Timer Relays - Fixed & Adjustable

Similar documents
Timer Relays - Fixed & Adjustable

Timer Relays - Fixed & Adjustable

Warning Lamps. Bus Warning Light Kits 90. Headlights On Units 93. Flasher Units 94

Electronics. Voltage Converters 132. RCD/GPO Inverters 135. Pure Sine Wave Inverters 136. Combi Inverter/Chargers 138. AC to DC Battery Chargers 140

Sentry Governors. Class 1. Advanced Diagnostics. Sentry Governor Kits

Warning Lamps. Bus Warning Light Kits 110. Headlights On Units 113. Headlight Flasher 114

ICS Switch Panel. Introducing the new

Circuit Breaker Types

Reference Manual C1S Class 1 Systems

BF Series Flasher Thermal flasher circuitry

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Circuit Breaker Types

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Circuit Breaker Types

DEEP SEA ELECTRONICS PLC

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

SRC2013. Switches Relays & Circuit Protection

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Lighting Symbols. Rotating LED LED light source with rotating reflector. LED. Rotating Halogen Halogen bulb light source with rotating reflector.

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Transfer switch GTEC open or delayed transition

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

Power Conversion. Battery Chargers. Model

LED Technology. Evolution Design. Hybrid Drive. Lighting Symbols

Automotive Components Distributors. Airport Products. H. Bowers 2.00

Electronic Circuit Breaker ESS20-0..

REVISED ATM72 Auto Transfer Module

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Floodlights. XL-LED Performance IP66 Mini Floodlights 58 LED Weatherproof Floodlights 60

DEEP SEA ELECTRONICS PLC

OTEC Transfer switch open transition

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

pink relay trigger 12v wire - a fused ignition source relay trigger ground wire-to a good chassis ground to component

ELECTRICAL PANELS. Chap.

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

Application Engineering

Emergency lighting units EM powerled

The new and improved. Minebars

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

TOTALINE PROTECTION CONTROLS

Transmitters: Relay Valve

Item Number Amps Input Banks Price BI $ BI $95.30 BI $ BI $ BI $203.

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

Electropneumatic Timing Relays Series 7000 Industrial

Power Distribution System User s Manual. Model: PDS-100

INSTALLATION INSTRUCTIONS

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM powerled

Prism PI Intelligent features offer advanced performance

INSTALLATION GUIDE. FCC ID NOTICE

MCC Automatic Start-Stop Microcomputer Charger Control

RF-425LCD PROFESSIONAL VEHICLE SECURITY SYSTEM INSTALLATION MANUAL (FOR AUTHORIZED DEALERS ONLY)

Power Converters. Output Current Function Design Features

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

PSM72H Push-Button Start Module

Electro Wizard TM Battery Disconnect Switch

AR12 & AR20 Wiring diagram (multifunction display)

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

Selection Guide Motor Control Device Solutions

HIGH POWER SOLENOID DRIVER 1

Low and High Voltage Power Supplies

Installation Instructions

SDM72 Start on Demand Modules

Thermal Circuit Breaker 3120-F...

AUTOSTART 705S V1.00 AUTOSTART 710S / 720S / 730S V1.04 Programming Reference and Check Sheets

Application Engineering

Lighting Symbols 100 KM/H

Model PRO 9246CH Installation Manual

DEEP SEA ELECTRONICS PLC

All In one uninterruptible power supply solutions

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Installation Contactors RIC, RAC

CONSUMABLES POWER 099 POWER CONNECTIONS 108 FUSES 115 CIRCUIT BREAKERS 116 FUSE HOLDERS 126 RELAYS & FLASHER UNITS 131 SOLENOIDS 132 JUNCTION BOXES

CM4200 and CM1000S Starter Control Module Installation Manual

Emergency lighting units EM series

Transfer switch OTEC open or delayed transition

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

CM7200 Option Tables and Programming Instructions Firmware: v3.03

Transmitters: Relay Valve VR4151/4152

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

Gate & Door Controller with LCD and Intelligent Technology

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

CRITICAL SPARES GUARD LASER MURPHY RECOMMENDED PARTS 30%OFF ** GAUGES FATIGUE WARNING KIT NOW $ 10%OFF * 15%OFF * keep your fleet moving

MM1 Installation Instructions

CM7000 Option Tables and Programming Instructions Firmware: v3.03

DEEP SEA ELECTRONICS PLC

Transfer switch OTEC and OTECSE open transition

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning

Emergency lighting units EM powerled

CI-TI Contactors and Motor Starters Type CI 6-50

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Data Sheet. AmLok.

Relays Micro relays. Characteristic quantities. 6 Relays

Transcription:

Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing them to be multi-voltage and eliminating failures associated with mechanical components. This guarantees extremely quick switching times and outstanding service life. Manufactured with standard housing and terminal configurations ensures compatibility with standard mini relay accessories. Standard Coil Relay Weatherproof Relays Weatherproof relays seal to IP67. This protection rating is achieved by utilising a shrouded relay housing with an accompanying sealed connector. Offered individually or in kit form in normally-open or changeover configuration. r Relays - Fixed & r relays are microprocessor controlled change-over relay units incorporating a time delay. Depending on the model, the time delay can trigger in either a delay on or delay off configuration. User adjustable models are available ex-stock. Made to order factory preset units available by special order. (Minimum order quantities apply.)

Solid State 98 Mini & Micro 99 r 102 r - Factory Preset 104 High Current 106 Specials 107 Voltage Sensor 108 Keys On Lights On 109 Smart Battery Isolator 110 Solenoids 111 Turbo rs 112

Solid State Solid state reliability. 9-30V operation. Fast switching speed. Silent operation. No moving parts. Replacement to mechanical relays. Voltage : 12/24V Operational (9-30V) Contact : Brass Body : Polymer Ingress Protection : IP5K4 Supply Current : OFF State <0.5mA ON State 5mA Solid State Relay IONNIC Solid state relays have no moving parts, eliminating failures normally associated with conventional mechanical switching relays. Rated up to 25amps IONNIC Solid State relays provide faster switching time, improved reliability and the convenience of 12/24V operation. 40mm 30mm 30mm No Moving Parts - No Contacts + 30 + 30 31 15 31 15 Positively Triggered Negatively Triggered Solid State Part No. Voltage Switching Amps Continuous Max Switching PE14-10P 12/24 Positive 10 35 PE14-25P 12/24 Positive 25 100 PE14-10N 12/24 Negative 10 35 PE14-25N 12/24 Negative 25 100 For accessories see page 101. 98

Weatherproof Mini relays available - rated to IP67. Most models resistor protected. Full range of accessories available. Models available with mounting bracket. Contacts : Silver Alloy Body : Polymer Ingress Protection : Micro, Mini IP54 Mini - Weatherproof IP67 Operating Temp : -40 C to + 125 C P2512R P1524R P1424R PM2512R P1512RWP Mini & Micro 25mm 15mm a 23mm 4.8mm 85 30 85 30 PM2512R Fig 1 Fig 2 4 Terminal - Normally Open (N/O) 5 Terminal - Change Over (C/O) Micro Part No. Voltage Amps Contact Type Terminals Fig PM1412R 12 20 N/O 4 1 PM1424R 24 10 N/O 4 1 PM2512R 12 10/20 C/O 5 2 PM2524R 24 5/10 C/O 5 2 47002/10 47002 47003/10 47003 160927-4 281197-2 Accessories - Micro Part No. Description 47002/10 Micro relay base kit - 10 pack. Interlocking base with mounting bracket Contents: 10 x Bases (47002), 20 x AMP Terminals (160927-4), 30 x AMP Terminals (281197-2) 47002 Micro relay base. Interlocking base with mounting bracket 47003/10 Micro relay base kit - 10 pack Contents: 10 x Bases (47003), 20 x AMP Terminals (160927-4), 30 x AMP Terminals (281197-2) 47003 Micro relay base 160927-4 AMP Terminal -. Suits 1-2.5mm 2 cable size. 100 pack 281197-2 AMP Terminal - 4.8mm. Suits 1-2.5mm 2 cable size. 100 pack 99

P1512RWP P1512RWP-KIT 69mm 35mm a 35mm 85 30 85 30 Ø6mm Fig 1 5 Terminal - Normally Open (N/O) Fig 2 5 Terminal - Change Over (C/O) Mini - Weatherproof Part No. Voltage Amps Contact Type Terminals Mounting Bracket Fig P1512RWP 12 30 N/O 5 Removable 1 P1524RWP 24 20 N/O 5 Removable 1 P2512RWP 12 20/30 C/O 5 Removable 2 P2524RWP 24 10/20 C/O 5 Removable 2 P1512RWP-KIT 12V N/O Weatherproof Relay Kit Kits contain: 1 x Mini Weatherproof Relay P1524RWP-KIT 24V N/O Weatherproof Relay Kit 1 x Base Connector (12065685) 1 x Sealing Blank (114017) P2512RWP-KIT 12V C/O Weatherproof Relay Kit 2 x Terminals 1-2mm 2 (12066614L) 3 x Terminals 2-3mm 2 (12033997L) P2524RWP-KIT 24V C/O Weatherproof Relay Kit 12065685 12033997L 12066614L Accessories - Mini Weatherproof Part No. Description 12065685 Relay base connector 12033997L Packard Terminal - with pull to seat locking tab. Suits 2-3mm 2 cable size. 100 pack 12066614L Packard Terminal - with pull to seat locking tab. Suits 1-2mm 2 cable size. 100 pack 100

P1524R P1424R P2512R 41mm 26mm a 26mm 85 30 85 30 85 30 Fig 1 Fig 2 Fig 3 6mm 4 Terminal - Normally Open (N/O) 5 Terminal - Normally Open (N/O) 5 Terminal - Change Over (C/O) Mini Part No. Voltage Amps Contact Type Terminals Mounting Bracket Fig P1424R 24 20 N/O 4 Removable 1 P1512R 12 30 N/O 5 Removable 2 P1524R 24 20 N/O 5 Fixed 2 P2512R 12 20/30 C/O 5 Removable 3 P2524R 24 10/20 C/O 5 Removable 3 For bulk packs of 200, add -B to end of part number (eg P2524R-B). PRBC 47000/10 47000 47001/10 47001 47004 160927-4 Accessories - Solid State, Mini & r Part No. PRBC Description Mini relay base kit. Interlocking base with mounting bracket Contents: 1 x Packard Base, 5 x Packard Terminals 47000/10 Mini relay base kit - 10 pack. Interlocking base with mounting bracket Contents: 10 x Bases (47000), 50 x AMP Terminals (160927-4) 47000 Mini relay base. Interlocking base with mounting bracket 47001/10 Mini relay base kit - 10 pack Contents: 10 x Bases (47001), 50 x AMP Terminals (160927-4) 47001 Mini relay base 47004 Mini relay base. For mounting to PC boards 160927-4 AMP Terminal -. Suits 1-2.5mm 2 cable size. 100 pack 101

TIM01 TIM05 Programmable time periods. Compact units. 10A switching current on most units. Clean contacts. r PT40-205 Protection : Body : Resistor Polymer Delay Type 0: OFF - 0.5 secs - 10 secs 1: OFF - 5 secs - 60 secs 2: OFF - 30 secs - 10 mins 3: OFF - 5 mins - 60 mins 4: OFF - 30 mins - 6 hrs 5: ON - 30 mins - 6 hrs 6: ON - 5 mins - 60 mins 7: ON - 30 secs - 10 mins 8: ON - 5 secs - 60 secs 9: ON - 0.5 secs - 10 secs r - Delay Type Increase Decrease Delay ON Delay OFF + 15 a 41mm 30mm 30mm 31 30 30 - r Positive Supply (B+) 31 - r Negative (B-) 15 - r Switch/Control (B+) 5 Terminal - Change Over (C/O) Part No. Function Voltage Amps Delay PT40-205 Delayed turn OFF or Delayed turn ON 12 10 0.5 sec to 6 hrs pt40-405 Delayed turn OFF or Delayed turn ON 24 10 0.5 sec to 6 hrs For accessories see page 101. 102

Multi Function TIM01 Delay On/Off Red LED indicates when relay is energised. Increase Increase Switch 1: Specifies when timer activates. Decrease Decrease Switch 2: ON: Minutes OFF: Seconds Switch 1: OFF = Delay ON ON = Instant ON - Delay OFF 2: OFF = Once only ON = Cycle ON-OFF-ON-etc 3: OFF = Seconds ON = Minutes 4: OFF = 1-30 ON = 2-60 5: OFF = 24V ON = 12V ON 1 2 Temporary activation at Turn ON TIM05 ON 1 2 3 4 5 Temporary activation at Turn ON ON 1 2 Delayed Off ON 1 2 3 4 5 Delayed at Turn On ON 1 2 Delayed at Turn On TIM06 ON 1 2 3 4 5 Cycle activation at Turn ON ON 1 2 Temporary activation at Turn OFF 72mm 15mm 72mm 15mm 42mm + NC NO INH+ COM 6 Terminal - Change Over (C/O) + a 85 30 5 Terminal - Change Over (C/O) 43mm 30mm 30mm TIM01 TIM05, TIM06 Multi Function Part No. Function Voltage Max Amps @ 12V Delay TIM01 Multi 12-24 3 1 sec to 60 mins TIM05 Delayed turn OFF 12-24 10 1 sec to 60 mins TIM06 Delayed turn ON 12-24 10 1 sec to 60 mins Protected microprocessor timer control circuit. TIM01: Incorporates timer reset terminal. 103

C r - Factory Preset User defined factory preset time. Flexible time periods. Compact unit. Clean contacts. Removable mounting bracket. Non-stocked item - lead times & MOQs apply. Protection : Resistor Current Rating : 12V 20 Amps 24V 10 Amps Contact : Copper-Zinc Alloy Body : Nylon PA6.6 Ingress Protection : IP5K4 Operating Temp : -40 C to + 80 C Approvals : CE, RoHS 15 a 56mm 28mm 28mm 31 30 30 - r Positive Input (B+) 31 - r Negative (B-) 15 - r Switch/Control (B+) 6mm 5 Terminal - Change Over (C/O) Ordering System The fixed range of r Relays are programmed at the point of manufacture hence are a non-stocked item - lead times & MOQs apply. When ordering specify: - Type, - Voltage, -, - Seconds or Minutes. Minimum order quantity of 50 pieces. T20 T30 T31 T35 205-12 Volt 405-24 Volt Part Number T20-205-37 S (01-60) S - Seconds M - Minutes T20 T30 Delay ON With constant positive feed to terminal 15 Preset Delay OFF With constant positive feed to terminal 15 Preset T31 T35 Delay OFF With positive trigger to terminal 15 Preset Delay OFF With loss of positive to terminal 15 Preset 104

atalogu Catalogues Lighting WL 2011 WL2011 Heavy Duty LED Heavy Duty HID Heavy Duty Halogen Marine General Purpose HID Driving Lights Interior Lighting Worklamps To get your copy visit ionnic.com EL 2011 EL2011 Available 2nd Qtr 2011 LED & Halogen Beacons Strobes Lightbars Minebars ROPS Bar Directional Arrows LED Lighting Bus Warning Light Kits Flasher Units Emergency Lighting To get your copy visit ionnic.com Available 2nd Qtr 2011 Lighting Safety Electrical

High Current P141270 PR12V200 P141275HD High current power relays. Models available up to 200A. Various mounting styles. Contacts : Silver Alloy Body : Polymer Operating Temp : -40 C to + 100 C Ø6mm 46mm 62mm 45mm 76mm Ø6mm Ø6mm 28mm 46mm 85 30 4 Terminal - Normally Open (N/O) 75mm 34mm 85 30 4 Terminal - Normally Open (N/O) PR12V200, PR24V100 P141275HD, P142450HD Power Part No. Mounting Bracket Voltage Amps Contact Type Terminals PR12V200 Fixed 12 200 N/O 4 PR24V100 Fixed 24 100 N/O 4 P141275HD Fixed 12 75 N/O 4 P142450HD Fixed 24 50 N/O 4 41mm 28mm 26mm Ø6mm 9.4mm 85 30 4 Terminal - Normally Open (N/O) Mini - Power Part No. Mounting Bracket Voltage Amps Contact Type Terminals P141270 Removable 12 70 N/O 4 106

Flag indicator shows relay status in manual or powered condition. Bipolar LED status lamp allows for reverse polarity applications - ideal in low light conditions. Colour-coded push button with lock-up door - allows for manual operation of relay without the need for coil power. White polymer ID tag for labelling in multirelay circuits. Protection : Resistor Contacts : Silver Alloy Body : Polymer Ingress Protection : IP40 Operating Temp : -40 C to + 55 C Approvals : CSA, CE, RoHS Specials 40mm 21mm 13 1 5 2 6 3 7 4 8 28mm 14(-) 9 10 11 12 2.5mm 14 Terminal - Change Over (C/O) 4 Pole Change Over Part No. Coil Voltage Amps per Contact Contact Type Terminals P4512 12 4 C/O 14 P4524 24 4 C/O 14 With P4512 mounted Accessories - Specials Part No. Description Amps Terminal No. of Poles Receptacle 47006 Relay base 7 M3 Screw 4 14 Blade 107

Voltage Sensor Internal change-over relay activates when the voltage falls below or rises above the preset level. sensing range: VS12-9-16V operation. VS24-18-35V operation. Example uses: - Helps prevent the over-discharging of a battery. - Triggering an alert when a battery discharges to a preset level. - Automatic activation of a battery charger. Body : ABS Wire Length : 300mm Operating Temp : -0 C to + 50 C + NC NO IC - COM Voltage adjusting screw 5 Terminal - Change Over (C/O) 50mm 70mm 30mm 24mm Voltage 11 Voltage 11 On a Rising System Voltage* Energises 12 12.7 11.5 12.5 User Set Point On a Falling System Voltage* De-Energises 12 12.7 11.5 12.5 User Set Point *VS12 operation illustrated with default User Set Point. 13 13 Used to switch a circuit relative to system voltage. The user only sets the minimum voltage level (User Set Point). The VS12 maximum voltage level is approximately +0.7 volts higher than the User Set Point. The VS24 maximum voltage level is approximately +1.5 volts higher than the User Set Point. When the system voltage reaches the maximum voltage level the internal change-over relay energises switching the COM from NC to NO. When the system voltage falls below the minimum voltage level the internal relay de-energises switching the COM back to NC. Voltage Sensor Part No. Voltage Amps Sensing Range (volts) Factory Trigger Setting Minimum Voltage Maximum Voltage VS12 12 10 9.0-16.0 12.0 ± 0.2 12.7 VS24 24 10 18.0-35.0 24.0 ± 0.2 25.2 108

Allows normal operation of headlights. Designed to operate park & low beam lights any time vehicle ignition is on. Input available to disable control unit, eg. handbrake switch, door switch. All three internal 30 amp relays turn on 10 seconds after ignition is activated. Compact easy installation. MS-LOR-12V features diagnostic LEDs. MS-LOR-12V-KIT supplied with harness to plug into Toyota Hi-Lux headlight system. 2 year warranty. Body : ABS Wire Length : 300mm MS-LOR-12V 200mm Operating Temp : -0 C to + 50 C MS-LOR-12V -0 C to + 85 C MS-LOR-12V KOLO12DU Keys On Lights On mm 48mm MS-LOR-12V 95mm 24mm 94mm 68mm MS-LOR-12V-KIT - Easy Installation MS-LOR-12V-KIT Keys On Lights On Controller is exceptionally easy to install. Kit is supplied with plug-in harness to suit Toyota Hi-Lux. Ø5mm 40mm 88mm 32mm Plugs directly into headlight harness 107mm Kits suiting other vehicles under development. KOLO12DU, KOLO24DU Keys On Lights On Controller Part No. Voltage Description MS-LOR-12V 12 Suits any negativeley switched headlight MS-LOR-12V-Kit 12 Suits Toyota Hi-Lux only. Supplied complete with plug-in harness KOLO12DU 12 Suits any negatively earthed vehicle KOLO24DU 24 Suits any negatively earthed vehicle 109

Smart Battery Isolator SBI-12 1315-200 Microprocessor-controlled battery isolator designed for use in multi-battery applications. Cost-effective protection against a flat battery. Cooler operating temperature. Silver alloy contacts for longer life. Power saving technology. Fault indication. Surge-protected. 2 Year warranty. Body : Polymer Contact : Silver Alloy Operating Temp : SBI -0 C to + 50 C 1315-200 -40 C to + 60 C Ø7mm 83mm Ø8mm 102mm 7mm 83mm 103mm 74mm 54mm Ø8mm 51mm 55mm 1315-200 SBI-12, SBI-24 Smart Battery Isolator Part No. Voltage Amps Inrush Continuous Off Volts On Volts Current Draw (Amps) 1315-200 12 600 200 12.8 13.2 0.13 SBI-12 12 400 100 12.7 13.2 0.15 SBI-24 24 400 100 25.4 26.4 0.15 110

Range of normally open & change over style contacts. Integrated mounting brackets. 12 & 24 volt models available. 15-323 Fig 1 4 Terminal - Normally Open (N/O) Fig 2 6 Terminal - Change Over (C/O) ST85 Solenoids Fig 3 4 Terminal - Normally Open Includes Auxiliary Output (N/O) 15-3F 55mm Ø7mm 59mm 55mm Ø7mm Ø8mm Ø5mm 7mm 55mm Ø8mm Ø5mm Ø8mm 60mm 89mm Ø8mm Ø5mm 55mm 70mm 89mm 83mm 70mm Fig 1 Fig 2 Fig 3 Solenoids Part No. Voltage Amps Duty Contact Type Fig ST85 12 80 Continuous N/O 1 ST88 24 80 Continuous N/O 1 15-132 12 100 Continuous N/O 1 15-269 24 100 Continuous N/O 1 15-133 12 200 Continuous N/O 1 15-141 24 200 Continuous N/O 1 15-323 12 100/100 Continuous C/O 2 15-326 24 100/100 Continuous C/O 2 15-3F 12 200 Intermittent N/O 3 111

Turbo rs BES-124/ST-4 CST-515 Multiple mounting options. Energise to run or stop models. Models with remote face. 5 Minute Fixed models feature 30A switching capacity via serviceable external relay. 12-24V operation. BES-925/ST-1 Voltage : 12-24V Current Rating : 10 Amps max BES-925/ST1 91mm 24mm 25mm 29mm 50mm 130mm Remote Face - Part No. Outputs Energise to Remote Face Intervals (mins) Park Brake Override Description BES-925/ST-1 1 Run yes 0.5, 1, 2, 3, 4, 5 yes Non-electronic engine management BES-925/ST-4 1 Run yes 0.5, 1, 2, 3, 4, 5 yes Electronic engine management BES-925/ST-5 2 Run yes 0.5, 1, 2, 3, 4, 5 yes Electronic engine management CTR-M 1 Stop yes 0.5, 1, 2, 3, 4, 5 no Electronic engine management 112

33mm 25mm 54mm 75mm BES-124/ST4 Part No. Outputs Energise to Remote Face Intervals (mins) Park Brake Override Description BES-124/ST-1 1 Run no 1, 3, 5 no Non-electronic engine management BES-124/ST-2 2 Run no 1, 3, 5 no Non-electronic engine management BES-124/ST-4 1 Run no 1, 3, 5 no Electronic engine management 112mm 52mm 58mm CST-515 Gauge Mount - Fixed Part No. Outputs Energise to Remote Face Intervals (mins) Park Brake Override Description CST-500 1 Run no Fixed @ 5 no Relay driven output CST-515 1 Stop no Fixed @ 5 no Relay driven output 113