Installation Instructions

Similar documents
INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Installation Instructions

Owner s Information Manual

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Supplemental Installation Instructions -- August 2016

Installation Instructions

Installation Instructions

INSTALLATION& OWNER S MANUAL

Electrical Data Supplement

Installation Instructions

Electrical Data Supplement

Electrical Data Supplement

Installation Instructions

Installation Instructions

Installation Instructions

Supplemental Installation Instructions -- August 2016

Installation Instructions

Installation Instructions

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Installation Instructions

Installation Instructions

Electrical Data Supplement

Installation Instructions

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

Installation Instructions

Installation Instructions

Installation and Start Up Instructions

Installation Instructions

Installation Instructions

Installation and Start-Up Instructions

IMPORTANT SAFETY NOTICE

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Installation Instructions

TECHNICAL SUPPORT MANUAL Coils for Manufactured Housing EMA2X, EMA4X

Installation Instructions

INSTALLATION INSTRUCTIONS

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

INSTALLATION MANUAL TBH/TBV BELT DRIVE BLOWER-COIL UNITS HORIZONTAL. Redefine your comfort zone.

Combined Ventilation Controller RVWS-T-224HA

Electric Vehicle Charging Station

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

VANGUARD Series 36" Slant Wall and Cone Direct Drive Fans Installation & Operator s Instruction Manual

IMPORTANT ATTENTION INSTALLERS:

TECHNICAL SUPPORT MANUAL Split System Heat Pump H2H3, 3 Phase

Air Lift. Kit Ford Mustang SN95 PERFORMANCE INSTALLATION GUIDE. Rear Application

TECHNICAL SUPPORT MANUAL Split System Air Conditioner H4A3, 3 Phase

TECHNICAL SUPPORT MANUAL WT A Coils for Replacement Service EXA, EPA

TECHNICAL SUPPORT MANUAL Fan Coils FSM4X6000AT

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

Installation Instructions

Hose Reel Kit for Multi-Pro 1200 and 1250 Sprayers. Installation Instructions. Form No Model No Serial No.

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

Technical Manual. DLM Module. This manual should remain with the unit.

INSTALLATION INSTRUCTIONS

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use

보조전원모듈 _MCM-C210_IM_EN_03929A(2).indd 오후 12:29:00

Applies to: Models F, B, FE, and BE with spark pilot

SeekTech Inductive Clamp

Switching DC Power Supply

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2

Installation Instructions

TECHNICAL SUPPORT MANUAL Split System Heat Pump N2H3**C (Coastal)

INSTALLATION INSTRUCTIONS

Installation manual wall-mounted distributor

SERVICE INSTRUCTIONS

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

T832 T842 ELECTRIC MOTOR OPTION ASSEMBLY MANUAL. Read & understand all instructions pertaining to this option prior to use!

CAUTION. Disconnect Power

Operations and Service Manual. X30208 Load Bank

Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications.

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A3, 3-Phase

OPE R AT O R S MANU A L QUICK-HITCH ADAPTER. 5BP (Field conversion kit)

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A0, 3-Phase

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Installation, Start-Up and Service Instructions

Parts missing or damaged? Questions? Toll-free Helpline

Installation Manual. Low Ambient Cooling Kit. ZLABKA01A Low Ambient Cooling Kit. ZLABKA02A Low Ambient Cooling Kit

Installation Instructions

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

Installation Manual. Remote Temperature Sensor KS9-BS1-A. Instructions for :- Remote Temperature Sensor

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

Installation Instructions For Motor Control Center (MCC) Units

AHKD SERIES ELECTRIC RESISTANCE HEAT KITS INSTALLATION & OPERATING INSTRUCTIONS

Owner's/Installation Manual

Antifreeze Type SYC1025 (Long life coolant) Mixing ratio (water:antifreeze) Cooling fan module Type Electric Capacity

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A3

YCCS TE-6800 Series Temperature Sensors

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

Transcription:

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems Installation Instructions NOTES: Read the entire instruction manual before starting the installation.

TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 COMPATIBILITY... 4 INSTALLATION... 5 PART LIST... 6 DIMENSIONS... 7 CONNECTION DIAGRAM... 7 INSTALLATION... 8 CONSTANT AIR VOLUME TESTING... 15 SAFETY CONSIDERATIONS Read these instructions thoroughly and follow all warnings or cautions included in the literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements. Recognize safety information. This is the safety alert symbol!!. When you see this symbol on the unit and in instructions or manuals, pay attention to the potential for personal injury. Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the safety alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. 2

! WARNING INSTALLATION Entrust the distributor or authorized professionals to install the unit. Installation by unskilled persons may lead to improper installation, electric shock, or fire. Re installation must be performed by authorized professionals. Non compliance may lead to electric shock or fire.! CAUTION EQUIPMENT DAMAGE HAZARD Failure to follow this warning may result in equipment damage. Do not install the wired controller in an area subjected to excessive steam, oil, or sulfide gas. Doing so may cause the controller to deform and/or fail.! WARNING ELECTRONIC SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before beginning any kit modification or installation, ensure the main electrical disconnect is in the OFF position. Ensure power is disconnected to the fan coil unit. Some systems may have both the fan coil and the outdoor unit on the same disconnect. Tag the disconnect switch with a suitable warning label. There may be more than one disconnect. 3

COMPATIBILITY High Wall Cassette Ducted Console Table 1 Compatibility Model Number 40MAQ 619P*B DLFSHA 40MBQB*C 619R*C 40MBCQ DLFSCA DLFLCA 40MBQB*D 619R*D 40MBDQ DLFSDA DLFLDA 40MBQB*F 619R*F 40MBFQ DLFSFA DLFLFA Wired Controller Part Number KSACN0101AAA NOTES: The wildcard character (*) represents one or more characters 4

INSTALLATION Installation precautions for the wired remote controller: Do not install in a location near heavy oil, vapor or sulfurated gas otherwise this product will deform which will lead to a system malfunction. Do not install the unit in a location near flammable gas leaks. Once flammable gases leak and are left near the wired controller, a fire may occur. Do not operate with wet hands. Do not allow water to enter the wired controller otherwise an electric shock may occur. The wiring should conform to the wired controller current otherwise electric leakage or heating may occur which may result in fire. Use the correct cables for wiring. No external force may be applied to the terminal otherwise wire cuts and heating may occur and result in a fire. This manual contains the installation method for the wired controller. Refer to the wiring diagram in this manual to connect the wired controller to the indoor unit. The wired controller operates in a low voltage loop circuit. Do not connect the 208 230V power directly to the thermostat. Do not wire this type of wire in the same loop. The wiring clearance between the configured tubes should maintain a range of 12 20 inches (305 508mm) or more. The wired controller shielded wire must be well grounded. The wired controller connective cable should not be longer than 66 feet (20 meters). This manual provides a detailed description of the precautions that should be taken during operation. To ensure correct service of the wired controller, read this manual carefully before using the unit. After reading this manual thoroughly, keep it for future reference. 5

PARTS LIST Kit Contents: Confirm that all the following parts are included. Table 2 Supplied Parts No. DESCRIPTION Qty. REMARKS 1 Wired Remote Controller 1 n/a 2 Installation and owner's manual 1 n/a 3 Screws 3 M4X20 (for mounting on the wall) 4 Wall plugs 3 For wall mounting 5 Screws 2 M4X25 (for mounting on the wall) 6 Plastic screw bars 2 For fixing on the switch box 7 The connective wires group 1 24AWG NOTES: Extension wire available through RCD (Replacement Components). Part Number: 17401204001601. Field Supplied Components: Prepare the following on site. Table 3 Field Supplied Components DESCRIPTION Qty. TYPE REMARKS Switch Box 1 n/a n/a Wiring Tube (insulating sleeve and tightening screw) 1 n/a n/a 6

Wire Controller DIMENSIONS 4.7 (120mm) 0.8 (21mm) 0.5 (13.1mm) 4.7 (120mm) 2 (51.1mm) 0.7 (19.5mm) 19.5 mm 3.3 (85.5mm) Fig. 1 - Dimensions CONNECTION DIAGRAM Wire Joint, 5p 1.9 (50mm) Infrared Pipe +5V 5-Core Shield Cable RUN GND Indoor Unit Switch Board 7 Indoor Unit Fig. 2 - Connection Diagram

INSTALLATION 1. Remove the upper part of the wired controller. Insert a screwdriver into the two slots of the lower part of the wired controller, and remove the upper part of the wired controller.! Slots Fig. 3 - Slots WARNING The Printed Circuit Board (PCB) is mounted in the upper part of the wired controller. Be careful not to damage the board with the slot screwdriver. 8

2. Mount the back plate of the wired controller. a. For exposed mounting, fasten the back plate on the wall with 3 screws (M4x20) and plugs. Back plate Screws (M4 20) Fig. 4 - Back plate 9

b. For flush mounting, fasten the back plate of the switch box with 2 screws (M4x25) and then fasten it to the wall with 1 screw (M4x20). Switch box Back plate Screw (M4 20) Screws (M4 25) Switch box Fig. 5 - Switch box NOTES: Place on a flat surface. Be careful not to distort the back plate of the wired controller by over tightening the mounting screws. 10

3. Wiring routing Top side wire outlet Left side wire outlet Right side wire outlet Bottom side wire outlet Fig. 6 - Wire outlets a. For exposed mounting there are four outlet positions and three require cutting. Cut one hole for wire outlet Fig. 7 - Wire outlets 11

b. For shielded wiring, see Figure 8. Embedded switch box wiring Wiring through the wall Wiring hole Wall hole and wiring hole Diameter of wall hole: 2cm Fig. 8 - Shielded Wiring NOTES: DO NOT allow water to enter the remote control. Use the trap and putty to seal the wires. Putty Trap Putty Putty Trap Trap Fig. 9 - Putty and Trap NOTES: To keep water from entering the wired remote controller, use a trap and putty to seal the wired connectors during the wiring installation. During installation, reserve a certain length of the connecting wire to make removing the wired remote controller easier during maintenance. 12

4. Wire Connection Connect the wire from the indoor unit s display panel to a connecting cable. Next, connect the other side of the connecting cable to the remote control. The connective wires group 5-core wire Front grille NOTES: shielded wire (some units) Fig. 10 - Wire Connection Be sure to reserve a length of the connecting wire for periodic maintenance. If there is a connection lug at the end of shielded wire, the connection lug should be properly grounded. Figure 10 is for reference on the wire connection. Consult the indoor unit manual for specifics on the connection. 13

Set the Time and Date The remote control has a small, built in battery that allows the time and date to be set. That way the remote control can keep time even during a power outage. When the unit displays an incorrect time and date the batteries need to be replaced. 1. Re attach the upper part of the wired controller. 2. After adjusting the upper case, buckle the upper case. Avoid clamping the wiring during installation. Fig. 11 - Set the Time and Date NOTES: The images in this manual are for illustration purposes only. Your wired controller may differ slightly. 14

CONSTANT AIR VOLUME TESTING To set External Static Pressure (some ducted unit models) The user can use the unit s automatic airflow adjustment function to set the external static pressure. Automatic airflow adjustment is the volume of blow off air that has been automatically adjusted to the quantity rated. 1. Ensure the test run is done with a dry coil. If the coil is not dry, run the unit for 2 hours in FAN ONLY mode to dry the coil. 2. Check that both the power supply wiring and the duct installation have been completed. Ensure all closing dampers are open. Check that the air filter is properly attached to the air suction side passage of the unit. 15

3. Set the parameters for automatic airflow adjustment. When the air conditioning unit is off, perform the following steps: (1.) When the unit is turned on, hold MODE and FAN down together for three seconds. (the AF indicator flashes 3 times). (2.) Press or to select the AF. (3.) Press MODE. The air conditioning unit will then start the fan for airflow automatic adjustment. After 6 minutes, the air conditioning unit stops operating once the automatic airflow adjustment is complete. TIME ON FOLLOW ME ECO TIME OFF AUXI L HEATER MOD E FAN SPEED SWING TEMP RESE T LOCK! Fig. 12 - Select the AF settings CAUTION DO NOT adjust the dampers when the automatic airflow adjustment is active. 16

Using the Wire Controller to set Airflow Rate (some ducted unit models) When the air conditioning unit is off, perform the following steps: 1. Press MODE and FAN for three seconds. 2. Press or to select the SP. 3. Press MODE to set the airflow rate in the range of 0~4. TIME ON TIME OFF FOLLOW ME AUXI L HEATER MOD E FAN SPEED ECO SWING TEMP 0 : No airflow change 1 ~ 4 : Airflow increases progressively RESE T LOCK Fig. 13 - Set the Airflow Rate 4. Press ON/OFF to complete the airflow setting. 17

Copyright 2018 CAC/BDP. 7310 W. Morris St. Indianapolis, IN 46231 Edition Date: 02/18 Catalog No: KSACN0101-03SI Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 18 Replaces:KSACN0101-02SI