OPERATING & MAINTENANCE MANUAL

Similar documents
OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

OPERATING AND MAINTENANCE MANUAL

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

TECHINCAL DESCRIPTION BIO BAN

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

SafeFAST Elite IVF guard

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

OPERATING & MAINTENANCE MANUAL

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

FlowFAST H. Horizontal Laminar Flow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET

Angelantoni Life Science. Microbiological safety cabinets Class II. SterilSafe Series

Handbook Of Microbiological Safety Cabinet Type BIO II 9 (4 ft) and 12 (3 ft)

ASALAIR BIOHAZARD ATLANTIC CABINET MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET.

SafeFAST Premium. Class II Microbiological Safety Cabinets THE LOWEST POWER CONSUMPTION THE LOWEST CO 2 EMISSIONS THE LOWEST NOISE LEVEL

HORIZONTAL LAMINAR FLOW HOOD FLO

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

ASALAIR BIOHAZARD ATLANTIC CABINET MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2 MODEL:

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

VERTICAL LAMINAR FLOW HOOD MODEL 700 PARTICULARLY SUITABLE FOR PCR PROCESS CODE

USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS

ASALAIR BIOHAZARD CABINET ATLANTIC 1200 CLASS II TYPE B2 COD

Handbook Of Microbiological Safety Cabinet Type OPTIMALE

VERTICAL LAMINAR FLOW HOOD FLV

FASTER ChemFAST. Laboratory Fume Cupboards PROTECTION, SAFETY, RELIABILITY. AND MORE.

Mod: KLD6-12/35XLAS-N

INSTRUCTION AND USE MANUAL

PRODUCT CATALOG CLASS II BIOLOGICAL SAFETY CABINET.

ECONOMISER SERIES E2T USER MANUAL

WATERFLUX 3070 Quick Start

Biological Safety Cabinet

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Switching DC Power Supply

Operating instructions

ASALAIR FUME CUPBOARD /R WITH HEPA FILTER

Class II biological safety cabinets

A Thermolab Group Company. HyZone. Class II Microbiological Safety Cabinets. for operator, environment and product protection.

EC200 ELECTRONIC CONTROL SYSTEM

CLASS II BIOSAFETY CABINET

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

UV-cabinet DNA/RNA UVC/T-M-AR

PURE SINE WAVE DC TO AC POWER INVERTER

ASALAIR BIOHAZARD ATLANTIC CYTOCABINET MODEL: ATLANTIC CYTOCABINET CODE ATLANTIC CYTOCABINET CODE

Heat Meter Integrator

Bio II Advance. Class II Biological Safety Cabinet

VCM LAMINAR FLOW HOOD VERTICAL

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

PCR 6. Operators Manual. Vertical Laminar Airflow Cabinet with U.V. Sterilisation. Issue 05 September 2013

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Oil-free piston compressors KK and piston vacuum pumps KV

Multi-Mover Charger for model L25

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Pump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min

TITAN, ATLAS & SIRIUS SMALL, PORTABLE. economical cabinets. with low energy consumption

Installation and Operating Instructions. Solar System Controller ISC3020

Bio II Advance. Class II Biological Safety Cabinet

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Isolator technology. eco safe Iso Compact. Width (m) EN Isolator. Class. Standard 0.9 / 1.2 II EN

CG2010 Cytogard Cytotoxic Drug Safety Cabinets

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings

Heavy Duty Series (HDS) Installation and user guide

DOSING UNIT WITH TIME CONTROL INSTRUCTIONS MANUAL WARNING!

DIGITAL BATTERY TESTER 12V

Installation and Operating Instructions. Solar System Controller ISC3030

Smart Charger 12-24V 60A, 1600W

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

SIZING OF SOLAR GENERATOR

TM Series MICROBIOLOGICAL SAFETY CABINETS. Technical Specifications

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

FILTRATION FUME CABINET MODELS T800 T1800 OPERATING AND MAINTENANCE MANUAL

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

PowerView PV380-R2 Mechanical Configuration

UVR-Mi UV-air flow Cleaner - Recirculator

CLASS II BIOLOGICAL SAFETY CABINET

PAC 600 PAC 800 PAC 800 comfort

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

SF-1000 workbench - welding table. User s Manual.

AXIAL FANS Axis / Tubo OPERATION MANUAL

OPERATIONS MANUAL CR Thermoreactor

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Transcription:

Commercial office: Via Merendi, 22 20010 Cornaredo (MI) Tel. +39.02.93.991.92 Fax. +39.02.93.991.608 E-mail: info@faster.dgroup.it OPERATING & MAINTENANCE MANUAL FlowFAST V P 00112EN REV. 04 02/2013 (ORIGINAL INSTRUCTIONS)

CONTENTS 1. GENERAL... 2 2. INSTALLATION... 3 2A. INSTRUCTIONS AND CHECKS ON DELIVERY... 3 2B. INSTALLATION REQUIREMENTS... 3 2C. ELECTRIC/GAS CONNECTIONS and INSTALLATION OF THE WORK SURFACE... 4 3. OPERATION PRINCIPLES... 6 4. OPERATION... 7 4A. SCOPE... 7 4B. CONTROLS OF SYSTEM AND PERFORMANCES... 7 4C. REMOTE SIGNALS (Optional for automatic regulation)... 7 4D. SYMBOLS of CONTROL BOARD... 8 4E. OPERATOR MENU... 12 5. HOUR COUNTER / UV TIMER (Optional)... 17 5A. Hours counter... 17 5B. UV Timer... 17 5C. Energy save... 18 6. DISPOSAL OF WASTES... 19 7. LIMITATIONS... 20 8. OPERATING PROCEDURES... 21 8A. PRELIMINARY CHECKS... 21 8B. SWITCHING ON the FLOWFAST V CABINET... 21 8C. SWITCHING OFF FLOWFAST V CABINET... 21 8D. U.V. LAMP POSITION... 22 9. MAINTENANCE... 23 9A. INSTRUCTION FOR DAILY CLEANING OF VERTICAL LAMINAR FLOW CABINETS (by users) 23 9B. REPLACEMENT OF HEPA FILTER (by technical assistance personnel)... 24 9C. REPLACEMENT OF MOTOR-FAN (by technical assistance personnel)... 25 9D. REPLACEMENT OF FLUORESCENT LAMPS (by user)... 26 9E. LIST OF SPARE PARTS... 27 10. TROUBLESHOOTING Probable causes of malfunctions... 28 11. TRANSPORT, PACKING an STORAGE INSTRUCTIONS... 29 12. ADDITIONAL INFORMATION... 31 12A. GUARANTEE... 31 12B. ADDRESS OF TECHNICAL ASSISTANCE (for the distributor)... 31 13. DIAGRAM FOR MAINTENANCE OPERATIONS... 32 13A. LEGENDA... 32 13B. FlowFAST V P... 33 14. FRONTAL DIAGRAM... 34 14A. FlowFAST V P... 34 15. SIDE DIAGRAM... 35 15A. FlowFAST V P... 35 16. SENSOR LIST... 36 17. WIRING DIAGRAM... 37 18. DECLARATION OF CONFORMITY... 41 00112EN REV. 04 03/2013 1

1. GENERAL FlowFAST V P VERTICAL LAMINAR AIRFLOW CABINETS provide high protection of material to be manipulated against contamination by protecting the working area from micro-organisms and airborne contaminants. These cabinets have been specifically designed to meet the demands of modern industrial laboratories where the protection of the product is required. Especially suitable for applications such as: Manipulation of material in a sterile area Cell culture Microbiology Molecular biology - PCR The performances of the cabinets are detailed in the TESTING CERTIFICATE herewith, in compliance with the requirements of: ISO 14644-1 Cleanrooms and associated controller environments Part 1: classification of air cleanliness on electric safety: EN 61010-1 Safety requirements for eletrical equipment for measurement, control and laboratory use Part 1: general requirements. All Faster s cabinets are provided with high insertion loss filters. FlowFAST V P vertical laminar airflow cabinets are marked "CE" (see label stuck on the right-hand side of the cabinet near the feeding cable) and meet the European Directive: 2006/42/EC 2004/108/EC 2006/95/EC Directive of the European Parliament and of the Council on machinery Directive of the European Parliament and of the Council on the approximation of the laws of the Member States relating to electromagnetic compatibility Directive of the European Parliament and of the Council on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits The FlowFAST cabinets comply with the above-mentioned Directives ONLY if the instrumentation that is connected to the electric socket (optional) positioned inside the work chamber are marked "CE", or in any case meet the standards mentioned above aiming to avoid any electromagnetic interference. Faster s.r.l. cannot be held responsible for malfunctions, damage to people or property due to non-compliance, poor or no maintenance, or improper use of the cabinet. N.B. : FLOWFAST V P cabinets MUST ABSOLUTELY NOT BE USED for handling pathogenic materials 00112EN REV. 04 03/2013 2

2. INSTALLATION 2A. INSTRUCTIONS AND CHECKS ON DELIVERY Considering the importance of the use of the laminar airflow FlowFAST V P cabinets and the need to keep them in optimum conditions, installation plays a major role to reach this aim. FlowFAST V P cabinets are positioned on a bench, wrapped in an extensible film and contained in a package of multi-layer strapped cardboard. For a general check of the instrument, having placed it in its utilization site, opened the package and removed the extensible film, control that the instrument has not suffered bucklings or scratches due to transport or wrong handling of the package. In case of a possible further transport, packing and storage by user after a first utilization period (e.g.: change of laboratory or factory), get in touch with the technical assistance service or the distributor for more accurate and precise indications or for a possible intervention by specialized technicians. The FlowFAST V cabinets, with or without package, shall be always sheltered from rain. 2B. INSTALLATION REQUIREMENTS Install the cabinet sheltered from draughts and heat sources (radiators, ventil-convectors), to ensure a good working. Install the instrument in a room with a low degree of dust and well aerated. Place the instrument far from doors and windows, which may cause malfunctions. Place the instrument in places where there is no people movement. The door of the room should be in such a position relatively to the cabinet as to prevent draught effects. A distance of 10 cm at least between the room ceiling and the outlet of exhausted air is of the essential. The temperature shall never fall under 0 C, to prevent the humidity present in the filtering screen from freezing, which might damage filters meshes: o max. temperature: 40 C o max. humidity: 80% at 31 C, linear drop in relative humidity down to 50% relative humidity at 40 C. Before connecting the cabinet to the mains, control the voltage and power necessary on the plate near the feed cable. The room shall be compulsory provided with earthing connection to gas and/or vacuum networks, if so required by the cabinet. As to the connection with gas and/or vacuum networks, read carefully chapter 2C. The quantity of heat generated by the cabinet is the following for the three models respectively: FlowFAST V 12 FlowFAST V 15 FlowFAST V 18 450 kcal/h 500 kcal/h 520 kcal/h To this heat, the heat due to possible bunsen burners or other instruments utilized by the client in the working area under laminar airflow should be added. The installation is made by technicians authorized by Faster s.r.l. 00112EN REV. 04 03/2013 3

2C. ELECTRIC/GAS CONNECTIONS and INSTALLATION OF THE WORK SURFACE The electric connection of the cabinet model FlowFAST is made by connecting the power cable located on the upper part of the right side of the cabinet to a suitable power point (see technical table). When the cabinet is connected, the green light on the control panel switches on. If so provided for by the laws in force, insert upstream on the feed line an automatic protection overload switch provided with a differential relay, whose rated switching voltage should not exceed 30 ma. The right side of the hood is also provided with one gas/vacuum intake with manual tap. The connection with the gas/vacuum intake is made according to the type of connection: town gas or industrial gas (air, vacuum, nitrogen, etc.). The cabinet must be connected with the town gas mains through an approved pipe, for safety reasons. For the installation of the work surface, proceed as follows: remove the protective paper from the work surface resting against the back of the cabinet, taking care not to scratch its surface, open the safety front window, clean the work surface with a damp cloth soaked in alcohol or soapy water or with a commonly available product designed for stainless steel, place the work surface in the work chamber, allowing the back to slide on the supporting basis of chamber up to its bottom wall close the shatterproof front window 00112EN REV. 04 03/2013 4

Techincal Features Table Description Unit FlowFAST V 12 FlowFAST V 15 FlowFAST V 18 Overall Dimensions (W x D x H) mm 1350 x760x1545 1655 x760x1545 1960 x760x1545 Usefull dimensions (W x D x H) mm 1198x609x755 1503x609x755 1808x609x755 Maximum front aperture mm 480 480 480 Working aperture mm 250 250 250 Weigh Kg 197 237 267 Noise level db (A) <65 <65 <65 Lighting level Lux >750 >750 >750 Nitrogen, CO 2, compressed air - maximum pressure bar 4 4 4 Fuel gas- maximum pressure mbar 20 20 20 Main voltage V 230V AC 2P+T 230V AC 2P+T 230V AC 2P+T Frequency Hz 50 50 50 Maximum power consumption W 1220 1350 1455 Current A 6,1 7,4 8,1 Electrical class 1 1 1 Protection level IP20 IP20 IP20 Internal outlet (maximum current for all the sockets: 4A) 2P+T 230V 4A 2P+T 230V 4A 2P+T 230V 4A Fluorescent lamps W 1x36 1x58 1x58 00112EN REV. 04 03/2013 5

3. OPERATION PRINCIPLES The following are the working principles of the vertical laminar airflow cabinet model FlowFAST V P: The air is sucked from a prefilter placed on the top of the cabinet the pressurized air pushed into the plenum of the motor-fan goes through the absolute filter and then downwards, in laminar flow, into the working chamber. Most of the air from here is exhausted trough the frontal opening. A little part of the air is sucked trough the slot in the rear part of the work chamber and recirculated 00112EN REV. 04 03/2013 6

4. OPERATION 4A. SCOPE The FlowFAST V P vertical laminar airflow cabinet class ISO 5 is manufactured according to the requirements of the international standards for the protection of the material manipulated in the working chamber. Our FlowFAST V P cabinets fully meet the requirements of Class ISO 5 according to ISO EN 14644-1 4B. CONTROLS OF SYSTEM AND PERFORMANCES FlowFAST V P cabinet is provided with a manual electronic regulation system, or, if installed, with automatic regulation system, to keep the airflow speed constant in the work chamber even by a progressive clogging of the HEPA filter up highest pressures. The front panel of hardened glass is hinged to facilitate the introduction of bulky objects and is provided with gas-springs for opening/closing and holding the open position. 4C. REMOTE SIGNALS (Optional for automatic regulation) The electronic control board can be improved with an output signal: it is possible to obtain a 12 Vdc output to connect a led light or alternatively a Normally Open voltage free contact to be connected to an external circuit. This signal can be set in three different modes: Motor ON: The signal starts when ventilation is turned ON and stops when ventilation is OFF. Alarm: That signal is ON in case of any flow alarm and it is OFF when air flow rate is in the correct range. LAF OK: That signal is ON when air flow rate is in the correct range and it is OFF in case of any flow alarm. 00112EN REV. 04 03/2013 7

4D. SYMBOLS of CONTROL BOARD List and description of all the symbols and controls of the control panel: 12 13 14 0 1 2 3 4 10 11 5 6 7 8 9 0 MAIN SWITCH: Position "0" Position "I" in the "0" position, the green light of the mains voltage is on [12]; the LCD displays the model name.in this position the operator can activate only the fluorescent light [7], the U.V. lamp [2] and the power outlet [8] (with plug installed) and can activate the data stored in the microprocessor by pressing the Right Arrows key [6]. Press key "I" [0], insert the password using the small numbers in the right lower corner of the keys and press SET. Default password is 5 4. When the password is typed in the green led of the switch lights up and the cabinet starts operating, the motor-blower is powered and first "CHECK PANEL" then "STAND-BY" appears on the display till the air flow reaches the pre-set value. In addition, an audible alarm will sound intermittently during this stand-by period, alerting the operator not to start working yet. When the audible alarm stops and the message "STAND- BY" disappears from the display, the cabinet is ready for use. The air velocity is displayed. NOTE: In any case, it is advisable to wait 5 minutes before starting work. 00112EN REV. 04 03/2013 8

1 STAND BY (speed reduction) By pushing the corresponding red key the password (the same to start the ventilation) is requested. Once confirmed the password the function is enabled. When it is enabled, the corresponding red LED lights up and, for single fan cabinets, the air speed is about 30% lower than their nominal speeds. The light and the gas electrovalve cannot be switched on. If they are on, they switch off automatically. If the PCB for the automatic regulation is installed following two messages appear alternatively: and: >>>ATTENTION<<< DANGER REDUCED AIRFLOW >>>DO NOT WORK<<< The SPEED REDUCTION function can be enabled only with the main switch in position I. Only the internal socket [8] can be operated. 2 U.V. (optional) Yellow key to switch on UV. This supplies the U.V. lamp in manual mode; when enabled, the display shows "U.V. on". The U.V. lamp switches on only if the cabinet is off, the lighting of the cabinet is off and the front window is completely closed. By pushing the relevant key you are requested to set the U.V working time. The timer resolution is 1 minute and the maximum time is 180 minutes (3 hours). The display will show the latest pre-set value, which can be changed using the arrow keys; when the time has been set, press the SET key to confirm. At this point the yellow LED lights up, the U.V. lamp is activated and the countdown starts. During the cycle the following message appears: U.V. TIMER U.V. Timer (min) xxxx 3-4 UP/DOWN ARROWS Use the arrow keys to scroll the menu, to program changing parameters and to put in the password. Two passwords are programmed: 1) to start the cabinet and to enter the operator menu 2) to enter the main menu to change the data input (allowed only to authorized technical staff service because unsuitable interventions can cause troubles and incorrect operation of the cabinet. If installed with the up/down arrows it is possible move the sash window 00112EN REV. 04 03/2013 9

5-6 LEFT/RIGHT ARROWS Use the arrow keys to scroll the menu: if pressed the following data will appear on the display: U.V. Lamp Residual Lifetime: Shows the operating time of the U.V.lamp pre-set by the user with the appropriate keys. The LCD will display (for example) "U.V. TIME=XXXX h". When such time is over, the message "U.V. LIFETIME OVER" will appear on the line below. 1, 2, 3 Residual lifetime of filters : it is the operation time of the filters installed in the cabinet that can be programmed by the user. The LCD will display (for example)" RES. TIME FILTER 1=XXXX:XX h:min". When such time is over, the message "CHECK FILTER (i.e.) 1". will appear on the line below. The filters installed in the cabinet follow the numbering listed below TYPE of FILTER NUMBER MAIN HEPA 1 EXHAUST HEPA 2 ACTIVE CARBON 3 LAF Power: it is shown indirectly by the power supply voltage of the motor, expressed as percentage of max. load voltage displayed also in proportion by a bar. The display shows the notice(es.): "MOT.LAF = XX % " (max.100%). Operating Time: Shows the operating time of the cabinet from the moment when the main switch is positioned on "I" The LCD will display (for example) "WORK TIME=XXXXXh. This value cannot be reset. 7 LIGHT This switches on the fluorescent light; when enabled, the display shows "Light on". Switching on the fluorescent light automatically the U.V. lamp switches off. 8 SOCKET This supplies voltage; when enabled, if the PCB for the automatic regulation is installed the display shows "POWER ON". The global current for all the sockets installed on the cabinet is 4 Amps. 9 GAS (optional) This activates the control for opening/closing the gas electrovalve; when enabled, if the PCB for the automatic regulation is installed the display shows "GAS ON". It operates only when the ventilation is running to prevent possible over-heating and risks of damaging the HEPA filter. 10 ESC ESC key deletes the operation of data input and goes back to the starting condition. When an alarm condition occurs, which is shown also by the message appearing on the LCD. By pushing "ESC" (if enabled) the alarm stops sounding. If the cause of the alarm is not resolved after 2 minutes the buzzer starts to sound again. 00112EN REV. 04 03/2013 10

11 SET SET key lets you enter the different functions or confirm the data input going back to the upper level. 12 LINE The green mains light switches on if the unit is connected to the mains and the line is live 13 DISPLAY Rearlight liquid crystal "LCD" display composed of 2 lines of 20 characters each showing the operating parameters and alarms. 14 ALARM When an alarm occurs the red LED lights up. 00112EN REV. 04 03/2013 11

4E. OPERATOR MENU It s possible enter the operator menu, with the cabinet in stand-by mode and when the cabinet is switched on, by pressing at the same time the keys ESC (7) and ARROW UP (6). If enter the operator menu while the cabinet is running, it s possible to set only the ALARM CLOCK and the TIMER. STAND-BY MODE PASSWORD ESC + UP arrow OPERATOR MENU Timer set up TIMER SET UP hh:mm OPERATOR MENU Alarm clock set up ALARM CLOCK SET UP Enable YES/NO ALARM CLOCK SET UP Date and hour OPERATOR MENU UV program UV PROGRAM Duration: hh:mm UV PROGRAM ON: Date and hour OPERATOR MENU UV residual time UV LAMP SET UP XXXX OPERATOR MENU Filter residual time SET FILTER 1 Set XXXX SET FILTER 2 Set XXXX SET FILTER 3 Set XXXX OPERATOR MENU Language LANGUAGE Italiano LANGUAGE English LANGUAGE Francais LANGUAGE Deutsch LANGUAGE Espanol OPERATOR MENU Set up the clock SET UP THE CLOCK Date and hour OPERATOR MENU Change Password CURRENT PASSWORD: Psw: SET UP PASSWORD: Psw: VERIFIY PASSWORD: Psw: OPERATOR MENU Alarms display 00112EN REV. 04 03/2013 12

U.V. LAMP RESIDUAL LIFETIME: use "UP/DOWN arrow" keys [5/6] to choice the desired menu select U.V. LAMP RESIDUAL LIFETIME. and press "SET" [10] key; the display will show: U.V. LAMP RESIDUAL LIFETIME set XXXX where XXXX shows the number of the hours set for lifetime of the U.V. lamp. Use the up and down arrow keys to adjust the hours parameter Then press the "SET" key [8] to confirm the data and/or go back to previous menu To conclude programming, press ESC [7] key. FILTERS RESIDUAL LIFETIME: use "UP/DOWN arrow" keys [5/6] to choice the desired menu select FILTERS RESIDUAL LIFETIME. and press "SET" [8] key; the display will show: FILTER 1 RESIDUAL LIFETIME set XXXX where XXXX shows the number of the hours set for lifetime of the FILTER 1 Use the up and down arrow keys to adjust the hours parameter Then press the "SET" key [8] to confirm the data and pass to filter 2 and so on up to filter 5 (as for relation between number and type of filter see table par. 4C) To conclude programming, press ESC [7] key. LANGUAGE SELECTION use "UP/DOWN arrow" keys [5/6] to choice the desired menu select LANGUAGE and press the SET key and the following message will be shown on the display: LANGUAGE English With the up and down arrow keys select the desired language (Italian, English, French, German, Spanish). Press the SET key to confirm and exit the LANGUAGE menu. press ESC [7] key to go out. 00112EN REV. 04 03/2013 13

SET UP THE CLOCK use "UP/DOWN arrow" keys [5/6] to choice the desired menu select SET UP THE CLOCK. and press "SET" [8] key; the display will show: SET UP THE CLOCK set XXXX Use the left and right arrow keys to select the desired parameter and set it using the up and down arrow keys Then press the "SET" key to confirm the data and/or go back to previous menu To conclude programming, press ESC [7] key. PASSWORD CHANGE use "UP/DOWN arrow" keys [5/6] to choice the desired menu select PASSWORD CHANGE and press "SET" [8] key; the display will show: CURRENT PSW: digit the present Password then press SET key digit the new Password then press SET key SET UP PASSWORD PSW: VERIFY PASSWORD PSW: digit the password again and then press SET key to confirm the data and/or go back to previous menu To conclude programming, press ESC [7] key. DISPLAY OF HISTORICAL FILES use "UP/DOWN arrow" keys [5/6] to choice the desired menu select ALARMS and press "SET" [8] key; use "UP/DOWN arrow" keys to scroll through the list of the possible troubles happened. The list is in chronological order and contains up to 64 voices To conclude programming, press ESC [7] key. 00112EN REV. 04 03/2013 14

ALARM CLOCK use "UP/DOWN arrow" keys [5/6] to choice the desired menu select ALARM CLOCK and press "SET" [8] key; the display will show: Alarm clock set up Set up XXXX Use the left and right arrow keys to select the desired parameter and set it using the up and down arrow keys Then press the "SET" key to confirm the data and/or go back to previous menu Press ESC to abort the procedure When the set time is reached the buzzer start to ring and the display show this message ALARM CLOCK ALARM Press the ESC key to silence the acoustic signal IMPOSTAZIONE TIMER use "UP/DOWN arrow" keys [5/6] to choice the desired menu select PASSWORD CHANGE and press "SET" [8] key; the display will show: Timer set up Set up XXXX Use the left and right arrow keys to select the desired parameter and set it using the up and down arrow keys Then press the "SET" key to confirm the data and/or go back to previous menu Press ESC to abort the procedure At the end of the countdown the buzzer start to ring and the display will show this message: TIMER ALARM Press the ESC key to silence the acoustic signal 00112EN REV. 04 03/2013 15

UV TIMER use "UP/DOWN arrow" keys [5/6] to choice the desired menu select PASSWORD CHANGE and press "SET" [8] key; the display will show: UV TIMER Duration XXXX Use the left and right arrow keys to select the desired parameter and set it using the up and down arrow keys Then press the "SET" key to confirm the data The display shows: UV TIMER DATE XXXX Use the left and right arrow keys to select the desired parameter and set it using the up and down arrow keys Then press the "SET" key to confirm the data and/or go back to previous menu 00112EN REV. 04 03/2013 16

5. HOUR COUNTER / UV TIMER (Optional) Available only in English language. 5A. Hours counter During the standard operating of the cabinet the display shows: The hour counter starts when the ventilation is switched ON and stop when the ventilation is turned OFF It is possible RESET the hour counter pressing in sequence the following keys: ESC Arrow down Arrow up SET After this the display will show this message: WORKTIME RESET Confirm? No Change the answer with the arrow keys and press SET 5B. UV Timer When the UV key is pressed on the display the following message will appear. Now with the arrow keys, it is possible set the time for the UV lamp; when SET is pressed the countdown starts and when it reaches 0:00 the UV lamp switches off (if the operator sets the time 0:00 the UV lamp still turned ON until the UV key is pressed again). If necessary press the UV key to switch off the UV lamp before the countdown reaches 0:00 00112EN REV. 04 03/2013 17

5C. Energy save The hours counter/uv timer PCB has the function: Energy save: When the cabinet is in Stand by mode, after few minutes the display switch OFF (only the green led still remain lighted). To switch on the display it is necessary press any key The functions of this PCB are available only in English language. 00112EN REV. 04 03/2013 18

6. DISPOSAL OF WASTES DISPOSAL OF ELECTRIC AND ELETTRONIC DEVICES (AEE) INFORMATION FOR EUROPEAN UNION USER This symbol on the device means that when it needs to be disposed, it must be handled separately from urban waste. At the moment of the disposal, contact the dealer, to receive information about the collect and disposal in accordance with the laws in force in the country. Appropriate disposal of this product will help to prevent potential negative effects on health and environment and to promotes re-use and / or recycling of materials of the equipment. The improper disposal of the product by holder involves the application of sanctions in accordance with the regulations in their own country. INFORMATION FOR USERS OUTSIDE THE EUROPEAN UNION This symbol is valid only in the European Union If you want to dispose this product, contact your local authorities or dealer and ask for the correct method of disposal. 00112EN REV. 04 03/2013 19

7. LIMITATIONS PRECAUTIONS for the correct use of the cabinet Listed below are the most important guidelines to be followed and the main substances to be avoided to ensure the correct use of the FlowFAST V cabinet: NEVER USE chlorine-based substances (e.g. sodium hypochlorite) as they are corrosive for the metal structure of the cabinet and in particular for stainless steel parts. NEVER MANIPULATE pathogens of any group or biosafety level. DO NOT use ethyl alcohol as a sterilizing substance if a heat source is used under the cabinet, DO NOT use cosmetic powders, nail-polish, hair-spray and cosmetics in general during work, DO NOT eat, drink or smoke in the working zone, AVOID substances that release explosive vapours. In addition, when working under the cabinet, AVOID: the introduction of extraneous material the introduction of paper/clothes that might clog the holes of the work surface working in the part of the work surface near the front opening of the cabinet (longitudinally slotted zone) upstream contamination of the material, putting the hands or an object between the absolute filter and the sterile material working under the cabinet if the airflow has not yet been activated, and a suitable work condition has been achieved. After the cabinet switching on and if the work requires sterile conditions, chemical sterilization of the work chamber must be carried out using a cloth soaked in bactericide. Then wait for 20 30 minutes for the bactericide to take effect. using in the work zone large size bunsen burners, as the flame might damage the absolute filter located in the upper part of the working area ATTENTION: The U.V. radiations emitted by the germicidal U.V. lamp can cause erythemas and conjunctivitis. AVOID EXPOSURE OF SKIN AND EYES TO DIRECT RADIATION 00112EN REV. 04 03/2013 20

8. OPERATING PROCEDURES 8A. PRELIMINARY CHECKS Before carrying out any type of work, the following conditions should be verified: - that the cabinet power cable is connected to a 230V-50Hz outlet (if not distinct voltages/frequencies are shown on the label stuck near the power cable) - that the work area inside the cabinet is free from materials used during the previous session - that the work chamber has been cleaned/sterilized. 8B. SWITCHING ON the FLOWFAST V CABINET To switch on the cabinet, proceed as indicated below: - Switch on the cabinet by pressing the key ON/OFF (if the PCB for the automatic regulation is installed insert the password: press the button 5, button 4 and then the button SET ) - Switch on the lighting, by pushing the key The cabinet is ready to work. Wait 5 minutes before starting any operation (see chapter 5). During this period of time, introduce ALL and ONLY the material indispensable for working in the internal working zone of the cabinet. 8C. SWITCHING OFF FLOWFAST V CABINET At the end of the work session, proceed as follows: - Remove the material from the internal work chamber - Clean the work surface and the inside walls of the chamber, as indicated in the Cleaning instructions (chapter 7A) - Turn off the light by pushing the key - Turn off the cabinet by pressing the "ON/OFF key (if the PCB for the automatic regulation is installed insert the password: press the button 5, button 4 and then the button SET )) or press the "SPEED REDUCTION" key In case UV lamp is installed in the cabinet, switch on the germicidal lamp by pushing the U.V. yellow button. The U.V. lamp will switch on only if the front aperture is closed with the relevant panel. 00112EN REV. 04 03/2013 21

8D. U.V. LAMP POSITION U.V. rays could damage the HEPA filter, when using the U.V. lamp be careful to don t place it too close to the main HEPA filter. In the picture is shown the correct position for the U.V: lamp. 00112EN REV. 04 03/2013 22

9. MAINTENANCE 9A. INSTRUCTION FOR DAILY CLEANING OF VERTICAL LAMINAR FLOW CABINETS (by users) or: Clean the outside of the FlowFAST V cabinet, made of stainless steel AISI 304, using a damp cloth soaked in alcohol or soapy water or some other commonly available products for stainless steel. Clean the outside of the FlowFAST V cabinet, made of varnished iron-carbon sheet steel, using a damp cloth soaked in soapy water or some other commonly available products for varnished metal surfaces. Clean-sterilize the internal work chamber with a bactericidal agent chosen according to the type of micro-organism manipulated (e.g., ethanol, phenolic compositions, aldehydes, quaternary ammonium salts, etc.). For efficient cleaning, spray the bactericidal agent on the side walls, the back wall and the perforated work surface. If material has been spilled during the work session, clean the work surface, then remove it using the small grips fixed on same, clean the spilled materials contained in the collection tank located under the table and remove all spilled material by means of absorbent paper. For thorough cleaning we suggest the use of a 70% ethanol solution or a solution of other bacteriostatic agents. N.B.: Never use solutions containing free chlorine (for instance, sodium hypochlorite), which cause corrosion to steel and stainless steel, resulting in irreparable damage to the cabinet structure. IMPORTANT: before carrying out the following operations of replacement, disconnect the cabinet 00112EN REV. 04 03/2013 23

9B. REPLACEMENT OF HEPA FILTER (by technical assistance personnel) For the safety of the personnel and the environment, the use of PVC gloves is recommended as well as the collection of the replaced HEPA filters in polyethylene bags. Replacement of main/exhaust HEPA filter (see guide-drawing for maintenance operations) 1. Switch off the cabinet and disconnect it from the mains 2. Open the control panel [1] unscrewing the bolts [2] with the proper key and lock it with the relevant stirrups. 1 2 Stirrup 3. Remove the internal panel [3] unscrewing the relevant fastening screws. 4. Rotate the threaded bars [4]and remove the central frame to release the HEPA filter [6]. Central frame 4 5. Remove the HEPA filter wearing PPD and put it in a hermetically sealed polythene bag. 6. Place the additional gasket (if it is not already present) on the filter shoulder frame opposite the shoulder gasket of filter (already present). 7. Install the new HEPA filter. 8. Lock the HEPA filter [6] by means of the threaded locking bars [4] Important: Having replaced the filters, proceed with the calibration of motor-fan speed, and perform also a control with a "light scattering" meter. 00112EN REV. 04 03/2013 24

Replacement of prefilter 1. Switch off the cabinet and disconnect it from the mains 2. Unscrew the screw of the frame to unlock the prefilter 3. Replace the prefilter 4. Fasten the frame with the screw 9C. REPLACEMENT OF MOTOR-FAN (by technical assistance personnel) 1. Proceed as indicated in sub-section "Replacement of HEPA filters", from 1 to 3 points. 2. Remove the frame [19] in front of the fan and release the textile plenum 10 15 17 11 3. Disconnect electrical connectors from terminal board in the plastic box. 4. Unscrew fastening screws [10] of the main motor-fan [11] and the flow sensor group [17] (optional) unscrewing the relevant stirrup from the motor-fan 00112EN REV. 04 03/2013 25

5. Remove the main motor-fan [11] including the side stirrup [12]. 12 11 6. Position the new motor-fan after having mounted again the flow sensor group (Optional) [15] and the relevant stirrup. 7. Fasten the motor-fan with the relevant screws and reconnect electrical connectors. 8. Proceed as indicated in the sub section "Replacement of HEPA filters", from 13 to 15 points. 9D. REPLACEMENT OF FLUORESCENT LAMPS (by user) 1. Open the front control panel [1] unscrewing the fastening locks [2], 2. Replace the lamps [16] 3. Close the front control panel [1] with the fastening locks [2]. 00112EN REV. 04 03/2013 26

9E. LIST OF SPARE PARTS CODE DESCRIPTION 12 15 18 V50 000000200 DDM 9/9 300W 1 V50 000000420 DDM 10/10 550W 1 1 V50 000100360 HEPA absolute filter, 610x1220x69 with laminator sheet 1 V50 000100370 HEPA absolute filter, 610x1525x69 with laminator sheet 1 V50 000100380 HEPA absolute filter, 610x1830x69 with laminator sheet 1 V50 000202010 Prefilter, 457x610x12 1 V50 000202020 Prefilter, 457x762x12 1 V50 000202030 Prefilter, 457x915x12 1 K60 011230900 Front upper glass 1 K60 011530900 Front upper glass 1 K60 011830900 Front upper glass 1 K60 011231000 Front lower glass 1 K60 011531000 Front lower glass 1 K60 011831000 Front lower glass 1 K60 011430800 Left side safety glass 1 1 1 K60 011431400 Right side safety glass 1 1 1 V30 000008000 Power card PWLAF 1 1 1 V30 000008100 CPU card CPULAF (optional) 1 1 1 V30 000005200 Keyboard 1 1 1 V20 000006900 Line filter FN2070A-10-06 1 1 1 V20 000006040 36W Fluorescent lamp 1 V20 000006050 58W Fluorescent lamp 1 1 00112EN REV. 04 03/2013 27

10. TROUBLESHOOTING Probable causes of malfunctions PROBLEM CAUSE REMEDY Cabinet does not work the electricity supply has been cut off at the mains Electronic board out of order Blown fuse(s) check the voltage input to the cabinet Replace PCB Replace fuses Alarm: HEPA filters check Main HEPA filter clogged Replace HEPA filter minimum LAF alarm. [Possible contamination of the product but protection of the environment] Black-out Alarm (probable exchange of air between the work chamber and the outside and possible contamination of the environment) HEPA filters clogged. The main motor-fan does not work Blackout Replace HEPA filters. Check the terminal voltage of the power card of the main motor-fan Check F7 fuse on the power card Replace the power card Replace the microprocessor card Check the feeding cable, the connection plug/socket, the power supply line Press ESC [7] key to silence the alarm Alarm Sensors failure Failure of sensor XX Replace XX sensor. Alarm: No encoder input LAF No signal from LAF flow sensor Replace the LAF sensor 00112EN REV. 04 03/2013 28

11. TRANSPORT, PACKING an STORAGE INSTRUCTIONS IMPORTANT: Disconnect power and sterilize the unit before performing any of the following operations The following instructions are essential if the end user needs to transport, pack and store a cabinet after a period of routine use (e.g. laboratory/plant moving): Disconnect tubes for gas/vacuum Remove the work surface and and cover it with a protective film. Open the two lock handles of the front safety glass If the cabinet is to be moved from a laboratory to another in the same building: - on a table with wheels: it is sufficient to put the cabinet on the table; do not place it on one side on the back panel. - by a forklift : put the cabinet on a pallet to ensure good stability and to protect the basin under the cabinet against damage in transport. Take care not to damage protruding parts (e.g.: gas/vacuum taps, exhaust duct) when passing through doors/windows If the cabinet must be kept temporarily unused at the final destination, cover the cabinet itself with a protective film (pluriball or expansible films) taking care to protect also the exhaust duct, especially from dusty We recommend extreme caution in long-distance moving carried out by forwarding agents (e.g. change of address): we suggest that you use the original packaging supplied by the manufacturer with the cabinet. 00112EN REV. 04 03/2013 29

Packaging characteristics: - Wooden pallets of the following dimensions: FlowFAST V12 142,5 x 87,5 x 12 cm FlowFAST V15 204 x 87.5 x 12 cm FlowFAST V18 204 x 87.5 x 12 cm - Cardboard base to be laid on the pallet of the following dimensions: FlowFAST V12 86 x 141.5 x 1 cm(thick) FlowFAST V15 86 x 202 x 1 cm(thick) FlowFAST V18 86 x 202 x 1 cm(thick) - Pluriball to wrap and protect the cabinet from dust - Cardboard outer package of the following dimension: FlowFAST V12 142 x 87 x 162 cm (1 cm. thick) FlowFAST V15 202,5 x 87 x 162 cm(1 cm. thick) FlowFAST V18 202,5 x 87 x 162 cm(1 cm. thick) - Steel strap and clips During transport take care to maintain the package in vertical position (i.e. the pallet at the bottom) The cabinet (with or without the package) must be kept in a place with the following environmental conditions : - Min. temperature: 0 C - Max. temperature: 70 C - Max. humidity: 90% 00112EN REV. 04 03/2013 30

12. ADDITIONAL INFORMATION 12A. GUARANTEE The guarantee for FlowFAST V P vertical laminar air-flow cabinets is 24 months from date of invoice. In addition to those cases specifically indicated in Chapter 5 relating to improper use of the cabinet, the guarantee offered by FASTER s.r.l. also excludes certain improper uses described in the instruction manual, of which the most important are listed again below: installation in a place which does not conform to the manufacturer s recommendations wrong power voltage bad earth connection use of chlorine or its derivatives, incompatible with stainless steels and/or varnished steel, for cleaning the cabinet, tampering or changes made by the client tampering with the cabinet using any type of tool improper connection between electrical outlet and the power cable, wrong connection between gas cock or electro-valve and gas mains 12B. ADDRESS OF TECHNICAL ASSISTANCE (for the distributor) 00112EN REV. 04 03/2013 31

13. DIAGRAM FOR MAINTENANCE OPERATIONS 13A. LEGENDA Ref. DESCIPTION 1 Control board panel 2 Control panel locks 3 Internal panel 4 LAF plenum tie-rod 5 LAF plenum 6 Main HEPA filter 7 Lamps 8 Work chamber 9 Work surface 10 Screws fixing Main motor-fan 11 Main motor-fan 12 Stirrup main motor fan 13 UV lamp socket 14 Socket 15 Frame 16 Prefilter 00112EN REV. 04 03/2013 32

13B. FlowFAST V P 00112EN REV. 04 03/2013 33

14. FRONTAL DIAGRAM 14A. FlowFAST V P FlowFAST V 12 FlowFAST V 15 FlowFAST V 18 A 1198 1503 1808 B 1350 1655 1960 00112EN REV. 04 03/2013 34

15. SIDE DIAGRAM 15A. FlowFAST V P 00112EN REV. 04 03/2013 35

16. SENSOR LIST PLUG Software name Description J4-CPULAF S0 Air flow sensor J3- CPULAF S1 Frontal glass J2- CPULAF S2 J3-PWLAF S3 Magnetic sensor for U.V. J2- PWLAF S4 Proximity switch for U.V. 00112EN REV. 04 03/2013 36

17. WIRING DIAGRAM 00112EN REV. 04 03/2013 37

00112EN REV. 04 03/2013 38

00112EN REV. 04 03/2013 39

00112EN REV. 04 03/2013 40

18. DECLARATION OF CONFORMITY The undersigned legal representative of the company Faster S.r.l. hereby declares that the follow products: are in compliance with the following directives: FlowFAST V 2006/42/EC 2004/108/EC 2006/95/EC Directive of the European Parliament and of the Council on machinery Directive of the European Parliament and of the Council on the approximation of the laws of the Member States relating to electromagnetic compatibility Directive of the European Parliament and of the Council on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits and with the following standards: ISO 14644-1 EN 61010-1 EN 61326-1 Cleanrooms and associated controlled environments: Part 1: Classification of air cleanliness. Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: general requirements Electrical equipment for measurement, control and laboratory use EMC requirements and, according to the above-mentioned directives, the CE IIA mark has been applied. The undersigned also declares that the person who is authorised to compile the relevant technical documentation is Mr.: Ing. Pietro Bascapè Faster S.r.l. Maria Giulia Turzi Chairman of the board 00112EN REV. 04 03/2013 41