EZ SDI TM Booster Pump Assembly

Similar documents
EZ SDI-1 TM. Installation and Operating Manual. Distributed By:

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

ODY-19-1 AIR PRESSURE GAUGE

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

CHIP. Reverse Osmosis System Controller Documentation

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

INSTALLATION/OPERATING INSTRUCTIONS TSC

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Model LA 4300 Time Delay OFF Controller

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

1 AMP CURRENT SOURCE

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

Model LA 4100 Time Delay OFF Controller

Operators Manual. Recirculating Chiller /06/08

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

CTFRP Series Power Supplies

OPERATION AND MAINTENANCE

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

MityFlex Peristaltic Pump

2009 MFJ ENTERPRISES, INC.

POWER PINNER RAPID FIRE 7005 RF OPERATOR S MANUAL

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual

Model LA 4400 Time Delay OFF Controller

EBS PRODUCTS

OWNERS MANUAL JANUARY 2007 ISO

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

SUPER PUMP OUT SYSTEM

Electrical Control Panel

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual

Installation and Operating Manual

WARNINGS, CAUTIONS AND NOTES

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

ADI-125/750 ADI-125/1500 ADI-125/2500

RU BMS Power Supply and Battery Management System Owners Guide

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

INSTALLATION & OWNER'S MANUAL

BMRX Series ROTARY LEVEL CONTROL

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Patient Care Facility

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

G8 Portable Fuel Transfer Pump Owner s Manual

HLY-1111 HEAD TEMPERATURE GAUGE

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

Phase Sequence Tester

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

GENESIS POWER AUSTRALIA PTY.LTD Wheel Barrow Operating Manual

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

HR-20P Pneumatically Controlled Pressure Regulator

ESE Series Cast Iron Sewage Pumps

Model: ACP-12 AUTO COMPRESSOR PUMP SYSTEM 12 VDC INSTALLATION & OPERATION MANUAL. Phone:

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

STC 2L Series Solenoid Valves

Loctite 300ml Cartridge Pusher Part Number EQUIPMENT Operation Manual

Sivoia QED R Installation Instructions Please Leave for Occupant

Item no Smart AC 200 USB. User s Manual

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

F PRO. 12 Volt Battery Powered Sprayer LIMITED WARRANTY. Part #AS75 Copyright 2014 by Hydro-Force Rev. 1/14

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

RECHARGE STATION OPERATION MANUAL. Version

Sentry Battery Charger. Installation and Operations Manual Section 75

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

Installation Manual for the SHURflo LCB - G Pump Controller

DOMINATOR FUEL PUMPS P/N & Installation Instructions 199R10573

CTRC Series Flexible Rogowski Current Transformer - Installation Guide

GENESIS POWER AUSTRALIA PTY. LTD 3WheelBarrow Operating Manual

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

OWNERS MANUAL JANUARY 2007 ISO

Installation Instructions

SUPER 30 AUTO EJECT 30 AMP MODEL #: AUTOMATIC SHORE LINE DISCONNECT INSTRUCTION MANUAL

User s Guide Includes Mounting, Installation, and Product Registration

Type Maxi Mix III Rotary Shaker

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Electronically Commutated Motor Wiring Manual

HOLLEY VR2 FUEL PUMPS P/N & Installation Instructions 199R10975

MOTORTRONICS Solid State AC Motor Control

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

Model 605 Portable Aspirator

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

TPAK Series COOLANT PUMP

Operators Manual ECO-AIR-IVS Internal Valve Actuation System

RK Standby Battery Operator s Manual

WARRANTY INFORMATION...

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

PowerFLO 5800/5900 Series

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Transcription:

EZ SDI TM Booster Pump Assembly Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email: info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828

Manual Revisions i EZ SDI TM Automatic Booster Pump Assembly Installation and Operating Manual Copyright 2004 RODI Systems Corp. NOTICE This manual is protected by federal copyright laws. It should not be copied in any way, shape, or fashion without the written permission from RODI Systems Corp. Version 1.00 RODI Systems Corp. 936 Hwy 516 Aztec, NM 87410 505-334-5865

Version Log Version Date Effective Pages Description of Changes 1.00 06/10/04 - Original Issue

Conventions and Symbols ii Special characters, listed and described below, are used in this documentation to emphasize certain information. Note: Emphasizes additional information pertinent to the subject matter. Warning: Emphasizes information about actions, which may result in personal injury.! Caution: Emphasizes information about actions, which may result in equipment damage. The following electrical symbols may be used in this documentation. Symbol Meaning Direct current. Alternating current. Both direct and alternating current. Earth (ground) terminal. Frame or chassis terminal.

General Limited Warranty iii Warranty 1. In no event will RODI Systems Corp., or any of its representatives, be responsible or liable for indirect or consequential damages resulting from the use or application of any product. The user and those responsible for applying the product must satisfy themselves with the acceptability of the application. 2. RODI Systems Corp. extends a one (1) year warranty covering parts and labor on any factory manufactured product. Any product, which is found to have a defect in workmanship or components, shall be replaced or repaired at the option of RODI Systems Corp. 3. A prepaid minimum inspection fee is required for the repair of products not covered by the warranty period. Contact RODI Systems Corp. for repair information and repair rates. 4. RODI Systems Corp. will not be responsible for replacement or repair of any product that was damaged by improper installation, mishandling, or user modifications. 5. All units returned for repair must have a RA (return authorization) number obtained from RODI Systems Corp. This RA number must be included with the returned product and any correspondence regarding the returned product must reference that number. Shipping on all returned products must be pre-paid and insured. RODI Systems Corp. will not be responsible for any shipping damage incurred. Repaired products will be shipped pre-paid and insured. 6. RODI Systems Corp. reserves the right to change any specification or feature of any product at any time. This right also extends to repair fees or any warranty conditions contained herein.

Table of Contents iv EZ SDI TM Booster Pump Assembly 1 Introduction 1-1 Features 1-1 Specifications 1-1 Installation and Operation 2 Environmental 2-1 Mounting 2-1 Power 2-1 Ground 2-2 Signal 2-2 Water 2-2 Operation 2-2

1 EZ SDI TM Booster Pump Assembly Overview 1 1 Introduction The EZ SDI TM Booster Pump Assembly is designed to automatically boost the sample pressure for the EZ SDI-1 TM during the test process. This allows the EZ SDI to be used on low pressure sample points of the pre-treatment system. 24 Volt AC Transformer Sample Booster Pump INSIDE VIEW ACN IMPORTANT This product wired for! 230 VAC, 50 Hz. Model Number: SDI Sequencer Serial No. : 0112000000000007 936 Hwy 516 Aztec, NM 87410 505-334 -5865 Terminal Blocks Features The EZ SDI TM Booster Pump Assembly incorporates the following features: One sample booster pump which allows the sample to be taken from points under low pressure. One 24 VAC transformer for powering the booster pump. One 24 VDC relay allowing the booster pump to be automatically controlled by the Booster Pump Assembly of the EZ SDI unit. Specifications The EZ SDI TM Booster Pump Assembly incorporates the following specifications: Power Requirements: The controller requires 120 volts AC, 60 Hz, single phase, 1 amp maximum (or 230 volts AC, 50 Hz, 0.6 amp maximum). Flow Requirements: 500 ml / Min. 5-60 PSI

1-2 Tubing connections: The two tubing connections located at the bottom and top of the pump are as follows: 1 feed water connection: 3/8 poly tubing 1 supply connection: 3/8 poly tubing, requires a 1/4 x 3/8 Fast & Tite connector on the EZ SDI-1 TM. The sample booster pump will only run while a test is being conducted by the EZ SDI-1 TM. Environment: The controller can operate at a temperature from 0 to 55 C (32 to 131 F). Relative humidity must not exceed 95 percent.

Installation and Operation 2 Environmental The EZ SDI TM Booster Pump Assembly is mounted onto a flat wall or panel surface. The unit should be mounted as close to the EZ SDI-1 TM as possible. The Booster Pump Assembly should not be used in explosive environments. General environmental specifications are listed below. Environmental Specifications Specification Rating Storage Temperature -20 to 70 Deg C Ambient Operating Temperature 0 to 55 Deg C Ambient Humidity 30% to 95 % Relative Humidity (Non-Condensing) Mounting When mounting the Booster Pump Assembly, sufficient room should be allowed on the top and bottom of the device for access to the supply and sample connections. Mounting dimensions are shown below. 14.00" Dimensions to Enclosure Mounting Feet 12.50" Power A power cord is supplied for 120 VAC applications. The Booster Pump Assembly has internal circuit protection on the incoming power supply in the form of a DIN rail-mounted fuse holder. Only 5mm x 20mm fuses should be used. If the supplied power is to be hardwired to the Booster Pump Assembly, the power terminals are located on DIN rail below the pump (see figure at right). AC line is connected to the fuse holder. AC neutral is connected to the blue neutral terminal block. Ground is connected to the yellow and green ground terminal block. Power should always be disconnected from the Booster Pump Assembly before making or changing any connections. AC Line Ground ACN AC Neutral

2-2 Ground Signal Water A good common ground reference (earth ground) is essential for safe operation of the Booster Pump Assembly. A good earth ground or power circuit ground should be connected to the green and yellow ground terminal block. If a power cord is used, the ground terminal on the power cord must be grounded. The signal cable is pre-wired to the Booster Pump Assembly. The connector on this cable should be connected to the sample interface signal connector on the left side of the EZ SDI-1 TM control enclosure. The EZ SDI TM Booster Pump Assembly has two water connections on the pump. Connect the 3/8 discharge tubing to the pump by running the tubing through the compression fitting on the top of the assembly enclosure and into the push fitting on the pump. Tighten the compression fitting to prevent any leaks from running down the tubing into the assembly enclosure. A 1/4 NPT x 3/8 tubing connector should be installed in the supply connection fitting of the EZ SDI-1 TM allowing the 3/8 tubing from the booster pump to supply the EZ SDI unit. Connect the 3/8 suction tubing by running the tubing through the 7/8 hole on the bottom of the assembly enclosure and into the push fitting of the pump. The sample source connected to the Booster Pump Assembly should be able to provide a minimum of 500 ml per minute at 5 60 psi. Do not feed more than 60 psi to the sample inlet connection of the pump.! The EZ SDI-4 TM is designed to operate on Reverse Osmosis feed water. This feed water should be pretreated to remove particles above 160 microns in diameter. The use of feed water with particles over 160 microns in diameter can result in plugging of the regulator or vent orifice. If the regulator or vent orifice becomes plugged then the unit will malfunction and produce invalid results. Operation After making all connections to the Booster Pump Assembly (power, signal, sample, and supply) make sure that all valves are open supplying the sample to the pump suction connection. Operate the EZ-SDI-1 TM following the instructions supplied with the SDI monitor. The sample booster pump will only run while a test is being conducted by the EZ SDI-1 TM (while water is passing through the filter). It will be necessary to adjust the SDI test pressure of the EZ SDI unit while the booster pump is running during the test.