Long-barrel Inductive Proximity Sensor EE CSM_EE_DS_E Proximity Sensor with a Long Screw Length Increased tightening strength. Cable protectors provided as a standard feature. Increased indicator visibility. milled section for wrench grip on all models. Be sure to read Safety Precautions on page 9. Ordering Information Sensors DC -Wire Models Model ppearance Sensing distance M mm EE-D M * EE-D M M 7 mm EE-7D M * EE-7D M M mm EE-D M * EE-D M M mm EE-MD M * EE-MD M M mm EE-MD M * EE-MD M M mm EE-MD M * EE-MD M * Models with different frequencies are also available. The model numbers are EE-@D (example: EE-D). DC -Wire Models ppearance Sensing distance Model M mm EE-C M EE-C M M mm EE-C M EE-C M M mm EE-C M EE-C M M mm EE-MC M EE-MC M M mm EE-MC M EE-MC M M mm EE-MC M EE-MC M C -Wire Models ppearance Sensing distance Model M mm EE-Y M EE-Y M M mm EE-Y M EE-Y M M mm EE-Y M EE-Y M M mm EE-MY M EE-MY M M mm EE-MY M EE-MY M M mm EE-MY M EE-MY M
EE ccessories (Order Separately) Mounting Brackets Protective Covers Sputter Protective Covers Ratings and Specifications EE-@D@ DC -Wire Models Size M M M Shielding Item Model EE-D@ EE-MD@ EE-7D@ EE-MD@ EE-D@ EE-MD@ Sensing distance mm±% mm±% 7 mm±% mm±% mm±% mm±% Set distance to. mm to. mm to. mm to. mm to mm to mm Differential travel % max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page.) Standard sensing object mm mm mm mm mm Response frequency * khz Hz Hz Hz Hz Power supply voltage (operating voltage range) to VDC ( to VDC), ripple (p-p): % max. Leakage current. m max. Control output Indicators Switching to m capacity Residual voltage V max. (Load current: m, Cable length: m) D Models: Operation indicator (red) and setting indicator (green) D Models: Operation indicator (red) D Models: D Models: Refer to the timing charts under I/O Circuit Diagrams on page for details. (with sensing object approaching) Protection circuits mbient temperature mbient humidity Surge absorber, Load short-circuit protection Operating/Storage: to 7 C (with no icing or condensation) Operating/Storage: % to 9% (with no condensation) Temperature influence ±% max. of sensing distance at C in the temperature range of to 7 C Voltage influence ±% max. of sensing distance at rated voltage in the rated voltage ±% range Insulation resistance MΩ min. (at VDC) between current-carrying parts and case Dielectric strength VC, / Hz for minute between current-carrying parts and case Vibration resistance to Hz,.-mm double amplitude for hours each in, Y, and Z directions Shock resistance, m/s times each in, Y, and Z directions Degree of protection IEC IP7, in-house standard for oil resistance Connection method Pre-wired Models (Standard cable length: m) Weight (packed state) pprox. g pprox. g pprox. g Case Materials Sensing surface PBT Clamping nuts Nickel-plated brass Zinc-plated iron ccessories Instruction sheet mm. Use the EE within the range in which the setting indicator (green LED) is (except D Models). *. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
EE EE-@C@ DC -Wire Models Size M M M Shielding Item Model EE-C@ EE-MC@ EE-C@ EE-MC@ EE-C@ EE-MC@ Sensing distance mm±% mm±% mm±% mm±% mm±% mm±% Set distance to. mm to mm to mm to mm to mm to mm Differential travel Standard sensing object % max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page.) mm mm mm mm mm Response frequency. khz Hz Hz Hz Hz Hz Power supply voltage (operating voltage range) * to VDC ( to VDC), ripple (p-p): % max. Leakage current m max. Control Load current NPN open-collector output, m max. ( VDC max.) output Residual voltage V max. (Load current: m, Cable length: m) Indicators Operation indicator (red) C Models: C Models: Refer to the timing charts under I/O Circuit Diagrams on page for details. (with sensing object approaching) Protection circuits mbient temperature mbient humidity Reverse polarity protection, Surge absorber, Load short-circuit protection Operating/Storage: to C (with no icing or condensation) Operating/Storage: % to 9% (with no condensation) Temperature influence ±% max. of sensing distance at C in the temperature range of to C ±% max. of sensing distance at C in the temperature range of to 7 C Voltage influence ±% max. of sensing distance at rated voltage in the rated voltage ±% range Insulation resistance MΩ min. (at VDC) between current-carrying parts and case Dielectric strength, VC, / Hz for minute between current carry parts and case Vibration resistance to Hz,.-mm double amplitude for hours each in, Y, and Z directions Shock resistance, m/s times each in, Y, and Z directions Degree of protection IEC IP7, in-house standard for oil resistance Connection method Pre-wired Models (Standard cable length: m) and Connector Models Weight (packed state) pprox. 7 g pprox. g pprox. g Case Materials Sensing surface PBT Clamping nuts Nickel-plated brass Zinc-plated iron ccessories Instruction sheet mm. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *. full-wave rectification power supply of VDC ±% (average value) can be used.
EE EE-@Y@ C -Wire Models Size M M M Shielding Item Model EE-Y@ EE-MY@ EE-Y@ EE-MY@ EE-Y@ EE-MY@ Sensing distance mm±% mm±% mm±% mm±% mm±% mm±% Set distance to. mm to mm to mm to mm to mm to mm Differential travel Standard sensing object % max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page.) mm mm mm Response frequency Hz Power supply voltage (operating voltage range) to VC ( to VC), / Hz Leakage current.7 m max. Control Load current * to m to m output Residual voltage Refer to Engineering Data on page. Indicators Operation indicator (red) Y Models: Y Models: mm mm Refer to the timing charts under I/O Circuit Diagrams on page for details. (with sensing object approaching) mbient temperature, mbient humidity Operating/Storage: to C (with no icing or condensation) Operating/Storage: % to 9% (with no condensation) Temperature influence ±% max. of sensing distance at C in the temperature range of to C, ±% max. of sensing distance at C in the temperature range of to 7 C Voltage influence ±% max. of sensing distance at rated voltage in the rated voltage ±% range Insulation resistance MΩ min. (at VDC) between current-carrying parts and case Dielectric strength, VC, / Hz for minute between current carry parts and case Vibration resistance to Hz,.-mm double amplitude for hours each in, Y, and Z directions Shock resistance, m/s times each in, Y, and Z directions Degree of protection IEC IP7, in-house standard for oil resistance Connection method Pre-wired Models (Standard cable length: m) and Connector Models Weight (packed state) pprox. g pprox. g pprox. g Case Materials Sensing surface PBT Clamping nuts Nickel-plated brass Zinc-plated iron ccessories Instruction sheet mm. When supplying VC to any of the above models, make sure that the operating ambient temperature range is at least C to C. *. When using an M or M Connector Model at an ambient temperature between 7 and C, make sure that the Sensor has a control output (load current) of to m max.
Y Engineering Data (Reference Value) EE Sensing rea Models EE-@D@ EE-@C@/-@Y@ Distance (mm) EE- EE-7 Distance (mm) EE- Y EE- EE- EE - Models EE-@MD@ Distance (mm) Y Distance Y (mm) EE -M EE -M EE -M EE-@MC@/-@MY@ Distance (mm) Y Distance Y (mm) EE-M EE-M EE-M Distance Y (mm) Distance Y (mm) Leakage Current Residual Output Voltage EE-@D@ EE-@Y@ EE-@D@ Leakage current (m)... Leakage current (m).... Residual output voltage (V).. Power supply voltage (V)... Proximity Sensor () m V Protective resistance C power Power supply voltage (V) Load current (m)
EE EE-@Y@ at VC EE-@Y@ at VC EE-@Y@ at VC Load voltage VL (V) Residual output voltage VC Residual load voltage V VL Load current (m) Load voltage VL (V) Residual output voltage Residual load voltage V VL VC Load current (m) Load voltage VL (V) Residual output voltage Residual load voltage V VL VC Load current (m) Influence of Sensing Object Size and Material EE-D@ EE-7D@ EE-D@ Distance (mm).... (SUS) Distance (mm) 7 (SUS) Distance (mm) (SUS) EE-MD@ EE-MD@ EE-MD@ Distance (mm) (SUS) Distance (mm) (SUS) Distance (mm) 7 (SUS) 7 7 7 9
EE EE-C@/-Y@ EE-C@/-Y@ EE-C@/-Y@ Distance (mm).. (SUS) Distance (mm) 7 (SUS) Distance (mm) (SUS). EE-MC@/-MY@ EE-MC@/-MY@ EE-MC@/-MY@ Distance (mm) 7 Distance (mm) Distance (mm) (SUS) (SUS) (SUS) 7
I/O Circuit Diagrams EE DC -Wire Models Operation mode Model Timing Charts Output circuit EE-D EE-7D EE-D EE-MD EE-MD EE-MD Non-sensing area Sensing object Unstable sensing area Set position Stable sensing area Proximity Sensor (%) Rated sensing distance Setting indicator (green) Operation indicator (red) Proximity Sensor main circuit Brown Load +V EE-D EE-7D EE-D EE-MD EE-MD EE-MD Sensing object (%) Non-sensing area Stable sensing area Rated sensing distance Proximity Sensor Operation indicator (red) Blue V Note: The load can be connected to either the +V or V side. DC -Wire Models Operation mode Model Timing Charts Output circuit EE-C EE-C EE-C EE-MC EE-MC EE-MC EE-C EE-C EE-C EE-MC EE-MC EE-MC Present Not present Operation indicator (red) Present Not present Operation indicator (red) Proximity Sensor main circuit Ω Brown Black Blue Load +V V
EE C -Wire Models Operation mode Model Timing Charts Output circuit EE-Y EE-Y EE-Y EE-MY EE-MY EE-MY EE-Y EE-Y EE-Y EE-MY EE-MY EE-MY Present Not present Operation indicator (red) Present Not present Operation indicator (red) Proximity Sensor main circuit Brown Load Blue Safety Precautions WRNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Correct Use Do not use this product under ambient conditions that exceed the ratings. Design Influence of Surrounding Metal When mounting the Sensor within a metal panel, ensure that the clearances given in the following table are maintained. m D d dia. m n (Unit: mm) DC -Wire Models EE-@D@ DC -Wire Models EE-@C@ C -Wire Models EE-@Y@ Model Item M M M l d D m n 7 l d 7 9 D m 7 n 7 9 l d D m n 7 l d 9 D m 7 n 9 9
EE Mutual Interference When installing Sensors face-to-face or side-by-side, ensure that the minimum B distances given in the following table are maintained. Mutual Interference Model Item M M M DC -Wire Models EE-@D@ DC -Wire Models EE-@C@ C -Wire Models EE-@Y@ Note: Values in parentheses apply to Sensors operating at different frequencies. Mounting T i g h B B () () () () () () () () (Unit: mm) () 7 () () () B 7 B Relationship between Sizes and Models Size Model EE-D@ EE-C@ EE-Y@ M EE-MD@ EE-MC@ EE-MY@ EE-7D@ EE-C@ EE-Y@ M EE-MD@ EE-MC@ EE-MY@ EE-D@ EE-C@ EE-Y@ M EE-MD@ EE-MC@ EE-MY@ tening Torque Do not tighten the nut with excessive force. washer must be used with the nut. The following strengths assume washers are being used. Model M M M Torque N m 7 N m N m
EE Dimensions (Unit: mm) Unless otherwise specified, the tolerance class IT is used for dimensions in this data sheet. EE-D@/EE-C@/EE-Y@ EE-MD@/EE-MC@/EE-MY@ dia. 7 9 dia. 7 7 9 M Two clamping nuts Indicators *. -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:. mm), Standard length: m -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:. mm), Standard length: m The cable can be extended to up to m (Separate metal conduit.) *. D Models: Operation indicator (red) and setting indicator (green), 9 dia. M Two clamping nuts Indicators *. -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:. mm), Standard length: m -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:. mm), Standard length: m The cable can be extended to up to m (Separate metal conduit.) *. D Models: Operation indicator (red) and setting indicator (green), EE-7D@/EE-C@/EE-Y@ 9 dia. EE-MD@/EE-MC@/EE-MY@ 9 dia. M Two clamping nuts Indicators *. -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:.9 mm), Standard length: m -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:.9 mm), Standard length: m The cable can be extended to up to m (Separate metal conduit.) *. D Models: Operation indicator (red) and setting indicator (green),. dia. M Indicators * Two clamping nuts. -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:.9 mm), Standard length: m -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:.9 mm), Standard length: m The cable can be extended to up to m (Separate metal conduit.) *. D Models: Operation indicator (red) and setting indicator (green), EE-D@/EE-C@/EE-Y@ 7 dia. EE-MD@/EE-MC@/EE-MY@ dia. 7 Indicators * M. Two clamping nuts. -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:.9 mm), Standard length: m -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:.9 mm), Standard length: m The cable can be extended to up to m (Separate metal conduit.) *. D Models: Operation indicator (red) and setting indicator (green),. dia. Indicators * M. Two clamping nuts. -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:.9 mm), Standard length: m -dia. vinyl-insulated round cable with conductors (Conductor cross section:. mm, Insulator diameter:.9 mm), Standard length: m The cable can be extended to up to m (Separate metal conduit.) *. D Models: Operation indicator (red) and setting indicator (green), Mounting Hole Dimensions Dimension M M M F (mm) +.. dia. +.. dia. +.. dia. F Note. Two clamping nuts and one toothed washer are provided with each Sensors.. The model number is laser-marked on the cable section and milled section. In the interest of product improvement, specifications are subject to change without notice.