Orbital Shaker-Incubator ES-80

Similar documents
UV-cabinet DNA/RNA UVC/T-M-AR

UVR-Mi UV-air flow Cleaner - Recirculator

Instruction Manual. Vortex Mixers

ORBITAL SHAKER. Note: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Lab Rotators and Low Cost Orbital Shakers

Flask shaker SF1. Instructions for use Manuel d'utilisation Istruzioni per l uso Instrucciones de funcionamiento Bedienungsanweisung. Version 2.

Incubators. Incubators

Model 700 Microarray Oven

PNA FISH Workstation Operating Instructions

Operating Manual. Operating Manual HYBRIDIZATION INCUBATOR. combi-h12 combi-d24 combi-v12 combi-sv12 combi-sv120

Rockers, Rotators and Mini Shakers

Shaking Incubators & Shakers

Rockers &Shakers Shakers

Heavy Duty Orbital Shakers

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual

CLEMENTS. Orbital 160 Benchtop Centrifuge. CEN V 50Hz. User Manual. Manual No. CEN Issue 4

FlexChem Model 404 Rotating Oven

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL

Fisher Scientific. Rockers, Rotators and Shakers

11 Thermoshakers. Thermoshaker with cooling. Thermoshaker. Thermoshaker for microplates. PCMT for microtubes and microplates

CLEMENTS. Orbital 260 Benchtop Centrifuge. CEN V 50/60Hz. User Manual. Manual No. CEN Issue 5

Operation Manual. H6000 Series

3-D GYRATORY ROCKERS.

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

Operating Instructions For The X-Seal Manual Thermal Sealer

10 Thermoshakers. Thermoshaker with cooling. Thermoshaker. Thermoshaker for microplates. Thermoshaker for deep well plates

OPERATING INSTRUCTIONS. Models SI-1400 through SI-1406

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Techcon Systems TS500R-PC Controller For Positive Displacement PC Pump

XCM12 Mini-Centrifuge

Register your instrument! MiniSpin /MiniSpin plus. Operating manual

OPERATION and MAINTENANCE INSTRUCTION MANUAL

Hybex Microsample Incubator

Bedienungsanleitung Schüttler KM. Operating Instructions Shaker KM. Mode d emploi Agitateur KM KM 2 KM 2 AKKU KM CO 2 VERSION 04 / 2016

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Digital incubating/ refrigerating benchtop shakers.

1.Safe testing IMPORTANT:

GLASSCO LABORATORY EQUIPMENTS PVT. LTD.

Operating instructions Platform/floor scales

k ual I24/24R Benchtop Incubator Shaker N) manual New Brunswick I24/24R Benchtop Incubator Shaker Operating manual

Register your instrument! HeatSealer S100. Operating manual

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Techcon Systems TS6500 CIM Automatic Techkit Mixer

MX-S/MX-F Vortex Mixers

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

P. D. Q. Automatic Burnout Furnaces. 115 and 230-volt Models OPERATOR S MANUAL

Bio Lion Table Top Centrifuge XC-H165

Centrifuge, Mini-micro New, Pro-micro New, Table-top Classic New, Table-top Microprocessor New

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Unit 2, Rivington View Business Park, Station Road, Blackrod, Bolton BL6 5BN Tel: +44(0)

ISO-9001:2008 HOT PLATES CATALOG. Phone: Fax: Web:

DIGITAL RCD(ELCB) TESTER

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

SciQuip Benchtop Shakers

SPECIFICATIONS. Vortex-Genie Model Vortex-Genie 1 Vortex-Genie 2 Supplied Pop-off Cup 3-inch Platform, Pop-off Cup 3200

LM series. LE series. DK series. TS series. BH BU BL BT series. GC series. DS series. LR series

SPECIFICATIONS. Vortex-Genie Model Vortex-Genie 1 Vortex-Genie 2 Supplied Pop-off Cup 3-inch Platform, Pop-off Cup (2700 for 50Hz models)

Centrifuge. Model XC-2000 Operating Manual

Centrifuge. Model XC-1000 Operating Manual

Infinity Burnout Furnaces

Prism Microcentrifuge

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge

DC POWER SUPPLY ALIMENTATION C.C.

Declaration of Conformity

grantsciukv15a_catalogue 17/06/ :14 Page Centrifuges

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200

Magnetic Stirrer POWER DIRECT. Operating Manual Issue

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

DRY BATH INCUBATOR (HEATING BLOCKS) Model: DB-005, DB-006, DB-006E

2016 Catalogue. Shaker. v1.0

NT-500 Technical Support Guide. For use by qualified company approved Technicians

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd.

5.2 PRE-OPERATION PROCEDURE WARRANTY

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

LED Twister II. User manual UK Version 1.0

Heiland electronic GmbH TAS

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Product Overview of GYROZEN Centrifuges

Bio Lion Table Top Centrifuge XC-L5

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Easy to use! Smart, practical instruments which are robust and reliable, and fit on any laboratory bench. STIRRERS DRY BATH INCUBATORS MIXERS

Model HT Microplate Orbital Shaker With Manual Adjustment Knobs. Product Manual

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

Vacuum Evaporator with optional separate remote controller with or without shaking feature page 2 page 3 page 3. Incubator with cooling feature

9120 EBCU Battery Charger MODELS: 9120EBCU96V 9120EBCU240V

Refrigerated incubator with Peltier technology

KEWTECH. KT56 digital multi function tester. Instruction manual

Rental Industry Safety Tester Safe Check 5s

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:

624R User s Manual. Compact Bench-Top Refrigerated Centrifuge

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Exceptional Choice for Versatile and Reliable Shaking Application

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

Transcription:

Orbital Shaker-Incubator For versions: V.2GD V.2GE

Contents 1 Safety...3 2 General Information...4 3 Getting Started...5 4 Operation of...6 5 Specifications...8 6 Guarantee and service...9 7 Declaration of Conformity...11 Page 2

1. Safety The following symbol means: Caution! Read this operating instruction fully before use and pay particular attention to sections containing this symbol. GENERAL SAFETY Operation of the unit must be carried out according to the given operating manual. The unit should not be used if dropped or damaged. The unit must be stored and transported only in a vertical position (see marking on the package). After transport or storage in humid conditions dry out the unit (2-3 hrs) before connecting it to the supply voltage. Before using any cleaning or decontamination method except those recommended by the manufacturer, user should check with the manufacturer that the proposed method will not damage the equipment. Do not attempt to modify the unit. ELECTRICAL SAFETY Connect only to the mains with voltage corresponding to that on the serial number label. Do not plug the unit into the mains outlet without grounding, and do not use extension lead without grounding. Ensure that the mains switch and plug are easily accessible during use. Before moving, disconnect the unit from the mains outlet. To turn off the unit, disconnect the power plug from the mains outlet. If liquid is spilled inside the unit, disconnect it from the mains and have it checked by a competent person. DURING OPERATION Do not impede the platform motion during operation. Do not operate the unit if you think it may have been incorrectly installed or repaired. For indoor use only. Do not use outside laboratory rooms. Do not place a load exceeding maximum loading mentioned in ref p 8 Specifications. Do not operate the unit if it is faulty or been incorrectly installed. BIOLOGICAL SAFETY It is the user's responsibility to carry out appropriate decontamination if hazardous material is spilt on or inside the equipment. Page 3

2. General Information Orbital Shaker-Incubator for biotechnological and pharmaceutical laboratories is a professional category equipment designed for the cultivation of micro organisms, cells and eukaryotic cells including animal, plant and insect cells. The shaker is equipped with a direct-drive mechanism for platform motion. It provides reliable and stable operation for the long term experiments needed for cell growth. Orbital Shaker-Incubator provides even (or vigorous) mixing in flasks installed on the platform. A built-in thermoresistant brushless fan provides precise temperature distribution inside the chamber (adjustable from +10 C above room temperature up to +80 C). The chamber inside is made of stainless steel. A state-of-the-art motor, latest thermal insulation materials, soft-start of the platform motion and temperature PID-control, decrease the energy consumption and make the shakerincubator highly energy efficient despite its relatively large size. Page 4

3. Getting started 3.1. Unpacking Remove packaging carefully, and retain for future shipment or storage of the unit. Caution! Due to its size and weight (43 kg) the unit requires two people to lift or move it. 3.2. The set includes Orbital Shaker-Incubator...1 piece Power cord...1 piece Spare fuse (inside fuse holder)...1 piece Four screws and a hex key...1 set Operating Instructions; Declaration of Conformity...1 copy Optional accessories: Platform P30-100 u...on request Platform P16-250 v...on request Platform P9-500 w...on request Platform P6-1000 x...on request Platform PP-400 y...on request 3.3. Set up: - place the unit on an even horizontal non-flammable surface away from any flammable materials (not less than 30 cm); Note! Ensure that the unit is placed on solid, level surface, which is able to support it s weight. - plug the mains cable into the socket on the rear, and position the unit so that there is easy access to the power switch and plug. Page 5

4. Operation of SET PARAMETERS 00:25 160 37.00 STOP 000 37.00 Time (hr:min) RPM Temp. C RPM Run/Stop Time RPM Temp. Timer Fig.1 Control panel 4.1. Connect the power cord to the mains outlet which provides a safety earth (ground) terminal. Set the Power switch in position I (ON) on the front side. 4.2. The display will turn on with the upper line showing time, speed and temperature set earlier and the lower line showing current readings of the same parameters (thermoblock temperature C, which automatically starts rising according to the temperature set in the upper line). How to set the necessary parameters Use the readings in the upper line of the display, while setting the necessary parameters. Time set (Time) 4.3. With the help of and Time keys (Fig. 1/u) set the required working time interval in hours and minutes (increment 1 min). If the key is pressed more than 2 sec the increment becomes bigger. Page 6

Speed set (RPM) 4.4. With the help of and RPM keys (Fig. 1/v) set the required shaking intensity in revolutions per minute (increment 10 RPM). If the key is pressed more than 2 sec the increment becomes bigger. Temperature set (Temp.) 4.5. With the help of and Temp. keys (Fig. 1/w) set the necessary temperature (increment 0.1ºC). If the key is pressed more than 2 sec the increment becomes bigger. The set parameters can also be changed during operation. Caution: It is possible to turn off heating only by setting the required temperature below 25 C. Program execution 4.6. Fix the vessels on the platform. 4.7. Press the RPM-Run/Stop key (Fig. 1/x). The platform will start rotation and the timer indicator will start counting up the time interval (with 1 min precision). Please note: If the speed is set to zero, pressing RPM-Run/Stop key starts the timer, but the platform does not move. 4.8. At the end of the program (after the set time elapses) the platform motion stops and the timer shows the flashing reading STOP accompanied by the repetitive sound signal until the RPM- Run/Stop key is pressed. 4.9. If the working time is not set (or deleted) and the timer indicator in the upper line shows 00:00, pressing the Timer-Run/Stop key cause the unit to operate continuously until the Timer-Run/Stop key is pressed again. Caution: At the end of the set time period the platform movement is stopped automatically, but the heating can be stopped ONLY manually by reducing the temperature with the q Temp. key (Fig. 1/w- lower key) till the OFF sign appears in the upper line of the display. 4.10. If required, it is a possibility to restart the timer when it is running. Press the Timer-Run/Stop key once (Fig. 1/y) to stop the timer. Press the Timer-Run/Stop key again to restart the timer. 4.11. The platform motion can be stopped at any time by pressing the RPM-Run/Stop key. In this case the program and the platform motion stops and timer is set back to zero switching into the STOP mode. Press the RPM-Run/Stop key to repeat the operation with the same time and speed. 4.12. At the end of operation set the Power switch in position O (Off). Disconnect the power cord from the mains outlet. Page 7

5. Specifications The product is designed for operation indoors in a laboratory at altitudes up to 2000 m, with ambient temperature from +4 C to +40 C and maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C. 5.1. Temperature specification Temperature regulation range...+25 C... +80 C* (increment 0.1 C) Temperature control range...10 C above ambient... +80 C Temperature stability...±0.5 C Heat up time till max. temperature inside the flasks...90 min 5.2. General specification Speed setting range...50-250 RPM (increment 10 RPM) Digital time setting...1 min - 96 hrs (increment 1 min) / non-stop Maximum continuous operation time...30 days Recommended interval between operation sessions not less than 8 hours Maximum loading...8 kg Orbit...20 mm Display...2x16 signs, LCD Dimensions...590x525x510 mm Dimensions of the inner chamber...460x350x400 mm Operating voltage/ power consumption...230 V, 50/60 Hz / 450 W (2 A) or 120 V, 50/60 Hz / 450 W (4,5 A) Weight w-out platform, not more...43 kg Optional accessories P30-100 P16-250 P9-500 P6-1000 PP-400* Description Platform with clamps for 30x100 ml flasks, working dimensions 360x400 mm Platform with clamps for 16x250 ml flasks, working dimensions 360x400 mm Platform with clamps for 9x500 ml flasks, working dimensions 360x400 mm Platform with clamps for 6x1000 ml flasks, working dimensions 360x400 mm Flat platform with non-slip rubber mat, working dimensions 360x400 mm * Do not use rubber mat on the PP-400 at temperatures above 42 C. Grant is committed to a continuous programme of improvement, specifications may be changed without notice. Page 8

6. Guarantee and Service 6.1. Guarantee When used in laboratory conditions and according to these working instructions, this product is guaranteed for TWO YEARS against faulty materials or workmanship. 6.2. Service There are no user-serviceable parts inside the unit. For all maintenance and repairs (except as defined below) return to our service department in the UK or in other countries, our distributor. Cleaning Standard ethanol (75%) or other cleaning agents recommended for cleaning and disinfection of the stainless steel surfaces. The door s window is made of of organic glass (poly (methyl methacrylate) Plexiglass ) and is prone to scuffing and scratches if improperly cleaned. Care during cleaning of the door s window is recommended to reduce wear of the Plexiglass surface. Caution! Clean the door s window with a mild detergent; never use organic based compounds, pure alcohol, alcohol-containing cleaners (more than 15 %) or Ammonia containing cleaners for Plexiglass! Do not use abrasive pads or cleansers. For decontamination, it is recommended to use a special DNA/RNA removing solution (e.g. DNA-Exitus PlusTM, RNase-Exitus PlusTM). The table below shows the interreaction of Plexiglass with ethyl alcohol and other solutions. Liquid DNA-Exitus PlusTM RNase-Exitus PlusTM Ethyl alcohol 10-15 % Interreaction with Plexiglass No reaction. No reaction. No reaction. Ethyl alcohol 30 % Limited reaction. Ethyl alcohol Pure H O 6% 2 2 Full reaction. Do not use! No reaction. Standard ethanol (75%) or other cleaning agents recommended for cleaning and disinfection of the stainless steel surfaces. Page 9

Fuse replacement Disconnect the device from the mains power supply. Disconnect the power cable from the socket on the rear of the shakerincubator. Open the fuse holder. Replace with the correct fuse (for 230 V, 50/60 Hz - T3.15 A, for 115 V, 50/60 Hz - T6.3 A). 6.3. Routine safety tests If routine tests are to be made, we recommend a test of the integrity of the protective earth conductor and an insulation test at 500 Vdc. Routine flash tests are not recommended for any electrical equipment, because repeated high voltage tests degrade insulation materials. Fig.2 Fuse replacement Page 10

Page 11

Grant Instruments (Cambridge) Ltd Shepreth Cambridgeshire SG8 6GB UK Tel: +44 (0) 1763 260811 Fax: +44 (0) 1763 262410 Email: scientificsales@grantinstruments.com www.grantinstruments.com Environmental Shaker-Incubator//2.01