GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

Similar documents
Unilift KP 150, KP 250, KP 350

Grundfos.bk Page 1 Thursday, June 11, :59 PM GRUNDFOS INSTRUCTIONS. CRN MAGdrive. Installation and operating instructions

Grundfos MAGNA, Relay Module

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

GRUNDFOS INSTRUCTIONS MTA 110H-180. Installation and operating instructions

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

UP Series 200 GRUNDFOS INSTRUCTIONS. In-line, wet-rotor, single-speed, circulator pumps UP 43-70, UP , UP 53-45, UP 53-46

GRUNDFOS INSTRUCTIONS SQ, SQE. Installation and operating instructions

TPHK Series Immersible Pump

CR30 CR60 (Model B) CR

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

TPHK Series Immersible Pump

TPAK Series COOLANT PUMP

Submersible Tank Pump

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

GRUNDFOS INSTRUCTIONS JP-PS. Jet Pumps (JP) with Pressure Switch (PS) Installation and operating instructions

GRUNDFOS PRODUCT GUIDE LM, LP. Single-stage close coupled in-line circulating pumps 60 Hz

SQFlex battery back-up system

Redi-Flo4. Stainless Steel Submersible Pumps for Environmental Applications GRUNDFOS INSTRUCTIONS. US Installation and operating instructions

GRUNDFOS PRODUCT GUIDE CH, CHN. Horizontal multistage end-suction pumps

GRUNDFOS GROUNDWATER SERVICE MANUAL 300S. Parts List Submersibles. Contents Parts List Special Tools Standard Tools Part Dimensions

GRUNDFOS DOSING SYSTEMS

GRUNDFOS GROUNDWATER SERVICE MANUAL 230S. Parts List Submersibles. Contents Parts List Special Tools Standard Tools Part Dimensions

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

GROUNDWATER PRODUCTS

Series LM/LP. Installation and Operating Instructions LIMITED WARRANTY. Single Stage In-Line Centrifugal Pumps

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

6. Electrical. 7. Settings. 8. Quick

2 Stainless Steel Submersible Pumps for Environmental Purge & Sampling Applications

GRUNDFOS MAGNA Series 2000 MAGNA , , 65-60

GRUNDFOS INSTRUCTIONS. Hydro Multi-B. Installation and operating instructions

GRUNDFOS DATA BOOKLET. Self-priming multistage pumps 50 Hz

GRUNDFOS VERSAFLO up(s) THE QUIET REVOLUTION. Grundfos VersaFlo UP(S) Wet Rotor Circulators

grundfos smartflo SmartFlo System Sizing Pocket Guide Curves and sizing information for all SmartFlo systems

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Contents. General data. Technical data, SPK/CRK. General data, MTA(D) Technical data, MTA(D) General data, MTR. General data, MTC

Oxiperm 164 and 166 GRUNDFOS PRODUCT GUIDE. Automated preparation of chlorine dioxide

SL1, SLV Pumps GRUNDFOS PRICE BOOK

GRUNDFOS WHITE PAPER. When considering the overall pumping. COUPLINGS by Greg Towsley

SELF PRIMING CHEMICAL SERVICE PUMPS

CRI5. Parts List & Kits. GRUNDFOS Industrial Service Manual. Contents

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

GRUNDFOS Commer CR1. Parts List & Kits. Contents. Parts List Spare Part Kits Accessories Special Tools Standard Tools Tools for Torques

Pump Installation and Service Manual HRS Hydromatic Retractable System

SPC-PANEL Simplex, Single Phase Pump Control Panel

GRUNDFOS PRODUCT GUIDE. VersaFlo. TP circulator pumps 60 Hz

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

GRUNDFOS WHITE PAPER. Parallel Pumping by Steve Wilson WHAT IS PARALLEL PUMPING?

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

Duplex Booster System Instruction Manual

SUNC3000 / Item #40885

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

Service instructions. MS6 3.7 kw - 30 kw. 50/60 Hz 3~

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

HALLMARK INDUSTRIES INC

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

7 Maintenance Do not allow the sludge accumulation in the tank to exceed a 1 depth. Otherwise, the sludge build-up could damage the heating element(s)

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

CRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE 1 & 3 phase

Rhino HPP18V FLEX Hydraulic Powerpack

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

GRUNDFOS Commer CR3. Parts List & Kits. Contents. Parts List Spare Part Kits Accessories Special Tools Standard Tools Tools for Torques

Float Level Control Kits

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

MIL-24/2600Q MIL-24/3200DQ

Electric Actuator Installation, Operation & Maintenance Manual

JOHN DEERE 9970 COTTON PICKERS

CUSTOM CARRIERS. Crane Carrier Company Standard Warranty

IMPORTANT SAFETY INSTRUCTIONS

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N

HR-20P Pneumatically Controlled Pressure Regulator

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

P5510. Users Manual. Pneumatic Comparison Test Pump

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

SQ/SQE. Installation and Operating Instructions. High Starting Torque. Soft Start. Built-in "Smart" Motor Protection with automatic restart

HP190SL Series Slimline Radon Fans

HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

Universal Bevel Drives Service Manual

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Rhino HPP13 Flex Hydraulic Powerpack

StormPro BA Series Sump Pump

CR45-10 A-F-A-E-HQQE 3x400/ HZ

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

A2P Single Phase Automatic Industrial Battery Charger

CR120-2 A-F-A-E-HQQE 3x400/ HZ

Transcription:

GRUNDFOS INSTRUCTIONS MTC Installation and operating instructions

LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted to the original user only to be free of defects in material and workmanship for a period of 24 months from date of installation, but not more than 30 months from date of manufacture. Grundfos' liability under this warranty shall be limited to repairing or replacing at Grundfos' option, without charge, F.O.B. Grundfos' factory or authorized service station, any product of Grundfos' manufacture. Grundfos will not be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by Grundfos are subject to the warranty provided by the manufacturer of said products and not by Grundfos' warranty. Grundfos will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with Grundfos' printed installation and operating instructions. To obtain service under this warranty, the defective product must be returned to the distributor or dealer of Grundfos' products from which it was purchased together with proof of purchase and installation date, failure date, and supporting installation data. Unless otherwise provided, the distributor or dealer will contact Grundfos or an authorized service station for instructions. Any defective product to be returned to Grundfos or a service station must be sent freight prepaid; documentation supporting the warranty claim and/or a Return Material Authorization must be included if so instructed. GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUEN- TIAL DAMAGES, LOSSES, OR EXPENSES ARISING FROM INSTALLATION, USE, OR ANY OTHER CAUSES. THERE ARE NO EXPRESS OR IMPLIED WAR- RANTIES, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limit actions on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction. 2

CONTENTS Page 1. Applications 3 2. Type designation 3 2.1 Pump key 3 3. Technical data 4 4. Installation 4 4.1 Pump location 4 4.2 Suction conditions 4 5. Electrical connection 5 6. Start-up 5 7. Operation and maintenance 6 7.1 Lubrication and maintenance 6 7.2 Filters 6 7.3 Periodic checks 6 8. Service 6 9. Sound pressure level 6 10. Fault finding chart 7 11. Disposal 7 Before beginning installation procedures, these installation and operating instructions should be studied carefully. The installation and operation should also be in accordance with local regulations and accepted codes of good practice. 1. Applications The GRUNDFOS pumps, type MTC, are multistage centrifugal pumps designed for pumping liquids for machine tools, condensate transfer, liquid transfer in industrial washing machines and similar applications. The pump must not be used for the transfer of inflammable liquids such as diesel oil, petrol or similar liquids. The pumped liquid must not contain fibres. The pump is designed for pumping liquids with a density and viscosity corresponding to those of water. When pumping liquids with a density or viscosity higher than that of water, the motor size should be taken into consideration. 2. Type designation The standard range of pumps encompasses complete impeller in chamber combinations. Other lengths, against duty combinations, can be supplied by fitting empty chambers instead of standard chambers with impellers. The pump key on the pump nameplate indicates the number of chambers and impellers fitted to the pump. 1 2 3 4 5 6 7 Type Model 50 Hz 1 1/1 60 Hz 1 1/1 p/t Pos Description 1 Type designation 2 Model 3 Voltage 50 Hz 4 Full load current 50 Hz 5 Voltage 60 Hz 6 Full load current 60 Hz 7 System pressure / max. liquid temp 8 Power consumption 50 Hz 9 Nominal flowrate 50 Hz 10 Max. current 50 Hz 11 Nominal head 50 Hz 12 Max. head 50 Hz 13 Max. head 60 Hz 14 Nominal head 60 Hz 15 Max. current 60 Hz 16 Nominal flowrate 60 Hz 17 Power consumption 60 Hz 18 Insulation class 19 Enclosure class 2.1 Pump key A A P1 P1 V~ Q W I MAX V~ Q W I MAX bar/ C MAX CL 9 10 H A HMAX H A HMAX Example MTC 4-50 / 3 A -W -A -AUUV Pump range Nominal flow rate in m³/h Number of stages x 10 Number of impellers Code for pump version Code for pipework connection Code for materials Code for shaft seal and rubber pump parts AUUE = optional with EPDM rubber AUUV = Standard shaft seal m 3 /h m 3 /h IP 8 17 18 16 19 96472495 m m m m 11 12 13 14 15 TM03 3379 0306 3

3. Technical data MTC 2 and 4 Minimum liquid temperature [ C] / [ F] Maximum liquid temperature [ C] / [ F] Maximum ambient temperature [ C] / [ F] Maximum operating pressure [bar] / [psi] Enclosure class 4. Installation 4.1 Pump location The pump is designed for tank mounting in vertical position. The pump is positioned in a hole cut into the cover of the tank (upper side) and is secured to the tank by four hexagon head screws through the holes in the mounting flange. It is recommended to fit a sealing gasket between the pump flange and tank. Note: The pumps can only be mounted in vertical position. The MTC 2 and 4 must have access to the tank from the drain channel in the motor stool. Fig. 1 10/ 14 +90/+194 8, 12 and 16 +55/+131 +40/+104 8/116 12/174 IP 54 [TEFC] The pump must be installed so that persons cannot accidentally come into contact with the hot surface of the motor. Drain channel MTC 2 and 4 TM00 1923 3297 c Fig. 2 Pump mounting flange dimensions: L D1 D2 D3 4 x X MTC 2 and 4 8, 12 and 16 D1 [mm] / [in] 140/5.51 180/7.09 D2 [mm] / [in] 160/6.30 210/8.27 D3 [mm] / [in] 180/7.09 200/8.27 L [mm] / [in] 121/4.76 100/3.94 C ¾" NPT 1 ¼" NPT X [mm] / [in] 7/0.28 9/0.35 4.2 Suction conditions The bottom of the pump strainer must be at least 25 mm above the bottom of the tank. The pumps are designed to provide full performance down to a level of A mm above the bottom of the strainer. At a liquid level between A and B mm above the bottom of the strainer, the built-in priming screw will protect the pump against dry running. MTC 2 and 4 8, 12 and 16 A [mm] / [in] 37/1.1 40/1.6 B [mm] / [in] 22/0.9 25/1.0 TM00 4375 5298 B 25 mm A TM00 4841 3897 Fig. 3 MTC 2 and 4 4

6. Start-up A B 25 mm TM01 4326 5298 MTC 8, 12 and 16: Pay attention to the direction of the vent hole and take care to ensure that the escaping water does not cause injury to persons or damage to the motor or other components, see fig. 6. Fig. 4 MTC 8, 12 and 16 5. Electrical connection The electrical connection should be carried out in accordance with local regulations. Never make any connections in the pump terminal box unless the electricity supply has been switched off. If the pump is not connected to an electric installation, it must be connected to an external mains switch. The operating voltage and frequency are marked on the pump nameplate. Please make sure that the motor is suitable for the electricity supply on which it will be used. The motor must be connected to a motor starter. Motors up to and including 1.1 kw (2.0 hp): The terminal box can be turned to four positions, in 90 steps, see fig. 5. Proceed as follows: 1. Remove the four bolts securing the motor to the motor stool. 2. Turn the motor to the required position. 3. Replace and tighten the four bolts. The electric motor should be connected to the supply as shown in the diagram inside the terminal box cover. 0 Air vent screw Fig. 6 Before starting the pump, make sure: that all pipe connections are tight. that the pump body is partly filled with liquid (partly submerged). that the strainer is not blocked by impurities. Start the pump as follows: 1. Close the isolating valve on the discharge side of the pump. 2. See the correct direction of rotation of the pump on the motor fan cover. When seen from the top, the pump should rotate counter-clockwise. 3. Start the pump and check the direction of rotation. 4. MTC 2 and 4: Open the discharge isolating valve a little. Completely open the discharge isolating valve. 5. MTC 8, 12 and 16: Loosen the air vent screw in the motor stool. When a steady stream of liquid runs out of the vent hole, tighten the air vent screw and completely open the isolating valve. The pump has now been vented and is ready for operation. TM02 0935 0401 270 180 90 Fig. 5 Motors of 1.5 kw (2.0 hp) and up: The terminal box has one fixed position. TM00 4257 2294 5

7. Operation and maintenance Note: The pump is not allowed to run against a closed discharge valve for more than approx. 5 minutes as this will cause an increase in temperature/ formation of steam in the pump which may cause damage to the pump. 7.1 Lubrication and maintenance Pumps installed in accordance with these instructions require very little maintenance. When a mechanical shaft seal is fitted, it is selfadjusting and has wear-resistant seal rings which are lubricated and cooled by the pumped liquid. The pump bearings are also lubricated by the pumped liquid. The motor ball bearings are grease packed and sealed for life. No further lubrication is necessary. Pumps from 4 kw (5.0 hp) and up have angular contact bearings. 7.2 Filters Chip trays, filters, etc. should be cleaned at regular intervals to ensure a correct flow of liquid. 9. Sound pressure level Motor L pa [db(a)] [kw] [hp] 50 Hz 60 Hz 0.25 0.34 <70 <70 0.37 0.50 <70 <70 0.55 0.75 <70 <70 0.75 1.0 <70 <70 1.1 2.0 <70 <70 1.5 2.0 <70 71 2.2 3.0 <70 71 3.0 5.0 <70 71 4.0 5.0 73 71 5.5 7.5 73 78 7.5 10 73 78 7.3 Periodic checks At regular intervals, depending on the conditions and time of operation, the following checks should be made: Check the quantity of liquid and operating pressure. Check that there are no leaks. Check that the motor is not overheating. Check the tripping of the motor starter. Check that all controls are operating satisfactorily. If the above checks do not reveal any abnormal operating details, no further checks are necessary. Should any faults be found, check the symptoms with section 10. Fault finding chart. 8. Service If a pump has been used for pumping liquids which are injurious to human health or poisonous, it will be classified as contaminated. Do not turn the pump upside down during service. Residual liquids from the chambers may damage the motor. A contaminated pump must not be sent to Grundfos for service until Grundfos has received all necessary details about the pumped liquid, etc. Otherwise Grundfos can refuse to accept the pump for servicing. Possible costs of returning the pump are to be paid by the customer. 6

10. Fault finding chart Before starting work on the pump, make sure that the electricity supply has been switched off and that it cannot be accidentally switched on. Fault Cause Remedy 1. Motor does not run when started. 2. Motor starter overload trips out immediately when supply is switched on. 3. Motor starter overload trips out occasionally. 4. Motor starter has not tripped out but the pump does not run. 5. Pump runs but gives no liquid or pump capacity is not constant. a) Supply failure. Connect the electricity supply. b) Fuses are blown. Replace fuses. c) Motor starter overload has tripped out. Reactivate the motor protection. d) Main contacts in motor starter are not Replace contacts or magnetic coil. making contact or the coil is faulty. e) Control circuit is defective. Repair the control circuit. f) Motor is defective. Replace the motor. a) One fuse/automatic circuit breaker is Cut in the fuse. blown. b) Contacts in motor starter overload are Replace motor starter contacts. faulty. c) Cable connection is loose or faulty. Fasten or replace the cable connection. d) Motor winding is defective. Replace the motor. e) Pump mechanically blocked. Remove the mechanical blocking of the pump. f) Overload setting is too low. Set the motor starter correctly. a) Overload setting is too low. Set the motor starter correctly. b) Low voltage at peak times. Check the electricity supply. a) Check 1 a), b), d) and e). a) Pump strainer partly blocked by impurities. Clean the strainer. b) Liquid level in tank too low. Increase the liquid level. c) Pump rotates in the wrong direction. Change the direction of rotation of the motor. 11. Disposal Disposal of this product must be carried out according to the following guidelines: 1. Use the local public or private waste collection service. 2. In case such waste collection service does not exist or cannot handle the materials used in the product, dispose the product according to local regulations. Subject to alterations. 7

8

9

10

U.S.A. GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 Canada GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Phone: +1-905 829 9533 Telefax: +1-905 829 9512 Mexico Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L.C.P. 66600 Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010 Addresses revised 22.09.2005

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96487858 0106 Repl. 96487858 0602 US www.grundfos.com