Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Similar documents
Cylindrical Inductive Proximity Sensor GX-M SERIES

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Not affected by drops, bubbles or froth

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Rectangular-shaped Inductive Proximity Sensor.

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety

EX-F70 SERIES EX-F60 SERIES

High-speed detection even a little liquid leak

GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. GX-12ML(B) Conventional model

CX-20. General Purpose Photoelectric Sensor with Full Basic Performance. SERIES Amplifier Built-in Compact Photoelectric Sensor PHOTOELECTRIC SENSORS

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

GL-6 SERIES. Miniature Inductive Proximity Sensor. High Performance in Surprisingly Small Body. Marked. Extremely Small.

Compact Inductive Proximity Sensor. onlinecomponents.com. Various Applications

SA1W: Water Detection Sensors

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

GXL SERIES. Micro-size Inductive Proximity Sensor. High Performance in Micro-size Design. Marked. Versatile Mounting. Wide Model Variety

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

GXL SERIES. Micro-size Inductive Proximity Sensor. High Performance in Micro-size Design. Marked. Wide Model Variety. Versatile Mounting

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

19mm Thickness. Phone: Fax: Web:

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Inductive Proximity Sensor

EX-F70 SERIES EX-F60 SERIES

SA1A and SA1B: High-Speed, Slim Style Photoelectric Sensors

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Inductive Proximity Sensor

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

High-frequency AC Method. panasonic-electric-works.net/sunx

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

PMS - PKS / PMW - PKW series

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

IP69K: Highly water resistant

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

E2EZ-X2D1-N E2EZ-X2D2-N

DC2-Wire Unshielded Cylindrical Proximity Switches

Indicators reveal the sort of an abnormal condition. Emitter Emitting Controller Power indicator

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

PHOTOELECTRIC S300 PA MAXI SENSORS APPLICATIONS.

Cylindrical type proximity sensor

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations

IP69K: Highly water resistant

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

sensors SA1C-F High-speed Fiber Optic: SA1C-F

Cylindrical photoelectric sensors in M18 plastic or brass housings. Performance and portfolio variety. Metal *1 90 Optics AC power supply *2

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Digital Pressure Sensor with Auto-reference Function. Example of air-leak test. Threshold level. Reference pressure. Reference pressure

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Inductive Proximity Sensor

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

A New Global Standard

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

AC/DC2-wire Type Cylindrical Proximity Switches

Operation mode. Sensing distance N.O. N.C. N.O. N.C. N.O. N.C. 7mm

Sensing & Safety GENERAL CATALOGUE 2004/2005

Inductive Proximity Sensor

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES

PX-2 SERIES. onlinecomponents.com. Compact size sensor realizes wide sensing area & long sensing range. Long Range & Wide Area Photoelectric Sensor

E3ZM-C. Photoelectric Sensor for the Automotive and Machine Tool Industries. Features

Supply Voltage 10-30V DC. (10ms on/off) 10-30V DC. (1ms on/off) 10-30V DC. (10ms on/off) 10-30V DC. (1ms on/off) 10-30V DC. (10ms on/off) 10-30V DC

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

QD Series Mini Photoelectric Switch

ISF: Heavy Duty Photoelectric Sensors

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in)

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

Photoelectric Sensors 55 Series

FL7MSeries. DC2-Wire Regular Cylindrical Proximity Sensors

MINI-BEAM SM312CV and SM312CV2

2-Color Display High-Precision Digital Pressure Switch

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

Cylindrical Proximity Sensor

DC2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors N.O. N.C. N.O. N.C. N.O. N.C. 8mm N.O. N.C. N.O. N.O. N.C. N.O. N.O. N.C.

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

Series ISA. Air Catch Sensor. For Detection of Work Presence

2 Window comparator mode. Hysteresis Hysteresis

2-Color Display High-Precision Digital Pressure Switch

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

Related vacuum products

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Transcription:

Cylindrical Sensors Photoelectric Sensor CY-100 SERIES Inductive Proximity Sensor GX-M SERIES Listing (2 m cable length type only) Cylindrical Inductive Proximity Sensor GX-M SERIES Cylindrical Photoelectric Sensor CY-100 SERIES 2011.11 panasonic-electric-works.net/sunx

Cylindrical Photoelectric Sensor CY-100 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M12 plug-in connector type Diffuse reflective type sensor with sensitivity adjuster is available. M18 thread size for convenient mounting Strong resistance IP67 Convenient universal sensor mounting stand is available. ORDER GUIDE 2 m cable length type Standard Side view Type Appearance Sensing range Retroreflective Diffuse reflective Retroreflective Diffuse reflective (Note 2.3) With polarizing filters With sensitivity adjuster Thrubeam Thrubeam (Note 2.3) With polarizing filters With sensitivity adjuster 2 m 6.56 ft 100 mm 0.33 ft 600 mm 1.97 ft 2 m 6.56 ft 100 mm 3.94 in 600 mm 23.62 in 15 m 49.21 ft 4 m 13.12 ft 15 m 49.21 ft 4 m 13.12 ft NPN output Model No. (Note 1) PNP output Output operation CY-111A CY-111A-P Light-ON CY-111B CY-111B-P Dark-ON CY-192A-Y CY-192A-P-Y Light-ON CY-192B-Y CY-192B-P-Y Dark-ON CY-191A-Y CY-191A-P-Y Light-ON CY-191B-Y CY-191B-P-Y Dark-ON CY-121A CY-121A-P Light-ON CY-121B CY-121B-P Dark-ON CY-122A CY-122A-P Light-ON CY-122B CY-122B-P Dark-ON CY-111VA CY-111VA-P Light-ON CY-111VB CY-111VB-P Dark-ON CY-192VA-Y CY-192VA-P-Y Light-ON CY-192VB-Y CY-192VB-P-Y Dark-ON CY-191VA-Y CY-191VA-P-Y Light-ON CY-191VB-Y CY-191VB-P-Y Dark-ON CY-121VA CY-121VA-P Light-ON CY-121VB CY-121VB-P Dark-ON CY-122VA CY-122VA-P Light-ON CY-122VB CY-122VB-P Dark-ON Notes: 1) The model No. with E shown on the label affixed to the thru-beam type sensor is the emitter, D shown on the label is the receiver. (e.g.) Emitter of CY-111A: CY-111E, Receiver of CY-111A: CY-111AD 2) The retlector is sold separately. 3) The sensing range of the retroreflective type sensor is specified for the RF-420 reflector (optional). M12 plug-in connector type M12 plug-in connector type is also available. When ordering this type, -Z for the M12 plug-in connector type to the model No. (e.g.) M12 plug-in connector type of CY-111A-P is CY-111A-P-Z. Standard type Side view type 1

Cylindrical Photoelectric Sensor CY-100 SERIES ORDER GUIDE Mating cable (2 cables are required for the thru-beam type.) For M12 plug-in connector type Type Model No. Description Straight Elbow CN-24C-C2 CN-24C-C5 CN-24CL-C2 CN-24CL-C5 Length: 2 m 6.56 ft Length: 5 m 16.40 ft Length: 2 m 6.56 ft Length: 5 m 16.40 ft Clamping ring : ø14mm 0.55 in Cable outer : ø5.3mm 0.21 in Mating cable Straight type Elbow type OPTIONS Designation Model No. Description Sensor mounting bracket Sensor mounting bracket MS-CY1-1 MS-CY1-2 Material: Stainless steel Material: Plastic, For beam axis alignment MS-CY1-1 MS-CY1-2 Universal sensor mounting stand MS-AJ3 It can adjust the height of the sensor and reflector RF-420. (The thru-beam type sensor needs two brackets.) Reflector RF-420 RF-410 50 50 mm 1.97 1.97 in 24 21 mm 0.94 0.83 in Reflective tape RF-40RL5 22 mm 5 m 0.87 196.85 in, Thickness: 0.4 mm 0.02 in Universal sensor mounting stand MS-AJ3 Reflector RF-420 RF-410 Reflective tape RF-40RL5 WIRING DIAGRAMS Wiring diagram Emitter of thru-beam type Receiver of thru-beam / Reflective type NPN output type Receiver of thru-beam / Reflective type PNP output type Connector pin position M12 connector 4 3 1 2 1 : +V 2 : Input (Only emitter of thru-beam type) 3 : 0 V 4 : Output (Only receiver of thru-beam type and reflective type) 2

Cylindrical Photoelectric Sensor CY-100 SERIES SPECIFICATIONS Model No. Type Thru-beam Retroreflective Diffuse reflective With polarizing filters With sensitivity adjuster Standard Side view Standard Side view Standard Side view Standard Side view Standard Side view Light-ON CY-111A CY-111VA CY-192A CY-192VA CY-191A CY-191VA CY-121A CY-121VA CY-122A CY-122VA Item Dark-ON CY-111B CY-111VB CY-192B CY-192VB CY-191B CY-191VB CY-121B CY-121VB CY-122B CY-122VB Sensing range 15 m 49.21 ft 4 m 13.12 ft (Note 2) 2 m 6.56 ft (Note 2) Sensing object ø18 mm ø0.71 in or more opaque object (Setting distance between emitter and receiver: 15 m 49.21ft) ø50 mm ø1.97 in or more opaque, translucent or transparent object (Note 2, 4) ø50 mm ø1.97 in or more opaque, translucent, transparent or specular object (Note 2, 4) 100 mm 3.94 in (Note 3) 600 mm 23.62 in (Note 3) Opaque, translucent or transparent object (Note 4) Hysteresis 3 to 15 % of operation distance (Note 3) Supply voltage Current consumption Emitter: 35 ma or less Receiver: 35 ma or less 12 to 24 V DC ±10 % Ripple P-P 10 % or less 35 ma or less Output Utilization category Short-circuit protection <NPN output type> <PNP output type> NPN open-collector transistor PNP open-collector transistor Maximum sink current: 100 ma Maximum source current: 100 ma Applied voltage: 24 V DC or less (between output and 0 V) Applied voltage: 24 V DC or less (between output and +V) Residual voltage: 1.5 V or less Residual voltage: 1.5 V or less DC-12 or DC-13 Incorporated Response time 1 ms or less Test input (emission halt) function Incorporated Operation indicator Power indicator Pollution degree Green LED (lights up when the power is ON) (incorporated on the emitter) Yellow LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) 3 (Industrial environment) Environmental resistance Protection IP67 (IEC) Ambient temperature 25 to +55 C 13 to +131 F (No dew condensation or icing allowed), Storage: 40 to +70 C 22 to +158 F Ambient humidity 50 % RH (at +70 C +158 F) Ambient illuminance Incandescent light: 5,000 lx at the light-receiving face EMC EN 60947-5-2 Voltage withstandability 500 V AC for one min. between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 0.5 mm 0.02 in amplitude in X, Y and Z directions for 1.5 hours each Shock resistance 294 m/s 2 acceleration (30 G ) in X, Y and Z directions for three times each Emitting element Infrared LED (modulated) Red LED (modulated) Infrared LED (modulated) Peak emission wavelength 890 nm 0.04 mil 875 nm 0.03 mil 665 nm 0.03 mil 875 nm 0.03 mil Material Cable (except for M12 plug-in connection type) Cable extension Net weight (Note 5) 2 m cable length type M12 plug-in connector type Enclosure: PBT, Lens: PMMA 0.44 mm 2 3-core cabtyre cable, 2 m 6.56 ft long Extension up to total 10 m 32.81 ft is possible with 0.34 mm 2, or more, cable (thru-beam type: both emitter and receiver). Emitter/ Receiver: 65 g Emitter/ Receiver: 15 g Emitter/ Receiver: 70 g Emitter/ Receiver: 20 g 65 g 15 g 70 g 20 g 65 g 15 g 70 g 20 g 65 g 15 g 70 g 20 g 75 g 25 g Accessories Nut: 4 pcs. Nut: 2 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-420 reflector (optional). 3) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 200 mm 7.87 7.87 in) as the object. 4) Make sure to confirm detection with an actual sensor before use for detection of the transparent object and the translucent object. 5) The weight includes the weight of nuts. 3

Cylindrical Photoelectric Sensor CY-100 SERIES DETECTION CURVES Thru-beam type Diffuse reflective Diffuse reflective type with adjustable sensitivity Retroreflective type Retroreflective type with polarizing filters in cm 5.91 15-5.91-15 ø 0.49 in ø 12 mm 10 15 0.39 0.59 49.21 ft A 15 m m in cm 0.55 1,4 0.39 1-0.39-1 -0.55-1,4 1.97 5 A 3.94 in 10 cm in 0,59 15 cm in cm 0.55 1.4 0.39 1-0.39-1 -0.55-1.4 23.62 in A 60 cm in 2.62 80 cm in cm 3.94 10 1.57 4-1.57-4 -3.94-10 2 0.79 13.12 ft A 4 m 4 1.57 m ø of beam in cm 2.36 6 1.57 4 0.79 E/R 2-0.79-2 0,2 2 3 0.79 1.18 0.39-1.57-4 -2.36-6 A 6.56 ft 2 m A=Sensing range Object 10 10 cm; 1 White 90%; 2 Grey 18% With reflector RF-420 With reflector RF-420 PRECAUTIONS FOR PROPER USE Mounting The tightening torque should be 3 N m or less. Use a cable with connector CN-24C(L)-C (optional) for M12 connector type. Tightening torque for connector part is 2 N m or less. Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Mounting drawing with sensor or reflector RF-420 Wiring Make sure that the power supply is off while wiring. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. Ensure that an isolation transformer is utilized for the DC power supply. If an autotransformer is utilized, the main body or power supply may be damaged. If the used power supply generates a surge, connect a surge absorber to the power supply to absorb the surge. Do not use during the initial transient time (0.5 sec) after the power supply is switched on. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Damage or burnout may result in case of short circuit of load or miswiring. Make a cable length as short as possible to lessen noise pickup. Others Our products have been developed / produced for industrial use only. Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance. Avoid using a product where there is excessive vapor, dust or corrosive gas, or in a place where it could be exposed directly to water or chemicals. Take care that the sensor does not come in direct contact with water, oil, grease or organic solvents, such as, thinner, etc. Do not use in an environment containing infammable or explosive gases. Never disassemble or modify the product. 4

Cylindrical Photoelectric Sensor CY-100 SERIES DIMENSIONS (Unit: mm in) CY-1 Sensor M18 2 m cable length type (mm in) M12 plug-in connector type (mm in) a b a b a b Standard type CY-111 /121 /192 46 1.81 28 1.10 60 2.36 28 1.10 Standard type CY-191 48 1.89 28 1.10 62 2.44 28 1.10 Side view type CY-111V /121V /191V /192V 62 2.44 28 1.10 76 2.99 28 1.10 Standard type CY-122 62 2.44 44 1.73 76 2.99 44 1.73 Side view type CY-122V 78 3.07 44 1.73 92 3.62 44 1.73 CN-24C-C2 CN-24C-C5 Mating cable CN-24CL-C2 CN-24CL-C5 Mating cable 27 1.06 ø14 ø0.55 Connector pin position BU BK 3 4 M12 1 38 1.50 Connector pin position BU BK 3 4 2 1 L 2 1 L = 2 or 5 m 6.56 or 16.40 ft WH BN L = 2 or 5 m 6.56 or 16.40 ft ø10 ø0.39 WH BN MS-CY1-1 Sensing mounting bracket 2.5 50 ø18.2 0.10 1.97 ø0.72 MS-CY1-2 Sensing mounting bracket 10 45 ø18.2 0.39 1.77 ø0.72 28 1.10 35 1.38 10 0.39 = = = = 15 0.59 1 0.04 6.5 20 0.26 0.79 6.5 0.26 20 0.79 16.5 0.65 5 0.20 6.5 0.26 55 2.17 8 24 8 0.32 0.94 0.32 = = 19.5 0.77 25 0.98 27 1.06 MS-AJ3 1. Ball-joint mounted fixing bracket CY-100 series or RF-420 2. M12 rod Universal sensor mounting stand 3. Support for M12 rod ø18.5 ø0.73 36 1.42 M4 5.7 0.22 22.9 0.90 40 1.57 40 1.57 76.5 3.01 33 1.30 67 2.64 50 55 1.97 2.17 4.96 126 132 5.20 1.57 40 19 0.75 0.75 19 19 0.75 12 0.47 M12 53 2.09 1.9 0.07 23 0.91 ø6.5 ø0.26 36 1.42 5

DIMENSIONS (Unit: mm in) RF-420 Reflector RF-410 Reflector 35 1.38 2 - ø5.5 ø0.22 4 - R5 R0.20 2 - ø4.5 ø0.18 9 0.35 ø7.5 ø0.30 51 69 47 60 2.01 2.72 1.85 2.36 45 1.77 21 0.83 33 1.30 3.5 8 0.14 0.32 51.5 2.03 8 0.32 ø4.5 ø0.18 4 0.16 7.5 0.30 24 0.94 = = 29 1.14 ø4.5 ø0.18 6

Cylindrical Inductive Proximity Sensor GX-M SERIES Listing (2 m cable length type only) Features Wide product range Types: DC 3-wire shielded type DC 3-wire non-shielded type DC 2-wire standard type DC 2-wire long range type Size: M8, M12, M18, M30 Connector: 2 m cable length type M12 plug-in connector type M12 pigtaild type (DC 2-wire M8 type only) Strong resistance IP68 (GX-M8 : IP67) ORDER GUIDE DC 3-wire type (2 m cable length type) Shielded Non-shielded Type Appearance Sensing range (Note 1,2) M8 M12 M18 M30 M12 M18 M30 Ex.) GX-M12 Ex.) GX-MK12 Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in) Max. operation distance: 2 mm 0.08 in (Stable sensing range 0 to 1.6 mm 0.06 in) Max. operation distance: 5 mm 0.20 in (Stable sensing range 0 to 4 mm 0.16 in) Max. operation distance: 10 mm 0.39 in (Stable sensing range 0 to 8 mm 0.32 in) Max. operation distance: 7 mm 0.28 in (Stable sensing range 0 to 5.6 mm 0.22 in) Max. operation distance: 12 mm 0.47 in (Stable sensing range 0 to 9.6 mm 0.38 in) Max. operation distance: 22 mm 0.87 in (Stable sensing range 0 to 17.6 mm 0.69 in) NPN output Model No. PNP output Output operation GX-M8A GX-M8A-P Normally open GX-M8B GX-M8B-P Normally closed GX-M12A GX-M12A-P Normally open GX-M12B GX-M12B-P Normally closed GX-M18A GX-M18A-P Normally open GX-M18B GX-M18B-P Normally closed GX-M30A GX-M30A-P Normally open GX-M30B GX-M30B-P Normally closed GX-MK12A GX-MK12A-P Normally open GX-MK12B GX-MK12B-P Normally closed GX-MK18A GX-MK18A-P Normally open GX-MK18B GX-MK18B-P Normally closed GX-MK30A GX-MK30A-P Normally open GX-MK30B GX-MK30B-P Normally closed Notes: 1) It is the value in state where the circumference of a detection side has a metal object. 2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 7

Cylindrical Inductive Proximity Sensor GX-M SERIES ORDER GUIDE DC 2-wire type (2 m cable length type) Type Appearance Sensing range (Note 1,2) Model No. Output operation M8 Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in) GX-M8A-U GX-M8B-U Normally open Normally closed Standard M18 M12 Max. operation distance: 2 mm 0.08 in (Stable sensing range 0 to 1.6 mm 0.06 in) Max. operation distance: 5 mm 0.20 in (Stable sensing range 0 to 4 mm 0.16 in) GX-M12A-U GX-M12B-U GX-M18A-U GX-M18B-U Normally open Normally closed Normally open Normally closed M30 Max. operation distance: 10 mm 0.39 in (Stable sensing range 0 to 8 mm 0.32 in) GX-M30A-U GX-M30B-U Normally open Normally closed M8 Max. operation distance: 2.5 mm 0.10 in (Stable sensing range 0 to 2 mm 0.08 in) GX-ML8A-U GX-ML8B-U Normally open Normally closed Long range M18 M12 Ex.) GX-M12 -U Max. operation distance: 4 mm 0.16 in (Stable sensing range 0 to 3.2 mm 0.13 in) Max. operation distance: 8 mm 0.32 in (Stable sensing range 0 to 6.4 mm 0.25 in) GX-ML12A-U GX-ML12B-U GX-ML18A-U GX-ML18B-U Normally open Normally closed Normally open Normally closed M30 Max. operation distance: 15 mm 0.59 in (Stable sensing range 0 to 12 mm 0.47 in) GX-ML30A-U GX-ML30B-U Normally open Normally closed Notes: 1) It is the value in state where the circumference of a detection side has a metal object. 2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. M12 plug-in connector type (except for GX-M8 -U and GX-ML8 -U) M12 plug-in connector type is also available. When ordering this type, -Z for the M12 plug-in connector type to the model No. (e.g.) M12 plug-in connector type of GX-M8A-P is GX-M8A-P-Z. M12 pigtailed type (for GX-M8 -U and GX-ML8 -U only) M12 pigtailed type is also available. When ordering this type, -J for the M12 pigtailed type to the model No. (e.g.) M12 pigtailed type of GX-M8A-U is GX-M8A-U-J. Mating cable (2 cables are required for the thru-beam type.) For M12 plug-in connector type Type Model No. Description Straight Elbow CN-24C-C2 CN-24C-C5 CN-24CL-C2 CN-24CL-C5 Length: 2 m 6.56 ft Length: 5 m 16.40 ft Length: 2 m 6.56 ft Length: 5 m 16.40 ft Clamping ring : ø14mm 0.55 in Cable outer : ø5.3mm 0.21 in Mating cable Straight type Elbow type 8

Cylindrical Inductive Proximity Sensor GX-M SERIES SPECIFICATIONS DC 3-wire type Type Shielded type Non-shielded type Model No. Normally open GX-M8A GX-M12A GX-18A GX-M30A GX-MK12A GX-MK18A GX-MK30A Item Normally closed GX-M8B GX-M12B GX-18B GX-M30B GX-MK12B GX-MK18B GX-MK30B Max. operation distance (Note 2,3) 1.5 mm 0.06 in ±10 % 2 mm 0.08 in ±10 % 5 mm 0.20 in ±10 % 10 mm 0.39 in ±10 % 7 mm 0.28 in ±10 % 12 mm 0.47 in ±10 % 22 mm 0.87 in ±10 % Stable sensing range (Note 2,3) 0 to 1.2 mm 0 to 0.05 in 0 to 1.6 mm 0 to 0.06 in 0 to 4 mm 0 to 0.16 in 0 to 8 mm 0 to 0.32 in 0 to 5.6 mm 0 to 0.22 in 0 to 9.6 mm 0 to 0.38 in 0 to 17.6 mm 0 to 0.69 in Standard sensing object Iron sheet 8 8 t 1 mm 0.32 0.32 t 0.04 in Iron sheet 12 12 t 1 mm 0.47 0.47 t 0.04 in Iron sheet 18 18 t 1mm 0.71 0.71 t 0.04 in Iron sheet 30 30 t 1 mm 1.18 1.18 t 0.04 in Iron sheet 24 24 t 1 mm 0.94 0.94 t 0.04 in Iron sheet 24 24 t 1 mm 0.94 0.94 t 0.04 in Iron sheet 45 45 t 1 mm 1.77 1.77 t 0.04 in Hysteresis (Note 2) Repeatability (Note 2) Supply voltage Current consumption (Note 4) 15 % or less of operation distance (with standard sensing object) Along sensing axis: 5 % or less of operation distance 12 to 24 V DC ±10 % Ripple P-P 10 % or less 10 ma or less Output <NPN output type> NPN open-collector transistor Maximum sink current 200 ma Applied voltage: 24 V DC or less (between output and 0 V) Residual voltage 2 V or less <PNP output type> PNP open-collector transistor Maximum source current 200 ma Applied voltage: 24 V DC or less (between output and + V) Residual voltage 2 V or less Utilization category Short-circuit protection DC-12 or DC-13 Incorporated Max. response frequency 5 khz 5 khz 2 khz 1 khz 2.5 khz 1 khz 0.5 khz Operation indicator Pollution degree Yellow LED (lights up when the output is ON) 3 (industrial enviroment) Environmental resistance Protection IP67 (IEC) IP69K (DIN), IP68 (IEC) (2 m cable length type only), IP67 (IEC) (M12 plug-in connector type only) Ambient temperature 25 to +70 C 13 to +158 F, Storage: 40 to +85 C 40 to +185 F Ambient humidity 50 % RH or less (at +70 C +158 F) EMC EN 60947-5-2 Voltage withstandability 500 V AC for one min. between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 0.5 mm 0.02 in amplitude in X, Y and Z directions for 1.5 hours each Shock resistance Sensing range variation (Note 2) Material Cable (except for M12 plug-in connector type) Cable extension 294 m/s 2 acceleration (30 G ) in X, Y and Z directions for three times each Within ±10 % fluctuation of sensing range at +23 C +73 F and rated voltage in the range of allowable temperature and supply voltage Enclosure: Brass (Nickel plated), Sensing part: PPS 0.44 mm 2 (0.15 mm 2 for GX-M8 ) 3-core cabtyre cable, 2 m 6.56 ft long Extension up to total 10 m 32.80 ft is possible with 0.34 mm 2, or more, cable. Net weight (Note 5) Accessories 2 m cable length type 40 g 70 g 90 g 150 g 75 g 100 g 180 g M12 plug-in connector type 15 g 20 g 45 g 110 g 25 g 55 g 140 g Nut: 2 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2) It is the value in state where the circumference of a detection side has a metal object. 3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 4) It is the leakage current when the output is in the OFF state. 5) The weight includes the weight of two nuts. 9

Cylindrical Inductive Proximity Sensor GX-M SERIES SPECIFICATIONS DC 2-wire type Type Standard type Long range type Model No. Normally open GX-M8A-U(-J) GX-M12A-U(-Z) GX-M18A-U(-Z) GX-M30A-U(-Z) GX-ML8A-U(-J) GX-ML12A-U(-Z) GX-ML18A-U(-Z) GX-ML30A-U(-Z) Item Normally closed GX-M8B-U(-J) GX-M12B-U(-Z) GX-M18B-U(-Z) GX-M30B-U(-Z) GX-ML8B-U(-J) GX-ML12B-U(-Z) GX-ML18B-U(-Z) GX-ML30B-U(-Z) Max. operation distance (Note 2,3) 1.5 mm 0.06 in ±10 % 2 mm 0.08 in ±10 % 5 mm 0.20 in ±10 % 10 mm 0.39 in ±10 % 2.5 mm 0.10 in ±10 % 4 mm 0.16 in ±10 % 8 mm 0.32 in ±10 % 15 mm 0.59 in ±10 % Stable sensing range (Note 2,3) 0 to 1.2 mm 0 to 0.05 in 0 to 1.6 mm 0 to 0.06 in 0 to 4 mm 0 to 0.09 in 0 to 8 mm 0 to 0.22 in 0 to 2 mm 0 to 0.08 in 0 to 3.2 mm 0 to 0.13 in 0 to 6.4 mm 0 to 0.25 in 0 to 12 mm 0 to 0.47 in Standard sensing object Iron sheet 8 8 t 1 mm 0.32 0.32 t 0.04 in Iron sheet 12 12 t 1 mm 0.47 0.47 t 0.04 in Iron sheet 18 18 t 1mm 0.71 0.71 t 0.04 in Iron sheet 30 30 t 1 mm 1.18 1.18 t 0.04 in Iron sheet 8 8 t 1 mm 0.32 0.32 t 0.04 in Iron sheet 12 12 t 1 mm 0.47 0.47 t 0.04 in Iron sheet 18 18 t 1 mm 0.71 0.71 t 0.04 in Iron sheet 30 30 t 1 mm 1.18 1.18 t 0.04 in Hysteresis (Note 2) Repeatability (Note 2) Supply voltage Current consumption (Note 4) Output Utilization category Short-circuit protection 15 % or less of operation distance (with standard sensing object) Along sensing axis: 5 % or less of operation distance 12 to 24 V DC ±10 % Ripple P-P 10 % or less 0.5 ma or less Non-contact DC 2-wire type Load current: 1.5 to 100 ma Residual voltage: 4.2 V or less (Note 5) DC-12 or DC-13 Incorporated Max. response frequency 1 khz 1 khz 1.2 khz 1.3 khz 1.1 khz 1.3 khz 1.5 khz 0.8 khz Operation indicator Pollution degree Yellow LED (lights up when the output is ON) 3 (Industrial environment) Environmental resistance Protection IP67 (IEC) IP69K (DIN), IP68 (IEC) (2 m cable length type only), IP67 (IEC) (M12 plug-in connector type only) Ambient temperature 25 to +70 C 13 to +158 F, Storage: 40 to +85 C 40 to +185 F Ambient humidity 50 % RH or less (at +70 C +158 F) EMC EN 60947-5-2 Voltage withstandability 500 V AC for one min. between all supply terminals connected together and enclosure Vibration resistance 10 to 55 Hz frequency, 0.5 mm 0.02 in amplitude in X, Y and Z directions for 1.5 hours each Shock resistance Sensing range variation (Note 2) Material Cable (except for M12 plug-in connector type) Cable extension 294 m/s 2 acceleration (30 G ) in X, Y and Z directions for three times each Within ±10 % fluctuation of sensing range at +23 C +73 F and rated voltage in the range of allowable temperature and supply voltage Enclosure: Brass (Nickel plated), Sensing part: PPS 0.44 mm 2 [0.15 mm 2 for GX-M(L)8 -U] 2-core cabtyre cable, 2 m 6.56 ft long Extension up to total 10 m 32.80 ft is possible with 0.34 mm 2, or more, cable. Net weight (Note 6) Accessories 2 m cable length type 40 g 70 g 90 g 150 g 40 g 70 g 90 g 150 g M12 pigtailed(-j type) / M12 plug-in connector type 20 g 20 g 45 g 110 g 20 g 20 g 45 g 110 g Nut: 2 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2) It is the value in state where the circumference of a detection side has a metal object. 3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. 4) It is the leakage current when the output is in the OFF state. 5) When the cable is extended, the residual voltage becomes larger. 6) The weight includes the weight of two nuts. 10

Cylindrical Inductive Proximity Sensor GX-M SERIES WIRING DIAGRAMS DC 3-wire type Wiring diagram NPN output type PNP output type (Brown) +V (Brown) +V Load (Black) Output + 12 to 24V DC ±10 % (Black) Output Load + 12 to 24V DC ±10 % (Blue) 0 V (Blue) 0 V Connector pin position M12 connector 4 3 1 2 Normally Open 1 : +V 2 : Not connected 3 : 0 V 4 : Output Normally Closed 1 : +V 2 : Output 3 : 0 V 4 : Not connected DC 2-wire type Wiring diagram (Brown) +V Load + 12 to 24V DC ±10 % (Blue) 0 V Load Connector pin position M12 connector 4 3 1 2 Normally Open (except for GX-M8 -U-J and GX-ML8 -U-J) 1 : Not connected 2 : Not connected 3 : +V 4 : 0 V Normally Open (GX-M8 -U-J and GX-ML8 -U-J only) 1 : +V 2 : Not connected 3 : Not connected 4 : 0 V Normally Closed 1 : +V 2 : 0 V 3 : Not connected 4 : Not connected 11

Cylindrical Inductive Proximity Sensor GX-M SERIES PRECAUTIONS FOR PROPER USE Mounting Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. The tightening torque should be under the value given below. Embedding of the sensor in metal Sensing range may decrease if the sensor is completely embedded in metal. Especially for the nonshielded type, keep the minimum distance specified in the right table. Sensor size M12 M18 M30 Note: With the non-shielded type, the sensing range may vary depending on the position of the nuts. B (mm in) 12 0.47 18 0.71 30 1.18 C (mm in) 12 0.47 18 0.71 30 1.18 Mutual interference When two or more sensors are installed in parallel or face to face, keep the minimum separation distance specified below to avoid mutual interference. Face to face mounting Parallel mounting Model No. GX-M Type DC 3-wire shielded type A (mm in) M8 M12 M18 M30 3 0.12 DC 3-wire non-shielded type - DC 2-wire standard type Sensor size DC 2-wire long range type 4.5 0.18 8 0.32 Tightening torque Sensor 4 0.16 21 0.83 6 0.23 12 0.47 Connector (Note) M8 5 N m 2 N m M12 6 N m 2 N m M18 15 N m 2 N m M30 40 N m 2 N m GX-M(L)8 -U-J M8 5 N m 1.5 N m Note: Connector is equipped with -Z type or -J type. Distance from surrounding metal As metal around the sensor may affect the sensing performance, pay attention to the following points. Influence of surrounding metal The surrounding metal will affect the sensing performance. Keep the minimum distance specified in the table below. 10 0.39 36 1.42 15 0.59 25 0.98 20 0.79 66 2.60 30 1.18 45 1.77 Type DC 3-wire shielded type DC 3-wire non-shielded type DC 2-wire standard type DC 2-wire long range type Wiring Make sure that the power supply is off while wiring. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. Ensure that an isolation transformer is utilized for the DC power supply. If an autotransformer is utilized, the main body or power supply may be damaged. If the used power supply generates a surge, connect a surge absorber to the power supply to absorb the surge. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Damage or burnout may result in case of short circuit of load or miswiring. Make a cable length as short as possible to lessen noise pickup. Others D (mm in) E (mm in) M8 M12 M18 M30 M8 M12 M18 M30 18 0.71-18 0.71 30 1.18 24 0.94 84 3.30 24 0.94 50 1.97 60 2.36 144 5.67 60 2.36 100 3.93 120 4.72 264 10.39 120 4.72 180 7.09 3 0.12 4 0.16 48 1.89 4 0.16 8 0.32 10 0.39 20 0.77 120 4.72 20 0.77 30 1.18 Our products have been developed / produced for industrial use only. Avoid using a product where there is excessive vapor, dust or corrosive gas, or in a place where it could be exposed directly to water or chemicals. Take care that the sensor does not come in direct contact with water, oil, grease or organic solvents, such as, thinner, etc. Do not use in an environment containing infammable or explosive gases. Never disassemble or modify the product. - 3 0.12 5 0.20 72 2.83 10 0.39 16 0.63 12

Cylindrical Inductive Proximity Sensor GX-M SERIES DIMENSIONS (Unit: mm in) DC 3-wire type LED Sensors 2 m cable length type (mm in) M12 plug-in connector type (mm in) Shielded type a b a b a b M8 GX-M8 33 1.30 25 0.98 45 1.77 24 0.94 M12 GX-M12 35 1.38 25 0.98 50 1.97 30 1.18 M18 GX-M18 39 1.54 28 1.10 50 1.97 28 1.10 M30 GX-M30 43 1.69 32 1.26 55 2.17 32 1.26 LED Sensors 2 m cable length type (mm in) M12 plug-in connector type (mm in) a b c Non-shielded type a b c a b c M12 GX-MK12 55 2.17 42 1.65 5 0.20 66 2.60 42 1.65 5 0.20 M18 GX-MK18 60 2.36 44 1.73 8 0.32 72 2.83 44 1.73 8 0.32 M30 GX-MK30 63 2.48 41 1.61 13 0.51 74 2.91 41 1.61 13 0.51 DC 2-wire type LED Sensors 2 m cable length type (mm in) M12 plug-in connector type (mm in) (M8 size: M12 pigtailed type) Standard type, Long range type a b a b a b M8 GX-M(L)8 -U (-J) 33 1.30 25 0.98 24 0.94 M12 GX-M(L)12 -U (-Z) 35 1.38 25 0.98 50 1.97 30 1.18 M18 GX-M(L)18 -U (-Z) 39 1.54 28 1.10 50 1.97 28 1.10 M30 GX-M(L)30 -U (-Z) 43 1.69 32 1.26 55 2.17 32 1.26 13

MEMO 14

Disclaimer The applications described in the catalog are all intended for examples only. The purchase of our products described in the catalog shall not be regarded as granting of a license to use our products in the described applications. We do NOT warrant that we have obtained some intellectual properties, such as patent rights, with respect to such applications, or that the described applications may not infringe any intellectual property rights, such as patent rights, of a third party. Please contact... Panasonic Electric Works SUNX Co., Ltd. 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Telephone: +81-568-33-7211 Facsimile: +81-568-33-2631 Global Sales & Marketing Division Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591 panasonic-electric-works.net/sunx All Rights Reserved Panasonic Electric Works SUNX Co., Ltd. 2011 No. CE-CYGX-10 November, 2011 Specifications are subject to change without notice. Printed in Japan