Inductive Proximity Sensor

Similar documents
Inductive Proximity Sensor

Inductive Proximity Sensor

Cylindrical Proximity Sensor

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in)

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

E2EZ-X2D1-N E2EZ-X2D2-N

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Digital display Pressure range ON/OFF output Linear output Model

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Hinged Safety Door Switch

Switching Power Supply

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

Ordering Information. Application Example. New General-purpose Incremental-type. Rotary Encoder. Accessories (Order Separately)

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Model Pressure range ON/OFF output Linear output

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

H3DS-X - Solid State Two-Wire Timer

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

Surface mounting, flush mounting, and DIN track mounting

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

Analog Input Terminal

Power Controller. (see note 1) 10 sec

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Proximity Sensors E-1. Standard E2E/E2EG E-2 Antispatter E2EQ E-32 Chemical Resistance E2FQ E-40. Cylindrical

Transistor Remote Modules

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Model Pressure range ON/OFF output Linear output

Sensing & Safety GENERAL CATALOGUE 2004/2005

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Inductive Proximity Sensor

DC2-Wire Unshielded Cylindrical Proximity Switches

AC/DC2-wire Type Cylindrical Proximity Switches

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

SA1W: Water Detection Sensors

Compact Inductive Proximity Sensor. onlinecomponents.com. Various Applications

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Operation mode. Sensing distance N.O. N.C. N.O. N.C. N.O. N.C. 7mm

Subminiature Basic Switch

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Analog Output Terminal

Switching Power Supply

Inductive Proximity Sensor

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Differential Pressure Sensor

GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. GX-12ML(B) Conventional model

SYSMAC Transistor Remote Module

E2C/E2C-H. Separate Amplifier Sensor with Sensitivity Adjustment. Separate Amplifier Proximity Sensor with Adjustment Potentiometer

Communications. Auxiliary. Functions. output. functions. Transistor. Heating or cooling control is selectable (See note 2.

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Inductive Proximity Sensor E2Q2. Ordering Information. Limit Switch Style Proximity Sensor with 5-Position Sensing Head

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Model Number Structure

DC2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors N.O. N.C. N.O. N.C. N.O. N.C. 8mm N.O. N.C. N.O. N.O. N.C. N.O. N.O. N.C.

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

Cylindrical Inductive Proximity Sensor GX-M SERIES

Rectangular-shaped Inductive Proximity Sensor.

Model Number Structure

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

sensors SA1C-F High-speed Fiber Optic: SA1C-F

FL7MSeries. DC2-Wire Regular Cylindrical Proximity Sensors

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Tactile Switch (Hinged Type)

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Digital display Pressure range ON/OFF output Linear output Model

ABL Series. Relay Terminal Block (Screwless Type) Features

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Transcription:

Inductive Proximity Sensor Variable Distance and Differential Travel Allow a Wide Range of Applications Various Heads available in outer diametersfrom2.0to40mm. and stability indicators (LED) in Amplifier Unit allow easy monitoring of stable operation. Amplifier Unit has wide-ranging operating voltages, 10 to 30 VDC or 90 to 264 VAC. Small differences in size, distance, and materials can be detected. Ordering Information AC 2-wire Models Size Shield Maxi- Sensor Amplifier Unit distance mum Head Multi-function Single-function Self- operating disdiagnostitance function 2.0 dia. Unshielded (see note1) 0.5 mm 1.2 mm - CR5B 3.5 dia. Shielded 0.8 mm 1.8 mm - CR8A 3.8 dia. 1mm 2mm - CR8B M5 - X1A 5.4 dia. - C1A M8 1.5 mm 3mm - X1R5A M12 2mm 5mm - X2A M18 5mm 10 mm - X5A M30 10 mm 18 mm - X10A 40 dia. Unshielded 20 mm 50 mm - C20MA AC - AK4A DC (PNP, NPN) - AM4A DC (NPN) DC (PNP, NPN) DC (NPN) --- --- - GE4B DC (PNP) - GF4B DC (NPN) --- - JCA4 - WH4AF (see note 2) - WH4A - GE4A - GF4A - JCA4P (see note 3) --- --- --- 1. The -CR5B cannot be flush-mounted in metal even though the -CR5B is of a shielded construction. 2. Use the -WH4AF in combination with the S3D8 Sensor Controller 3. The -JCA4P is an Amplifier Unit with self-diagnostic for DIN track mounting. 1

Specifications Sensor Heads Model -CR5B -CR8A -CR5B Standard sensing Stable sensing range (within rated temperature range) Safety sensing range (0!C to40!c) Maximum operating distance (at 23!C) Response frequency (see note 1) Ambient temperature -X1A -C1A - X1R5A Magnetic metals (Refer to Engineering Data for non-magnetic metals.) Iron:5x5x 1mm 0to0.5mm 0to0.7mm Iron: 5 x 5 x1mm 0to 0.8 mm 0to 1.2 mm Iron: 5 x 5 x1mm 0to1mm 0to 1.5 mm Iron: 8 x 8 x1mm 0to 1.5 mm 0to2mm -X2A -X5A -X10A - C20MA Iron: 12 x 12 x 1 mm Iron: 18 x 18 x 1 mm Iron: 30 x 30 x 1 mm Iron: 50 x 50 x 1 mm 0to2mm 0to5mm 0to10mm 0to20mm 0to 2.5 mm 0to7mm 0to15mm 0to28mm 1.2 mm 1.8 mm 2mm 3mm 5mm 10 mm 18 mm 50 mm 1kHz 800 Hz 350 Hz 100 Hz 50 Hz Operating: -- 10!C to 55!C Ambient humidity Operating: 35% to 95% Temperature influence Vibration resistance Shock resistance "25% max. of the sensing distance at 23!C ina temperature range of --10!C and 55!C Enclosure rating IEC IP64 IEC IP67 Cable length (see note 2) Weight (with 3-m cable) Operating: --25!C to 70!C (with no icing) "15% max. of the sensing distance at 23!C in a temperature range of --25!C and 70!C Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions Malfunction: 500 m/s 2 (approx. 50G) for 3 times each in X, Y, and Z directions 3-m shielded cable Approx. 10 g 3-m high-frequency coaxial cable (5 m max.) Approx. 40 g Approx. 45 g Material Case Stainless steel Brass ABS resin surface Cable Polyethylene Approx. 50 g 3-m high-frequency coaxial cable (10 m max.) Approx. 60 g Approx. 140 g Approx. 270 g Approx. 300 g 1. Response frequencies are minimum values applicable to DC solid-state control used to measure standard sensing s, each separated from one another with a distance that is double the side dimension of the sensing and located at a distance that is half the maximum sensing distance. 2. The cable length varies with the Amplifier Unit and Sensor Head in combination. Refer to the table on the next page. The characteristic impedance of the coaxial cable is 50 #. 2

Cable Lengths vs. Amplifier Unit and Sensor Head Combinations Amplifier Sensor Head Unit - CR5B - CR8A - CR8B -X1A -C1A - X1R5A -X2A -X5A - X10A - C20MA -GE4B 3 m only --- --- --- --- --- --- --- --- --- -GF4B --- --- --- --- --- --- --- --- --- -GE4A --- 3 m only --- --- --- --- -GF4A --- --- --- --- --- -WH4A --- 3 m or 5 m only --- --- --- --- -WH4AF --- Set the pins of the cable length selector properly (see note). --- --- --- --- -JC4AP --- 1 to 3 m: Short-circuit the cable length selector terminals. --- --- --- 3 to 5 m: Open the cable length selector terminals. -JC4A --- 3 m only --- --- --- -AM4A 3mor 0to5m 0to10m 5 m only with all pins of Set the pins of the cable length selector properly (see note). Set the pins of the cable length selector properly (see note). -AK4A the cable length selector set to the left. Refer to page 12 for cable length selection. Amplifier Units Model -AK4A -AM4A -JC4A -JC4AP Power supply voltage (Operating voltage range) 100 to 240 VAC (90 to 264 VAC) 50/60 Hz -GE4j -GF4j -WH4A -WH4AF 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. (see note 1) Current consumption 55 ma max. 50 ma max. 45 ma max. 25 ma max. 25 ma max. distance adjustable range (see note 2) Differential travel Response time Control DC solidstate 20% to 100% of rated sensing distance with a 4-turn potentiometer 20% min. of rated sensing distance 1% to 5% of rated sensing 10% max. of sensing distance distance (see note 3) Refer to the response frequency of the Proximity Sensor in use. Relay 20 ms max. --- DC solidstate 50 ma max. at 40 V with a residual voltage of 2Vmax., transistor photocoupler Relay 2 A at 250 VAC, cos ø = 1 (resistive load) (see note 4), SPDT relay --- Output configuration NO/NC selectable 200 ma max. at 40 V with a residual voltage of 1.5 V max., NPN and PNP open collector 100 ma max. at 40 V with a residual voltage of 0.7 V max. (1 V max. for -JC4AP), NPN open collector 100 ma max. at 40 V with a residual voltage of 1.5 V max., NPN with a resistance of 4.7 k# 100 ma max. at 40 V with a residual voltage of 1.5 V max., PNP with a resistance of 4.7 k# 20% to 100% of rated sensing distance with a 4-turn potentiometer 200 ma max. at 40 V with a residual voltage of 1.5 V max., NPN and PNP open collector s 200 ma max. at 40 V with a residual voltage of 1.5 V max., NPN and PNP open collector Connector : 50 ma max. with a residual voltage of 2Vmax., Transistor photocoupler 3

Model Self-diagnostic -AK4A -AM4A -JC4A -JC4AP --- -JA4AP only. Output transistor turns ON: Sensor wire burnout or unstable detection 50 ma max. at 40 V with a residual voltage of 1 V max., NPN open collector Timer function --- OFF-delay: 40"10 ms Cable length compensation Indicator Ambient temperature Ambient humidity Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Life expectancy Weight Mode selection with a 4-throw switch indicator and stability indicator -JC4AP only. 3m/5mterminals with short bar Short-circuited: 1 to 3m Open: 3 to 5m indicator and stability indicator Operating: --10!C to 55!C (with no icing) -GE4j --- --- -GF4j -WH4A --- 3 m/5 m selectable indicator Operating: 35% to 85% (35% to 95% for the -JC4AP) "10% max. of sensing distance at 23!C in temperature range of --10!C and 55!C -WH4AF DC models: "1% max. of sensing distance in rated voltage range of "20% of the rated power supply voltage AC models: "1% max. of sensing distance in rated voltage range of "10% of the rated power supply voltage 50 M# (at 500 VDC) between current carry parts and case DC models: 1,000 VAC (50/60 Hz) for 1 min between current carry parts and case AC models: 1,500 VAC (50/60 Hz) for 1 min between current carry parts and case Malfunction: 10 to 25 Hz, 2-mm double amplitude for 2hrseachinX,Y,andZ directions Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 2hrseachin X, Y, and Z directions Malfunction: 10 to 25 Hz, 2-mm double amplitude for 2hrseachinX,Y,andZ directions Malfunction: 100 m/s 2 (approx. 10G) for 3 times each in X, Y, and Z directions Mechanical: --- 10,000,000 times min. Electrical: 100,000 times min. Approx. Approx. Approx. 50 g Approx. 20 g 250 g 140 g (-JC4AP: Approx. 80 g) Malfunction: 10 to 25 Hz, 2-mm double amplitude for 2hrseachinX,Y,andZ directions Approx. 80 g 1. A power supply with full-wave rectification with an average of 24 VDC"10% can be used with all Amplifier Units except the -GE4j. 2. The sensing distance adjustable range indicates the sensing range of the Amplifier Unit in satisfactory operation with Sensors. 3. The differential travel is adjustable within a range between 1% and 20% of the rated sensing distance if the -CR5B is used. 4. The built-in Relay is the G2R-114P-V-VS with an operating voltage of 12 V. 5. The weight of each model does not include the weight of the connecting socket. 4

Output Circuits -AK4A (AC-switching Amplifier Unit) -AM4A (DC-switching Amplifier Unit) 50 ma max. 2.2 # Output (+) 12 to 24 VDC Main circuit 47 V Main circuit 200 ma max. 47 V 2.2 # Output 1 (PNP) Output 2 (NPN) Output (--) 47 V Relay contact is incorporated. -GE4j (DC-switching Amplifier Unit) -GF4j (DC-switching Amplifier Unit) 12 to 24 VDC 12 to 24 VDC Main circuit 4.7 k# 100 ma max. 2.2 # Output Main circuit 47 V 4.7 k# 47 V 2.2 # 100 ma max. Output -JC4A (DC-switching Amplifier Unit) -JC4AP Brown (Red) Main circuit 100 ma max. 2.2 # 47 V 12 to 24 VDC Brown (Red) Output Black (White) Blue (Black) indicator (Red) Stability indicator (Green) Main circuit 2.2 # 3.9 # 12 to 24 VDC Black Load (White) 100 ma Output max. Blue (Black) Voltage from -GE4j will be available if the operation selector is set to NC. When using voltage, be sure to reset the -GE4j after the -GE4j is turned on, at which moment the -GE4j generates a pulse for approximately 60 ms. No such pulse is generated from the -GF4 with PNP. Z D :V Z =40 V Orange (Yellow) Self-diagnostic (50 ma max.) -WH4A (DC-switching Amplifier Unit) -WH4AF (DC-switching Amplifier Unit with Connector Output) 12 to 24 VDC 12 to 24 VDC Main circuit 200 ma max. 47 V 2.2 # 2.2 # Output 2 (PNP) Output 1 (NPN) Main circuit 200 ma max. 47 V 2.2 # 2.2 # Output 2 (PNP) Output 1 (NPN) 47 V 47 V 50 ma max. 2.2 # 47 V Connector 5

Operating Charts -Aj4A -Gj4j Mode selector Relay (transistor ) Yes No Reset Mode selector Transistor (voltage ) ON OFF Yes No indicator -JC4A ON OFF indicator -JC4AP ON OFF Mode selector Mode selector Output transistor, terminals short-circuited (OFF-delay enabled) Output transistor, terminals open (OFFdelay disabled) indicator Yes No ON OFF Output transistor Timer switch ON (OFF-delay enabled) Timer switch OFF (OFF-delay disabled) indicator Yes No ON OFF -WH4A(F) Mode selector Yes No Transistor indicator ON OFF Self-diagnostic Function The transistor of self-diagnostic will turn on instantly if the detects one of the following events. 1. Sensor wire burnout 2. The operation indicator is ON for 0.3 s or more while the sensing is at 93% to 100% of the sensing distance. This will occur if the sensing is in the wrong position, for example. 3. The operation indicator is OFF for 0.3 s or more while the sensing located at 100% to 107% of the sensing distance. This will occur if the Sensor is influenced by the background of the sensing, for example. Sensor Wire is Burnt Out Sensor Wire is Connected Control (NO) Yes No distance Set distance Self-diagnostic Indicator Stability Red Red Green Control (NO) Self-diagnostic 0.3 s min. 0.3 s min. Burnout Normal Burnout Normal Indicator Stability Green Red Green Green *Self-diagnostic will be ON if the sensing moves at slow speed, in which case, add an ON-delay timer circuit. Replace the 93% value with 96% and the 107% value with 104% for the -X2A. 6

Indicators $ The operation indicator is lit when the sensing is near the sensing distance. $ The stability indicator is lit when the sensing position is less than 95% or more than 107% of the sensing distance. The stability indicator indicates the range in which each sensing is detected smoothly. Stable nonsensing area indicator (red) Not lit Stability indicator (green) Lit Not lit Set distance x approx. 1.07 (see note) Set distance Stable sensing area Lit Lit Set distance x approx. 0.93 (see note) Replace the 1.07 value with 1.04 and the 0.93 value with 0.96 for the -X2A. Sensitivity Adjustment 1. Initial Adjustment After the Amplifier Unit is turned on, adjust the following Sensor according to the status of each indicator without a sensing. -Gj4j Single-function Model -WH4A(F) Multi-function Model $ Status of $ Adjustment Indicators Lit Not Lit Sensitivity Turn the sensitivity adjuster counterclockwise until the operation indicator turns off. No adjustment is required. -JC4A Multi-function Model -Aj4A Multi-function Model $ Status of Indicators $ Adjustment Indicator mode A B C D Lit Lit NotLit Not Lit Sensitivity Lit Not Lit NotLit Lit Sensitivity Turn the sensitivity adjuster counterclockwise so that the operation indicator turns off and the stability indicator is lit (i.e., the Amplifier Unit is in mode D). No adjustment is required. 2. Sensitivity Adjustment Item -Gj4j Single-function Model -WH4A(F) Multi-function Model Step 1 2 3 1 2 3 Sensitivity adjuster --- --- --- --- Adjustment Obtain the sensing distance Xfromtheset distance S divided by 0.8. Determine S so that X will be less than the maximum sensing distance. Locate the Sensor so that the distance between the Sensor and sensing is X. Turn the sensitivity adjuster clockwise until the operation indicator is lit. Return the Sensor to the previous position so that the distance between the Sensor and sensing is S. Secure the position of the Sensor to complete the sensitivity adjustment. Obtain the sensing distance Xfromtheset distance S divided by 0.8. Determine S so that X will be less than the maximum sensing distance. Locate the Sensor so that the distance between the Sensor and sensing is X. Turn the sensitivity adjuster clockwise until the operation indicator is lit. Return the Sensor to the previous position so that the distance between the Sensor and sensing is S. Secure the position of the Sensor to complete the sensitivity adjustment. If the Amplifier Unit malfunctions due to radical ambient temperature changes, shorten the distance between the Sensor and sensing to 80% maximum of the set distance. 7

Model -Aj4A and -JC4A Multi-function Models (See note 2) Step 1 2 3 4 --- Sensitivity adjuster --- Adjustment Set the MD adjuster to the center between Min and Max. Locate the sensing in the adjustment range of sensing distance and turn the sensitivity adjuster clockwise slowly until the operation indicator is lit. Move the sensing for a necessary differential travel distance (i.e., 1% to 5% of the rated sensing distance) and turn the MD adjuster counterclockwise slowly until the operation indicator turns off. Then move the sensing and check that the Sensor detects the when the is in the sensing distance range. Shorten the distance between the Sensor and sensing and fix the position of the Sensor where both the operation indicator and stability indicator are lit to complete the sensitivity adjustment. 1. If the Amplifier Unit malfunctions due to radical ambient temperature changes, further shorten the distance between the Sensor and sensing to 80% maximum of the set distance. 2. The -JC4A has no function to adjust differential travel. Therefore, take steps 2 and 4 only. Adjustment Model -JC4AP Step 1 2 3 Sensitivity adjuster --- --- Adjustment Obtain the sensing distance X from the set distance S divided by 0.8. Determine S so that X will be less than the maximum sensing distance. Locate the Sensor so that the distance between the Sensor and sensing is X. Turn the sensitivity adjuster clockwise or counterclockwise until the red operation indicator is lit. Return the Sensor to the previous position so that the distance between the Sensor and sensing is S. Secure the position of the Sensor to complete the sensitivity adjustment. The green stability indicator must be lit when the sensing is located within the sensing distance and not lit when the sensing is completely outside the sensing distance. If the Amplifier Unit malfunctions due to radical ambient temperature changes, further shorten the distance between the Sensor and sensing to 80% maximum of the set distance. A caution label is provided with the Amplifier Unit. After completing sensitivity adjustment, affix the caution label over the adjuster hole of the cover to prevent mis-operation of the Amplifier Unit. 8

Engineering Data Operating Range (Typical) -CR5B -CR8j -X1A/-C1A : Iron 5x5x1mm distance (variable): 0.2 to 0.5 mm : Iron 5x5x1mm distance (variable): 0.16 to 0.8 mm : Iron 5x5x1mm distance (variable): 0.2 to 1 mm 2-dia. Head Y (mm) -CR8j Head Y (mm) -X1A Head -C1A Head Y (mm) E2EC-X1R5A E2EC-X2A E2EC-X5A : Iron 8x8x1mm distance (variable): 0.3 to 1.5 mm : Iron 12 x 12 x 1 mm distance (variable): 0.4 to 2 mm : Iron 18x18x1mm distance (variable): 1 to 5 mm -X1R5A Head Y (mm) -X2A Head Y (mm) -X5A Head Y (mm) E2EC-CX10A E2EC-C20MA : Iron 30x30x1mm distance (variable): 2 to10 mm : Iron 50x50x1mm distance (variable): 4 to 20 mm -X10A Head Y (mm) -X20MA Head Y (mm) 9

Distance vs. Object (Typical) E2EC-CR5B -CR8j -X1A/-C1A Iron Iron Iron Stainless steel (SUS304) Brass Aluminum Size of sensing! (mm) Size of sensing! (mm) Size of sensing! (mm) E2EC-X1R5A E2EC-X2A E2EC-X5A Iron Stainless steel (SUS304) Brass Aluminum Iron Stainless steel (SUS304) Brass Aluminum Iron Stainless steel (SUS304) Brass Aluminum Size of sensing! (mm) Size of sensing! (mm) Size of sensing! (mm) E2EC-CX10A E2EC-C20MA Iron Stainless steel (SUS304) Brass Aluminum Iron Stainless steel (SUS304) Brass Aluminum Size of sensing! (mm) Size of sensing! (mm) 10

Nomenclature -Gj4j Single-function Model Settings indicator (red) The transistor is ON when the sensing is detected. selector The transistor is ON when the sensing is not detected. Sensitivity adjuster (4-turn potentiometer) -JC4A Multi-function Model Settings The transistor is ON when the sensing is detected. Mounting screw The transistor is ON when the sensing is not detected. OFF-delay terminals OFF-delay Timer The 40-ms OFF-delay timer will be enabled if the OFF-delay terminals are short-circuited. Stability indicator Sensitivity adjuster indicator selector -JC4AP Self-diagnostic Output Model Settings The transistor is ON when the sensing is detected. Mounting screw The transistor is ON when the sensing is not detected. Cable length selector terminals OFF-delay Timer The OFF-delay timer is disabled. The 40-ms OFF-delay timer is enabled. Stability indicator Sensitivity adjuster Timer switch indicator selector Cable Length Compensation The type of cable length compensation is selectable with the cable length selector terminals. 1 to 3 m: Short-circuit the cable length selector terminals. 3 to 5 m: Open the cable length selector terminals. 11

-WH4A(F) Multi-function Model Settings The transistor is ON when the sensing is detected. The transistor is ON when the sensing is not detected. Cable Length Compensation Switch Cable length selector switch selector indicator (red) Sensitivity adjuster (4-turn potentiometer) 5m 3m The cable length of the Proximity Sensor in use is set to 3 m. 5m 3m The cable length of the Proximity Sensor in use is set to 5 m. -Aj4A Multi-function Model Settings The transistor is ON when the sensing is detected. The transistor is ON when the sensing is not detected. selector Cable length compensation switch NO CABLE Min OUTPUT NC A B C D Max MD OPERATION STABILITY Low High SENSITIVITY indicator (red): Lit when the sensing is detected. Stability indicator (green): Lit when the Sensor is in smooth detection and non-detection. (ON: Stable; OFF: Unstable) Sensitivity adjuster MD (differential travel) adjuster Cable Length Compensation Switch Refer to the following table to set the cable length compensation switch according to the cable length. Cable length Applicable Sensors -CR8A -CR8B -X1A -C1A -X1R5A -X2A -X5A -X10A -X20MA Switch settings of amplifier unit 0to1m 1to2m 2to3m 3to4m 4to5m 5to6m 6to7m 7to8m 8to9m 9to 10 m --- --- --- --- --- 1. If more than two Sensors with the same diameter and length cable are closely mounted side by side, set the switch to a value that is 1 m different from the actual length. Except for the -C20MA, this method can protect the sensors from mutual interference. 2. Set all the pins of the switch to the left if the -CR5B is used in combination with the -AM4A or -AK4A. 12

Dimensions All units are in millimeters unless otherwise indicated. Sensors -CR5B 2dia. 1.2-dia. shielded cable with a conductor; standard length: 3 m -CR8A/-CR8B 3.5 dia. (see note) 3.5 dia. 2.5-dia. coaxial cable; standard length: 3 m The diameter of the coaxial cable is 3.8 mm for the -CR8B. -X1A 2.5-dia. coaxial cable; standard length: 3 m -C1A 5.4 dia. 2.5-dia. coaxial cable; standard length: 3 m -X1R5A 2.5-dia. coaxial cable; standard length: 3 m -X2A 2.5-dia. coaxial cable; standard length: 3 m 13

-X5A 4.1-dia. coaxial cable; standard length: 3 m -X10A 5.5-dia. coaxial cable; standard length: 3 m -C20MA 40 dia. 5.5-dia. coaxial cable; standard length: 3 m Mounting Hole Dimensions Model F (mm) -CR5B 2.2 +0.3 -- 0 dia. -CR8A 3.7 +0.3 -- 0 dia. -CR8B 4.0 +0.3 -- 0 dia. -C1A 5.7 +0.3 -- 0 dia. -X1A 5.5 +0.5 -- 0 dia. -X1R5A 8.5 +0.5 -- 0 dia. -X2A 12.5+0.5 -- 0 dia. -X5A 18.5 +0.3 -- 0 dia. -X10A 30.5 +0.3 -- 0 dia. -C20MA 18.5 dia. +0.3 -- 0 14

Amplifier Units -AM4A -Gj4j 48 square 44.8 square -WH4A (F) Connector to S3D-jjF Two, M4 screw holes To be mounted on DIN track -JC4A Four, M2.6 terminals Location of caution label (provided with -JC4A) (see note) Mounting Bracket (Provided with -JC4A) Vinyl-insulated round cable with three conductors, 4 dia. (0.2 mm 2 x 3 (18/0.12)); standard length: 2 m Two, 1.65 radius 1.55 radius 3.3 dia. 1.65 radius Mounting bracket (provided with -JC4A) Four, 1 radius Affix the caution label after the sensitivity adjustment of the -JC4A. 15

-JC4AP indicator Stability indicator Timer switch Operating mode selector Mounting Bracket (provided with -JC4AP) 1.7 radius Sensitivity adjuster Caution label (provided with -JC4AP) (see note 1) Two, 3.3 dia. Code (see note3) Mounting bracket (provided with -JC4AP) 1. Paste the caution label after the sensitivity adjustment of the -JC4AP to prevent mis-operation. 2. The mounting bracket will not be required if the -JC4AP is mounted to DIN tracks. 3. Vinyl-insulated round cable with four conductors, 4.5 dia. (18/0.12); standard length: 2 m Installation Connection -AK4A Sensor Head Shielded cable Transistorized photocoupler -AM4A Sensor Head Shielded cable P2CF-11 P2CF-08 Amplifier Unit: -AK4A Amplifier Unit: -AM4A Applicable Socket: P2CF-11 100 to 240 VAC Relay contact Applicable Socket: P2CF-08 12 to 24 VDC NPN PNP -JC4A -JC4AP Sensor Head Sensor Head Shield Conductor Brown (Red) 10 to 30 VDC Black (White) NPN open collector Blue (Black) Shield Conductor Brown (Red) 10 to 30 VDC Black (White) NPN open collector Blue (Black) Orange (Yellow) Self-diagnostic 16

-Gj4j Sensor unit -WH4A (F) 12to24VDC Shielded cable PNP NPN NPN for -GE4j PNP for -GF4j Sensor Head 12 to 24 VDC Coaxial cable Load Connection -GE4j Load/Model Direct load driving $ Relay $ Solenoid Amplifier Unit DC solid-state load $ Programmable Controller $ Sensor Controller Voltage load (logic circuitry) Amplifier Unit -GE4j Load 12 to 24 V +V To next stage Remarks -GC4A Load/Model Direct load driving $ Relay $ Solenoid Tr I C: 200 ma min. H FE: 50 min. V CED: 30 V nin. Interface circuitry DC solid-state circuitry The C-MOS IC or TTL can be connected to the -GE4j through the interface and DC solid-state circuitry as shown in the above circuit diagram. -GC4A Brown (Red) Load Black (White) Blue (Black) Current-absorbing load $ Programmable Controller $ Sensor Controller Brown (Red) Load Black (White) Blue (Black) Voltage load (logic circuitry) Brown (Red) Black (White) 12 to 24 V +V Blue (Black) To next stage Interface circuitry Logic circuitry) 17

-WH4A(F) The -WH4A(F) has NPN and PNP open collector s. Therefore, there is a degree of freedom in load types and power supply polarity. Load Direct load driving DC solid-state load Voltage load (logic load) Relay Current-absorbing load Model Solenoid Programmable Controller S3D8 Sensor Controller - WH4A (F) PNP Load (See note) 12 to 24 V NPN Load (See note) 12 to 24 V NPN Load PNP 12 to 24 V Do not impose a voltage exceeding 40 V on the load if the load is connected to an independent power supply. Connect the load to the PNP if the load discharges current. -AK4A, -AM4A The -AK4A has relay contact and transistor photocoupler s and the -AM4A has NPN and PNP open collector s. Therefore, there is a degree of freedom in load types and power supply polarity. Model -AK4A -AM4A Load Direct load driving $ Relay $ Solenoid Amplifier Unit Relay contact Load Power supply DC or AC Amplifier Unit 12 to 24 V PNP NPN Load Load DC solid-state load Current-absorbing load $ Programmable Controller $ Sensor Controller (S3D8) Voltage load (logic load) Amplifier Unit Amplifier Unit Transistor photocoupler Load Connect the load to negative transistor photocoupler if the load discharges current. Transistor photocoupler (12to24V) Amplifier Unit Amplifier Unit Do not impose a voltage exceeding 40 V on the load if the load is connected to an independent power supply. 2 12 to 24 V PNP NPN Load Connect the load to PNP if the load discharges current. 12 to 24 V PNP 18

Accessories (Order Separately) Connecting Socket Models Amplifier Track- Back-connecting Socket Unit mounting Socket (see Solder Screw note) terminal terminal -AK4A P2CF1-11 PL11 P3GA-11 -AM4A P2CF-08 PL08 P3G-08 -Gj4j PYF08A PY08 PYF08M Track-mounted socket can be used as a front-connecting socket. Track-mounted Socket/Front-connecting Socket Top View Socket Bottom View Socket P2CF-11 Terminal Arrangement Mounting Holes Eleven M3.5 x 7.5 sems Two 4.5 dia. mounting holes 70 max. Two 4.5 dia. holes 50 max. 31 max. (Top view) P2CF-08 Terminal Arrangement Mounting Holes Eight M3.5 x 7.5 sems Two 4.5 dia. or Two M4 70 max. Two 4.5 dia. holes 50 max. 20 max. (Top view) PYF08A Terminal Arrangement Mounting Holes Two 4.2 x 5 mounting holes Eight M3 x 8 sems TwoM3orM4 (Two 4.5 dia. holes) 72 max. 23 max. (Bottom view) 30 max. 19

Back-connecting Socket P3GA-11 27 dia. Front View Terminal Arrangement P3G-08 27 dia. (Front view) Mounting Dimensions Embedding Adapter Y92F-30 (l = 45) Y92F-71 (l = 55) Terminal Arrangement Embedding Adapter Y92F-70 Two, 4.5-dia. adapter mounting holes R0.5 max. 52 to 53 65 to 66 PY08 Eight 3 x 1.2 elliptic holes Terminal Arrangement Panel Cutout (see note) Eight 3 x 1.2 elliptic holes 25.5 max. 29.5 max. 42 max. 20 max. 24 max. (Bottom view) Model PY08-1 includes the dimensions shown in dotted lines. PL11 Mounting Holes Two 2 dia. holes Two 3.5 dia. or two M3 socket-mounting holes 51 max. 30 dia. 31 dia. hole 35 max. Approx. 20.5 20

PL08 Terminal Arrangement Mounting Holes Two 3.5 dia. or two M3 socket-mounting holes 50.5 max. 30 dia. Two 2 dia. holes 31 dia. hole 35 max. Approx. 20.5 (Bottom view) PYF08M 3dia. 40 max. 3.5 dia. hole 3.5dia.holeorM3 44.5 max. 18 max. 3.5 dia. mounting hole 6.5 dia. spot facing Depth: 11.5 M3.5 sems are used for terminal screws. Mounting Fixture Y92E-Bj Plastic Mounting Fixtures are available as options. Select one suited to the dimensions of the Sensor. Adapter for Flush Mounting Y92F-30 Panel P3GA-11 Rear Connecting Socket Panel Cutout R0.5 max. Recommended panel thickness is 1 to 3.2 mm. 21

Precautions Mounting Do not apply excessive torque to the mounting nuts of the -X or -C20MA. Be sure to tighten each nut with a toothed washer. Effects of Surrounding Metal When mounting the within a metal panel, ensure that the clearances given in the following table are maintained. ddia. Model Tightening torque -X1A 10 kgf S cm {0.98 N S m} -X1R5A 20 kgf S cm {2.0 N S m} -X2A 60 kgf S cm {5.9 N S m} -X5A 150 kgf S cm {15 N S m} -X10A 400 kgf S cm {39 N S m} -X20MA 150 kgf S cm {15 N S m} Apply above tightening torque to each nut tightened with a toothed washer. Tighten the screw to a torque of 2 kgf S cm (0.2N S m) max. to secure the non-screw models. M3 set screw hole Dimensions Y92E-F3R5 7to11.5mm Y92E-F3R5 Mounting Bracket (with 3.5 dia. holes) (Sold separately) The Y92E-F5R4 with 5.4-dia. holes is also sold separately. Y92E-F5R4 (mm) Models! d D m -CR5B 2 6 2 1.5 -CR8 0 (3.5) 0 2.4 -X1A 0 (5) 0 3 -C1A 0 (5.4) 0 3 -X1R5A 0 (8) 0 4.5 -X2A 0 (12) 0 6 -X5A 0 (18) 0 15 -X10A 0 (30) 0 30 -C20MA 25 120 40 60 Figures in parentheses indicate diameters of shielded models. Mutual Interference When mounting more than two s face to face or side by side, ensure that the minimum distances given in the following table are maintained. Except for the -CR5B, -C20MA, and -Gj4A, mutual interference can be prevented with the setting of the cable length selector of each model. This, however, changes coil characteristics and the ratings may not be ensured at some temperatures or sensing distances. Be sure that the Sensors operate normally after cable length change. (mm) Model A B -CR5B 20 15 -CR8 20 15 -X1A 20 15 -C1A 20 15 -X1R5A 20 15 -X2A 30 20 -X5A 50 35 -X10A 100 70 -C20MA 300 200 The above values are possible with the differential travel of each model set to 5%. 22

Mounting the Amplifier Unit -JC4A $ Vertical Mounting 1. Mount the Mounting Bracket with the M3 screw provided with the -JC4A. 2. Slide and insert the protruding part of the -JC4A into the hole of the mounting bracket. 3. Mount the -JC4A with the mounting screw. 4. Mount the cover on the casing. -JC4AP $ Mounting 1. Mount the front part of the -JC4AP to the Mounting Bracket provided or a DIN track. 2. Press the rear part of the -JC4AP onto the Mounting Bracket or DIN track. Front part Rear part Mounting screw Fixture rail (yellow) DIN track or Mounting Bracket Mounting Bracket Mounting surface M3 screw $ Side Mounting 1. Remove the cover tightening screw and mounting screw. 2. Mount the cover on the casing using the M3 screw provided with the -JC4A. 3. Mount the -JC4A by inserting and tightening the M3 screws on the side of the -JC4A. $ Dismounting 3. Pull the fixture rail with a flat-blade screwdriver so that the -JC4AP can be dismounted with ease. -WH4A(F) $ Mount the -WH4A(F) to a DIN track as shown in the following illustration. $ Hook part (A) of the -WH4A(F) to the DIN track and press -WH4A(F) in the direction indicated by the arrow (B). Cover tightening screw DIN35 track (PFP-100N or PFP-100N2) Mounting screw M3 screw Mounting surface $ Dismounting from DIN Track Pull the rail stopper indicated by arrow (C) upwards with a flat-blade screwdriver to dismount the -WH4A(F) from the DIN track. If the track is DIN35 track, the -WH4A(F) can be easily dismounted by creating a 30-mm space between the -WH4A(F) and other s. M3 screws 30 mm min. $ After adjusting the -JC4A, affix the caution label over the adjuster hole of the cover to prevent the mis-operation. Rail stopper (white) (C) 30 mm min. 23

-Aj4A $ If more than -Aj4A Amplifier Unit is vertically mounted with the P2CF-11 or P2CF-08 side by side, it will be convenient to leave a 20-mm space on both the upper and lower sides where the hooks are located. Dismounting the Amplifier Unit $ In the case of the Y92F-30 Mounting Adapter, loosen the screws of the Adapter, spread out the hooks, and remove the Mounting Adapter. Hook Duct Panel P2CF-11 P2CF-08 $ Panel Mounting 1. If the Y92F-30 Mounting Adapter is used for the panel mounting of the -Aj4A, insert the -Aj4A into the square hole of the panel first. Next attach the Mounting Adapter from the rear side and press the Mounting Adapter to reduce the space between the Adapter and the panel as much as possible, then secure the Mounting Adapter with screws. $ In the case of the Y92F-70 or Y92F-71 Mounting Adapter, press the hook inwards using the thumb and index finger of both hands, and press the -Aj4A towards the front side. Panel Y92F-30 2. If the Y92F-70 or Y92F-71 Mounting Adapter is used, just insert the -Aj4A into the square panel hole. If the panel coating is too thick and the hooks do not snap on, spread out the hooks appropriately up and down after inserting the -Aj4A into the hole. Spread after insertion Hook Panel Wiring the Self-diagnostic Output $ If self-diagnostic will not be used, connect the yellow lead wire to the 0-V terminal or cut and cover the yellow lead wire with insulation tape so that the yellow lead wire will not be in contact with other terminals. Spread after insertion ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. D030-E1-5 OMRON Corporation Systems Components Division H.Q. 28th Fl., Crystal Tower Bldg. 1-2-27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6012 Fax: 06-949-6021 In the interest of product improvement, specifications are subject to change without notice. Printed in Japan 0997-0.5M a 24