POWER REGULATOR LD -40PSU

Similar documents
Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

FX2N-2LC SPECIAL FUNCTION BLOCK

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

EVS RP6020. Instruction Manual

35 35A 50 50A 1 Single phase. Solid state power controller

EX Series. Electric Actuators for Ball and Butterfly Valves

Pressure Transmitter

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

RP Instruction Manual

ZJ -4010D TENSION CONTROLLER MODEL LD-30FTA INSTRUCTION MANUAL

This section is specifically about safety matters

Power Controller. (see note 1) 10 sec

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

EX Series. Electric Actuators for Ball and Butterfly Valves

HS1C Interlock Switches with Solenoid

DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual

Battery Unit BHM60PC/BHM100PC Instruction Manual

Model Number Structure

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

TOWA SEIDEN INDUSTRIAL CO., LTD.

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Portable Instruments. Bulletin 2000-E

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

HS1L Interlock Switches with Solenoid

Filterpack FR-BFP2-(H)0.4K to (H)15K

EEMB CO., LTD. Lithium Manganese Dioxide Battery Specification. High Power Type. Prepared Checked Approved. Signature Checked Approved

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Digital Flow Switch (Sensor Part) Operation Manual

Extended Panel Operation Manual RKP001Z-0

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS

VF-S11 RS485 built-in board option RS4003Z Instruction Manual

Table of Contents Title Page No.

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

SG-B1 SERIES / SG-A1 SERIES

MITSUBISHI LARGE CAPACITY INVERTER MELTRAC-REC(MT-REC) -INSTRUCTION MANUAL- 12 Pulse Bridge Converter

MODEL 3567A. Digital MΩ Tester. Instruction Manual

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

LS200 Series Instruction Manual

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1

Differential Pressure Transmitter

SHOCK RELAY R INSTRUCTION MANUAL WARNING

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Table 2 Models BST12M-0.7S03PDM BST12M-0.7S06PDM BST12M-0.7S10PDM Conditions Input voltage range

0.6A, 1.5A, 2.25A, 3A/Phase

MODEL UC 14YFA. Hitachi. Power Tools TECHNICAL DATA AND SERVICE MANUAL CHARGER UC 14YFA SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

INSTRUCTION MANUAL FOR JB SERIES THYRISTOR REGULATOR

B297SB-01-1K40. AnyWireASLINK System Product Guide. ASLINKSENSOR [Photo Interrupter type] -B297SB011K40 1/7- [Function] [Notes on Safety]

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

The Multivariable Air Flow Meter

Model Number Structure

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

DRB-1 Series Instruction Manual

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

Connection and Operation (Speed Control)

HS1C-P Interlock Plug Unit with Door Lock

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

The Multivariable Air Flow Meter

Digital display Pressure range ON/OFF output Linear output Model

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Analog Output Terminal

Transistor Remote Modules

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

2-Color Display High-Precision Digital Pressure Switch

Analog Input Terminal

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

SHIMADEN SINGLE-PHASE THYRISTOR POWER REGULATOR

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Lumitester PD-20 Control Kit

Flowsensor for compressed air

Technical Information Solid State Relays. Glossary. Solid State Relays

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

2-Color Display High-Precision Digital Pressure Switch

HS5E Miniature Interlock Switches with Solenoid

1 Form A 5A small size power relay for interface

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

D4DL. Guard Lock Safety-door Switch. Model Number Structure

RoHS-Compliant Brushless Motor Systems FBL Series. Features

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

ROGOWSKI LEAK METER MODEL RLM-1

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

Instruction Manual. Selectable Microstep 5-ph Stepping Motor Driver RD-053MS RORZE CORPORATION

KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers:

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

2 1.Nominal Voltage 1.2V. 2 6.End Voltage of Discharge 1.0V

Transcription:

JZ99D4121A AMPIFIRE AMPIFIRE TYPE D-4PSU ZJ-46A ISTRUCTI MAUA Manual number JZ99D4121 Sub number A Date of preparation ov. 2 Thoroughly read this instruction manual, and then use the unit correctly. Especially, make sure to read "s on Safety" before using the unit. Carefully store this instruction manual, and see to it that the end user receives it. This printed matter is issued in March 2. The specifications are subject to change without prior notice. on installation and wiring electrical shock or damage in the unit Perform grounding (grounding resistance :1 Ω or less) to the grounding terminal or casing sheet metal area of the unit using a wire of 2 mm 2 or more. Otherwise, electrical shock on installation and wiring Separate the wiring of the strong electric system from the wiring of the weak electric system, and avoid common grounding. Otherwise, noise may be superimposed on the wiring of the weak electric system, and malfunction may be caused. and never use unused terminals for any external lines. Otherwise, the unit may be damaged. Installation and environment 1. Functions and Features The power amplifire D-4PSU is designed only for powder clutches/brakes and hysteresis clutches/brakes. This power amplifire operates in a wide power range of 8 to 264 AC, and is equipped with built-in control outputs of 24 DC/3.8 A. 1) Features (1) Switching regulator method (2) Operates in a wide power range of 8 to 264 AC. (3) Constant voltage control method (4) External control signal (: Remote control / input) () Digital display (4-digit, 7-segment ED) (6) for external variable (: Analog signal input) (7) Protection against load short-circuit and short-circuit warning indication (-ED) (8) two-step ing function (9) Power factor of 8 or more [1] oltage adjusting variable [2] [] --Changes over the adjustment mode. [3] Adjustment mode indicator ED (green) [4] Overcurrent detection indicator ED (red) [] Power indicator ED (green) [6] 7-segment display [7] oltage indicator ED (red) [8] voltage ()/output percentage () display selector [9] percentage () indicator ED (red) [1] External variable validity indicator ED (green) [11] -----Determines data setting. [12] [ ] [13] [ ] [14] indicator ED (green) [1] / selector 2. Installation and Wiring s on Safety (Make sure to read this paragraph before using the unit.) Make sure to thoroughly read this instruction manual, technical data, etc. before using the unit, and pay attention to assure safety while using the unit. In this manual, cautions on safety are classified into "DA- GER" and "CAUTI". of death or serious injury is expected. of medium or slight injury is expected or property damage exclusively is expected. Even an item is classified as "CAUTI", its contents are important and it may lead to a serious result depending on the situation. Make sure to observe every item. The unit is manufactured under severe quality control system. When applying the unit to a facility where a failure of the unit may lead to a serious accident or loss, however, systematically install the backup or fail-safe function. Carefully store this instruction manual so that it can be referred to at any time if necessary, and see to it that the end user receives it. on design Set up the emergency stop circuit independently outside this power supply unit. Otherwise, the machine may become out of order and an accident may occur when malfunction occurs in the power supply unit. Use the wire size suitable to the current capacity in wiring. If a wire having smaller current capacity is used, the insulation sheath will be melted and insulation will become defective. In this situation, electrical shock or short-circuit may occur, and fire may occur also. ever use the unit in an atmosphere having danger of inflammation or explosion. Otherwise, inflammation or explosion ever modify nor disassemble the unit. Otherwise, the unit may fail, or an accident such as fire and damage ever drop cutting chips and wire chips while tapping screw holes and performing wiring. Cutting chips and wire chips may cause damage in the unit, fume, fire, malfunction or others. When disposing of the unit, handle it as industrial waste. Installation and environment ever install the unit in a place where dusts, soot, conductive dusts or corrosive gas is present or a place exposed to high temperature, condensation or wind and rain. ever install the unit directly in a place where vibration or impact is applied. Otherwise, the unit may be damaged, malfunction or be deteriorated. on operation ever touch a or with wet hand. Otherwise, electrical shock ever supply the power to the unit nor operate the unit while the main body panel, terminal cover, etc. are open. While the panel or cover is open, a high voltage area may be exposed and electrical shock We shall not be responsible for any damage caused by repair, disassembly, modification, etc. performed by a third party other than or a company specified by. Accordingly, ask a service network specified by for repairs and disassemblies. The above cautions on safety and the specifications described in the instruction manual and technical data are subject to change without prior notice. 2) Major applications (1) Manual power supply unit controlled through the variable on the panel surface. (2) Manual power supply unit controlled through an external variable. The output can be adjusted using an external variable when the variable provided on the panel surface is made invalid and a variable of to 2kΩ (1/2 W or more) is connected to the output terminal () and input terminal (-). (3) Power amplifier using an external voltage signal The output can be adjusted using an external voltage signal when the variable provided on the panel surface is made invalid and the voltage of to is input to the input terminal (-). (4) two-step ing function The output in the output condition can be adjusted within the range from to 1. The output can be ed in two steps using a knob or an external voltage signal. 3) Panel configuration REGUATOR D -4PSU [6] [7] [8] [] [4] [3] [2] [1 ] OTAGE ADJ. 1 [9] [1] [11] [12 ] [13] [14] [1] 1) Installation ever drop cutting chips and wire chips while tapping screw holes and performing wiring. Cutting chips and wire chips may cause damage in the unit, fume, fire, malfunction or others. Make sure to turn off all phases of the external power supply before starting the installation and wiring works. Otherwise, electrical shock or damage in the unit ever install the unit in a place where dusts, soot, conductive dusts or corrosive gas is present or a place exposed to high temperature, condensation or wind and rain. ever install the unit directly in a place where vibration or impact is applied. Otherwise, the unit may be damaged, malfunction or be deteriorated. This power amplifire can be installed on the floor surface or panel surface. ever install the unit in such a manner that the panel surface of the main body faces upward or downward.

1 a) Installation on floor surface OTAGE ADJ. REGUATOR D-4PSU 24 2) Wiring a) Wiring method and cautions The terminal block for external connection is provided in the lower portion of the rear face. and never use unused terminals for any external lines. Otherwise, the unit may be damaged. Separate the wiring of the strong electric system from the wiring of the weak electric system, and avoid common grounding. Otherwise, noise may be superimposed on the wiring of the weak electric system, and malfunction may be caused. If the wiring is too long and excessive wires are present, do not put excessive wires into the case of the tension controller. Otherwise, malfunction ever lay the AC power cable on the panel surface. Otherwise, malfunction make valid the variable on the panel surface, and make invalid the input signal for control. status The output setting described in 4-4)-a) remains valid. 4) Changeover of output display The output voltage () or output percentage () is displayed on the 7-segment display [6]. Press the display selector [8] to alternately select the output voltage () and output percentage (). Screw hole dimension for mounting on floor b) Installation on panel surface 38 or less or less 9 4-M4 Panel cut dimension for mounting on panel surface 162 4-4 12 Mounting screw The unit is fixed from rear face with pressure welding and fixing screws. * Metal plate Preform the grounding in either position marked with *. When installing the unit on the floor surface or wall surface, use accessory screws for fixing the main body and the plate. Screws of 1 mm or more in length cannot be used because contact may occur inside the main body. Tightening torque:. to.8 m Perform grounding (grounding resistance : 1 Ω or less) to the casing using the mounting plate fixing screw area when installing the unit on the floor surface or using the mounting plate fixing screw holes (marked with * ) when installing the unit on the panel surface. 1 4 221 + 47 Terminal block (with terminal cover) Terminal block area Use crimp style terminals having the dimensions shown on the right. Set the terminal tightening torque to. to.8 m, M3 and securely tighten each terminal to prevent a cause of malfunction. Perform grounding (grounding resistance: 1 Ω or less) using a shielding wire on the signal receiving side for the analog signal input and output lines and spool pulse input line. ever put the input and output lines together with other power lines into a same duct. ever bundle the input and output lines together with other power lines. ever tighten two wires together on the terminal block. Otherwise, the terminal block may fail. (When tightening two wires together, attach two wires to one terminal, and attach one wire to the terminal block.) Generally, set the wiring length to 1 m or less to assure safety against noise. 6. or less 6. or less <> ote that the knob may be damaged if load is applied on the panel surface facing downward during wiring to the terminal block. electrical shock or damage in the unit Perform grounding (grounding resistance : 1 Ω or less) to the grounding terminal or casing sheet metal area of the unit using a wire of 2 mm 2 or more. Otherwise, electrical shock Use the wire size suitable to the current capacity in wiring. If a wire having smaller current capacity is used, the insulation sheath will be melted and insulation will become defective. In this situation, electrical shock or short-circuit may occur, and fire may occur also. Make sure to attach the terminal cover offered as an accessory of the unit to prevent electrical shock before supplying the power after the wiring work. ote: This manual power supply unit is electronic equipment equipped with a built-in micro computer (CPU). If conductive substances enter the main body or if the CPU becomes out of order due to abnormal noise entered from the outside, the output from the unit is fixed. When the cause is noise, remove the noise source, turn off the power, and then turn on the power to recover the unit to the normal status. b) Wiring of an external variable Wire an external knob using four-core shielding wires as shown in the figure below. Do not ground External variable the terminal + together with D-4PSU the [ ] terminal. Separately ground the terminal. c) Power This unit is not equipped with the power /. It is recommended to connect a or breaker outside the unit. 3. Operations and Functions during Operation 1) ersion display When the power is turned on, the version is displayed on the 7-segment display for 2 seconds. 2) Adjustment of the output voltage a) Adjustment using the variable on the panel surface The output voltage can be adjusted within the range from "" to the maximum value using the voltage adjusting variable [1]. (Maximum output voltage = 26 ) b) Adjustment using an external variable The output voltage can be adjusted using an external variable described in 2-2)-b) by pressing and holding the as described in 3-3) below. 3) Changeover of output voltage adjustment between the variable on the panel surface and the input signal for control In the output status in the normal mode, press and hold the [11] for 1 to light the [] indicator ED [1], make invalid the knob on the panel surface, and make valid the input signal for control (-). Press and hold the [11] again for 1 second or more to extinguish the [] indicator ED [1], ) / function a) Use the output / [1] on the panel surface or [] signal to set the output to or. When the [] signal is set to, the output is generated without regard to the setting of the output / [1] on the panel surface. When the [] signal is set to, the output / [1] on the panel surface becomes valid. Every time the output / is pressed, the output is set to " " alternately. While the output is, the output indicator ED [14] is lit. [] signal / b) In the output condition, the output voltage set in the "output setting" in the adjustment mode is output. setting range : to 1--------- Initial value = While the output is, flickers on the 7- segment display [6]. While the output setting is not set to "", output setting 1. OFS flickers. 6) Inertia compensation function During the "stop timer" setting period after the [] signal is set to from, the output set in "stop output" is generated. Stop timer setting range :. to 9.9 s,1. to 3. s-- Initial value =. s setting range : to 1 ---------------------- Initial value = 7) oad short-circuit protection function When the load between the and terminals is short-circuited, the output is shut down. At this time, [] is displayed on the 7-segment display [6], and [] and the overcurrent detection indicator ED [4] flicker alternately. When the overcurrent detection indicator ED [4] lights, check the external wiring and release the short-circuit status. After releasing the short-circuit status, turn off the power, wait for 3 seconds or more, and then turn on the power to recover the unit to the normal status. Stop timer

4. Adjustment 1) Screen changeover method voltage display check mode voltage display display [] (pressed for 1 sec. or more) o operation for 1 secs. o display operation for secs. Adjustment mode 1. setting 2. setting 3. Stop timer setting 2) Changeover to the adjustment mode While the power is, press and hold the [] [2] for 1 to select the adjustment mode. At this time, the adjustment mode indicator ED [3] lights. The output voltage value just before changeover to the adjustment mode is maintained. If the voltage adjusting variable [1] or an external variable is turned after the adjustment mode is selected, the output voltage changes accordingly. However, the value after change is not displayed on the 7-segment display [6]. When the adjustment mode is finished, the output voltage value or output percentage value after change is displayed. For finishing the adjustment mode, press and hold the [] [2] again for 1. Press the display selector in the adjustment mode to display the present output. (ote) If any is not pressed for 1 seconds or more after the adjustment mode is selected, the normal mode is automatically selected. 3)Functions of the s on the panel surface ----------- In the adjustment mode, each has the following function. [] [2] Press and hold this for 1 in the normal mode to select the adjustment mode. When the adjustment mode is selected, the adjustment mode indicator ED [3] lights. For selecting the normal mode after setting of the parameters is completed, press and hold this for 1. [ ] [12] Use this for selecting either of the adjustment items 1 to 3 in the adjustment mode. Every time this is pressed, the adjustment item o. is changed in the order "3 2 1". After selecting an adjustment item, press this to increase the set Press and hold this for 2 seconds or more to automatically increase the set [ ] [13] Use this for selecting either of the adjustment items 1 to 3 in the adjustment mode. Every time this is pressed, the adjustment item o. is changed in the order "1 2 3". After selecting an adjustment item, press this to decrease the set Press and hold this for 2 seconds or more to automatically decrease the set [11] After selecting an adjustment item, press this to determine the selected adjustment item and enable setting of a numeric After setting a numeric value, press this to store the set value and return to the adjustment item selection status. [ ] [8] Press this once in the adjustment mode to change over the display contents on the 7-segment display between the output voltage () monitoring and the output voltage adjustment () monitoring. If any is not pressed for seconds in the monitoring display status, the display contents automatically return to the status just before the display selector is pressed. At this time, if the display selector is in the numeric value setting status, the numeric value being set is canceled. If the display selector is pressed again in the monitoring display status, the output voltage () monitoring and output voltage adjustment () monitoring are changed over alternately every time the display selector is pressed. [] [14] This turns on and off the output voltage between the and terminals. Every time this is pressed, the output is set to " " alternately. The signal input has higher priority. Even if this is set to "output ", the output is while the signal input is. 4) Adjustment method----------- Press and hold the [] [2] for 1 to select the adjustment mode, and then set the value of each item described below. a) OFS (output ) setting Set the voltage output while the output is set to (while the ED [14] is extinguished). When the output is set to using the procedure described in 3-3), the voltage set here is output. This function can be used for setting the weak exciting voltage of the powder clutch while the output is. Setting range------- to 1 --------- Initial value = (1 = Maximum output voltage, approx. 26 ) [1] Select "1. OFS" using the [ ] [12] or [ ] [2] Press the [11] to determine the item o. 1. [3] Set a numeric value using the [ ] [12] or [ ] [4] Press the [11] to determine the numeric b) O (stop output) setting Set the voltage output while the stop timer is operating. Setting range------- to 1---------- Initial value = (1 = Maximum output voltage 26 ) [1] Select "2. O" using the [ ] [12] or [ ] [2] Press the [11] to determine the item o. 2. [3] Set a numeric value using the [ ] [12] or [ ] [4] Press the [11] to determine the numeric c) T (stop timer) setting Set the stop timer. Setting range-------. to 9.9 s and 1. to 3. s ------------Initial value =. s [1] Select "3. T" using the [ ] [12] or [ ] [2] Press the [11] to determine the item o. 3. [3] Set a numeric value using the [ ] [12] or [ ] [4] Press the [11] to determine the numeric ) Set item list Setting range Set item Unit Minimum value Maximum value Initial value setting 1 1 Stop timer sec. 3... Setting Initialization If the [ ] [12] and [ ] [13] are pressed at the same time when the power is turned on, "InIT" is displayed for 1 seconds on the 7-segment display [6]. The version is not displayed. Press the [11] while "InIT" is displayed to initialize various settings and return the unit to the status at the time of shipment. At this time, the "" unit indicator ED [7] and "" unit indicator ED [9] are extinguished, and only the power indicator ED [] is lit. When initialization is completed, the version flickers for seconds, the normal mode, voltage monitoring display and output status are selected, and then the power indicator ED [] and voltage indicator ED [7] light. If the [11] is not pressed, "InIT" flickers for 1 seconds, and then the normal mode is selected in the same way as the usual power method. Turn on the power press ing [ ] and [ ] Settings are initialized. o operation Display for 3 secs. ersion flickers for secs. status

1 RE MOTE 6. Inspection and Maintenance 1) Initial inspection a) Before turning on the power, check whether the applied load is proper (24 DC, 3.8 A or less). b) Incorrect connection of the power terminal, contact between the DC input/ output wiring and the power wiring, short-circuit of the output wiring, etc. can cause serious damage in the equipment. c) Before turning on the power, check whether the power supply is connected correctly, whether the grounding terminal is connected correctly, and whether the input/output wiring is performed correctly. d) Check whether the commutation diode is not directly connected to the exciting coil of the clutch or brake connected to the control output terminal, and whether the and terminals are not short-circuited. e) Take care so that wire chips and lead wire chips do not enter from ventilation holes on the case top face and sides during wiring. f) To the power indicator ED[], the power is supplied from the secondary circuit of the internal ing power supply. 2) Maintenance inspection a) Consumable parts which can reduce the life of the unit are not built in the unit. However, the standard replacement frequency of the aluminum electrolytic capacitor is years. This frequency varies depending on the ambient working temperature, output current, operating time, etc. Contact Mitsubishi System Services if necessary. b) The life of the EEPROM for storing various setting data is 1, times of writing. The number of times of power / is limited to 1, times or less. c) In the periodic inspection, check the following items: Whether the temperature inside the panel is not normally high due to heating devices and direct sunlight Whether dusts and conductive dusts have not entered the panel Whether abnormality in the wiring, loose terminals and other abnormalities are not present 2) Environmental specificationsl Ambient temperature Ambient humidity ibration resistance Impact resistance Supply noise resistance Withstand voltage Insulation resistance Operating atmosphere 8. Outside Dimensions 18 - ~ + c 3 ~ 8 RH or less ( no condensation) In accordance with JIS C4. 1 to Hz,.mm (4. 9m / s 2 maximum), 2 hours in each of three axis directions In accordance with JIS C41. 98m / s 2, 3 times in each of three axis directions. By noise simulator with 1, p-p noise voltage, 1 µs noise width and 3 to 1 Hz. 1, AC, 1 minute grounding terminal) and ground terminal. grounding terminal) and metal fixture. MΩ or more by DC megger Between entire terminals as a whole and ground terminal. (1Ωor less) Corrosive gas, combustible gas, conductive dusts and many dusts shall not be present. 112 9. External wiring diagram and terminal arrangement AC1 24 +1-1 /6Hz (1Ω or less) External variable (1Ω or less) / + Switching power supply 2 A 12 Phot ocoupler 2.2 kω Overcurrent detection voltage adjusting variable ariable changeover 12 / setteing.1ω + DC24 3.8 A Powder Hysteresis Connect the active line side to the [ ] terminal, and connect the non-active line side to the [ ] terminal. 7. Specifications PO WER REG UATO R D -4PSU 1) I/O specifications Terminal Item name Power supply Contact signal Analog singal + Specifications 1 to 24 AC (-1 to +1), /6 Hzo Power consumption : 2 A (at 24 DC, 3.8A) Power factor : 8 Power fuse : 2, A x1, built in Rush current : 3A, 3ms (depending on line impedance) Allowable instantaneous power interruption :1 ms Power supply for external variable DC 1mA or less remote control = is generated. = is stopped. (Depending on output OFS setting) signal for control : to DC Relay terminal for shield grounding DC12/mA Supplied internally For 24 DC series powder clutch/brake or hysteresis clutch/brake to 24 DC, 3.8 A or less O TAG E ADJ. 1 24 Weight : Approx. 3kg 2(max) on installation and wiring ever apply voltage exceeding 24 AC (38 AC or 4 AC, for example) to the area between the and terminals. Otherwise, the unit may be damaged, or an accident such as fire may be caused. 4 7

1 JZ99D4121A AMPIFIRE AMPIFIRE TYPE D-4PSU ZJ-46A ISTRUCTI MAUA Manual number JZ99D4121 Sub number A Date of preparation ov. 2 Thoroughly read this instruction manual, and then use the unit correctly. Especially, make sure to read "s on Safety" before using the unit. Carefully store this instruction manual, and see to it that the end user receives it. This printed matter is issued in March 2. The specifications are subject to change without prior notice. on installation and wiring electrical shock or damage in the unit Perform grounding (grounding resistance :1 Ω or less) to the grounding terminal or casing sheet metal area of the unit using a wire of 2 mm 2 or more. Otherwise, electrical shock on installation and wiring Separate the wiring of the strong electric system from the wiring of the weak electric system, and avoid common grounding. Otherwise, noise may be superimposed on the wiring of the weak electric system, and malfunction may be caused. and never use unused terminals for any external lines. Otherwise, the unit may be damaged. Installation and environment 1. Functions and Features The power amplifire D-4PSU is designed only for powder clutches/brakes and hysteresis clutches/brakes. This power amplifire operates in a wide power range of 8 to 264 AC, and is equipped with built-in control outputs of 24 DC/3.8 A. 1) Features (1) Switching regulator method (2) Operates in a wide power range of 8 to 264 AC. (3) Constant voltage control method (4) External control signal (: Remote control / input) () Digital display (4-digit, 7-segment ED) (6) for external variable (: Analog signal input) (7) Protection against load short-circuit and short-circuit warning indication (-ED) (8) two-step ing function (9) Power factor of 8 or more [1] oltage adjusting variable [2] [] --Changes over the adjustment mode. [3] Adjustment mode indicator ED (green) [4] Overcurrent detection indicator ED (red) [] Power indicator ED (green) [6] 7-segment display [7] oltage indicator ED (red) [8] voltage ()/output percentage () display selector [9] percentage () indicator ED (red) [1] External variable validity indicator ED (green) [11] -----Determines data setting. [12] [ ] [13] [ ] [14] indicator ED (green) [1] / selector 2. Installation and Wiring s on Safety (Make sure to read this paragraph before using the unit.) Make sure to thoroughly read this instruction manual, technical data, etc. before using the unit, and pay attention to assure safety while using the unit. In this manual, cautions on safety are classified into "DA- GER" and "CAUTI". of death or serious injury is expected. of medium or slight injury is expected or property damage exclusively is expected. Even an item is classified as "CAUTI", its contents are important and it may lead to a serious result depending on the situation. Make sure to observe every item. The unit is manufactured under severe quality control system. When applying the unit to a facility where a failure of the unit may lead to a serious accident or loss, however, systematically install the backup or fail-safe function. Carefully store this instruction manual so that it can be referred to at any time if necessary, and see to it that the end user receives it. on design Set up the emergency stop circuit independently outside this power supply unit. Otherwise, the machine may become out of order and an accident may occur when malfunction occurs in the power supply unit. Use the wire size suitable to the current capacity in wiring. If a wire having smaller current capacity is used, the insulation sheath will be melted and insulation will become defective. In this situation, electrical shock or short-circuit may occur, and fire may occur also. ever use the unit in an atmosphere having danger of inflammation or explosion. Otherwise, inflammation or explosion ever modify nor disassemble the unit. Otherwise, the unit may fail, or an accident such as fire and damage ever drop cutting chips and wire chips while tapping screw holes and performing wiring. Cutting chips and wire chips may cause damage in the unit, fume, fire, malfunction or others. When disposing of the unit, handle it as industrial waste. Installation and environment ever install the unit in a place where dusts, soot, conductive dusts or corrosive gas is present or a place exposed to high temperature, condensation or wind and rain. ever install the unit directly in a place where vibration or impact is applied. Otherwise, the unit may be damaged, malfunction or be deteriorated. on operation ever touch a or with wet hand. Otherwise, electrical shock ever supply the power to the unit nor operate the unit while the main body panel, terminal cover, etc. are open. While the panel or cover is open, a high voltage area may be exposed and electrical shock We shall not be responsible for any damage caused by repair, disassembly, modification, etc. performed by a third party other than or a company specified by. Accordingly, ask a service network specified by for repairs and disassemblies. The above cautions on safety and the specifications described in the instruction manual and technical data are subject to change without prior notice. 2) Major applications (1) Manual power supply unit controlled through the variable on the panel surface. (2) Manual power supply unit controlled through an external variable. The output can be adjusted using an external variable when the variable provided on the panel surface is made invalid and a variable of to 2kΩ (1/2 W or more) is connected to the output terminal () and input terminal (-). (3) Power amplifier using an external voltage signal The output can be adjusted using an external voltage signal when the variable provided on the panel surface is made invalid and the voltage of to is input to the input terminal (-). (4) two-step ing function The output in the output condition can be adjusted within the range from to 1. The output can be ed in two steps using a knob or an external voltage signal. 3) Panel configuration REGUATOR D -4PSU [6] [7] [8] [] [4] [3] [2] [1 ] OTAGE ADJ. 1 [9] [1] [11] [12 ] [13] [14] [1] 1) Installation ever drop cutting chips and wire chips while tapping screw holes and performing wiring. Cutting chips and wire chips may cause damage in the unit, fume, fire, malfunction or others. Make sure to turn off all phases of the external power supply before starting the installation and wiring works. Otherwise, electrical shock or damage in the unit ever install the unit in a place where dusts, soot, conductive dusts or corrosive gas is present or a place exposed to high temperature, condensation or wind and rain. ever install the unit directly in a place where vibration or impact is applied. Otherwise, the unit may be damaged, malfunction or be deteriorated. This power amplifire can be installed on the floor surface or panel surface. ever install the unit in such a manner that the panel surface of the main body faces upward or downward. a) Installation on floor surface OTAGE ADJ. REGUATOR D-4PSU 24 2) Wiring a) Wiring method and cautions The terminal block for external connection is provided in the lower portion of the rear face. and never use unused terminals for any external lines. Otherwise, the unit may be damaged. Separate the wiring of the strong electric system from the wiring of the weak electric system, and avoid common grounding. Otherwise, noise may be superimposed on the wiring of the weak electric system, and malfunction may be caused. If the wiring is too long and excessive wires are present, do not put excessive wires into the case of the tension controller. Otherwise, malfunction ever lay the AC power cable on the panel surface. Otherwise, malfunction make valid the variable on the panel surface, and make invalid the input signal for control. status The output setting described in 4-4)-a) remains valid. 4) Changeover of output display The output voltage () or output percentage () is displayed on the 7-segment display [6]. Press the display selector [8] to alternately select the output voltage () and output percentage (). Screw hole dimension for mounting on floor b) Installation on panel surface 38 or less or less 9 4-M4 Panel cut dimension for mounting on panel surface 162 4-4 12 Mounting screw The unit is fixed from rear face with pressure welding and fixing screws. * Metal plate Preform the grounding in either position marked with *. When installing the unit on the floor surface or wall surface, use accessory screws for fixing the main body and the plate. Screws of 1 mm or more in length cannot be used because contact may occur inside the main body. Tightening torque:. to.8 m Perform grounding (grounding resistance : 1 Ω or less) to the casing using the mounting plate fixing screw area when installing the unit on the floor surface or using the mounting plate fixing screw holes (marked with * ) when installing the unit on the panel surface. 1 4 221 + 47 Terminal block (with terminal cover) Terminal block area Use crimp style terminals having the dimensions shown on the right. Set the terminal tightening torque to. to.8 m, M3 and securely tighten each terminal to prevent a cause of malfunction. Perform grounding (grounding resistance: 1 Ω or less) using a shielding wire on the signal receiving side for the analog signal input and output lines and spool pulse input line. ever put the input and output lines together with other power lines into a same duct. ever bundle the input and output lines together with other power lines. ever tighten two wires together on the terminal block. Otherwise, the terminal block may fail. (When tightening two wires together, attach two wires to one terminal, and attach one wire to the terminal block.) Generally, set the wiring length to 1 m or less to assure safety against noise. 6. or less 6. or less <> ote that the knob may be damaged if load is applied on the panel surface facing downward during wiring to the terminal block. electrical shock or damage in the unit Perform grounding (grounding resistance : 1 Ω or less) to the grounding terminal or casing sheet metal area of the unit using a wire of 2 mm 2 or more. Otherwise, electrical shock Use the wire size suitable to the current capacity in wiring. If a wire having smaller current capacity is used, the insulation sheath will be melted and insulation will become defective. In this situation, electrical shock or short-circuit may occur, and fire may occur also. Make sure to attach the terminal cover offered as an accessory of the unit to prevent electrical shock before supplying the power after the wiring work. ote: This manual power supply unit is electronic equipment equipped with a built-in micro computer (CPU). If conductive substances enter the main body or if the CPU becomes out of order due to abnormal noise entered from the outside, the output from the unit is fixed. When the cause is noise, remove the noise source, turn off the power, and then turn on the power to recover the unit to the normal status. b) Wiring of an external variable Wire an external knob using four-core shielding wires as shown in the figure below. Do not ground External variable the terminal + together with D-4PSU the [ ] terminal. Separately ground the terminal. c) Power This unit is not equipped with the power /. It is recommended to connect a or breaker outside the unit. 3. Operations and Functions during Operation 1) ersion display When the power is turned on, the version is displayed on the 7-segment display for 2 seconds. 2) Adjustment of the output voltage a) Adjustment using the variable on the panel surface The output voltage can be adjusted within the range from "" to the maximum value using the voltage adjusting variable [1]. (Maximum output voltage = 26 ) b) Adjustment using an external variable The output voltage can be adjusted using an external variable described in 2-2)-b) by pressing and holding the as described in 3-3) below. 3) Changeover of output voltage adjustment between the variable on the panel surface and the input signal for control In the output status in the normal mode, press and hold the [11] for 1 to light the [] indicator ED [1], make invalid the knob on the panel surface, and make valid the input signal for control (-). Press and hold the [11] again for 1 second or more to extinguish the [] indicator ED [1], ) / function a) Use the output / [1] on the panel surface or [] signal to set the output to or. When the [] signal is set to, the output is generated without regard to the setting of the output / [1] on the panel surface. When the [] signal is set to, the output / [1] on the panel surface becomes valid. Every time the output / is pressed, the output is set to " " alternately. While the output is, the output indicator ED [14] is lit. [] signal / b) In the output condition, the output voltage set in the "output setting" in the adjustment mode is output. setting range : to 1--------- Initial value = While the output is, flickers on the 7- segment display [6]. While the output setting is not set to "", output setting 1. OFS flickers. 6) Inertia compensation function During the "stop timer" setting period after the [] signal is set to from, the output set in "stop output" is generated. Stop timer setting range :. to 9.9 s,1. to 3. s-- Initial value =. s setting range : to 1 ---------------------- Initial value = 7) oad short-circuit protection function When the load between the and terminals is short-circuited, the output is shut down. At this time, [] is displayed on the 7-segment display [6], and [] and the overcurrent detection indicator ED [4] flicker alternately. When the overcurrent detection indicator ED [4] lights, check the external wiring and release the short-circuit status. After releasing the short-circuit status, turn off the power, wait for 3 seconds or more, and then turn on the power to recover the unit to the normal status. Stop timer

1 RE MOTE 4. Adjustment 1) Screen changeover method voltage display check mode voltage display display [] (pressed for 1 sec. or more) o operation for 1 secs. o display operation for secs. Adjustment mode 1. setting 2. setting 3. Stop timer setting 2) Changeover to the adjustment mode While the power is, press and hold the [] [2] for 1 to select the adjustment mode. At this time, the adjustment mode indicator ED [3] lights. The output voltage value just before changeover to the adjustment mode is maintained. If the voltage adjusting variable [1] or an external variable is turned after the adjustment mode is selected, the output voltage changes accordingly. However, the value after change is not displayed on the 7-segment display [6]. When the adjustment mode is finished, the output voltage value or output percentage value after change is displayed. For finishing the adjustment mode, press and hold the [] [2] again for 1. Press the display selector in the adjustment mode to display the present output. (ote) If any is not pressed for 1 seconds or more after the adjustment mode is selected, the normal mode is automatically selected. 3)Functions of the s on the panel surface ----------- In the adjustment mode, each has the following function. [] [2] Press and hold this for 1 in the normal mode to select the adjustment mode. When the adjustment mode is selected, the adjustment mode indicator ED [3] lights. For selecting the normal mode after setting of the parameters is completed, press and hold this for 1. [ ] [12] Use this for selecting either of the adjustment items 1 to 3 in the adjustment mode. Every time this is pressed, the adjustment item o. is changed in the order "3 2 1". After selecting an adjustment item, press this to increase the set Press and hold this for 2 seconds or more to automatically increase the set [ ] [13] Use this for selecting either of the adjustment items 1 to 3 in the adjustment mode. Every time this is pressed, the adjustment item o. is changed in the order "1 2 3". After selecting an adjustment item, press this to decrease the set Press and hold this for 2 seconds or more to automatically decrease the set [11] After selecting an adjustment item, press this to determine the selected adjustment item and enable setting of a numeric After setting a numeric value, press this to store the set value and return to the adjustment item selection status. [ ] [8] Press this once in the adjustment mode to change over the display contents on the 7-segment display between the output voltage () monitoring and the output voltage adjustment () monitoring. If any is not pressed for seconds in the monitoring display status, the display contents automatically return to the status just before the display selector is pressed. At this time, if the display selector is in the numeric value setting status, the numeric value being set is canceled. If the display selector is pressed again in the monitoring display status, the output voltage () monitoring and output voltage adjustment () monitoring are changed over alternately every time the display selector is pressed. [] [14] This turns on and off the output voltage between the and terminals. Every time this is pressed, the output is set to " " alternately. The signal input has higher priority. Even if this is set to "output ", the output is while the signal input is. 4) Adjustment method----------- Press and hold the [] [2] for 1 to select the adjustment mode, and then set the value of each item described below. a) OFS (output ) setting Set the voltage output while the output is set to (while the ED [14] is extinguished). When the output is set to using the procedure described in 3-3), the voltage set here is output. This function can be used for setting the weak exciting voltage of the powder clutch while the output is. Setting range------- to 1 --------- Initial value = (1 = Maximum output voltage, approx. 26 ) [1] Select "1. OFS" using the [ ] [12] or [ ] [2] Press the [11] to determine the item o. 1. [3] Set a numeric value using the [ ] [12] or [ ] [4] Press the [11] to determine the numeric b) O (stop output) setting Set the voltage output while the stop timer is operating. Setting range------- to 1---------- Initial value = (1 = Maximum output voltage 26 ) [1] Select "2. O" using the [ ] [12] or [ ] [2] Press the [11] to determine the item o. 2. [3] Set a numeric value using the [ ] [12] or [ ] [4] Press the [11] to determine the numeric c) T (stop timer) setting Set the stop timer. Setting range-------. to 9.9 s and 1. to 3. s ------------Initial value =. s [1] Select "3. T" using the [ ] [12] or [ ] [2] Press the [11] to determine the item o. 3. [3] Set a numeric value using the [ ] [12] or [ ] [4] Press the [11] to determine the numeric ) Set item list Setting range Set item Unit Minimum value Maximum value Initial value setting 1 1 Stop timer sec. 3... Setting Initialization If the [ ] [12] and [ ] [13] are pressed at the same time when the power is turned on, "InIT" is displayed for 1 seconds on the 7-segment display [6]. The version is not displayed. Press the [11] while "InIT" is displayed to initialize various settings and return the unit to the status at the time of shipment. At this time, the "" unit indicator ED [7] and "" unit indicator ED [9] are extinguished, and only the power indicator ED [] is lit. When initialization is completed, the version flickers for seconds, the normal mode, voltage monitoring display and output status are selected, and then the power indicator ED [] and voltage indicator ED [7] light. If the [11] is not pressed, "InIT" flickers for 1 seconds, and then the normal mode is selected in the same way as the usual power method. Turn on the power press ing [ ] and [ ] Settings are initialized. o operation Display for 3 secs. ersion flickers for secs. status 6. Inspection and Maintenance 1) Initial inspection a) Before turning on the power, check whether the applied load is proper (24 DC, 3.8 A or less). b) Incorrect connection of the power terminal, contact between the DC input/ output wiring and the power wiring, short-circuit of the output wiring, etc. can cause serious damage in the equipment. c) Before turning on the power, check whether the power supply is connected correctly, whether the grounding terminal is connected correctly, and whether the input/output wiring is performed correctly. d) Check whether the commutation diode is not directly connected to the exciting coil of the clutch or brake connected to the control output terminal, and whether the and terminals are not short-circuited. e) Take care so that wire chips and lead wire chips do not enter from ventilation holes on the case top face and sides during wiring. f) To the power indicator ED[], the power is supplied from the secondary circuit of the internal ing power supply. 2) Maintenance inspection a) Consumable parts which can reduce the life of the unit are not built in the unit. However, the standard replacement frequency of the aluminum electrolytic capacitor is years. This frequency varies depending on the ambient working temperature, output current, operating time, etc. Contact Mitsubishi System Services if necessary. b) The life of the EEPROM for storing various setting data is 1, times of writing. The number of times of power / is limited to 1, times or less. c) In the periodic inspection, check the following items: Whether the temperature inside the panel is not normally high due to heating devices and direct sunlight Whether dusts and conductive dusts have not entered the panel Whether abnormality in the wiring, loose terminals and other abnormalities are not present 2) Environmental specificationsl Ambient temperature Ambient humidity ibration resistance Impact resistance Supply noise resistance Withstand voltage Insulation resistance Operating atmosphere 8. Outside Dimensions 18 - ~ + c 3 ~ 8 RH or less ( no condensation) In accordance with JIS C4. 1 to Hz,.mm (4. 9m / s 2 maximum), 2 hours in each of three axis directions In accordance with JIS C41. 98m / s 2, 3 times in each of three axis directions. By noise simulator with 1, p-p noise voltage, 1 µs noise width and 3 to 1 Hz. 1, AC, 1 minute grounding terminal) and ground terminal. grounding terminal) and metal fixture. MΩ or more by DC megger Between entire terminals as a whole and ground terminal. (1Ωor less) Corrosive gas, combustible gas, conductive dusts and many dusts shall not be present. 112 9. External wiring diagram and terminal arrangement AC1 24 +1-1 /6Hz (1Ω or less) External variable (1Ω or less) / + Switching power supply 2 A 12 Phot ocoupler 2.2 kω Overcurrent detection voltage adjusting variable ariable changeover 12 / setteing.1ω + DC24 3.8 A Powder Hysteresis Connect the active line side to the [ ] terminal, and connect the non-active line side to the [ ] terminal. 7. Specifications PO WER REG UATO R D -4PSU 1) I/O specifications Terminal Item name Power supply Contact signal Analog singal + Specifications 1 to 24 AC (-1 to +1), /6 Hzo Power consumption : 2 A (at 24 DC, 3.8A) Power factor : 8 Power fuse : 2, A x1, built in Rush current : 3A, 3ms (depending on line impedance) Allowable instantaneous power interruption :1 ms Power supply for external variable DC 1mA or less remote control = is generated. = is stopped. (Depending on output OFS setting) signal for control : to DC Relay terminal for shield grounding DC12/mA Supplied internally For 24 DC series powder clutch/brake or hysteresis clutch/brake to 24 DC, 3.8 A or less O TAG E ADJ. 1 24 Weight : Approx. 3kg 2(max) on installation and wiring ever apply voltage exceeding 24 AC (38 AC or 4 AC, for example) to the area between the and terminals. Otherwise, the unit may be damaged, or an accident such as fire may be caused. 4 7