Final Report. Competitive Analysis: Levelized Cost of Electricity (LCOE) Rev C: January 24, 2008

Similar documents
BEACON EQUITY RESEARCH

PV Systems Modeling and Analysis Tools

SOLAR TRACKER SITE DESIGN: HOW TO MAXIMIZE ENERGY PRODUCTION WHILE MAINTAINING THE LOWEST COST OF OWNERSHIP

Photovoltaics Outlook

Why Is My PV Module Rating Larger Than My Inverter Rating?

LAYOUT REPORT OF GROUND MOUNTED PROJECT

Enabling Utility Scale PV: Challenges for Glass Makers

Thomas Alston Director of Business and Policy Development. Presented By N. Scottsdale Rd, Suite 410 Scottsdale Arizona 85257

Energy Savings through Solar Energy for Municipalities

LAYOUT REPORT OF ROOFTOP PROJECT. For 115 kwp. Order No. # Date 13 October, Name of Place California.

Off-grid Power for Wireless Networks. Training materials for wireless trainers

Applied Materials is accelerating Solar

Why array oversizing makes financial sense

ESTECO DESIGN COMPETITION 2018 RULES AND REGULATIONS

Considerations for Municipal Solar Projects. Ben Frevert Larsen Engineers November 16, 2016

CPV Industry Overview

Competitiveness & Economics


Microgrid Technology. Paul Newman Microgrid Sales Manager North America - West

RE10 tenksolar System Overview

HIT Photovoltaic Panels

Figure 1b: Daily Production Profile Non Power Limiting Day

Master Class on PVsyst Solar Project Designing Tool 7 th June 2013

U.S. Photovoltaic Roadmap Perspective from a Manufacturing Industry. Subhendu Guha United Solar Ovonic

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA

Solar Photovoltaic (PV) Design Considerations & Issues. By Paul M. Williams, President & CEO

Future Trends & Creative Approaches

A Battery Equivalent Model for DER Services

June 13, Dear Mr. Klauss,

X-SERIES SOLAR PANELS

SOLON Power Purchase Agreements

Wind-Solar Hybrid Power Generation Systems. Energy Pvt. Ltd.

OPEL Solar (TSXV: OPL) April, 2011

ALZ Electrical Solar Consumer Guide

Solar Electric Modules

Performance of Batteries in Grid Connected Energy Storage Systems. June 2018

SOLAR ELECTRIC INVESTMENT ANALYSIS

ESCI 61- PV Cells Modules and Arrays April 21- Week 3 Agenda

Airports Going SOLAR! Michael Shonka

November 2016 SOLIBRO GMBH COMPANY PRESENTATION RENEWABLE ENERGY DELEGATION FROM GERMANY. M.Sc.-Ing. Mostafa Kamal


SOLAR PV CAROUSEL TRACKERS FOR BUILDING FLAT ROOFTOPS: THREE CASE STUDIES

APPENDIX XIII PROJECT SPECIFICATIONS AND CONTRACT CAPACITY CALCULATION I. PROJECT SPECIFICATIONS

Hantile Product Manual

Does Community Solar Have a Future in New England?

APPENDIX XIII PROJECT SPECIFICATIONS AND CONTRACT CAPACITY CALCULATION I. PROJECT SPECIFICATIONS

Rooftops requiring a building integrated solar solution with no roof penetrations

SOLAR ENERGY ASSESSMENT REPORT. For 115 kwp. Meteorological Data Source Meteonorm. Date 18 October, Name of Place California.

OPTIMIZING COMMERCIAL SOLAR

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)


HONORABLE CHAIRPERSON AND MEMBERS OF THE AZUSA UTILITY BOARD

Solar Power. Demonstration Site. Annual Performance Report 2017

The Solar Zone at the UA Tech Park Phase II Expansion

Interconnection System Impact Study Report Request # GI

Net Meter and Production Meter installed by Xcel Energy

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under TR/KABITA Program

Phönix SonnenStrom AG

4 submersible pumps powered by renewable energy sources

Southeast Asia: A Bright Future for Solar

Passenger Rail Solar Electrification: A Primer. Oregon Department of Transportation Rail Division. June 2009

A Review on Grid Connected 100 kw Roof Top Solar Plant

More Energy. For Life. Maximise your energy production with SunPower.

Contents. Solar Select TM Frequently Asked Questions

E-SERIES RESIDENTIAL SOLAR PANELS

Sell Solar TODAY with Solar in a Box

Introduction to Solar PV. Basics

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under Ownership Model

SUBSIDY SCHEME FOR GRID CONNCTED SOLAR ROOFTOP POJECT IN ASSAM UNDER THE 14 MW RESCO AND CAPEX MODEL

4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH

For the highest caliber solar system choose Rosendin Electric s exceptional collaborative team

This presentation is based on information currently available to management. The forward-looking statements contained herein could be substantially

Montana State University: Solar Cells Lecture 9: PV Systems. Montana State University: Solar Cells Lecture 9: PV Systems

OVERSIZING WHITEPAPER

METHODOLOGY FOR ESTIMATING ROOFTOP SOLAR FEASIBILITY ON AN URBAN SCALE

All of Texas Has Excellent Solar Resources. United States Solar Installed (as of mid 2013): 10 GW Germany Solar Installed (end of 2013): 35.

Stationary Energy Storage Solutions 3. Stationary Energy Storage Solutions

TECHNOLOGY, RESOURCES, AND POLICIES

Q-CELLS CIGS THIN FILM MODULES: HIGHEST EFFICIENCY IN THE MARKET

Market Drivers for Battery Storage

Energy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX (46) Sharp 208 W Modules = 9.

Key Points on Design of Commercial Scale Distributed Photovoltaic System Produced by: Rodd Zhang and Carl Patrick. Presenter: Rodd Zhang

Community Solar Projects: Glossary of Terms

Capture The Power of Photovoltaics. IEEE Power Engineering Society Meeting May 2005

Designing Stand Alone Systems. Overview, components and function, Elements in Design

Technical data Cells qty/size 60/156 mm Power output tolerance Temperature NOCT

To Shift or not to Shift?

EPUB // WHAT IS A SOLAR CELL ARCHIVE

UM1716 Resource Value of Solar Docket Due: December 22, 2015

Impact of Reflectors on Solar Energy Systems

International Aluminium Institute

electrical data depending on insolation * 10 mw / cm² 100 mw / cm² open-circuit voltage 4,1 V 4,9 V voltage at nominal power Uoc

ILF Consulting Engineers

Productive. Reliable. Smart. Safe. Brandon J. Pierquet. The Impact of Microinverters in Photovoltaic Systems Enphase Energy

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

3 MWp vertical E-W oriented system in Germany. Dipl. Ing. Heiko Hildebrandt

Example 1MW Solar System for Fosters Yatala

Community solar bulk purchase program for the residents of Dunwoody

Grasshopper Vision. Accelerate the adoption of sustainable practices by creating accessible and affordable products for everyone.

Solar Plus: A Holistic Approach to Distributed Solar PV Eric O'Shaughnessy, Kristen Ardani, Dylan Cutler, Robert Margolis

Transcription:

Final Report Competitive Analysis: Levelized Cost of Electricity (LCOE) Rev C: January 24, 2008 IBIS Associates, Inc. 1601 Trapelo Road, Suite 164 Waltham MA 02451 USA voice: 781-290-5387 fax: 781-290-0454 email: alan@ibisassociates.com web: http://ibisassociates.com

Table of Contents Table of Contents... 1 Introduction... 3 System Descriptions... 4 Figure 1 XsunX, Inc. Solar PV Cell Schematic... 4 Table 1 Temperature coefficients by technology... 5 Table 2 Suitability for rooftop installations (product power densities)... 6 Table 3 Cell Performance Characteristics... 6 Figure 2 Module Price as a Function of Purchase Volume... 7 Table 4 System Derate Factors: Model Assumptions (Input Variables)... 8 Figure 3 Land Usage Requirements: Portland, OR... 9 Figure 4 Land Usage Requirements: Phoenix, AZ... 10 Table 5 Relative System Sizes: Phoenix, AZ... 10 Table 6 Relative System Sizes: Portland, OR... 11 Results and Analysis... 12 Figure 5 Annual Output: 1MW, Phoenix, AZ (fixed axis)... 12 Figure 6 - Annual Output: 1MW, Phoenix, AZ (1-axis)... 13 Figure 7 - LCOE: 1MW Phoenix, AZ (fixed axis), $3.20/W XsunX module price... 14 Figure 8 - LCOE: 1MW Phoenix, AZ (1-axis tracking), $3.20/W XsunX module price... 15 Figure 9 LCOE Sensitivity: XsunX module price, 1 MW Phoenix, AZ (fixed axis)... 16 Figure 10 - Annual Output: 1MW, Portland, OR (fixed axis)... 17 Figure 11 - Annual Output: 1MW, Portland, OR (1-axis)... 18 IBIS Associates, Inc. Page 1

Figure 12 LCOE: 1MW Portland, OR (fixed axis), $3.20/W XsunX module price... 19 Figure 13 LCOE: 1MW Portland, OR (1-axis), $3.20/W XsunX module price 20 Figure 14 LCOE Sensitivity: XsunX module price, 1 MW Phoenix, AZ (fixed axis)... 21 Appendix: Interview Notes... 22 IBIS Associates, Inc. Page 2

Introduction The Levelized Cost of Electricity (LCOE) is the principle metric by which electricity generation technologies are compared. This established basis for evaluating the cost of a generation method takes into account those aspects of a technologies performance that directly impact power generation efficiency, system cost, and reliability. LCOE is a measure of the total lifecycle costs associated with a PV system divided by the expected lifetime-energy output, while accounting for the appropriate adjustments such as time value of money, etc. The National Renewable Energy Laboratory (NREL) has developed a robust model that considers the climatic variables which impact solar energy generation for hundreds of US locations called: the Solar Advisor Model (SAM). As a participant in the Solar America Initiative, IBIS Associates is expert in the use of the SAM software. In addition, IBIS has supported numerous government proposals by small and large PV Companies by providing the requisite LCOE benchmarking analyses. Scope As a manufacturer of a novel thin film Photovoltaic (PV) cell and module technology, XsunX requires a detailed, unbiased analysis of their competitive LCOE position relative to incumbent PV-technologies and immediate competing products. Five (5) key competing PV products have been chosen as the scope of this analysis; representing a diverse range of available and leading field-installation PV products. a-si triple junction (e.g. ECD) mc-si (Schott) CIGs (Global Solar) CdTe (First Solar) X-Si (Sharp) The technologies were chosen based on their prominence in the market (i.e. X-Si) and unique performance characteristics that make them uniquely competitive in the markets that XsunX intends to target (i.e. low light areas a-si triple junction). The scope of the analysis was further constrained to two (2) US locations that provide bases for evaluating the products in extreme temperature and irradiance conditions. Phoenix, AZ Portland, OR The locations were also selected based on the availability of climate and environmental data (i.e. solar radiance, cloud coverage, temperature, etc.). IBIS Associates, Inc. Page 3

System Descriptions Levelized Cost of Electricity (LCOE) analyses are calculated based on simulations of products and systems designs in specific locations. The module technologies under consideration may be configured in a wide range of stationary, tracking, rooftop or field installations. The choice of system design drives the Balance of System (BoS) requirements, land usage, maintenance and installation costs and performance (tracking). The choice of system design was chosen as the choice of locations for the analyses were chosen; to profile the market segments for which XsunX s cell technology is best suited. Cell Performance Cell performance characteristics were collected from product specification sheets, academic literature, and NREL (testing) publications. XsunX XsunX, Inc. has developed a novel thin film solar Photovoltaic (PV) cell technology comprised of amorphous silicon layers. Figure 1 XsunX, Inc. Solar PV Cell Schematic Due to its novel material structure, the technology has several key performance attributes that make it cost competitive in low light and high temperature conditions. Early morning and late afternoon solar irradiance generally provides light consists of a shorter wavelength. Based on the photo-absorbent material components in each cell, performance during early and late day time periods will vary. It has been found that the IBIS Associates, Inc. Page 4

improved low light performance of amorphous silicon, which is contained in both the a- Si Triple Junction product and the XsunX cell improves overall cell output by approximately 20% 1. Although amorphous silicon solar cells suffer from lower conversion efficiency under Standard Test Conditions (STC), it has been found that the performance of this type of solar photovoltaic cell technology is outstanding in low light (diffuse) conditions. As a result, under non-ideal conditions amorphous silicon solar cells can outperform crystalline cell products. Non-ideal conditions, for which amorphous silicon cells are particularly well suited, include non-ideal orientations and low light conditions. The Pacific Northwest, Portland, Oregon for instance is typically not thought to be an area where solar photovoltaics are viable. The amount of cloud cover (diffuse light) is on average, quite high. However, every location, no matter how well suited they appear for solar electricity generation, suffers some losses early in the morning and late in the afternoon. Temp Coefficient Product / C Source mc-si -0.47% Schott litterature (a-si) Triple Junct -0.31% NREL CIGS -0.60% Shell litterature CdTe -0.20% First Solar litterature X-Si -0.47% Schott litterature XSunX 0.00% Sanyo brochure (a-si) Table 1 Temperature coefficients by technology The power density (DC peak) of the product is approximately 78.75 W DC peak / m 2 (fourth highest among the six products investigated in this analysis). 1 Triple Junction Thin Film Silicon Solar Cells compared to Crystalline Silicon Solar Cells under Real Outdoor Conditions in Western Europe, Cleef et al, Bekaert ECD Solar Systems Europe N.V.- BESS EUROPE, Zulte, Belgium, 2001 IBIS Associates, Inc. Page 5

Suitability for Power Density area constrained Product W DC peak / m 2 Applications X-Si 133.00 High mc-si 123.60 CIGS 81.46 XSunX 75.84 CdTe 72.39 (a-si) Triple Junct 60.09 Low Table 2 Suitability for rooftop installations (product power densities) System Type: Field Installation The relatively low XsunX cell power density however makes that product most suitable for installations where space is not limited (i.e. non-rooftop or field installation applications). While rooftop applications are a key market that XsunX, Inc. is targeting, especially in niche markets, such as low light and high heat climates, field installations are most likely to make up the majority of the XsunX s early adopters. Competing Modules: Cell Performance The performance characteristics of the competing cell and module technologies was collected from first hand (i.e. manufacturers, solar integrators), as well as through public literature. UniSolar Schott (a-si) Triple GSE First Solar Sharp XSunX Performance Characteristics mc-si Junction CIGS CdTe X-Si a-si Short Circuit Current (Isc) A 6.5 5.1 4.1 1.066 8.35 1.5 Open Circuit Voltage (Voc) V 60 46.2 52 79.58 36.3 58 Maximum Power Point Current (Impp) A 5.9 4.1 3.24 0.918 7.53 1.27 Maximum Power Point Voltage (Vmpp) V 51 33 37 56.78 28.71 100 Inverter power rating Wdc/inverter 333,000 333,000 333,000 333,000 333,000 333,000 Module efficiency % 12.36% 6.26% 8.16% 7.24% 12.60% 7.90% System degradation % / year 0.25% 0.25% 0.25% 0.25% 0.25% 0.25% Module lifetime years 20 20 20 20 25 20 Table 3 Cell Performance Characteristics In the case of system degradation, reliable data was not readily available for all products. As a result, a constant was chosen for all module technologies. This represents an area where greater resolution is likely to become available as longitudinal data becomes available from aging installations (experience). IBIS Associates, Inc. Page 6

System size The baseline system size considered was chosen to represent a large (e.g. power purchase or utility) installation; 1MW (AC peak power/year). Module Price: Volume Discounts In addition to directly impacting the investment requirements for items such as BoS components, racks, and installation labor, system size also directly impacts module price. Discounts to retail module prices are often offered to customers making large purchases. Module Price ($ / W DC peak ) $5.5 $5.0 $4.5 $4.0 $3.5 Module Price as a Function of Purchase Volume Compiled from quoted prices at volume and retail pricing information Discounting rate backwardscast based on collected UniSolar and Sharp prices -high (1MW) and low (retail) volumes, and each products' quoted 1MW price. See accompanying Interview Notes.doc Schott UniSolar GSE First Solar Sharp $3.0 10,000 100,000 1,000,000 Purchase volume (W DC peak ) Figure 2 Module Price as a Function of Purchase Volume High volume module prices were collected for each technology of interest. In case of two of the five products multiple data points were collected describing the volume price discount available. These relationships were used to back-cast the lower volume purchase price for the remaining three products, based on the discount rate and known high volume (1MW DC peak ) purchase price for each. Installation Land Requirements Whether the non-rooftop field installation is being installed for a utility or commercial Power Purchase Agreement (PPA), the end user is most likely to determine the system size based on power generation (AC Watts). Differences exist among the technologies IBIS Associates, Inc. Page 7

of interest, in terms of the power density (W DC peak / m 2 ) they provide. In addition, the performance of each module also varies. General system derate factors were held constant for the purposes of this analysis. Soiling, AC and DC wiring, module mismatch, and diode losses have been held constant. Inverter conversion efficiency was also held constant for each module. Derate Factor Assumption PV module nameplate DC rating 95% Total DC/AC inverter efficiency 94.50% Mismatch 98% Diodes and connections 96.0% DC wiring 97.5% AC wiring 97.5% Soiling 100% System availabilty 100% Shading 100% Sun-tracking 100% Age 100% Table 4 System Derate Factors: Model Assumptions (Input Variables) Additionally, the temperature coefficients (see Table 1 in the above section) and climate variables (hours and intensity of solar irradiance) contribute to the amount of power provided by each module technology. The number of modules required to achieve the minimum AC power output given each system s derate and conversion performance factors was calculated for each module technology. The baseline analysis was conducted around a 1 MW fixed field installation. The tilt was calculated to be equivalent with that of the location s latitude, in order to maximize the performance during the entire year. Land usage is calculated based on the number of modules required to provide the minimum power requirement, footprint of each module, and minimum spacing to accommodate the maximum shadowing affect between each row, given the tilt angle. Portland, Oregon is at latitude 45.5 degrees North. IBIS Associates, Inc. Page 8

System Land Requirements Portland, OR 1MW DC Peak Station Installation (include shadowing affect) 10 8 SCHOTT UniSolar Land (Acres) 6 4 2 0-200,000 400,000 600,000 800,000 1,000,000 System Size (W DC peak ) GSE First Solar Sharp XSunX Figure 3 Land Usage Requirements: Portland, OR IBIS Associates, Inc. Page 9

Phoenix, Arizona is at latitude 35.5 degrees North. System Land Requirements Phoenix, AZ 1MW DC Peak Station Installation (include shadowing affect) 10 8 SCHOTT UniSolar Land (Acres) 6 4 2 0-200,000 400,000 600,000 800,000 1,000,000 System Size (W DC peak ) GSE First Solar Sharp XSunX Figure 4 Land Usage Requirements: Phoenix, AZ The difference in available solar resources between the locations of interest; Portland, Oregon and Phoenix, Arizona, as well as the module performance differences in these conditions, and latitude (tilt) of the cells account for the difference in land requirements between the regional installations. Balance of System Costs The Balance of System costs associated with each module s installation design is directly related to the size of the installation; number of modules and module size (land requirements, and weight). Relative System Size - Phoenix, AZ (1MW AC ) Schott UniSolar GSE First Solar Sharp XSunX Area 1.00 1.65 1.52 1.71 0.93 1.30 # modules 1.0 1.85 2.50 5.75 1.38 1.98 Table 5 Relative System Sizes: Phoenix, AZ IBIS Associates, Inc. Page 10

Relative System Size - Portland, OR (1MW AC) Schott UniSolar GSE First Solar Sharp XSunX Area 1.00 1.65 1.52 1.71 0.93 1.30 # modules 1.0 1.85 2.50 5.75 1.38 1.98 Table 6 Relative System Sizes: Portland, OR The cost of balance of system components was estimated by a number of solar integrators and module providers (see Appendix: Interview Notes). This data was supplemented with academic publications and information from the public domain 2. The model has the capacity to predict the balance of system costs based on the installation size. The amount (cost) of long wiring and conduit scales as the land requirements scale. The cost of cable housing, fuse boxes, connectors and connection wiring (between modules) scales with the number of modules that are required to achieve the predetermined annual power output. Inverters Inverter costs, lifetime, and size were chosen based on conversations with solar integrators who have experience installing 1MW field systems. Advanced Energy Industries: 333kW inverter, 94.5% efficiency Monitoring and Data Acquisition: $4500 per inverter The costs parameters and product performance was held constant across all module technologies. 2 Photovoltaic Power Plant Experience at Tucson Electric Power, Moore et al, IBIS Associates, Inc. Page 11

Results and Analysis Phoenix, AZ 3,000 Annual Output before Derate (Phoenix, AZ) Equivalent degradation factors, stationary tracking mc-si Output (MW-h / year) 2,750 2,500 2,250 2,000 1,750 (a-si) Triple Junction CIGS CdTe X-Si XSunX 1,500 0 5 10 15 20 25 30 Year Figure 5 Annual Output: 1MW, Phoenix, AZ (fixed axis) IBIS Associates, Inc. Page 12

3,000 Annual Output before Derate (Phoenix, AZ) Equivalent degradation factors, 1-axis tracking mc-si Output (MW-h / year) 2,750 2,500 2,250 2,000 1,750 (a-si) Triple Junction CIGS CdTe X-Si XSunX 1,500 0 5 10 15 20 25 30 Year Figure 6 - Annual Output: 1MW, Phoenix, AZ (1-axis) IBIS Associates, Inc. Page 13

45 40 35 LCOE Analysis (Year 1) 1MW stationary field installation, Phoenix, AZ XSunX module price = $3.20/W DC Peak Variable O and M Fixed O and M Sales Tax Cost (cents / kw-hr) 30 25 20 15 10 5 0 Schott UniSolar GSE First Solar Sharp XSunX Project, Land, Miscellaneous Engineer, Procurement, Construct Contingency Cost Installation BOS Inverter Module Figure 7 - LCOE: 1MW Phoenix, AZ (fixed axis), $3.20/W XsunX module price IBIS Associates, Inc. Page 14

45 40 35 LCOE Analysis (Year 1) 1MW 1-axis tracking field installation, Phoenix, AZ XSunX module price = $3.20/W DC Peak Variable O and M Fixed O and M Sales Tax Cost (cents / kw-hr) 30 25 20 15 10 5 0 Schott UniSolar GSE First Solar Sharp XSunX Project, Land, Miscellaneous Engineer, Procurement, Construct Contingency Cost Installation BOS Inverter Module Figure 8 - LCOE: 1MW Phoenix, AZ (1-axis tracking), $3.20/W XsunX module price IBIS Associates, Inc. Page 15

60 50 LCOE Sensitivity Analysis (Year 1) 1MW stationary field installation, Phoenix, AZ XSunX mc-si LCOE (cents / kw-h) 40 30 20 10 (a-si) Triple Junct CIGS CdTe X-Si 0 0 1 2 3 4 5 6 7 8 XSunX Module Cost ($/W peak dc) Figure 9 LCOE Sensitivity: XsunX module price, 1 MW Phoenix, AZ (fixed axis) IBIS Associates, Inc. Page 16

Portland, OR 2,000 Annual Output before Derate (Portland, OR) Equivalent degradation factors, stationary tracking mc-si Output (MW-h / year) 1,800 1,600 1,400 1,200 (a-si) Triple Junct CIGS CdTe X-Si XSunX 1,000 0 5 10 15 20 25 30 Year Figure 10 - Annual Output: 1MW, Portland, OR (fixed axis) IBIS Associates, Inc. Page 17

2,000 Annual Output before Derate (Portland, OR) Equivalent degradation factors, 1-axis tracking mc-si Output (MW-h / year) 1,800 1,600 1,400 1,200 (a-si) Triple Junct CIGS CdTe X-Si XSunX 1,000 0 5 10 15 20 25 30 Year Figure 11 - Annual Output: 1MW, Portland, OR (1-axis) IBIS Associates, Inc. Page 18

Cost (cents / kw-hr) 60 50 40 30 20 10 LCOE Analysis (Year 1) 1MW stationary field installation, Portland, OR XSunX module price = $3.20/W DC Peak Variable O and M Fixed O and M Sales Tax Project, Land, Miscellaneous Engineer, Procurement, Construct Contingency Cost Installation BOS Inverter 0 mc-si (a-si) Triple Junct CIGS CdTe X-Si XSunX Module Figure 12 LCOE: 1MW Portland, OR (fixed axis), $3.20/W XsunX module price IBIS Associates, Inc. Page 19

Cost (cents / kw-hr) 60 50 40 30 20 10 LCOE Analysis (Year 1) 1MW 1-axis tracking field installation, Portland, OR XSunX module price = $3.20/W DC Peak Variable O and M Fixed O and M Sales Tax Project, Land, Miscellaneous Engineer, Procurement, Construct Contingency Cost Installation BOS Inverter 0 mc-si (a-si) Triple Junct CIGS CdTe X-Si XSunX Module Figure 13 LCOE: 1MW Portland, OR (1-axis), $3.20/W XsunX module price IBIS Associates, Inc. Page 20

LCOE (cents / kw-h) 100 90 80 70 60 50 40 30 20 10 0 LCOE Sensitivity Analysis 1MW stationary field installation, Portland, OR 0 1 2 3 4 5 6 7 8 XSunX Module Cost ($/W peak dc) XSunX Schott UniSolar GSE First Solar Sharp Figure 14 LCOE Sensitivity: XsunX module price, 1 MW Phoenix, AZ (fixed axis) IBIS Associates, Inc. Page 21

Appendix: Interview Notes Note: The following interview notes contain sensitive information and are not suited for broad redistribution. While the respondents spoke with IBIS knowing that their remarks might be passed on to the client, they were not given the opportunity to review these written notes and might find them, and their interpretation by IBIS, objectionable. In response to the Ibis request above, XsunX has removed the interview data. IBIS Associates, Inc. Page 22