Features and Benefits

Similar documents
MGE TM Galaxy TM 7000 GFC

MGE TM Galaxy TM 7000

MGE Galaxy 5500 Marine

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

PowerWave 33 Efficient power protection for today s IT and process-related work environments

SecureUPS On-Line 120V AC Output, 1300VA

MKN-DSP SERIES - THREE PHASE

Green Power 2.0 MASTERYS GP

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

D Series: UPS UPTO - 300KVA - Three / Three Phase

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

TECHNICAL DATA SHEET KVA UPS Systemss

60 to 160 kva.

Technical data sheets

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Industrial PFC UPS System

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

PowerWave 33, kw

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Smart-UPS On-Line 230 V

Features and Benefits

Technical data sheets

Master Plus kva

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheets

Onfiniti. 1 Phase UPS

TLE Series UPS 400/500 kw With eboost Technology

On-line, Single Phase, Double Conversion UPS

Technical Specifications

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Master Plus kva

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

Technical Data Sheets

Smart UPS On Line 120/208 V

TLE Series UPS 160/200/225/250 kw with eboost Technology

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

PowerValue 11/31 T kva

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

PowerScale kva Technical Specifications

S2000 PRODUCT RANGE. Ultra compact

3ph UPS NS3000 series kVA

UPS Multi Sentry 10-20kVA

TLE Series UPS 750/1000 kw With eboost Technology

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

PowerScale TECHNICAL SPECIFICATIONS

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Est FlexiPower Mini UPS FPX Mini kVA

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

TECHNICAL SPECIFICATIONS

EFFEKTA Power Supplies

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

Master DIALOG INDUSTRY RANGE

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

Enterprise Power Protection

ConceptpowerTM Modular kVA

Technical Data Sheets

MGE TM Galaxy TM 6000 : Specification guide. Single UPS, three-phase, 250 to 600 kva

DPA UPScale RI kw The modular UPS for customized solutions

Liebert. FP 50Z kva

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

PowerPro three phase UPS technical data

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Enterprise Power Protection

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Modular three-phase UPS system. DPA UPScale RI kw The modular UPS for customized solutions

APC by Schneider Electric MGE GALAXY 5500 Uninterruptible Power Supply Guide Specifications 20 kva to 120 kva Single UPS, three-phase

Secure Power Solution for Industry and infrastructure. International product guide. schneider-electric.com

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Phase Modular Finally the benefits of Modular ups are for all

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

Smart UPS On Line 120/208 V

Transcription:

MGE Galaxy 300 3:3 Phase: 10/15/20/30/40 kva, 3:1 Phase: 10/15/20/30 kva Effective and reliable 3-phase power protection designed to prevent downtime and data loss for mission-critical applications MGE Galaxy 300 - Simplicity you can trust. MGE Galaxy TM 300 provides an effective and reliable solution for protecting small server rooms, commercial buildings, and technical facilities. The online double-conversion topology supplies true isolation between input and output with a zero transfer time. Up to 30 minutes of integrated battery back-up, internal mechanical bypass and parallel capability allows for higher levels of availability. Remote and local monitoring/management capability is achieved through a built-in communication card with a simple Web/SNMP interface and a user-friendly display available in 18 languages. Both three-tothree and three-to-single phase configurations are available for convenient power distribution. Serviceability is greatly enhanced by front access for ease of maintenance in confined spaces. All of these features, along with the included start-up and on-site warranty, make the MGE Galaxy 300 the easiest UPS in its class to install, manage, and maintain.

Features and Benefits MGE Galaxy 300 Availability Dual mains input Allows standard installation of one or two independent power sources Automatic internal bypass Built-in 100 percent rated bypass static switch prevents interruption by allowing load transfer to utility power during heavy overloads Parallel 1+1 for redundancy Connected equipment can be powered with two UPS units in parallel to increase system redundancy Integrated battery back-up Provides higher level of availability with up to 30 minutes of runtime A robust charger for extended runtime shortens recharge time to prevent deep discharge damage and provides extended runtime of up to four hours Serviceability Manual maintenance bypass Easily accessible maintenance bypass allows complete isolation of each part of the system, facilitating maintenance operations without power interruption Front-access servicing Push-to-open, close door, and slide-out boards simplify installation and maintenance while minimizing space requirements World-class service organization With worldwide support and multiple levels of aftersales services, our package or individual on-site service options are structured for you to choose what APC can do for you Economy Power factor corrected input Prevents the need for oversizing cables, circuit breakers, and generator Temperature-compensated battery charging Sensors monitor battery temperature and adjust charger voltage to prevent premature aging and extend battery lifetime Efficient Up to 93 percent with on-line double conversion topology Reduced footprint Compact wide or narrow tower makes best use of available space Simplified Installation Easy to install Wheeled unit rolls into place, and all wiring connections are easily identifiable for time-saving installation Start-up wizard Step-by-step guidance and intuitive menu screens for easy set-up and system navigation Manageability Built in management card for SNMP Remote and local monitoring and management capabilities with simple Web/SNMP interface User-friendly graphical interface Easy-toread LCD provides mimic diagrams, audible alarms, and multi-language display, simplifying operation Typical Applications Small and medium businesses Commercial buildings: shop floors, hotels, convention centers Transportation and infrastructures Telecommunication Technical facilities

Reducing Environmental Impact for Sustainable Development Beyond international environmental regulations The critical power industry commits to environmental issues. Schneider Electric demonstrates a true commitment to sustainable development with systematic attempts to exceed current and future requirements imposed by standards that include: ISO 14001 certification of sites and R&D Eco-design standards and eco-production RoHS compliance MGE Galaxy 300 takes environmental issues into account at each stage of the product s life. The Restriction on Hazardous Substances Directive (RoHS) restricts the use of six hazardous materials in the manufacture of various types of electronics including lead, mercury, cadmium, hexavalent chromium, PBB and PBDE. Product development according to environmental standards Design Reduced number of parts and advanced digital electronics used to improve reliability and lessen environmental impact. Fewer electronic boards Software updates via downloading instead of changing boards Raw materials Compact size and low weight of design requires fewer, and more environmentally friendly, raw materials. New design for a transformerless UPS More silicon, less copper More powerful IGBTs changing boards Manufacturing Produced in factories that comply with the ISO 14001 standard to reduce: Energy consumption Packaging waste for supplier parts Amounts of materials used in the process Energy efficiency through quality power solutions Reduced consumption as a result of the IGBT rectifier (low harmonics), which in turn reduces sizing of the electrical distribution system (breakers, cables, generator). High-efficiency UPS solutions to reduce heat losses Up to 93 percent efficiency in on-line mode

Battery Options MGE Galaxy 300 provides integrated batteries for runtimes up to 30 minutes. For extended runtime needs, three external battery cabinets can be used with a robust charger option to increase runtime up to four hours. Temperature sensors come standard to monitor the battery ambient temperature and adjust the charger voltage to protect the batteries and delay premature aging. External battery function is also protected by a circuit breaker equipped with an undervoltage coil in the external battery cabinet. UPS with integrated batteries KVA 3:1 10 G3HT10K3IB1S G3HT10K3IB2S 15 G3HT15K3IB1S G3HT15K3IB2S 20 G3HT20K3IB1S G3HT20K3IB2S 30 G3HT30K3IB1S G3HT30K3IB2S 3:3 G3HT10KHB1S G3HT10KHB2S G3HT15KHB1S G3HT15KHB2S G3HT20KHB1S G3HT20KHB2S G3HT30KHB1S G3HT30KHB2S 40 N/A G3HT40KHB1S G3HT40KHB2S Typical runtime (*) 13 min 35 min 9 min 33 min 12 min 25 min 13 min 29 min 10 min 20 min UPS with robust charger for extended runtime and external battery cabinet options KVA UPS (3:1) UPS (3:3) Battery Cabinet 10 G3HT10K3ILS G3HT10KHLS G3HTBAT1 G3HTBAT2 15 G3HT15K3ILS G3HT15KHLS G3HTBAT1 G3HTBAT2 20 G3HT20K3ILS G3HT20KHLS G3HTBAT2 30 G3HT30K3ILS G3HT30KHLS G3HTBAT2 Typical runtime (*) 113 min 203 min 267 min 65 min 121 min 173 min 86 min 120 min 55 min 71 min 40 N/A G3HT40KHLS 53 min Battery Cabinet Dimension (HxWxD): 1300x500x850mm G3HTBAT1 is composed of 1 cabinet; G3HTBAT2 and are composed of 2 cabinets (*) Typical runtime at 70% load

MGE Galaxy 300 Economy Optimized features Galaxy 300 is designed to provide optimal performance. The most in-demand features have been carefully selected to propose the right solution for predictable and reliable power protection, offering the benefits of a true doubleconversion online architecture. QM1 ~ QB ~ QOP Reduced footprint Narrow and wide tower options optimize the system footprint based on kva power requirements. QM2 - + Simplified maintenance A full maintenance bypass with front access permits complete isolation of each part of the system and facilitates maintenance operations without power interruption. Q3BP Availability Wide input voltage range For harsh electrical environments. Double-conversion on-line topology Guarantees a consistently high level of power quality. Parallel capability Power the connected equipment with two UPS in parallel to increase system redundancy. Dual feed input Allows standard installation of one or two independent power sources. Options External battery cabinet For additional runtime. Supplied with breakers and temperature sensors. Parallel kit For 1+1 parallel redundancy. (G3HTPARKITS) Empty cabinet for third-party batteries or transformers Line up and match cabinet for third party batteries and transformers. Communication cards Network Management Card supplied with the product (AP9630) for Web/SNMP functions Optional card (AP9635CH) for additional features such as Modbus/Jbus over RS485, Teleservice, and environmental sensors: Temperature (AP9335T), Temperature and Humidity (AP9335TH), Dry contact I/O (AP9810)

Technical Specifications Rated Power (kva/kw) 10/8 15/12 20/16 30/24 40/32 Normal AC supply input Input voltage (V) Frequency (Hz) Input Power Factor THDI 380/400/415 V (Three-phase + Neutral) 45 65 Hz Up to 0.99 at >50% load <7% at full load Input Voltage Tolerance Utility Operation 340V to 477V at full load ( -15% to +20% at 400V) Dual Mains Input Output Nominal Output Voltage (V) Yes 3:1-220/230/240 V N/A 3:3-380/400/415 V (Three-phase + Neutral) Efficiency at Full Load (on-line) Up to 93% Output Frequency Overload Capacity Utility Operation Output Voltage Tolerance Communication and Management Communication Interface Control Panel Dimensions and Weight Mains synchronized in normal operation 50Hz or 60Hz + 0.1% free-running 125% for 2 minutes, 150% for 10 seconds +2% static, +5% at 100% load step Network Management Card (AP9630) multi-function LCD, status and display console UPS Dimensions (HxWxD) 3:1 1300x400x860 mm 1300x500x860 mm N/A UPS Dimensions (HxWxD) 3:3 1300x400x860 mm 1300x500x860 mm UPS Weight (kg) without Batteries (3:1 / 3:3) 145 / 130 kg 185 / 130 kg 198 kg UPS Maximum Weight (kg) with integrated Batteries Battery Cabinet Dimensions (HxWxD) Battery Cabinet - Minimum weight Battery Cabinet - Maximum weight Regulatory Safety 615 kg 1300x660x850 mm 105 kg 610 kg IEC/EN62040-1-1 EMC/EMI/RFI IEC 62040-2 Approvals Environmental CE, TUV Operating Temperature 0 C to 35 C Relative Humidity Operating Elevation 0 to 90% non-condensing 0 to 1,000m at 100% load Max. Audible Noise at 1m from unit 54 dba at 100% load 53 dba at 100% load Protection Class IP20 2012 Schneider Electric. All Rights Reserved. Schneider Electric and APC are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners. e-mail: esupport@apc.com 132 Fairgrounds Road, West Kingston, RI 02892 USA 998-3863