Addendum to the Catalog Diagnostic unit /DUE for function and wear monitoring of brakes BE.., BF.., BT..

Similar documents
7 Brake and backstop. 7.1 BE.. brake from SEW EURODRIVE. BE.. brake from SEW EURODRIVE

Electromagnetic Flow Monitor magphant

Displacement Sensor. Model 8739, 8740, 8741

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

JUMO MIDAS S05 Pressure transmitter Type

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

S-SERIES DISPLACEMENT TRANSDUCERS

HIGH POWER SOLENOID DRIVER 1

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Continuous level sensor NSK

Description CMP servomotors are delivered with 2-pole resolvers as standard. Further information on other resolvers is available on request.

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

Pilot-Operated Proportional DC Valve Series D*1FH

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

6 Project Planning for Components on the Input Side

Electromagnetic Flow Monitor magphant

Hall sensors. Overview Page 28 Functional principle and installation Page 29 Cylindrical designs Page 31. Hall sensors.

Flow measurement FlexFlow PF20H Hygienic flow sensor

! CAUTION! Damages on the machine possible.

Inductive conductivity meter

Continuous level sensor NSK

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

Temperature Sensor without thread

The controllableollable Torque Limiting Clutch for

Thermal flow sensor TFS-35

SIRIUS 3RU2 Thermal Overload Relays

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Angle sensor AN2 series 30

JUMO MIDAS Pressure transmitter

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

OPTISWITCH 6500 C Technical Datasheet

BODAS Pressure sensor PR3 series 10

Thermal flow sensor TFS-35

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

J TS 7090 Thyristor power switch

INFORMATION. Hybrid cables. Description

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Standard cylinders DDPC, with measured-value transducer DADE

Inductive conductivity meter

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Pressure transmitter for elevated media temperatures

PPT 802, Proximity Probe Transducer System

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Electronic pressure switch with two switching outputs

Pressure Transmitter JUMO dtrans p30 Type

OPTISWITCH 6500 C Technical Datasheet

Automatic mould level control in Bokaro Steel Plant

Figure 1: WPR2 Dimensions and Hardware

Operating instructions Binary level sensor. LI214x /00 04/2016

Level Sensor with G1/2" Thread Hygienic

Electronic Limit Switch Type

Level Sensor with M12 Thread Hygienic

The High Power Stack Horizon

AXS 215S: Continuous actuator for unit valves, with stroke indicator

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

A Practical Guide to Free Energy Devices

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

M1..N, X and MD series Horizontal Helical and Bevel-Helical Gear Units

optical sensors through-beam, retro-reflective, dif. reflection sensors 2300 visible red light robust metal housing

DATAFLEX 110/... Torque Measuring Shaft Operating/Assembly instructions DATAFLEX. Torque measuring shaft type 110/

Solenoid coil Types BB, BE, BF, BG, and BN

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

Wireless Charger. Inductive charging system for AGVs

Inductive Proximity Sensor

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Latest News ECDriveS 24 V drive system for roller conveyors

Chip beads. For power line Large current/low DC resistance type. MPZ-H series. MPZ1005-H type. * Dimensions code JIS[EIA]

BATCHFLUX 5500 C Technical Datasheet

2-position electric actuators with Ball valves VBZ ½...11/4

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

Series 3730 Electropneumatic Positioner Type

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Servotronic Digital 615 Series

DATAFLEX 42/1000 Torque Measuring Shaft Operating/Assembly instructions DATAFLEX

JUMO ecotrans Lf 01/02

Differential Pressure Sensors

SITRANS P measuring instruments for pressure

3RG4 BERO Inductive Proximity Switches

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Conductivity Measuring Cells ConduMax W CLS 19

Synchronous motors. Main spindle motors for SINAMICS S120 1FE1 standard type built-in motors Water cooling. 6/86 Siemens NC /2008

Temposonics. M-Series Analog. Magnetostrictive Position Sensors. Temposonics MH Measuring length mm SENSORS

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Electronic Pressure Switch EDS 3000

Orbipore CPS91 and CPS91D

* _1217* Drive Technology \ Drive Automation \ System Integration \ Services. Catalog. AC Motors DRN80 315

Compact Proportional Solenoid Valve

Signet Pressure Transmitter

Flow - magnetic inductive - probe form

Detector (for water measurement applications)

* _1015* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Drive Unit MGF..-DSM

Transcription:

Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Catalog Diagnostic unit /DUE for function and wear monitoring of brakes BE.., BF.., BT.. Date 8/2015 22501061/EN

Table of Contents Table of Contents 1. Description... 3 1.1. Evaluation unit... 3 1.2. Sensors... 3 2. Features... 4 2.1. Functional description... 4 2.2. Meaning of the LEDs... 5 2.3. Designations of the terminals... 6 2.4. Output signals for function and wear monitoring... 7 3. Motor structure with diagnostic unit /DUE... 8 3.1. DRN.. with BE..... 8 3.2. DRN.. with BF../BT..... 8 4. Technical data... 9 5. Dimensions... 10 5.1. DUE-1K-00... 10 5.2. DUE-2K-00... 10 6. Connection of the diagnostic unit... 11 6.1. Recommended connection technology for the motor connection... 11 6.2. Block diagram of the diagnostic unit /DUE for type BE.. brakes... 12 6.3. Block diagram of the diagnostic unit /DUE for type BF../BT.. brakes... 13 6.4. Connecting the sensors... 13 7. Setting and installing the evaluation unit... 14 8. Notes... 15 2

Description 1. Description The diagnostic unit /DUE (Diagnostic Unit Eddy Current) is an option for DRN.. motors with brake. It is designed for industrial use and is used for monitoring the maximum working air gaps of SEW brakes of type BE.. and double brakes of type BF../BT.. from SEW-EURODRIVE. The diagnostic unit /DUE consists of: Evaluation unit in the motor terminal box that is supplied via a 24 V DC voltage. 1 sensor, installed in the magnet body of brakes BE1 to BE122 2 sensors, installed in the magnet bodies of double brakes BF/BT11 to BF/BT30 1.1. Evaluation unit The evaluation unit is available in 2 versions: DUE-1K: Single-channel version for BE.. brakes (see figure on left) DUE-2K: Two-channel version for BF../BT.. brakes (see figure on right) 1.2. Sensors DUE-d6: DUE-d8: Diameter 6 mm for BE1 - BE5 (see figure on left) Diameter 8 mm for BE11 - BE122, BF/BT11-BF/BT30 (see figure on right) This document primarily describes the diagnostic unit /DUE for use with the BE.. brake. Additional information has been included in order to also provide an overview of use with the BF../BT.. double brake. 3

Features 2. Features The most important characteristics are listed below: 2 digital output signals (DC 24 V): 1 digital output with NO contact function as function monitor for the brake: Detection of the correct brake function (brake released/engaged) 1 digital output with NC contact function as wear monitor for the brake: Detection of the maximum brake wear limit (working air gap OK/too big) A current signal (4 max. 20 ma) proportional to the air gap. The sensor is integrated in the coil body. LEDs in the evaluation unit signal the status of the digital outputs. The evaluation unit (electronics) is always installed in the terminal box, and takes on the degree of protection of the overall drive. The degree of protection of the sensor is IP66, meaning that IP66 can be offered as the overall degree of protection for the drive. Detection of brake pad wear and the function of the brake is contactless and hence wearfree. The diagnostic unit /DUE is supplied in the brake motor fully assembled and calibrated. DIP switches for setting the sensor size and the maximum permissible wear limit, for optimum adaptation to the application in conjunction with condition monitoring. In the event of a change of pad carrier or air gap adjustment in the event of wear, no recalibration of the eddy current sensor is necessary, since the installation environment of the sensor does not change. Subsequent shortening of the connection cable between the evaluation electronics and the sensor and replacement of the sensor, the evaluation electronics, the magnet body or the pressure plate always requires recalibration of the evaluation electronics. Connection variants Directly via cage clamp terminal Connection via M12 connector (4-pin or 8-pin) is in preparation. The diagnostic unit can be retrofitted (in preparation, please contact SEW-EURODRIVE). 2.1. Functional description The diagnostic unit /DUE (Diagnostic Unit Eddy Current) is a contactless measuring system for function and wear monitoring of the brake and continuous measurement of the current working air gap. It is a contactless measuring system, based on the eddy current principle. A highfrequency alternating current flows through the sensors. The electromagnetic field induces eddy currents in the pressure plate that change the alternating current resistance of the sensor. The evaluation unit converts this change in impedance into an electrical signal (4 20 ma) that is proportional to the working air gap of the brake. The function of the brakes is monitored via digital signals (NO contact). The reaching of the wear limit is signaled by digital outputs (NC contact). Furthermore, current outputs allow the wear of the brake to be continuously monitored. In addition to the outputs, LEDs at the evaluation unit indicate the function and wear of each partial brake. 4

Features 1 or 2 red LEDs indicate the state of wear of the respective partial brake 1 or 2 green LEDs indicate the function of the respective partial brake Further diagnosis can also be carried out using the various light codes of the LEDs. If the brake is ordered in combination with the diagnostic unit /DUE, the function and wear monitoring function is already installed, calibrated and set to the permitted wear limit for the brake in the factory. 2.2. Meaning of the LEDs LEDs Designation Description Green [6] * FCT2 Partial brake II is open. Electromagnet is active. Pressure plate is in contact with magnet body. Red [6] * WEAR2 The current working air gap of partial brake II has reached or exceeded the preset maximum working air gap. Green [7] FCT1 Partial brake I is open. Electromagnet is active. Pressure plate is in contact with magnet body. Red [7] WEAR1 The current working air gap of partial brake I has reached or exceeded the preset maximum working air gap. * only with DUE-2K-00 in conjunction with double brake BF../BT.. 5

Features 2.3. Designations of the terminals Connection of the sensors [2] Terminal Designation Description Color coding 1s * A2 Sensor 2 connection 1 Brown (BN) 2s * GND2 Sensor 2 shield Black (BK) 3s * B2 Sensor 2 connection 2 White (WH) 4s A1 Sensor 1 connection 1 Brown (BN) 5s GND1 Sensor 1 shield Black (BK) 6s B1 Sensor 1 connection 2 White (WH) * only with DUE-2K-00 in conjunction with double brake BF../BT.. Connection at customer end [3] Terminal Designation Description 1k * OUT2 Analog output, partial brake II working air gap (4 20 ma) 2k * FCT2 Digital output, partial brake II function (NO contact) 3k * WEAR2 Digital output, partial brake II wear (NC contact) 4k OUT1 Analog output, partial brake I working air gap (4 20 ma) 5k FCT1 Digital output, partial brake I function (NO contact) 6k WEAR1 Digital output, partial brake I wear (NC contact) 7k ZERO Input, zero value calibration 8k INF Input, infinite value calibration 9k AGND Signal ground AGND 10k GND Ground potential GND 11k 24 V DC 24 V DC supply * only with DUE-2K-00 in conjunction with double brake BF../BT.. 6

Features 2.4. Output signals for function and wear monitoring The figure shows the generation of the switching states on the example of the single-channel version of the diagnostic unit /DUE, depending on the brake size or sensor and the amperage as a function of the air gap. Sensor 6 mm IOut [ma] Sensor 8 mm IOut [ma] 20 13,6 20 13,6 10 10 4 0 x [5] 0,9 [4] [3] 1,5 x [mm] 4 0 x [5] 1,2 [4] [3] 2,0 x [mm] U [V] 24 [1] U [V] 24 [1] FCT 0 U [V] 24 [2] FCT 0 U [V] 24 [2] 0 WEAR 0 WEAR [1] FCT: Digital output function (DC 24 V, DIN EN 61131-2) [2] WEAR: Digital output wear (DC 24 V, DIN EN 61131-2) [3] Measuring range of sensor [4] Max. working air gap of brake [5] Currently measured working air gap (exemplary) 7

Motor structure with diagnostic unit /DUE 3. Motor structure with diagnostic unit /DUE 3.1. DRN.. with BE.. [54] Magnet body [1151] Sensor [112] Terminal box lower part [1727] Grommet [378] Screw plug [1757] Evaluation unit [379] Cable gland 3.2. DRN.. with BF../BT.. [112] Terminal box lower part [1152] Distance sensor 1 [379] Screw plug [1153] Spring [698] Complete plug connector [1154] Flat head screw [1119] Screw fitting [1757] Evaluation unit [1151] Distance sensor 2 [1758] Retaining screw 8

Technical data 4. Technical data Evaluation unit DUE-1K-00 for brake BE.. DUE-2K-00 for brake BF../BT.. Part number 21195609 21195536 Signal outputs (2 channels) BE.. brake Out1: 4 20 ma FCT1: DC 24 V (150 ma) WEAR1: DC 24 V (150 ma) Partial brake 1 for brake BF../BT.. Out1: 4 20 ma FCT1: DC 24 V (150 ma) WEAR1: DC 24 V (150 ma) Partial brake 2 for brake BF../BT.. Out2: 4 20 ma FCT2: DC 24 V (150 ma) WEAR2: DC 24 V (150 ma) Current consumption Max. ma 190 360 Min. ma 40 80 Supply voltage DC 24 V (± 15 %) Electromagnetic compatibility DIN EN 61800-3 Operating temperature range of evaluation unit Humidity Degree of protection -40 to +105 C 90% RH IP20 (in closed terminal box max. IP66) sensors DUE-d6-00 Ø 6 mm DUE-d8-00 Ø 8 mm Measuring range (MB) in mm max. 1.5 2.0 Degree of protection IP66 IP66 Operating temperature range of sensor and cable -50 to +150 C -50 to +150 C Max. ambient temperature of brake motor with diagnostic unit /DUE The standard temperature range is -20 C to +40 C. Temperature ranges up to +60 C are also possible; this is dependent on the thermal load and the use of other options that have an influence on the thermal behavior of the motor. Temperature ranges down to max. -40 C are also possible. 9

Dimensions 5. Dimensions All dimensions are in mm. 5.1. DUE-1K-00 5.2. DUE-2K-00 10

Connection of the diagnostic unit 6. Connection of the diagnostic unit The function and wear monitoring is connected according to the following wiring diagrams in the wiring diagram shown in chapters 6.2 and 6.3. The maximum permitted cable cross-section at terminals "[k]" is 1.5 mm² with conductor end sleeve without plastic collar, 0.75 mm² with plastic collar. The recommended cable cross-section at terminals "[k]" is 0.5 mm² with conductor end sleeve with plastic collar. INFORMATION SEW-EURODRIVE recommends the use of a shielded line when wiring. In environments that are particularly interference-intensive, SEW-EURODRIVE recommends the use of a shielded cable to the evaluation unit for monitoring the analog signals. Connect one end of the shield to GND. If the diagnostic unit /DUE was ordered with the brake, the function and wear monitoring is preinstalled and calibrated in the factory. The customer connection still needs to be made, see wiring diagram. Information about operating instructions "AC motors - DR..71 315, DRN80 315": If the diagnostic unit /DUE is retrofitted, observe chapter "Retrofitting the diagnostic unit /DUE for function and wear monitoring". The switching point of the wear monitoring is preset to the maximum permitted value for the brake in the factory. According to the "code table", a reduced value can also be set. The status of the evaluation unit can be found in chapter "Status message of the evaluation unit". 6.1. Recommended connection technology for the motor connection Observation of the following points ensures the functionality of the diagnostic unit: Assembly with connection unit: Use of a standard cable and feeding through into the terminal box via a cable gland. Important characteristics of the bulk cable to be used: Total shielding (outer shield) of the cable 100 m maximum length for fixed installation 50 m maximum length for cable carrier installation 11

Connection of the diagnostic unit Use of lines with 3 cores: Function or wear; [FCT/WEAR, +24 V, GND] or 4 cores: Function and wear [FCT, WEAR, +24 V, GND] or analog air gap signal [OUT, +24 V, AGND, GND] or 6 cores: Function and wear and analog air gap signal [OUT, FCT, WEAR, +24 V, AGND, GND]); 11 cores: all signals with calibration In order to make calibration via a PLC possible, inputs INF and ZERO and the AGND signal must be led to the outside. The inputs must be routed to AGND during normal operation. GND and AGND have the same potential. If this potential is not dealt with separately in the application, AGND is not necessary. With double brake BF../BT.., the FCT, OUT and WEAR signals are doubled. INFORMATION We recommend routing the power cable of the drive and the cable of the diagnostic unit separately.. 6.2. Block diagram of the diagnostic unit /DUE for type BE.. brakes [1] Evaluation unit [2] Sensor 12

Connection of the diagnostic unit 6.3. Block diagram of the diagnostic unit /DUE for type BF../BT.. brakes [1] Evaluation unit [2.1] Sensor 1 [2.2] Sensor 2 6.4. Connecting the sensors With brake BE.. With brake BF../BT.. 13

Setting and installing the evaluation unit 7. Setting and installing the evaluation unit If the diagnostic unit /DUE option has been ordered, function and wear monitoring is installed and calibrated in the factory. The customer connection still needs to be made, see wiring diagram. The diagnostic unit is now ready for operation. If the option is retrofitted, various settings need to be made. Setting of the max. working air gap Connection of the sensors to the evaluation unit Calibration Infinite value Installation of the sensors in the brake Calibration Zero value All work is described in detail in the respective operating instructions. 14

Notes 8. Notes 15