp Desuperheater for cryogenic processes

SERIES VARISTEP CONTROL VALVES

Paramax Series Control Ball Valve. Specification Data CM6004 7/97

High Capacity Direct Operated Pressure Reducing Valve. Features

Fisher 8532 High-Performance Butterfly Valve

Fisher 8532 High-Performance Butterfly Valve

21000 Series. Masoneilan* Complete Line of Rugged, Top Guided, Globe Valves with Lo-dB* and Anti-Cavitation Capabilities

Keystone Figures 310/312 K-LOK Butterfly Valves

DBOY Series Pneumatic Control Valve

High CATALOG. Efficiency. Pilot Operated Safety Valves Series 810 Pop Action Series 820 Modulate Action. The-Safety-Valve.com

310 Wafer high performance butterfly valve 312 Lugged high performance butterfly valve

494C. Pilot Operated Pressure Relief Valves. Series Pilot Operated Pressure Relief Valves. Farris Engineering Pressure Relief Valves

Honeywell EN REV. 2 09/2014 Page 1 of 10 Specification

HIGH PERFORMANCE BUTTERFLY VALVE MODEL HP300 SERIES

CONTROL VALVE STANDARD SPECIFICATION

KEYSTONE FIGURES 310/312 K-LOK BUTTERFLY VALVES

CROSBY J-SERIES DIRECT SPRING PRESSURE RELIEF VALVES

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Safety and Relief Valves Product Overview

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES

P3M5S, P4M5S, P6M5S 5-VALVE SOFT SEAT MANIFOLD

V A L V E S & M E A S U R E M E N T. TOM WHEATLEY Piston Check Valves TOM WHEATLEY

YARWAY THROTTLING VALVES HY-DROP MODEL 5817/ 5827

Series Pilot Operated Pressure Relief Valves 0810C

P3M3H, P6M3H 3-VALVE HARD SEAT MANIFOLD

Installation, Operation and Maintenance Instructions

Model 788DVC DIGITAL CONTROL VALVES

Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation.

21000 Series Control Valves

Product overview. Technical data

FloCheck is a precision engineered, twin plate check valve suitable for product or service lines, wherever non-return protection is required.

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

TABLE OF CONTENTS INDRODUCTION

CROSBY STYLE JB PRESSURE RELIEF VALVE

Series A angle pattern control valves

MODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL

NARVIK-YARWAY. High Pressure Level Gauges, Model: 17

Fisher DFA Variable Geometry Desuperheater

Direct contact, metal-to-metal seating, make the gate valve ideal for most shutoff applications. Class 800 ANSI.

Product Description. Product Description. Materials Series 810, 820 Main Valve

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

PRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES

BERMAD Waterworks. 800 Series. Technical Specifications Metric

Series 800 AWWA Butterfly Valves

Multi Orifice Nozzle. Valve (MON) R Series Control Valves R2 R3 R4 R6 R8

MK508UBS Series. Back Pressure Regulator MK508UBS. Threaded or Flanged Connections Carbon Steel, Stainless Steel & Alloy Construction.

Solutions beyond products...

Bolted Bonnet Valves. (BL Series) Cast Steel. Cast Steel Bolted Bonnet Valves - BL Series

Yarway Narvik Desuperheater Model 18/54 and 28/64 Heavy Duty

Transcription:

A self-contained system, the 7100 Series ARC has a pressure reducing trim and is in-line repairable. General Description The 7100 Series ARC Valve has been specifically designed and manufactured to meet the demands and operating philosophies of today s high pressure centrifugal pumps. Many power plants are now operating under peaking or throttled conditions, which in turn requires the pumps to operate at less than their optimal design and performance levels. As a result, they are subject to serious damage from hydraulic, mechanical and/or thermal abnormalities. The 7100 Series ARC provides the most economical and reliable system to protect pumps from the dangers of low and/or reverse flow. It combines the functions of a check, flow sensing device, minimum flow control and pressure letdown into a single. The ARC requires no external use of power and installs easily with only three connections. By eliminating at least seven major interdependent components, that ordinarily would be necessary to provide this protection, we have not only simplified the system, but made it much more reliable. Our quest for ensured pump flow protection does not, however, end at just providing the hardware. We analyze the complete pumping system and piping. Very often the application s fluid hydraulics and dynamics compromise the effectiveness of the protection system. A thorough analysis of conditions up and downstream of both the pump and ARC will provide us with solutions to reliable protection... things such as 1) proper pressure throughout the complete bypass piping to prevent any level of flashing or cavitation; (a condition that is prevalent in all pressure breakdown systems); 2) improved bypass manifold arrangements; 3) good piping layouts that promote stable operation; 4) stable and reliable interaction of pump and at less than optimal conditions of operation. The 7100 Series ARC is made to operate in a low flow condition for extended periods without damage to the or bypass piping system. The need is no longer just for emergency, short duration shut down, but for extended operation at low flows. Our check and bypass/pressure letdown elements are specifically designed to operate under these difficult conditions. There is no need for an auxiliary manual by-pass system which only serves to negate the advantage of an automatic system. The design of the 7100 Series ARC is the result of 27 years of experience and over nine thousand ARC s in service. And to help ensure every works properly, functional tests are performed and the s are then certified for the application. Flow Control Yarway is either a trademark or registered trademark of Tyco International Services AG or its affiliates in the United States and/or other countries. All other brand names, product names, or trademarks belong to their respective holders. -US-0910

7100 Series ARC (ANSI Class 900-1500) Features and Benefits Self-contained provides the functions of: Check, flow sensing element, bypass flow control and multi stage pressure letdown device. Simplifies the system. Reduces cost of Engineering, Administration, Installation and Maintenance of complex, conventional flow control and instrument systems. Eliminates requirement for external source of power and/or instrument signals. One replaces seven interdependent components Eliminates multi vendor responsibility and coordination. Enhances system reliability. Patented bypass flow control and pressure letdown system Helps ensure fail safe operation and pump flow protection. Eliminates cavitation, flashing, choked flow and/or damage in bypass line. Complete in-line accessibility Allows for adjustment, inspection and/or maintenance of all internals without removing the from the line or disrupting any piping. Field adjustability Enables user to change main flow, bypass flow and switch point. Accommodates changes in pump operation. True bypass flow modulation Help ensure proper minimum pump flow. Provides a smooth transition from main flow to bypass flow, thus eliminating piping shock. Conserves energy. Valves are completely functional tested Valve is certified correct for its application. Helps ensure reliable performance from every. One Valve Four Functions Check prevents reverse flow. Instrumentation flow sensing and bypass activation. flow control helps ensure minimum pump flow. Pressure letdown reduces pressure of fluid returning to its sources. activation and switchpoint adjustment Check prevents reverse flow back into pump Flow sensing element Outlet Inlet Vortex flow development flow control Separate tight shut off sealing surfaces Multi-stage pressure letdown Piloted bypass piston positioning External bypass flow adjustment 2

ARC system simplifies installation: One piece to be installed Only three connections Eliminates at least seven welds No electric or air supply lines to install No instrumentation hook up or calibration No special piping requirements ARC system increases reliability: Specifically designed for fail safe operation Fewer moving parts cuts down failure potential No external source of power to jeopardize operation Single vendor responsibility Control Loop System To process Multiple pressurereducing orifice Gate or control Recirculation control Gate (optional) Check Gate (optional) Four-way air solenoid Flow meter Pump FIC Storage vessel Sensing orifice ARC system eliminates: Sensing orifice Instrumentation Air/electric supply Check flow control Pressure letdown ARC reduces maintenance: All internals are in-line accessible Wear points such as levers and linkages are eliminated No external source of power required Actuators and controls are eliminated No calibration required No dynamic seals or packing Yarway System To process Gate or control Check Automatic recirculation Remote back pressure regulator (optional) element Pump Storage vessel 3

7100 Series Butt Weld Ends B A H J D G Min. clearance to remove bonnet/disc assembly assembly Valve inlet inlet C discharge connection far side E F Min. clearanceto remove to remove cascade cascade bushing bushing 7100 Series Flanged Ends B A H J D G Min. clearance to remove bonnet/disc assembly Valve inlet C discharge connection far side E F Min. clearance to remove to remove cascade cascade bushing bushing RF flanged end per ANSI B16.5 B16/5 Dimensions and Weights for Class 900 and 1500 Valves, inches [mm] Nominal Weight Valve Butt Weld Flanged Size Conn. A B C D E F G H J lb. (kg) 3" 1 1 /2" 20 1 /2 8 11 /16 11 3 /32 8 10 18 12 13 1 /2 7 1 /2 260 360 [80] [40] [520.7] [220.7] [35.7] [203.2] [254] [457.2] [304.8] [342.9] [190.5] (118) (163) 4" 2" 25 1 /2 11 1 3 /4 11 14 24 15 17 9 1 /2 500 640 [100] [50] [647.7] [279.4] [44.5] [279.4] [355.6] [609.6] [381] [431.8] [241.3] (227) (290) 6" 2 1 /2" 36 15 5 /8 2 3 /8 14 20 34 21 22 1 /2 12 1450 1725 [150] [65] [914.4] [396.9] [60.3] [355.6] [508] [893.6] [533.4] [571.5] [304.8] (658) (782) 8" 3" 42 18 1 /4 3 18 24 41 28 28 15 2650 3150 [200] [80] [1066.8] [463.6] [76.2] [457.2] [609.6] [1041.4] [711.2] [711.2] [381] (1202) (1429) Dimensions are the same for Flanged and Butt Weld end s. Available in DIN and JIS end connections. Valve size and bypass connection in., [DN]; Dimensions in., [mm]; Weight lb., (kg). 4

Sizing Guide Valve Size 3" 4" 6" 8" Main Flow Range 120-400 GPM 300-715 GPM 600-1575 GPM 700-2675 GPM 27-91 M 3 /hr 68-162 M 3 /hr 136-358 M 3 /hr 159-608 M 3 /hr C v Range 2 Stage 1 0.3-0.4 (0.26-3.5K v ) 1.0-11.5 (0.87-9.9K v ) 3.0-24.0 (2.6-20.8K v ) 5.0-40.0 (4.3-34.6K v ) 4 Stage 2 0.2-2.0 (0.17-1.7K v ) 0.8-8.0 (0.69-6.9K v ) 2.0-17.0 (1.7-14.7K v ) 4.0-28.0 (3.5-24.3K v ) 1) For DPs up to 1500 psid 2) For DPs between 1500 and 3000 psid Pressure and Temperature Selector Guide Model No. Butt Weld 7105 7107 Flanged 7106 7108 ANSI Pressure Class 900 1500 Temperature Working Pressures (psig) 100 F 2220 3705 200 F 2025 3375 300 F 1970 3280 400 F 1900 3170 500 F 1795 2995 Notes: 1. Determine pressure class and model no. by consulting pressure and temperature selector guide above. 2. To select size: refer to ARC sizing guide above. Be sure normal and maximum pump operation flows fall within the flow range noted for the given. 3. Verify that bypass capacity meets minimum pump flow requirement: Q min Calculate C v : = DP S.G. Q min = Minimum pump flow DP Pump discharge pressure = { minus bypass line pressure S.G. = Specific gravity of fluid pumped Installation Valve Installation (common line to receiver) Receiver vessel Piping Installation (separate line to receiver) Receiver vessel outlet Recommended location of back pressure orifice or back pressure regulator when specified Block Check outlet Check Long radius type pipe bends 5

50, 49 7 33 4 8 6 See detail Detail A 17 3 2 1 Per ANSI B16.5 5 51 51 46 See detail Detail BB See sectional Detail Detail C for C pilot for pilot representation representation 32 52 48 30 47 18 19 59 15 13 58 12 27 53 26 29 51 31 14 22 11 10 9 7 56 55 57 34 23 Detail A Detail B 6

Notes: 1. Recommended spare parts for service inspection. 2. Recommended spare parts for service overhaul. 3. Optional on body. Detail C 38 38 44 44 42 42 43 43 22 22 19 19 39 39 28 28 36 36 41 41 48 48 45 45 27 27 35 35 60 60 Parts and Materials Item Part Material Specification 1 Body Cast Steel ASME SA216 Gr. WCB 2 Bonnet Cast Steel DIN 17245 Material No.1.0619 GS-C-25 3 Pipe Plug SS Type 316 4 Segmented ASME A487 SS Retaining Ring Gr. CA6NMCL. A 5 Segmented Ring Retainer SS Type 17-7 PH 6 Spring SS Type 17-7 PH 7 Disc SS ASME SA351 Gr. CF8M 8 Orifice Snubber SS Type 316 9 Retaining Ring SS PH 15-7 Mo 10 Washer SS ASTM A276-XM19 11 1,2 Seal Assembly Elastomer TFE and SS 12 Disc Lower SS ASTM A479 Guide Bushing Type XM19 13 Switch Point Adjustment Screw SS ASTM A582 Type 416 14 Switch Point ASTM A582 SS Adj. Screw Bushing Type 416 15 Spring Pin (Bushing) SS Type 18-8 17 Flow Element SS Type 316 18 2 Bushing SS ASTM A747 Gr. CB7 Cu-1 19 2 Piston SS ASME SA479 Type 410 22 1,2 Pilot Tube SS and Stellite ASME SA564 Gr. 630 w/ Stellite 6 seat 23 1,2 Metering Orifice SS Type 431 26 Spring Pin SS Type 18-8 27 Stroke Adjustment Screw SS ASME SA564 Gr. 630 28 Spring Pin SS Type 18-8 29 Lock Nut SS Type 18-8 Item Part Material Specification 30 Cover CS ASTM A105 31 Stud Alloy Steel ASME SA193 Gr. B7 32 Nut Alloy Steel ASME SA194 Gr. 2H 33 1,2 O-ring Elastomer TFE Propylene 34 1,2 O-ring Elastomer TFE Propylene 35 1,2 O-ring Elastomer TFE Propylene 36 1,2 O-ring Elastomer TFE Propylene 38 1,2 O-ring Elastomer TFE Propylene 39 1,2 O-ring Elastomer TFE Propylene 41 1,2 Seal Assembly Elastomer TFE Propylene 42 1,2 Anti-Rotation Key SS ASTM A276 Gr. 440C 43 1,2 Retainer (O-ring) Elastomer TFE Propylene 44 1,2 Pilot Valve Seat SS Type 431 45 2 Pilot Tube Seal Plug SS Type 431 46 1,2 O-ring Elastomer TFE Propylene 46a 1,2 Back-up Ring Carbon/graphite Elastomer (3" Valve Only) reinforced PTFE 47 1,2 O-ring Elastomer TFE Propylene 48 1,2 O-ring Elastomer TFE Propylene 49 Drive Screws SS Type 18-8 50 Nameplate SS Type 302 51 3 Pipe Plug (Pressure Tap) SS Type 316 52 Stud Alloy Steel ASME SA 193 Gr. B7 53 Stroke Adjustment Screw Cover CS ASTM A105 55 1,2 Filter Gasket, Lower Elastomer TFE Propylene 56 1,2 Filter Gasket, Upper Gasket Reinforced Teflon 57 Filter Housing and Screen Assembly SS Type 316 58 Retaining Ring SS Type 17-7 PH 59 1,2 Seal Assembly Elastomer TFE Propylene 60 2 Retaining Ring SS PH 15-7 Mo 7

Back Pressure Regulator (BPR) In high pressure pumping applications the system often does not provide adequate pressure in the bypass line to prevent cavitation or flashing. Either of these conditions is undesirable in that it can cause damage to both s and the pipe system or cause a reduction in flow beyond the minimum desired, jeopardizing the pump protection system. All PRVs will experience a velocity induced recovery effect which will limit the amount of pressure drop a can take and cause a reduction in flow capacity. The requirement of back pressure is generic to all pressure reducing applications. Pressure reduction even by multiple stage cascading such as in the 7100 Series ARC can minimize the requirement, however no design will redefine a fluid s physical properties. This becomes especially important in modulating systems. A fixed orifice will not provide the proper back pressure at all flow levels. As the flow in the bypass line is reduced, the orifice becomes less effective. Proper system design should be used to optimize pressure reduction and consider all fluid dynamic effects downstream of any pressure reducing device. When adequate back pressure is not available downstream of a pressure reducing, vapor bubbles will form in the zone just downstream of the last stage control surface. This zone is defined as the Vena Contracta and represents the point of highest fluid velocity and lowest pressure. The potential for 1) damage to downstream piping components and 2) flow reduction exists from this point. When line pressure remains below the fluid vapor pressure, any existing bubbles will remain and expand as piping friction further reduces line pressure. This can be defined as a FLASHING CONDITION and is characterized by a polished appearance on affected surfaces. When the line pressure drops below the fluid vapor pressure and then recovers, any entrapped vapor bubbles will collapse (implode). This is defined as a CAVITATING CONDITION and is characterized by a cinder like appearance on affected surfaces. The resolution of either condition is best addressed by eliminating vapor formation. This can be ensured by the provision of adequate back pressure. The Backpressure Factor is key to reliable system operation and must not be ignored in piping design considerations. As such we feel it is the obligation of a responsible Automatic Recirculation Control Valve manufacturer to analyze the system needs and supply a Back Pressure Regulator (BPR) when it is warranted by the laws of fluid dynamics. For on/off systems this could be a simple orifice, but for modulating conditions it must be a device like the BPR noted herein. Flanged body BPR illustrated (installed between flanges). Wafer BPR is also available. Yarway 7100 ARC Valve Inlet outlet Check Flow Back pressure regulator 8

Back Pressure Regulator (BPR) Wafer BPR 3 /4" to 6" Remote Mounted Flange BPR 1 1 /2" to 10" 98 10 2 7 5 12, 13 1 2 7 10 11 4 3 9 Flow Flow ØA øa 6 1 12 5 8 13 B 11 6 3 4 9 C Parts and Materials Item Part Material 1 Body ASME SA105 2 Seat ASTM A747-CB7Cu-1 with Heat Treatment 3 Plunger Guide ASTM A276-S21800 (Nitronic 60 Bar) 4 O-ring TFE/P (Fluoraz 799) 5 Plunger AISI 431 Stainless Steel with Heat Treatment 6 Spring Retainer AISI 304 Stainless Steel 7 Spring ASTM A564 Type 631 (17-7 PH) H-900 Heat Treatment 8 Energized U Cup Seal Filled TFE 9 Retaining Ring AISI 304 Stainless Steel 10 Nameplate AISI 300 Series Stainless Steel 11 Drive Screw Stainless Steel 12 Spacer A269-304 13 Spiral Ring Inconel X-750 Dimensions and Weights Dimensions, in. [mm] Wafer BPR A B Flanged C Approx. Weight Size +/- 1 /16" [1.6] +/- 1 /16" [1.6] +/- 1 /16" [1.6] lb. (kg) 3/4" 1 1 /6 [42.9] 4 [101.6] N/A 5 (2.3) 1 1 /2" 2 7 /8 [73.0] 2 7 /8 [73.0] 6 [152.4] 5 (2.3) 2" 3 5 /8 [92.1] 3 3 /8 [85.7] 6 [152.4] 8 (3.6) 3" 5 [127.0] 4 5 /8 [117.5] 8 [203.2] 21 (9.5) 4" 6 3 /16 [157.2] 5 3 /4 [146.0] 12 [304.8] 40 (18.1) 6" 8 1 /2 [215.9] 7 1 /2 [190.5] 17 [431.8] 96 (43.5) For Flanged 8" and 10", contact your sales representative. Parts and Materials Item Part Material 1 Body ASME SA105 2 Seat ASTM A747-CB7Cu-1 with Heat Treatment 3 Plunger Guide ASME SA564 Type 630 (17-4 PH) H-900 Heat Treatment 4 Energized U Cup Seal Filled TFE 5 Plunger ASTM A479-431 Stainless Steel with Heat Treatment 6 Spring ASTM A564 Type 631 (17-7 PH) H-900 Heat Treatment 7 Spring Retainer AISI 304 Stainless Steel 8 Spiral Ring AISI 302 9 Flow Conditioner ASME SA747-CB7Cu-1 10 Retaining Ring AISI 316 Stainless Steel 11 Set Screw ASTM A194 Grade 8 (18-8) 12 Nameplate AISI 300 Series Stainless Steel 13 Drive Screw Stainless Steel Option: BPR is available in stainless steel configuration upon request. 9

Hydraulic Performance Test Lab Performance Profiled in Yarway s Hydraulic Performance Test Lab In our hydraulic performance test laboratory, state-of-the-art data acquisition and computer graphics techniques are called upon for evaluation of the significant performance characteristics of Yarway recirculation control s. The lab s equipment makes it possible to test a over its complete flow range for factors including: Total flow through the pump Disc position Pressure drop across the main check C v DP Valve response to sudden changes in flow piston pressure These detailed analyses are the user s complete assurance that the meets performance requirements in all respects and can be supplied with the. A certified test curve is shipped with each (see page 11 for example). Insist on it, as you would for your pump! 10

Certified Test Curve Main (GPM) 25.0 0 200 400 600 800 1000 1200 1400 1600 1800 Main DP (PSID) 20.0 15.0 10.0 5.0 0.0 Disc Lift (IN) 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00 0 200 400 600 800 1000 1200 1400 1600 1800 C v 10.0 9.0 80 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 1800 0 200 400 600 800 1000 1200 1400 1600 1800 Main (GPM) 120 100 80 60 40 20 0 Piston Pressure (PSIG) - - - - - 1600 1400 Total Flow (GPM) 1200 1000 800 600 400 200 0 0 200 400 600 800 1000 1200 1400 1600 1800 Main Flow (GPM) 11

How to Order Our sales representatives will help you select the correct for your application. Please complete this form before contacting the sales office to help ensure all necessary information is provided. Customer: Company: Project: Location: Phone: Qty Required: Tag(s) ID: Pump Flow Pump Discharge Pressure Pump pressure at Shut-off (zero flow): Pump pressure at Normal -Process- flow: Pump pressure at Minimum -Process- flow (optional): Pump pressure at Minimum pump protection flow: ARC Valve line pressure: Temperature Please Enter Both Temperatures Normal temperature at ARC Valve: F C Maximum temperature at ARC Valve: Fluid Liquid: Boiler Feed Water (In this case disregard S.G. and V.P.) Other (Please specify) Specific Gravity: Orientation of ARC Valve: Vertical Horizontal Vapor Pressure: Desired End Connections: Raised Face Flange Viscosity: Ring Type Joint (RTJ) Flat Face Flange Butt Weld Ends Other - Specify in Comments Comments: Automatic Recirculating Control (ARC ) Valve Data Sheet Delivery Required: Normal -Process- flow: Maximum -Process- flow: Minimum -Process- flow (optional): Minimum pump protection flow: E-Mail: Please Complete Flow Requirements Please Complete Pressure Requirements Desired Pressure Class: Desired Body Material: Desired Seal Material (except 2" to 8" 9200 and 9300): Pump Drive Type: Additional Info: GPM M 3 /H BPD (if Minimum Flow is to be considered in sizing) (Minimum required Recirculation Flow ) psi bar KgF/cm 2 Kpa (if Minimum Flow is to be considered in sizing) (at Minimum required Recirculation Flow ) (Line pressure at ARC Valve bypass port) 150 300 600 900 1500 2500 A216 Gr. WCB A351 Gr. CF8M A351 Gr. CK3MCuN (6Mo) A995 Gr. CD3MWCuN (Super Duplex) Ethylene Propylene (EPR or EPDM) TFE Propylene (Aflas or Fluoraz) Fluorocarbon Rubber (Viton ) Other - Specify in Comments Constant Speed - Motor Driven Variable Speed (VFD) - Motor Driven Variable Speed - Turbine Driven Other - Specify in Comments NACE Materials Required? Certificate of Compliance for Hydro Test Required? Flow Test with Performance Certificate Required? Magnetic Particle Test Required? Customer Inspection Required Prior to Shipment? Radiograph Inspection Required (specify scope)? Certified Material Test Report (Pressure Containing Components only)? Flow tests are generally conducted on all model 5300 and 7100 ARC s and one model 9100 or 9200 ARC per sales order line item at no additional cost. Model 9300 ARC s and other flow test requirements are upon request and at additional cost. If flange drilling is other than ANSI, please specify in Comments. Please include Pump Curve if available. Tyco Flow Control (TFC) provides the information herein in good faith but makes no representation as to its comprehensiveness or accuracy. This data sheet is intended only as a guide to TFC products and services. Individuals using this data sheet must exercise their independent judgment in evaluating product selection and determining product appropriateness for their particular purpose and system requirements. TFC MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE INFORMATION SET FORTH HEREIN OR THE PRODUCT(S) TO WHICH THE INFORMATION REFERS. ACCORDINGLY, TFC WILL NOT BE RESPONSIBLE FOR DAMAGES (OF ANY KIND OR NATURE, INCLUDING INCIDENTAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES) RESULTING FROM THE USE OF OR RELIANCE UPON THIS INFORMATION. Patents and Patents Pending in the U.S.and foreign countries. Tyco reserves the right to change product designs and specifications without notice. All registered trademarks are the property of their respective owners. Printed in the USA. 12 www.tycoflowcontrol.com