PSU ¾ HP PUMP RETROFIT

Similar documents
(MOBILE, AIR SAMPLING PUMP SYSTEM)

(MOBILE, AIR SAMPLING PUMP SYSTEM)

Installation & Operator s Manual

3 October 2016 PN# V Dodge Twin Turbo Kit (I-00274) ½ D o d g e 2 4 v I S B

INSTALLATION AND USER MANUAL

INSTALL MANUAL D o d g e 1 2 v 6 B T A PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION.

Brute Force Intake System. Installation Instructions for: Part Number Toyota 4Runner 3.4L V Toyota Tacoma 3.

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION GUIDE

RAM FRONT RADIUS ARM DROP BRACKETS Installation Instructions

advanced FLOW engineering Instruction Manual P/N:

INSTALLATION INSTRUCTIONS

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION GUIDE

4. Remove (4) 10mm and (1) 7mm bolt that holds fascia at front corners, on each side

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION GUIDE

MODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO & UP

½ DODGE CUMMINS

STEAM N HOLD PARTS MANUAL S/N to 35389

Installation Instructions

Design of a Station for Pump Testing

advanced FLOW engineering Instruction Manual P/N: Make: Dodge Model: 2500 / 3500 Year: Engine: I-6 5.9L (td)

ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES

INSTALLATION INSTRUCTIONS

advanced FLOW engineering Instruction Manual P/N: Make: RAM Model: 1500 EcoDiesel Year: Engine: V-6 3.0L (td)

with installation boost GAUGE this manual is for use with systems

INSTRUCTION PLASTIC BATTERY BOX & CHARGER KIT

½ DODGE CUMMINS

Pump Gas Instructions for Polaris And 800 Models. Important Information before Installing This System:

Part # Mopar LX Level 1 Air Suspension System

OwNErS MaNual with INSTallaTION INSTrucTIONS

Arctic Cat ProClimb Sidekick Installation Instructions

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve

COLD AIR INTAKE INSTALLATION INSTRUCTIONS

Assembly Instructions John Deere EZ View Dust Diverter

KIT. light duty 6.2L chevrolet/gm diesel. for use on gm 6.2L diesel trucks equipped with the banks sidewinder turbo system

SS71R SAFARI R-SPEC SNORKEL Toyota Land Cruiser LJ70 Bundera 2.4L 4cyl Turbo Diesel (2L-T engine)

Priming Systems Installation Instructions

Procharger Stage II Intercooled Supercharger System (11-14 GT)

FRS/BRZ Air Oil Separator (AOS) Installation Manual

advanced FLOW engineering Instruction Manual P/N: Make: RAM Model: Diesel Trucks Year: Engine: L6-6.7L (td)

RAM HD Steering Stabilizer Clamp Installation Instructions

ENGINE KIT-MUFF RETRO

INSTALLATION & OWNER S MANUAL

MK-5000G exploded VieW

SS41HF Mitsubishi Pajero NS & NT V8/V9 Series 3.2 Litre Turbo Diesel (4M41 Engine) 3.8 Litre V6 Petrol (6G76 Engine)

advanced FLOW engineering Instruction Manual P/N: Make: RAM Model: Diesel Trucks Year: Engine: L6-6.7L (td)

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER: DS (Plastic Intake Tube)

STERILMATIC DIGITAL ELECTRIC STERILIZER PARTS AND SERVICE MANUAL

Installation & Operator s Manual

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

SHORT RAM INTAKE SYSTEM. Installation Instructions for: Part Number Dodge SRT-4 2.4L

TEL:1-866-XANATOS. INSTALLATION INSTRUCTIONS PART#: SR-DOR SPARTAN RUNNING BOARD DODGE PROMASTER 136 /159 wheel base 14-UP

SS820R SAFARI R-SPEC SNORKEL SUZUKI JIMNY 1.3L 4 Cylinder Petrol (G13B & M13A Engines)

COLD AIR INTAKE INSTALLATION INSTRUCTIONS

OEM BYPASS LIFT PUMP KIT

P844L3MS For Models: NL844L3.1MS1 and NL844L3.1MS2 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators

INSTALLATION INSTRUCTIONS

1501 Industrial Way N., Toms River, NJ Fax: PACKING LIST INSTALLATION INSTRUCTIONS

NOTE ITEM PART NUMBER KIT CONTENTS QTY

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS

ITEM PART NO. DESCRIPTION QTY BODY - SNORKEL (SS89HF) ½" AIR RAM ASSEMBLY BRACKET - UPPER MOUNTING 1

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER: DS

INSTALLATION INSTRUCTIONS SINGLE CHANNEL ISOLATOR

INSTALLATION & OWNER S MANUAL

MGB Alternator Conversion Installation Instructions For MGA & 1962 to 1967 MGB

INSTRUCTIONS. EZ-EFI FK In-Tank Fuel Kit

½ DODGE CUMMINS

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER:

Factory safe air/fuel ratio s for Optimum performance Patent# 7,359,795

3.4L V6 SUPERCHARGER 7 TH INJECTOR KIT

Parts Manual HLF 2500, 3000, 4000 & 5000 lb. Capacity Flipaway Liftgates

GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER ( MBH) REPAIR PARTS MANUAL. P/N , Rev. 1.2 [02/06]

TECHNICAL INSTRUCTIONS

INSTALLATION INSTRUCTIONS Part# , , ,

Master Power Brakes Electric Vacuum Pump Kit Various Applications P/N: AC9001K

Part # C-10 Level 1 Air Suspension System

GM FUEL PRESSURE SENSOR BY-PASS INSTALLATION INSTRUCTIONS P11X AF

INSTALLATION GUIDE. JK Rear bumper & tire carrier. AEV30105AC Last Updated: 10/11/16 US PATENT: D642,502 ; D

Installation Manual v1.0: Aurora Plus Turbo Kit ( ) 5.9L Dodge. Please read all instructions before installation.

Self-Deploying Rail Kit OEM INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS

Revised 10/23/2015 Page 2 of 10

INSTALLATION INSTRUCTIONS

PARTS MANUAL P For Models: NL773LW4 and NL773LW4E.

INSTALLATION GUIDE RAISED AIR INTAKE ½+ ram heavy duty diesel. AEV30240AA Last Updated: 12/11/14

PFadvantage Metalfor Araus 1360

Pro 575X, Pro 1075X Single Stage Tailgate Spreader

INSTALLATION INSTRUCTIONS

Setting the World s Performance Standards

Installation & Operator s Manual

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

99-03 V6 "Shaker" System Instructions. *03 Model requires new hood Contents w/ Kit. Tool List For Appliqué:

GROUP E EXPLODED VIEW: EV FUEL SYSTEM 2.4L G2 DRAWING #: 0G1151 ITEM PART# QTY. DESCRIPTION

SS16HFB Nissan GU Patrol Series L 4cyl Turbo Diesel (ZD30-DDTi Engine)

Part Number SP BMW 335i BMW135i 3.0L Twin Turbo L6

Set-Up Instructions. for EC-VM400. Motorized Valves

PART NUMBER: B (Blue Finish) C (Gun Metal Grey Finish) P (Vacuum Metalized Chrome-VMC) R (Red Finish)

132 GALLON CONCENTRATE DISSOLUTION UNIT GranuFlo AND DRY ACID

BD TrackMaster S D o d g e H P C R Installation Instructions

SS122HF TOYOTA HILUX (Oct 2011 onwards) 3.0L Turbo Diesel D-4D (1KD-FTV Engine)

Transcription:

HI-Q Environmental Products Co. Air Sampling Equipment, Systems & Accessories 7386 Trade Street San Diego, California 92121-2422 Phone: (858) 549-2820 Fax: (858) 549-9657 Web: www.hi-q.net PSU ¾ HP PUMP RETROFIT Revised: 7/28/06 SAO

PSU 3/4HP Pump Retro-Fit This retro-fit kit will convert any PSU with a ¼ HP vacuum pump to use a ¾ HP vacuum pump. This retro-fit kit will work for PSU s with the following manufacturer s part numbers: MRV-0523-BOX MRV-0523-PSU PSU-2 PSU-2-H 1. Tip the PSU up on its end and remove the four ¼-20 Hex Nuts on the bottom of the PSU that hold the pump. Be careful that the pump does not come loose and fall inside the enclosure. Tilt the PSU back onto its feet. 2. Open the lid of the PSU and put a piece of tape on the venturi hose that is closest to the control valve (this is the throat pressure tap). Disconnect the two Venturi Hoses from the small hose barbs on the black venturi. The Venturi Hoses should pull off with some effort. Disconnect the Inlet Hose and the Exhaust Hose as shown in the picture. These will be replaced and it is ok to cut them off.

3. Using the black venturi tube as a handle, lift the pump assembly out of the PSU and balance it on the edge of the PSU box. 4. Remove the box mounted hose barb for the exhaust hose and the exterior exhaust muffler. Install the plug furnished with the retro-fit kit in the hole in the box. 5. Disconnect the green ground wire and the power cord from the pump.

6. Place the pump assembly on a work surface. 7. Remove the Z-Bracket from the Control Valve and the pump and discard. Reinstall the bolt that held the Z-Bracket to the Control Valve. 8. Use a piece of tape to mark the end of the venturi closest to the control valve. Remove the Venturi and Control Valve assembly from the pump and dismantle the assembly such that the Venturi and the Control Valve can be re-used with the new 3/4 HP Pump.

9. Install the new black anodized aluminum mounting plate on the bottom of the 3/4 HP Pump with the long side of the mounting plate PARALLEL to the long axis of the pump using the provided ¼ hardware and install the new larger rubber mounting feet using the provided 5/16 hardware as shown below.

10. Install the Control Valve and Venturi on the 3/4 HP Pump as shown in the picture below using the supplied fittings. Make sure the end of the venturi with the tape marker is closest to the control valve. Install the hose barb 45º elbow with the end pointed up as shown. Be sure to use the supplied Teflon tape thread sealer or liquid thread sealer on all the pipe thread connections and make sure that all connections are tight. Any leaks in the inlet side connections will decrease the performance of the system. Exhaust side leaks will not decrease performance, but will allow hot (190 ºF) exhaust air to leak into the enclosure and will shorten the life of the system.

11. The long axis of the control valve should be parallel to the long axis of the pump. The venturi should be slightly angled as shown in the picture below to allow hand access to the Control Valve once the pump is installed in the PSU. 12. Tip the PSU-2 up on its wheels until it is resting on its handle side. Drill four 3/8 diameter holes as shown on drawing PSU-2-1023 PUMP HOLES. Follow the procedure shown in the notes of the drawing.

3 5/16" 3/8" HOLE 4 PLACES NOTES: 1. LAYOUT HOLE LOCATIONS AS SHOWN TO 1/8". 2. USE A CENTER PUNCH TO MARK THE HOLE LOCATIONS 3. DRILL HOLE LOCATIONS WITH 1/8" TO 3/16" DRILL FIRST 4. RE-DRILL HOLES WTH 3/8" DRILL 5. REMOVE ANY ALUMINUM CHIPS AND BURS FROM INSIDE OF BOX 5 5/16" PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF HI-Q ENVIRONMENTAL PRODUCTS CO. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF HI-Q ENVIRONMENTAL PRODUCTS CO. IS PROHIBITED. 6 1/8" 6" DO NOT SCALE DRAWING MATERIAL: FINISH: N/A N/A DRAWN BY: DATE: S.A. OWEN 7/28/06 HI-Q ENVIRONMENTAL PRODUCTS COMPANY 7386 TRADE STREET, SAN DIEGO, CA 92121 TEL: 858 549-2820 FAX: 858 549-9657 www.hi-q.net 3/4 HP PUMP RETRO-FIT KIT MOUNTING HOLE LOCATIONS FOR PSU-2 SERIES SIZE DWG. NO. A CAD FILE: PSU-2-1023 PUMP HOLES PSU-2-1023 HI-Q DETAILS.slddrw SHEET 2 OF 3 REV. A

13. Sit the PSU-2 back onto its wheels and front feet. Drill the pump exhaust hole per drawing PSU-2-1023 EXHAUST HOLE. Clean out any aluminum chips from the PSU box.

NOTES: 1. LAYOUT HOLE LOCATION AS SHOWN TO 1/8". 2. USE A CENTER PUNCH TO MARK THE HOLE LOCATION 3. DRILL HOLE LOCATION WITH 1/8" TO 3/16" DRILL FIRST 4. RE-DRILL HOLE WITH PROGRESSIVELY LARGER BITS OR WITH A HOLE SAW TO FINAL DIAMETER. 5. REMOVE ANY ALUMINUM CHIPS AND BURS FROM INSIDE OF BOX 7" PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF HI-Q ENVIRONMENTAL PRODUCTS CO. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF HI-Q ENVIRONMENTAL PRODUCTS CO. IS PROHIBITED. DO NOT SCALE DRAWING MATERIAL: FINISH: N/A N/A DRAWN BY: DATE: S.A. OWEN 4/1/06 45/64" to 3/4" HOLE FOR PUMP EXHAUST 2" HI-Q ENVIRONMENTAL PRODUCTS COMPANY 7386 TRADE STREET, SAN DIEGO, CA 92121 TEL: 858 549-2820 FAX: 858 549-9657 www.hi-q.net 3/4 HP PUMP RETRO-FIT KIT EXHAUST HOLE LOCATION FOR PSU-2 SERIES SIZE DWG. NO. A CAD FILE: PSU-2-1023 EXHAUST HOLE PSU-2-1023 HI-Q DETAILS.slddrw SHEET 3 OF 3 REV. A

14. Remove control panel to provide access to the wiring terminal strip. With the control valve towards the same end of the box as the wheels balance the 3/4 HP Pump assembly on the edge of the PSU box (this may require help) and connect the wiring per the wiring diagram shown in drawing PSU-2-1023 WIRING DIAGRAM. Replace the fuse in the control panel with the supplied 15 Amp Slo-Blo fuse.

15. Lower the pump assembly into the box and align the mounting feet studs with the four 3/8 diameter pump mounting holes drilled earlier. 16. Place one 1 ¼ OD Washer and one 5/16 lock washer and one 5/16-18 nut on each of the pump mounting studs protruding from the bottom of the PSU and tighten each nut.

17. Install the muffler jar assembly as shown below and connect to the 3/8 NPT elbow on the outside as shown in following picture. (Note: The following pictures are of a prototype unit and show some equipment not on a stock PSU-2). Connect the blue exhaust hose from the pump to the muffler jar. Be sure that the power cord (orange in the picture below) does not contact the muffler or the exhaust hose.

18. Connect the braided intake hose to the 3/8 hose barb on the wall of the PSU box as shown below. Connect the two Venturi Hoses to the two small hose barbs on the venturi. Make sure to install the hose with the tape marker on the hose barb closest to the control valve. (Note: The following picture is of a prototype unit and shows some equipment not on a stock PSU-2) 19. Plug PSU into GFCI outlet. 20. Turn on pump and test. 21. Consult HI-Q (858-549-2820) with any questions.

Parts List for P/N: PSU-1023 ¼ HP to ¾ HP Retrofit Kit QTY DESCRIPTION: PUMP ASSEMBLY: 1 ¾ HP 1023 SERIES PUMP, MUFFLER CHAMBER REMOVED 1 3/8 NPT FEMALE BRASS ELBOW 1 3 1/2" LONG 3/8 NPT BRASS NIPPLE 4 1023 PUMP MOUNTING BUMPER 8 5/16-18 HEX NUT 8 5/16 LOCK WASHER 4 5/16 WASHER 4 5/16 FENDER WASHER 1 3/8 NPT NIPPLE FULL THREAD SS 1 3/8 NPT x 3/8 HOSE BARB 45º ELBOW 1 MRV-PSU-007 WIRING HARNESS 1 BLACK ANODIZED ALUMINUM PUMP MOUNTING PLATE 4 ¼-20 BOLTS FOR MOUNTING PUMP TO MOUNT PLATE 4 ¼-20 NUTS 4 ¼ WASHERS 4 ¼ LOCK WASHERS MCV-260 CONTROL VALVE AND PARTS: 1 2" BRASS PIPE 1 3/8 NPT FEMALE BRASS ELBOW 1 3/8 NPT NIPPLE FULL THREAD SS 24" 3/8 ID BRAIDED POLY TUBE 1 3/8 PUSH LOCK HOSE BARB EXHAUST PARTS: 1 3/8 NPT x 3/8 HOSE BARB 45º ELBOW 1 3/8 NPT NIPPLE FULL THREAD SS 1 3/8 NPT FEMALE BRASS ELBOW 4 3/8 FLAT WASHER SS 2 SMALL HOSE CLAMPS 5" 3/8 ID BLUE EXHAUST HOSE 1 3/8 NPT FILTER/ MUFFLER 1 ALUMINUM EXHAUST CAN ASSY. 1 11/16 DIA. BLACK PLASTIC PLUG FOR OLD EXHAUST HOLE CONTROL PANEL PARTS: 1 15 AMP SLO-BLO FUSE