M40e and M160 Cooling System Installation Instructions

Similar documents
Replacing the T320 Cooling System Components. Replacing a T320 Fan Tray. Removing a T320 Front Fan Tray

Overview. Chassis Packaging

Installing the Switch

Cisco CRS Carrier Routing System 8-Slot Line Card Chassis Unpacking, Moving, and Securing

Installing the ONS M6 Shelf

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

Installing the Switch Chassis

Cisco ASR 1002 Router Overview and Installation

Cisco Network Convergence System 4000 Series Unpacking, Moving and Securing Guide

Agilent G1554A On-Column Capillary Inlet with EPC

5 Removal and replacement

Chapter 3. Installing Equipment

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

Upgrading the Boxer LAD blower module

Installing a PTV Inlet

Switch Installation. Preparing for Installation. Warnings CHAPTER

Note: If anything is damaged or missing, contact your customer representative immediately.

INSTALLATION MANUAL. Document revision: 1.3 Last revised: January 2, 2019

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

XLR-8 60 Extended Rack Autosampler

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

Desktop 5.5 Z Axis Retrofit

LVPS Replacement Instruction Sheet

Mounting an EX 8200 series Switch on a Rack or Cabinet Without Using a Mechanical Lift

1999 Volkswagen New Beetle GL

LED Downlight Ceiling Fixtures

Cisco CRS Carrier Routing System 16-Slot Line Card Chassis Enhanced Router Unpacking, Moving, and Securing Guide

Installing and Setting Up Your Ring Floodlight Cam

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

FlexJet Carriage Circuit Board (PCB) Replacement

Installation Instructions for John Deere cotton picker models: 9986 & 2-row and All-row systems included.

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

Cisco Beacon Point Module

Cisco Gigabit Switch Router Blower Module Replacement Instructions

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

NA-Tune Installation Procedure

Cisco Network Convergence System 6000 Series Routers Unpacking, Moving, and Securing Guide

GPS Steering System Installation Manual

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual

Routine Maintenance Procedures

Portable Pack USER MANUAL

Kelly KDHA High Voltage Series/PM Motor Controller User s Manual

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

Hardware Install Guide

Removable Applied Panel Mounting System

ELECRAFT KX3 Application Note

Kelly KDC Series/PM Motor Controller User s Manual

HP Modular Cooling System 200/100 Options Installation Guide

Installing the CO 2 Cryogenic Oven Cooling Kit

Install the Shelf and Common Control Cards

Installing a PTV Inlet

ST 3000 R300 Smart Meter & R300 Smart Meter with ZS Option Installation Instruction

Automated Liquid Handling Station

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

IBM CMM Quick Reference Guide

Lamp House with 2.5 kw lamp

Installation Guide Smart-UPS X 2000/2200/3000 XL Tower/Rack-Mount 4U

N/S= Not Shown Bold = Part available for purchase. Italic = Part not available for purchase, listed and shown for reference only.

HercuLine 2000 Series Gear Kit Replacement Instructions

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

HP Adjustable Depth Fixed Rail Kit Installation

ES50M-65N TROUBLESHOOTING AND REPAIR MANUAL ALL REPAIRS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Installing and Removing Power Supplies

E-Series and EF-Series Systems

PMC-MC-X2-Chassis PMC-MC-X4-Chassis

BMW 3Series (E46) Installation Guide StealthOne Version 1.6

Expansion Signal (XSIG) Card Installation Instructions

Version 1.4 Operating instructions Czech Republic

Service Bulletin Trucks Date Group No. Supp. Page

(31 ) ZEON CONTROL PACK RELOCATION KIT

Exhaust Heat Shield Instructions ND

Rocker Lever Assembly

Cellwatch Electrical Installation

Quick Setup Guide. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate.

Control Box Wiring For PRSstandard Tool

Written By: Tarun. This guide shows how to remove and replace the battery. AirPort Extreme A1521 Battery Replacement

Rack Installation Guide (Steelhead Series 3000, 5000, and 6000, and Interceptor Systems)

Fiber Connector Shelf (CCS)

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

Copyright 2004 Alcatel. All rights reserved.

RFI COLD AIR INTAKE INSTALLATION MANUAL. GM 6.0L Pickup and SUVs

Fiber Splice Panel Rack Mount User Manual

One-Gun Add-On Kit For Smart-Coat Controllers

TECHNICAL INFORMATION

Installation Guide. Purged Packed Inlet, Electronic Pneumatics Control on 6890 GC Accessory G1551A

NUMBER: rev S.M. REF.: Refer to 2.47 ENGINE: 50 DATE: June 2001

SNMP dedicated to ORVALDI Solar Infini

Installation Instructions for the PowerCommand 3100 FT-10 Network Genset Communications Module (GCM) Kit

Auto Sentry-eXP Maintenance. Revised 12/21/07

564 Shadowbox Face (w Screen) Instructions

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

8400 Series Fiber Distribution System

2O3D3-19A REVB MOUNTING

Automotive: Lightbars

Owner smanual. Banks Ram-Air Intake System Jeep 3.6L Wrangler JL. with Installation Instructions

Transcription:

M40e and M160 Cooling System Installation Instructions 6 August 2004 Part No: 530-005280-01 Revision 4 This document describes how to remove and replace the cooling system components on the Juniper Networks M40e and M160 Internet router. The components include the air filter, fan tray, and impeller assemblies. Contents Cooling System Description... 2 Tools and Parts Required... 5 Replacing the Air Filter... 5 Removing the Air Filter... 6 Installing the Air Filter... 7 Replacing the Fan Tray... 7 Removing the Fan Tray... 8 Installing the Fan Tray... 9 Replacing the Front Impeller Assembly...10 Removing the Front Impeller Assembly...10 Detaching the Craft Interface from the Front Impeller Assembly...11 Attaching the Craft Interface to the Front Impeller Assembly...12 Installing the Front Impeller Assembly...12 Replacing the Rear Upper Impeller Assembly...13 Removing the Rear Upper Impeller Assembly...13 Installing the Rear Upper Impeller Assembly...14 Replacing the Rear Lower Impeller Assembly...15 Removing the Rear Lower Impeller Assembly...15 Installing the Rear Lower Impeller...15 List of Technical Publications...16 How to Request Support...19 Revision History...19 1

Cooling System Description The cooling system has the following components: Air filter, air intake vent, and intake cover Provide an opening for room air to enter the router. The air intake vent and intake cover are located at the bottom of the chassis front, below the cable management system, as shown in Figure 2. Figure 1shows an M40e router; The location of all components is the same on an M160 router. The air filter is hot-removable and hot-insertable and covers the air intake vent, preventing dust and other particles from entering the cooling system. The nonremovable air intake cover is located behind the air filter and provideselectromagnetic compatibility (EMC) shielding. Front cooling subsystem Cools the Phyisical Interface Cards (PICs), Flexible PIC Concentrators (FPCs) and midplane. This subsystem includes a fan tray located behind the cable management system and a large, central impeller behind the craft interface, shown in Figure 1. Both components are hot-removable and hot-insertable. Rear cooling subsystem Cools the Switching and Forwarding Modules (SFMs), host module, Packet Forwarding Engine Clock Generators (PCGs), and power supplies. This system includes an impeller located at the upper right of the chassis rear and another at the lower left, as shown in Figure 2. The two impellers are both hot-removable and hot-insertable, but not interchangeable. 2 Cooling System Description

R M40e and M160 Cooling System Component Installation Instructions Figure 1: Front of Chassis Center rack-mounting ear Front support posts Craft interface FPCs CIP ESD point Cable management system Air filter 1900 Cooling System Description 3

OFF M40e and M160 Cooling System Component Installation Instructions Figure 2: Rear of Chassis with Component Cover in Place Upper impeller Component cover ESD point PCG 0 PCG 1 PCG 0 PCG 1 Lower impeller Grounding points Circuit breaker box DC power supplies DC-powered router AC power supplies AC-powered router OFF 1902 The Miscellaneous Control Subsystem (MCS) constantly monitors the temperature of the router s components. When the temperatures are below the acceptable maximum, the fans and impellers function at less than full speed. If the MCS detects that the temperature of a component has exceeded the acceptable maximum for example, because an impeller is removed it automatically increases the speed of the remaining impellers and fans to reduce the temperature. The fans and impellers can function at the higher speed for one half hour. Figure 3 shows the airflow through the impellers and fan tray. 4 Cooling System Description

Figure 3: Airflow Through the Chassis Front view Impeller Side view Impeller Top view Front Rear Rear Impeller (upper rear) Card cage Air intake cover Fan tray Impeller (upper front) 1170 Front Tools and Parts Required To remove and install cooling system components, you need the following tools and parts: Phillips (+) screwdrivers, numbers 1 and 2 Flat-blade screwdriver, approximately 1/4 in. (6 mm) Electrostatic discharge (ESD) grounding wrist strap Electrostatic bag or antistatic mat for each component removed Replacing the Air Filter The air filter is located at the bottom of the chassis front (see Figure 1.Check the air filter regularly for dust and debris. Replace it as needed. The air filter is hot-removable and hot-insertable, but take note of the following caution. CAUTION: Do not operate the router for more than a few minutes when the air filter has been removed. The fans and impellers are powerful enough to draw in foreign material, such as bits of wire, through the unfiltered air intake, which could damage router components. Replacing the Air Filter 5

To clean and replace the air filter, perform the following procedures: Removing the Air Filter on page 6 Installing the Air Filter on page 7 Removing the Air Filter To remove the air filter, follow this procedure: 1. Attach an ESD strap to your bare wrist and connect the strap to one of the 2. Loosen the thumbscrews at the corners of the air filter cover (), using a Phillips screwdriver if necessary. 3. Grasp the edges of the air filter cover and pull it and the air filter away from the frontofthechassisasshownin. 4. Pull the air filter out of the air filter cover, as shown in. 5. Inspect the filter for dust, dirt, and holes. Replace the filter if needed as described in Installing the Air Filter on page 7. Figure 4: Removing the Air Filter Air filter cover 1217 Air filter 1217 Air intake cover Thumbscrew 6 Removing the Air Filter

Figure 5: Removing the Filter from the Air Filter Cover Air filter Air filter cover 1235 Installing the Air Filter To install the air filter, follow this procedure: 1. Attach an ESD strap to your bare wrist and connect the strap to one of the 2. Gently press the replacement air filter into the air filter cover. 3. Grasp the sides of the air filter cover and push it and the filter firmly into place over the air intake vent, as shown in Figure 6. 4. Tighten the thumbscrews at the corners of the air filter cover. Figure 6: Installing the Air Filter Air filter cover 1218 Air filter Replacing the Fan Tray The fan tray is located behind the cable management system on the front of the chassis, as shown in Figure 1, and weighs approximately 13 lbs (5.9 kg). It houses Replacing the Fan Tray 7

four fans that blow room air onto the FPCs and midplane to cool them. The fan tray is hot-insertable and hot-removable. To replace it, perform the following procedures: Removing the Fan Tray on page 8 Installing the Fan Tray on page 9 Removing the Fan Tray To remove the fan tray, follow this procedure: 1. Safely stow any PIC cables out of the way as follows: a. Unwrap the cables from the spools on the cable management system. b. Remove the cables from the tray. c. Arrange the cables so that they do not block the front of the cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from their connections. CAUTION: Never let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point. 2. Attach an ESD strap to your bare wrist and connect the strap to one of the 3. Loosen the thumbscrews at the left and right sides of the cable management system, using a Phillips screwdriver if necessary. 4. Grasp the sides of the fan tray and pull firmly to slide it halfway out of the chassis (see Figure 7). CAUTION: If the fans are still spinning, do not touch them with your fingers or any tool as you slide the fan tray out. To avoid injury, wait until the fans stop spinning before removing the fan tray. 5. When the fans are no longer spinning, slide the fan tray completely out of the chassis. 8 Removing the Fan Tray

Figure 7: Removing the Fan Tray 1936 Installing the Fan Tray To install the fan tray, follow this procedure (see Figure 8): 1. Attach an ESD strap to your bare wrist and connect the strap to one of the 2. Grasp the sides of the replacement fan tray and align the rear of the tray with the guides inside the chassis. 3. Slidethefantrayallthewayintothechassis,takingcarenottocatchorpinch any dangling PIC cables with the edges of the tray. The fans start spinning as soon as the fan tray contacts the midplane. 4. Tighten the thumbscrews at the left and right ends of the cable management system. 5. Rearrange the PIC cables in the cable management system. For more information about proper cable arrangement, see the M40e Internet Router Hardware Guide or M160 Internet Router Hardware Guide. Installing the Fan Tray 9

Figure 8: Installing the Fan Tray 1937 Replacing the Front Impeller Assembly The front impeller assembly is located at the front of the chassis above the FPC card cage, as shown in Figure 1. The assembly weighs approximately 14.5 lb (6.6 kg), and is hot-removable and hot-insertable. The craft interface is attached to the front of the front impeller assembly. If the replacement front impeller assembly you are installing does not have a replacement craft interface already installed on it, you must transfer the craft interface from the removed assembly to the replacement assembly. Perform the following procedures: Removing the Front Impeller Assembly on page 10 Detaching the Craft Interface from the Front Impeller Assembly on page 11 Attaching the Craft Interface to the Front Impeller Assembly on page 12 Installing the Front Impeller Assembly on page 12 If the replacement front impeller assembly has a craft interface installed on it, perform only the procedures Removing the Front Impeller Assembly on page 10 and Installing the Front Impeller Assembly on page 12. Removing the Front Impeller Assembly To remove the front impeller assembly, follow this procedure: (See Figure 9, which shows the front impeller on an M40e router.) 1. Place an electrostatic bag on antistatic mat on a flat, stable surface to receive the assembly. 2. Attach an ESD strap to your bare wrist and connect the strap to one of the 10 Removing the Front Impeller Assembly

R M40e and M160 Cooling System Component Installation Instructions 3. Using a Phillips screwdriver, loosen the captive screws at the corners of the craft interface. 4. Insert a flat-blade screwdriver into the gap around the craft interface and gently pry the impeller assembly forward until you can grasp the sides of the assembly and slide it halfway out of the chassis. CAUTION: If the impeller is still spinning, do not touch it with your fingers or any tool as you slide the impeller assembly out. To avoid injury, wait until the impeller stops spinning before removing the assembly. 5. Place one hand under the assembly to support it. When the impeller is no longer spinning, slide the assembly completely out of the chassis and place it on the antistatic mat or in the electrostatic bag prepared in Step 1. 6. If you are replacing the front impeller assembly and the replacement assembly hasacraftinterfacepanelinstalledonit,proceedto InstallingtheFront Impeller Assembly on page 12. Otherwise, proceed to Detaching the Craft Interface from the Front Impeller Assembly on page 11. Figure 9: Removing the Front Impeller Assembly Captive screw 1916 Detaching the Craft Interface from the Front Impeller Assembly If you are replacing the front impeller assembly and the replacement assembly does not have a craft interface panel installed on the front, you must transfer the craft interface from the removed assembly to the replacement assembly. To detach the craft interface from the removed impeller assembly, follow this procedure: 1. If you are not immediately transferring the craft interface to a replacement impeller assembly, prepare an electrostatic bag or antistatic mat to receive it. 2. Attach an ESD strap to your bare wrist and connect the strap to one of the Detaching the Craft Interface from the Front Impeller Assembly 11

3. Place the replacement front impeller assembly on an antistatic mat on a flat, stable surface, top side down, so that the lettering on the craft interface is upside down. 4. Using a Phillips screwdriver, loosen and remove the eight flat-head screws that secure the top and the bottom of the craft interface housing to the impeller assembly. Save the screws for reinstallation. 5. Using a Phillips screwdriver, loosen and remove the round-head screws from the rear of the craft interface. Two screws are located on each side, near the holes for the captive screws that secure the impeller assembly to the chassis. Save the screws for reinstallation. 6. Grasp the sides of the craft interface and pull it straight off the front of the impeller assembly. 7. If not immediately transferring it to a replacement impeller assembly, place it in the electrostatic bag or on the antistatic mat prepared in Step 1. Attaching the Craft Interface to the Front Impeller Assembly To attach the craft interface to the front impeller assembly, follow this procedure: 1. Attach an ESD strap to your bare wrist and connect the strap to one of the 2. Place the replacement impeller assembly top side up on an antistatic mat on a flat, stable surface. 3. Orientthecraftinterfacesothattheletteringisrightsideup. Makesurethe connector on the rear of the interface is on the left end so that it will line up with the connector on the chassis. 4. When the connectors are aligned, push the craft interface straight back onto the face of the impeller assembly. 5. Using a Phillips screwdriver, install two round-head screws into the holes on each side of the craft interface. The holes are located near the holes for the captive screws that secure the impeller assembly to the chassis. 6. Using a Phillips screwdriver, install flat-head screws into the four holes along the top of the craft interface housing. 7. Carefully turn the impeller assembly over (top side down) and install flat-head screws into the four holes along the bottom of the craft interface housing. Installing the Front Impeller Assembly To install the front impeller assembly onto the chassis, follow this procedure: (See Figure 10, which shows an M40e router.) 1. Attach an ESD strap to your bare wrist and connect the strap to one of the 12 Installing the Front Impeller Assembly

R M40e and M160 Cooling System Component Installation Instructions 2. Grasp the sides of the replacement impeller assembly and align the rear of the assembly with the guides inside the chassis. 3. Using a Phillips screwdriver, tighten the captive screws at the corners of the craft interface. Figure 10: Installing the Front Impeller Assembly Captive screw 1917 Replacing the Rear Upper Impeller Assembly The rear upper impeller assembly is located at the upper left on the rear of the chassis, as shown in Figure 2. It weighs about 4 lb (1.8 kg). The assembly is hot-removable and hot-insertable. To replace it, perform the following procedures. Removing the Rear Upper Impeller Assembly on page 13 Installing the Rear Upper Impeller Assembly on page 14 Removing the Rear Upper Impeller Assembly To remove the rear upper impeller, follow this procedure (see Figure 11): 1. Attach an ESD strap to your bare wrist and connect the strap to one of the 2. Loosenthethumbscrewsatthecornersoftheimpeller,usingaPhillips screwdriver if necessary. 3. Grasp the screws at opposite corners of the impeller cover and slide the assembly halfway out of the chassis. CAUTION: If the impeller is still spinning, do not touch it with your fingers or any tool as you slide the impeller assembly out. To avoid injury, wait until the impeller stops spinning before removing the assembly. Removing the Rear Upper Impeller Assembly 13

4. When the impeller is no longer spinning, slide the assembly completely outofthechassis. Figure 11: Removing the Rear Upper Impeller Assembly 1933 Installing the Rear Upper Impeller Assembly To install the rear upper impeller assembly, follow this procedure (see Figure 12): 1. Attach an ESD strap to your bare wrist and connect the strap to one of the 2. Slide the replacement assembly all the way into the chassis. 3. Tighten the thumbscrews at the corners of the impeller cover. Figure 12: Installing the Rear Upper Impeller Assembly 1934 14 Installing the Rear Upper Impeller Assembly

Replacing the Rear Lower Impeller Assembly The rear lower impeller assembly is located at the lower left of the rear on the chassis, above the left power supply, as shown in Figure 2. It weighs about 4 lb (1.8k kg). The assembly is hot-removable and hot-insertable. following procedures: To replace it, perform the Removing the Rear Lower Impeller Assembly on page 15 Installing the Rear Lower Impeller on page 15 Removing the Rear Lower Impeller Assembly Toremovetherearlowerimpellerassembly,followthisprocedure(seeFigure13): 1. Attach an ESD strap to your bare wrist and connect the strap to one of the 2. Loosenthethumbscrewsatthecornersoftheimpeller,usingaPhillips screwdriver if necessary. 3. Grasp the sides of the impeller assembly and slide it halfway out of the chassis. CAUTION: If the impeller is still spinning do not put your fingers or any tool into the impeller assembly as you slide it out. To avoid injury, wait until the impeller stopsspinningbeforeremovingit. 4. When the impeller is no longer spinning, slide the assembly completely outofthechassis. Figure 13: Removing the Rear Lower Impeller Assembly 1914 Installing the Rear Lower Impeller To install the rear lower impeller, follow this procedure: Installing the Rear Lower Impeller 15

1. Attach an ESD strap to your bare wrist and connect the strap to one of the grounding points on the chassis. 2. Orient the replacement impeller so that the label is on the top, as shown in Figure 14. 3. Align the rails on the upper edges of the impeller assembly with the guides inside the chassis. 4. Pushtheimpellerassemblyupandtotherighttostartitintothechassis, then slide it all the way in. 5. Tighten the thumbscrews at the corners of the impeller cover. Figure 14: Installing Rear Lower Impeller Label Guides Rails 1915 List of Technical Publications Table 1 lists the software and hardware books for Juniper Networks M-series and T-series routers and describes the contents of each book. Table 1: Juniper Networks Technical Documentation Book Description JUNOS Internet Software for M-series, T-series, and J-series Routing Platforms Configuration Guides 16 List of Technical Publications

Book Feature Guide System Basics Network Interfaces and Class of Service MPLS Applications Multicast Protocols Network Management Policy Framework Routing Protocols Services Interfaces VPNs JUNOS Software References Network and Services Interfaces Command Reference Protocols, Class of Service, and System Basics Command Reference Description Provides a detailed explanation and configuration examples for several of the most complex features in the JUNOS software. Provides an overview of the JUNOS software and describes how to install and upgrade the software. This manual also describes how to configure system management functions and how to configure the chassis, including user accounts, passwords, and redundancy. Provides an overview of the network interface and class-of-service functions of the JUNOS software and describes how to configure the network interfaces on the router. Provides an overview of traffic engineering concepts and describes how to configure traffic engineering protocols. Provides an overview of multicast concepts and describes how to configure multicast routing protocols. Provides an overview of network management concepts and describes how to configure various network management features, such as SNMP, accounting options, and cflowd. Provides an overview of policy concepts and describes how to configure routing policy, firewall filters, and forwarding options. Provides an overview of routing concepts and describes how to configure routing, routing instances, and unicast routing protocols. Provides an overview of the services interfaces functions of the JUNOS software and describes how to configure the services interfaces on the router. Provides an overview and describes how to configure Layer 2 and Layer 3 virtual private networks (VPNs), virtual private LAN service (VPLS), and Layer 2 circuits. Provides configuration examples. Describes the JUNOS Internet software operational mode commands you use to monitor and troubleshoot network and services interfaces on Juniper Networks M-series and T-series routers. Describes the JUNOS Internet software operational mode commands you use to monitor and troubleshoot most aspects of Juniper Networks M-series and T-series routers. List of Technical Publications 17

Book System Log Messages Reference JUNOScript API Documentation JUNOScript API Guide JUNOScript API Configuration Reference JUNOScript API Operational Reference Description Describes how to access and interpret system log messages generated by JUNOS software modules and provides a reference page for each message. Describes how to use the JUNOScript application programming interface (API) to monitor and configure Juniper Networks routers. Provides reference pages for the configuration tags in the JUNOScript API. Provides reference pages for the operational tags in the JUNOScript API. JUNOS Internet Software Comprehensive Index and Glossary Comprehensive Index and Glossary Hardware Documentation Hardware Guide PIC Guide JUNOScope Software Documentation JUNOScope Software User Guide Release Notes JUNOS Internet Software Release Notes Hardware Release Notes JUNOScope Software Release Notes Provides a complete index of all JUNOS Internet software books and the JUNOScript API Guide. Also provides a comprehensive glossary. Describes how to install, maintain, and troubleshoot routers and router components. Each platform has its own hardware guide. Describes the router Physical Interface Cards (PICs). Each router platform has its own PIC guide. Describes the JUNOScope software graphical user interface (GUI), how to install and administer the software, and how to use the software to manage router configuration files and monitor router operations. Provide a summary of new features for a particular software release. Software release notes also contain corrections and updates to published JUNOS and JUNOScript manuals, provide information that might have been omitted from the manuals, and describe upgrade and downgrade procedures. Describe the available documentation for the router platform and summarize known problems with the hardware and accompanying software. Each platform has its own release notes. Contain corrections and updates to the published JUNOScope manual, provide information that might have been omitted from the manual, and describe upgrade and downgrade procedures. 18 List of Technical Publications

How to Request Support Revision History For technical support, open a support case using the Case Manager link at http://www.juniper.net/support/ or call 1-888-314-JTAC (within the United States) or 1-408-745-9500 (outside the United States). For documentation issues, fill out the bug report form located at http://www.juniper.net/techpubs/docbug/docbugreport.html 04 August 2004 Second Revision. Removed filter cleaning procedure. 15 February 2004 First Revision. Copyright 2004, Juniper Networks, Inc. All rights reserved.juniper Networks, the Juniper Networks logo, NetScreen, NetScreen Technologies, the NetScreen logo, NetScreen-Global Pro, ScreenOS, and GigaScreen are registered trademarks of Juniper Networks, Inc. in the United States and other countries. The following are trademarks of Juniper Networks, Inc.: ERX, ESP, E-series, Instant Virtual Extranet, Internet Processor, J2300, J4300, J6300, J-Protect,J-series,J-Web,JUNOS,JUNOScope,JUNOScript,JUNOSe,M5,M7i,M10,M10i,M20,M40,M40e,M160,M320,M-series,MMD,NetScreen-5GT, NetScreen-5XP, NetScreen-5XT, NetScreen-25, NetScreen-50, NetScreen-204, NetScreen-208, NetScreen-500, NetScreen-5200, NetScreen-5400, NetScreen-IDP 10, NetScreen-IDP 100, NetScreen-IDP 500, NetScreen-Remote Security Client, NetScreen-Remote VPN Client, NetScreen-SA 1000 Series, NetScreen-SA 3000 Series, NetScreen-SA 5000 Series, NetScreen-SA Central Manager, NetScreen Secure Access, NetScreen-SM 3000, NetScreen-Security Manager, NMC-RX, SDX, Stateful Signature, T320, T640, and T-series. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners. All specifications are subject to change without notice. Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice. How to Request Support 19