Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Similar documents
SECTION PANELBOARDS

A. Submit manufacturer's literature and technical data before starting work.

Design Standard. Purpose: Design Standard:

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

Quik-Spec Coordination Panelboard Specifications

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

WARREN COUNTY, N.Y. M/E REFERENCE

SECTION DISTRIBUTION AND GROUNDING

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

PANELBOARDS C1/C2 SECTION 6

2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

QMB Fusible Panelboards

Pow-R-Line 3E Panelboard

Panelboards Circuit Breaker / Lighting and Distribution

X1PB: Explosionproof Panelboards

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...

Application guide. Tmax Link OEM UL 891 Switchboard Program

Lighting and Power Distribution Panelboards

BUSWAY Low Voltage (Pow-R-Flex)

IN2 Enclosed Switches and Circuit Breakers

Horizontal Circuit Switchers

Horizontal Circuit Switchers

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Fused Coordination Panelboard

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SWITCHGEAR DIVISION PRODUCT PROFILES

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

A. This section includes unit capacitors for power factor correction.

Laser Service Factory-assembled Panelboards

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Medium Voltage Metal-Enclosed Switches

Electrical Notes: For PDC-1 provide a minimum of 6 spare circuits.

Three-Phase Pole Mounted Recloser

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

GE 8000-Line Motor Control Centers

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR

2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

University of Houston Master Construction Specifications Insert Project Name

Typical Specification

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Division 1 Explosionproof Panelboards

Effective December 2015 Supersedes September 2013

SECTION ELECTRIC DISTRIBUTION

Contents. 4 Loadcentres

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

SECTION MOTOR CONTROL

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

Introduction. Features. Intelligent Technologies Motor Control Center Structures

Power Break II Switchboard

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Generator/Loadbank Quick Connection Tap Box

C1000 Series Automatic Cap Bank

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Engine Generator Circuit Breakers

Cutler-Hammer. January 2001

Selection and application guide

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Transcription:

Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary overloads from motor driven devices, while instantaneous tripping is had for short circuits. Services: AC system 600 Volt AC maximum DC system 250 Volt DC maximum 3 Phase, 4 Wire 1 Phase, 3 Wire 3 Phase, 3 Wire 1 Phase, 2 Wire Interior: Branch circuit breakers to be bolted to bus All bus bar to be copper rated 1000 ampere per square inch Underwriters Laboratories Inc. listed for use with circuit breakers as manufactured by the following companies: General Electric, Seimens, Westinghouse-Eaton Fronts: Trim are flat gauge steel per code Standard painted finish ANSI 61 gray Directory card with plastic cover on front of trim Boxes: Galvanized sheet gauge steel per code 3/4 inch flange for rigidity and fastening trim Blank ends Wire gutters meet or exceed UL/NEC requirements Applications: Filnor, Inc. is a leader in custom and commercial power and distribution panels for: Aerospace Banking Communications Data Processing Electronics Government Medical Military Petrochemical UPS Power/Distribution Utilities Waste Water/Sanitation Page 1 of 5

Options Mains: Main bus to 1600 ampere Main circuit breaker to 1200 ampere Main fused disconnect switch Compression lugs Sub-feed lugs Interiors: To fit existing boxes Split bus Service Entrance Label Through-feed lugs Tamper-proof screws Boxes: Aluminum Stainless steel Nema 3R Nema 4X Nema 12 Special drilling Special knockouts Increase gauge Increase gutters Painted Fronts: Door over breaker handles Trim hinged to box Special locks Plastic directory card holder Special painting Split door Common trim over two boxes Circuit Breakers: Handle locking device Padlocking devices Increase interrupting capacity Shunt trip Undervoltage trip Auxiliary switch Interlock mechanisms Others: Metering Ground Bus Ground fault Nameplates Page 2 of 5

Specifications Furnish factory assembled CDP panelboards as manufactured by Filnor, Inc. where indicated on the drawings. Provide panelboards of dead front, circuit breaker type. Panels to have main lugs or main breaker as indicated on d r a w i n g s. Circu it breakers shall be bolton-type, quick-make quickbreak, trip- free, thermal magnetic with to ggle handles. T ripped indication shall be clearly shown on the breaker handle taking a positio n between ON and OFF. Circu it breakers shall be equipped with individually insulated, braced and protected connectors. Branch breakers to be connected for sequence phasing, i. e. breakers 1 and 2 connected to phase a, breakers 3 and 4 to phase b, etc, to conform to branch circu it numbering system sho wn on drawing. Polarity or block phasing w ill not be acceptable. The front faces of all circuit breakers shall be flush with each other. Large permanent individual numbers shall be affixed in a uniform position. Prov isio ns for additio nal breakers shall be such that field addition of connectors or mounting hardware will not be required to add breakers to the panelboard. Where spaces are called for, panel bus shall be extended behind the space. Panelboard bus structu re and main lugs or main breaker shall have current ratings as shown on the panelboard schedule. Such ratings shall be established by heat rise tests with maximum hot spot temperature on any connector or bus bar. Heat rise test shall be conducted in accordance with UL 67. All bus bar shall be copper. Bus bar shall be rated for 1000 amperes per square inch minimum. The panelboard assembly shall be enclosed in a steel cabinet. The size of the wiring gutters and gauge of steel shall be in accordance with NEMA Standards Publication No. PB1 and UL Standards No. 67 for panelboards. The box shall be fabricated from galvanized steel or equivalent rust resistant steel. Enclosure to be for indoor or outdoor use as indicated. A ground bar is to be mounted in the e n c l o s u r e. Trims to be flat cold roll steel with ANSI 61 painted gray finish. Trims to be fastened to box with cup washers and screw s. A circuit directory card with a clear plastic covering shall be provided on the inside of the door. Quality Assurance Reference Latest Standards: Underwriters Laboratories Inc. (UL) a. Panelboards - UL 67 b. Cabinets and boxes - UL 50 National Electrical Manufacturers Association (NEMA) a. NEMA -PB1 (latest revision) Federal Specifications a. Panelboards WP-115a b. Molded Case Circuit Breakers WP-375b National Fire Protection Association (NFPA) a. NFPA 70, National Electrical Code (NEC) Requirements of Regulatory Agencies: a. State Codes b. Local Codes and Ordinances Page 3 of 5

Catalogue No. & Options CDP MLB AMP VDC ENC Branch BKR MB AMP VDC ENC Branch BKR Main Lugs Only Ampere Bus Rating KA Space Rating 125 V DC 250 V DC Requirements 225 50 50 6 400 50 50 6 600 50 50 6 800 50 50 6 1200 50 50 6 2000 50 50 18 Main Breaker Vertical Mounted Ampere Interrupting Rating KA SYM Breaker Space Rating 125 V DC 250 V DC Type Requirements 225 42 42 HFDDC 12 400 42 42 HKDDC 18 600 42 42 HLDDC 18 800 42 42 HMDLDC 18 1200 50 50 NBDC 24 2000 50 50 PBDC 36 Branch Breaker Ampere Interrupting Rating KA SYM Breaker Space Rating 125 V DC 250 V DC Type Requirements *225 42 42 HFDDC 4 1/8 *400 42 42 HKDDC 5 1/2 *600 42 42 HLDDC 8 1/4 **800 50 50 HMD 8 1/4 **1200 50 50 NBCD 8 1/4 *225A, 400A, 600A, Breakers are double branch, **800A and 1200A breakers are single branch Page 4 of 5

CDP DC Panelboard Enclosure Type NEMA 1 Indoor 21 deep x 42 wide x 91 3/5 high NEMA 1A Indoor Gasketed 21 deep x 42 wide x 91 3/8 high NEMA 3R, Outdoor Raintight 25 deep x 42 wide x 91 3/8 high Notes 1. Enclosures are as follows: A. Front access only B. Welded 12 GA CRS with removable channel base C. Painted ANSI 61 light gray D. Top and bottom are solid, no cutouts E. Four top removable lifting eye bolts 2. Bus: Copper, silver plated, rated at 1000A per square inch 3. Maximum height of main device and branch breakers is 72 inches 4. UL listed and labeled interior 5. Ground bus, 1/4 inch x 2 inches copper 6. All lugs are AL/CU mechanical Please contact Filnor for further details. Page 5 of 5