Kompensator External Low Voltage Heating Cable System

Similar documents
EXT5R & EXT3T Series External Heating Cable System for Pipe Freeze Protection

C Power Connection Kit

CARAPACE Job-Ready Freeze Protected Polyethylene Pipe System

Retro-Line Internal Freeze Protected Water Supply Systems

HTP PTP/ PTJ Power Connection Kit for Pipes

Intelligent Flap Controller

SUBMERSIBLE SUMP PUMPS

SmartStart. Model: SS-12v

Safety-TrimTM. Dual axis servo controller. with 2 speed presets

SUBMERSIBLE SUMP PUMPS

Power Connection Kit installation instructions

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

Integrated Back-up Battery System

MODELS CX10 and CX20 INDUSTRIAL PUMPS INSTRUCTIONS AND SERVICE MANUAL

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

AUTOMATIC SUBMERSIBLE UTILITY PUMP

SRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions

3M Cold Shrink Splice Kit QS-III 5536A

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Cold Shrink QS T Trifurcating Transition Splice Kit

PRE-PLUMBED SEWAGE SYSTEM

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Power. On Your Terms.

StormPro BA Series Sump Pump

Installation Instructions / Warranty. Citterio 39115XX1

Matala. VersiFlow Series. Instruction and Maintenance Manual

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

GeyserMax-Flow Series

GARDEN HOSE UTILITY PUMP

10 Year Limited Warranty

User s Manual and Operating Instructions

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.

QT-III Cold Shrink Silicone Rubber

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

USB Charge Port Installation Instructions

UV DISINFECTION UNIT MODEL 3G

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

Installation Instructions. Fog Lights. The lamps get very hot when they have been in use. Do not touch them as they may cause burns.

Model A Turn Signal Kit Installation Guide

Installation Instructions / Warranty

Air Curtain. Installation, Operating and Maintenance Instructions

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance

RANGE HOODS USER INSTRUCTIONS

3M Mechanical Shearbolt Connectors, QCI Series

StormPro BCV400 Sewage Ejector Pump

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Owner s Manual Phoenix Quick Chamber

TBM Series 3-Way Ball Valve

MetroPrime 22MPC Self-Priming Centrifugal Pump

Power-Limiting Cables

G8 Portable Fuel Transfer Pump Owner s Manual

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

SUPER PUMP OUT SYSTEM

Manual Transfer Switch

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

PowerFLEX Module Limited Warranty Program

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

DC to AC Power Inverters

DC to AC Power Inverters

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

END USER TERMS OF USE

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Pressurized oil drain for collection of used lubricants and anti-freeze.

BP1204 INSTALLATION/OWNER'S MANUAL

INSTALLATION/OWNERS MANUAL

Installation and Operation Manual

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

Owner s Guide ca4054 ca4554

Charging with AC (wall) Charger

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

MV Series Motors Operation & Parts Manual

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

G500REC Manual Covering System for Containers

Rechargeable Inflator

Transcription:

External Low Voltage Heating Cable System LOW VOLTAGE Installation Instructions General Information Kit Contents Qty Description 1 heating cable at pre-determined length Table of Contents General Information........................ 1 Warnings.............................. 1 Kit Contents............................ 1 Optional Accessories........................ 2 Ordering Chart........................... 2 Pre-Installation Information..................... 2 Installation Instructions for Cables on Pipe...... 3 Wiring, Sizing and Power Requirements.............. 4 Control Options........................... 4 Wire Schematics.......................... 5 Examples.............................. 6 Warranty.............................. 7 is the only job-ready, low voltage, heating cable system available on the market. can be used on all metal and nonmetal pipe materials, commonly used in the transportation industry to maintain hydraulic oil viscosities in cold temperatures and tanker fluid delivery hoses. employs the performance and operating characteristics of self-regulating heating cable technology and can be used with thermal insulation to increase energy efficiency. is applied on the outside (externally) of the pipe to provide reliable freeze protection. 1. is suitable for use on metal and non-metal pipes. 2. Exposure to temperatures above 150 F (65 C) while operating will shorten the expected life of the heating cable. Maximum exposure temperature is 185 F (85 C) when not powered. Before installing on hot water pipes, set the water heater thermostats below 150 F (65 C). * Do not install in temperatures below 40 F ( 40 C). 3. Remove any old heating tapes or insulation before installing the heating cable. 4. Use a minimum of 1/2" thick insulation or equivalent. 5. The minimum bending radius of the heating cable is 1/2". 6. If the system must be taken off and re-installed carefully follow all installation instructions. 7. Leave these instructions with the user for future reference. 8. These systems can be used with thermostats where applicable to improve energy efficiency. is a technically advanced product. Handle it with proper care and be sure not to damage the outer sheaths or jackets of the cable. Read the Warnings and Installation Instructions completely before installing this product. Fire and shock hazard. This component Is an electrical device which must be installed properly. Follow these important warnings to ensure proper operation and to prevent electrical or fire hazard. 1. The heater (cable) must not exceed the recommeded voltage as described on the product. It is the installer's responsibility to make sure the product is protected from an increase in voltage and to provide correct over-current protection. 2. To minimize the danger of fire if the heating cable is damaged or improperly installed, must be installed with over current protection and must also be properly grounded. Arcing may not be stopped by conventional circuit protection. 3. The cable is designed for water pipe freeze protection. Thermal design is based on dry insulated metal and plastic pipes. 4. As with any other electrical product, exposure of the cable to water or other electrolytes if the cable is damaged creates a risk of electrical shock or fire. 5. Connect only to a dedicated circuit with appropriate over current protection and which are protected from rain and other water (dry location). 6. The cable jacket must not be cut, nicked, or worn down, therefore: Never cut the cable's outer jacket. Prevent chaffing. Do not install the cable where objects might hit it or cut it or where it might be damaged by rubbing against rough surfaces. Before installation, file and remove any sharp edges which might damage the cable. Make sure the cables cross only smooth, non-abrasive surfaces. Protect the complete system with a metal sheath where it might be damaged by animals or impact. Do not use any wire or clamps to attach the cable to the pipe. Use 1/2" or 1" tape, fiberglass tape, or plastic ties. Do not use nails, metal clamps, wires or other devices that might cut the cable or cord to support it between the pipe and its power location. If you discover a nick or worn spot on your cable, Immediately disconnect the system and replace the cable. Inspect the cable periodically for damage. And remember to replace any damaged insulation after each inspection of the cable. 6. Never attempt to splice or repair a damaged cable. Replace it with a new unit. The system is not designed to be repaired and to do so may create a danger of fire or shock. 7. Do not install the cable close to flammable materials, liquids, or fumes. If the cable is cut while the system is energized and if there is moisture present, there is a risk of fire and flammable objects or fumes near the cable might be ignited.

Installation Pre-Installation Information General Requirements For Pipe Freeze Protection heating cables may be used on metal and plastic water pipes. Please consult Heat-Line if you have other pipes or tubing. heating cables are not intended for use inside any pipes, for freeze protection of liquids other than water, or for use in classified hazardous locations. Install with a minimum of 1/2" fire-resistant, waterproof thermal insulation. Never use on any pipes that may exceed 150 F (65 C). Use appropriate wire gauge for the heating cables circuitry. Install only in accessible locations; do not install behind walls or where the cable would be hidden. Do not run the heating cable through walls, ceilings, or floors. Connect only to circuits with the appropriate over current protection and proper grounding and are protected from rain and other water. Important: For the Heat-Line warranty to be valid, you must comply with all the requirements outlined in these guidelines. Determine Which Heating Cable You Need for Pipe Freeze Protection Use the Tables 1 and 2 to select the correct heating cable. Add 2 foot to your pipe length for each valve or spigot on your pipe system. The charts assume the lowest outside temperature is 0 F (-18 C), with a minimum of 1/2" thick waterproof, fire-resistant thermal insulation (preformed foam). For protection to -20 F (-29 C), use 1" thick insulation. Important: All thermal and design information provided here is based upon a "standard" installation with heating cable fastened to an insulated pipe. For any other application or method of installation, consult Heat-Line at (800) 584-4994. Table 1 Metal Pipes Pipe diameter (in) 2 1/2 2 1 1/2 1 1/2 0 10 20 30 40 50 60 Pipe length (ft) Table 2 Plastic Pipes Pipe diameter (in) 2 1/2 2 1 1/2 1 1/2 0 10 20 30 40 50 60 Pipe length (ft) Bending the Cable When positioning the heating cable on the pipe, do not bend tighter than 1/2" radius. The heating cable does not bend well on a flat plane. Do not force such a bend as heating cable may be damaged. 1/2" Optional Accessories KHL-STAT Low voltage thermostat PLD-CG Cable guards (package of 4) INSUL-PAD Elastomeric flexible closed-cell insulation, 1/2" (12.5mm) thick, 6" (152mm) wide, 10' (3m) long INSUL-FOIL Aluminum reflective metalized foil bubble insulation FOIL-TAPE Professional grade all weather foil tape 2.83" x 150' (72mm x 46m) INSUL-1.00 Closed cell polyethylene insulation sleeve for 1" ID pipe (6' long, 1 5/8" ID, ¾" thick wall) INSUL-1.25 Closed cell polyethylene insulation sleeve for 1 1/4" ID pipe (6' long, 1 7/8" ID, ¾" thick wall) INSUL-2.00 Closed cell polyethylene insulation sleeve for 2" ID pipe (6' long, 2 5/8" ID, ¾" thick wall) HLP-TAPE Black polyethylene insulation tape 2" x 100' (51 mm x 30 m) INSUL-LABEL Electric Heat Trace Caution Label for Insulation Ordering Chart Product Code Example: KHL123 040 CS Product KHL123 12 volt 3 watt per foot KHL125 12 volt 5 watt per foot KHL243 24 volt 3 watt per foot Cord-Set Type CS Cord connected (No GFCI) Length of Heater 5 to 40 feet 12 volt 3 watt per foot systems 5 to 30 feet 12 volt 5 watt per foot systems 5 to 60 feet 24 volt 3 watt per foot systems Notes: It is the requirement of the installer to provide proper voltage regulation and over-current protection. It is also the recommendation of Heat-Line that since the power consumption of the product can never be 0 to install a shut-off switch to prevent the draining of batteries or power supply. 2 of 8

Installation Installation Instructions for Cables on Pipe 1 Determine the length of cable required For systems with pipe diameters up to 1 1/4" I.D. a single straight run should be Sufficient using the KHL125 Series. For systems with pipe diameters over 1 1/4" I.D. consult Heat- Line Corporation to discuss your particular requirement. Note: Pipes must be insulated for maximum efficiency and performance. Measure pipe to be heat traced 2 Apply cable to the pipe If your cable set is the same length as the pipe, run it straight along the pipe in the 4 or 8 o'clock position. For large diameter pipes you can pitch or spiral the heater evenly along the pipe length or run the cable longitudinally at the 4 or 8 o'clock position. To provide extra heat at valves and other fitting areas, simply wrap an extra 2 feet of cable at these areas. Fasten the cable at one foot intervals using quality electrical tape or plastic cable ties. DO NOT over tighten or compress the heater as this will damage the conductive core. If there is excess cable double it back. If your cable set is longer than the pipe, spiral it evenly along the pipe. Fasten the cable at one foot intervals using quality electrical tape or plastic cable ties. Note: Pipes must be insulated for maximum efficiency and performance. Straight Line Method Spiral Method (with optional enclosure) 1 foot Heating Cable Position 11 o clock Pipe 8 o clock 1 o clock Heating cable 4 o clock 1 foot 3 of 8

Installation 3 Protect the system with insulation Insulation may include foil bubble insulations, fiberglass pipe insulations in dry locations or foam insulations outside in wet locations. Before insulating ensure that there is no cable damage, such as nicks or cuts. Insulate the System Bubble Foil Insulation Fiberglass Insulation (dry location) Closed Cell Polyethylene Insulation Wiring, Sizing and Power Requirements The heating cable has a conductive polymer core and its heat output changes (increases or decreases) with heat and cold. It is important to understand however, the cable never operates at 0 output and that It is a consumer of energy when powered. Though the heat outputs will change with temperature variables along the pipe, It Is consuming power while it is on. Fuse and Breaker Sizing Recommendations It is recommended that you install a shutoff switch to avoid draining the battery or power supply. Please see control options for further information on controlling your. Note: It is the installer's responsibility to make sure proper voltage regulation is supplied. Note: Always fuse based on wire size as per electrical code. KHL123 Series (12 volt, 3 watts @ 50 F) Fuse or Breaker Size (AMP) Length (feet) Max. 40' 5 1 8 14 7.5 9 12 14 10 13 16 14 15 17 26 12 20 26 40 12 Wire Gauge (AWG) Suggested fusing for equipment protection and startup temperatures not colder than 10 F. KHL125 Series (12 volt, 5 watts @ 50 F) Fuse or Breaker Size (AMP) Length (feet) Max 30' 5 1 7 14 7.5 8 10 14 10 11 14 14 15 15 20 12 20 20 30 12 Wire Gauge (AWG) KHL243 Series (24 volt, 3 watts @ 50 F) Fuse or Breaker Size (AMP) Length (feet) Max 60' 5 1 15 14 7.5 16 23 14 10 24 35 14 15 36 48 12 20 48 60 12 Wire Gauge (AWG) Control Options: heaters can be installed with multiple control capabilities installed by others. These include and not limited to: Shut off switches LED indicator lights Low voltage thermostats Timers 4 of 8

Installation Wire Schematics Non metal Junction Box + Metal Junction Box + Non metal junction box Green Black Red Red heat shrink Fuse based on wire size (AWG) circuit ampacity and length Chassis box ground ground Green Metal junction box Black Red Red heat shrink Fuse based on wire size (AWG) circuit ampacity and length Single pole switch highly recommended Single pole switch highly recommended Splice Splice No Box Method Chassis post Black + Fuse based on wire size (AWG) circuit ampacity and length Barrel crimp Red Green Red heat shrink Pig tails Single pole switch highly recommended Splice 5 of 8

Installation Examples: Accessories Aluminum tape Part # FOIL-TAPE Insulation Part # INSUL-PAD Cable ties Cable guard Part # PLD-CG 1 2 3 Spiral on cable Criss cross at flanges and valves Wrap insulation over pipe and Finish off by enclosing in Aluminum Tape 6 of 8

Installation Limited Warranty During the time periods and subject to the conditions hereinafter set forth. Heat-Line will repair or replace to the original user any portion of your product which proves defective in materials or workmanship of Heat-Line. Contact Heat-Line or your installer for warranty service. At all times Heat-Line shall have and possess the sole right and option to determine whether to repair or replace defective equipment, parts or components. Damage due to natural events or conditions beyond the control of Heat- Line are NOT COVERED BY THIS WARRANTY. WARRANTY PERIOD: 12 months from date of purchase or 15 months from date of manufacture, which ever occurs first. ACCESSORIES, COMPONENTS, ELECTRONICS: Not manufactured by Heat-Line, are warranted only to the extent of original manufacturer s warranty. LABOUR, COSTS, ETC.: Heat-Line shall in NO EVENT be responsible or liable for the cost of field labour or other charges incurred by any customer in removing and/or reaffixing any Heat-Line product, part or component thereof. THIS WARRANTY WILL NOT APPLY: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided, (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and (d) to parts not used in accordance with applicable local codes, ordinance and good trade practices; (e) if the unit is moved from its original installation location or (f) if the unit is used for purposes other than for what it was designed and manufactured, PRODUCT IMPROVEMENTS: Heat-Line reserves the right to change or improve its products or any component thereof without being obligated to provide such a change or improvement for units sold and/or shipped prior to such change or improvement. WARRANTY EXCLUSIONS: As to any Heat-Line product after the expiration of the time period of the warranty applicable thereto as set forth above. There will be no warranties including any implied warranties of merchantability or fitness for any particular purpose. No warranties or representations at any time made by any representative of Heat-Line, shall vary or expand the provisions hereof. LIABILITY LIMITATION: In no event shall Heat-Line be liable or responsible for consequential, incidental or special damages resulting from or related in any manner to any Heat-Line product or parts thereof. In the absence of suitable proof of the purchase date, the effective date of this warranty will be based upon the date of manufacture plus 90 days. 7 of 8

Installation 2017 Heat-Line a division of Christopher MacLean Ltd. 01/17 Heat-Line Freeze Protection Systems 1095 Green Lake Road Algonquin Highlands, ON Canada K0M 1J1 Tel: (705) 754-4545 (800) 584-4944 Fax: (705) 754-4567 info@heatline.com www.heatline.com Heat-Line is a registered trademark of Heat-Line Corporation. Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Heat-Line a Division of Christopher MacLean Ltd. makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Heat-Line's only obligations are those in the Heat-Line Standard Terms and Conditions of Sale for this product, and in no case will Heat-Line be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Heat-Line reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification. 8 of 8