INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

Similar documents
INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

ISLAND RANGE HOOD SPECIFICATIONS

INSTALLATION INSTRUCTIONS

UNDER CABINET RANGE HOOD SPECIFICATIONS

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

Viking Installation Guide

Viking Installation Guide

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

WhispAire Range Hood Quiet Hood

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE. By Vent-A-Hood

! FOR DOMESTIC COOKING ONLY!

NUTONE RANGE HOOD NTM SERIES

Hood. warning. warning. caution

Installation Instructions

Pro Island Ventilation Hoods

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

WhispAire Range Hood Quiet Hood

Viking Installation Guide

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

! FOR DOMESTIC COOKING ONLY!!

Installation. Professional Indoor & Outdoor Hoods

Model ND-2 Specification

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

Self-Cleaning Range Hoods

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments

Viking Installation Guide

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

All (-4) Models 390CFM Code Compliant

Type of Motor & Blower

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

Viking Installation Guide

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

www. TheRangeHoodStore.com

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Designer Wall Range Hood Installation. Installation Tutorial Video

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-XHD SERIES. TMI, LLC Managing Environments

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

HP190SL Series Slimline Radon Fans

FADE Series Wall Axial Fans

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

Filtered Kitchen Supply Packaged Ventilator

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

Viking Installation Guide

Installation Guide. Professional Indoor and Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

ceiling & inline/cabinet ventilators

CEILING & INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

IMPORTANT SAFETY INSTRUCTIONS

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

MODEL FF50 CEILING FAN

SQUARE INLINE CENTRIFUGAL FANS

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

KEES, INC. BALANCING MANUAL

VENTING & COMBUSTION AIR GUIDE

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:

ISLAND INSTALLATION WALL INSTALLATION

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

VENT FLASHINGS GALVANIZED STEEL

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

MODERN-AIRE. For the professional or the everyday gourmet, Modern-Aire Ventilating. Range Hoods

Safety & Installation Instructions

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

Transcription:

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including firerated construction. Switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally during installation. B. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. C. Ducted fans must always be vented to the outdoors. D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code authorities. E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to a maximum of 15 per 100 square feet of occupiable space, unless a back drafting test is performed or make-up air is provided. Consult a local HVAC engineer for make-up air evaluation. WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK Page 1 C U L R US

Ducting Do s and Don ts NEVER restrict the duct size. The K250 blower unit requires round duct or equivalent (32.5 square inches). Using Vent-A-Hood transitions (back page) will ensure proper efficiency. Blower Duct Size Sq. Inch Area K250 3 1/4 x rectangular or equivalent 32.5 Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance. Only use smooth, galvanized, metal duct. Observe local codes regarding special duct requirements and placement of duct against combustibles. Make the duct run as short and as straight as possible with as few turns as possible. Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree angled turns. For duct runs over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree elbow is equal to 5 feet of duct. Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. Airflow must not be restricted at the end of the duct run. Do not use screen wire or spring-loaded doors on wall louvers or roof jacks. Do not terminate venting into an attic or chimney. Where possible, seal joints with duct tape. The hood must be ducted to the outdoors without restrictions. YES Smooth Duct Smooth Gradual Turn NO Flexible Duct Sharp Angled Turns Page 2

Installation Details 1) Read all instructions thoroughly before beginning installation. 2) When installing the K-Series under cabinet hood, it is recommended that the bottom edge of the hood be located no more than 21-24 above the cooking surface for optimum performance. 3) Inspect the underside of the cabinet for a flush mounting surface. If the underside of the cabinet is recessed, install wood strips to provide a flush surface for the hood mounting screws to engage. 4) Determine whether the hood will discharge horizontally or vertically. The hood is shipped to discharge vertically but is easily converted to horizontal discharge by exchanging the discharge adapter on top of the hood (4 screws) with the discharge cover on the back of the hood (2 screws). Use duct tape to seal the discharge adapter and discharge cover to the hood. 5) IF THE HOOD IS TO BE BACK VENTED, PROCEED DIRECTLY TO STEP 6. Install the duct from the outside of the home down to the location of the hood exhaust outlet allowing room for the VP521 transition on the top of the hood (if applicable). If a VP521 transition is used, install the duct down to the location of the transition outlet plus 1. This will allow the transition to engage 1 inside of the duct. Consult the connection diagram (below) for further details on exhaust outlet placement. Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is provided on the back page of this instruction sheet. Transition height: 3 1/4 x duct will connect directly to the exhaust outlet of the hood. Optional VP521 transition to round (sold separately) is 7 1/2 tall. Ceiling Cutout for Vertical Ducting ed from Above " 3 ½" of Cabinet 2 " 5 " 5 " C L 6 ¼" Electrical Page 3

Installation Details Continued 6) Remove the hood from its packaging and place on the floor or countertop in front of the cabinet where it will hang. Warning: Make sure power is off and locked at the service disconnecting means on the service panel during installation. 7) Determine whether the electrical wire will enter from the top or the back of the hood. Remove the electrical enclosure cover (1 screw) and the top or back electrical enclosure knockout from the hood. Install an appropriate 1/2 UL listed electrical wire clamp through the electrical knockout. Install electrical wiring from the electrical panel to the hood location. Model Volts Amps Hz RPM SP@0.0" Equivalent SP@0.1" SP@0.2" SP@0.3" Minimum Round Duct Size K250 (Top Vent) 115 3.2 60 1550 250 375 223 220 190 7" (38 in. 2 ) 7.4 K250 ( Vent) 115 3.2 60 1550 220 330 196 194 167 7" (38 in. 2 ) 7.4 Because the Magic Lung blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung blower can handle cooking equipment with higher cubic feet per minute () requirements and can deliver equivalent much more efficiently than other than other filtration systems. When comparing the Magic Lung with other blower units made by other manufacturers, use the Equivalent. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. 8) Insert the electrical wire through the electrical wire clamp allowing 3-4 of wire inside the enclosure for hookup. Tighten the electrical wire clamp. 9) From inside the hood, using UL listed wire nuts, attach the neutral wire to the white lead, the hot wire to the black lead, and the ground wire to the green lead inside the junction box. Replace the electrical cover previously removed in Step 7. Sones # Warning: Do not operate hood without proper ground connection. 10) FOR BACK VENTING APPLICATIONS ONLY. IF YOU ARE NOT BACK VENTING, PROCEED DIRECTLY TO STEP 12. Note: Wall studs may interfere with back venting installations. Additional framing may be required. It is necessary to cut a duct access hole in the wall prior to installing the hood. Starting 2 1/ above the bottom edge of the hood, cut a hole 3 1/2 high x 10 1/4 wide (see diagram at right). 11) Install the duct from the outside of the home to the duct access hole in the wall. Where possible, use duct tape to seal joints. Wall Cutout for Horizontal Ducting ed from Front " 3 ½" Bottom of Cabinet 1 " 12) While aligning the duct and guiding the wires, position the hood under the cabinet. The duct should connect together as the hood is located in place. Note: Unless using the VP521 transition, the duct work must fit inside the exhaust collar. If using the VP521, round duct should be placed with the noncrimped end on the outside of the collar of the VP521 exhaust outlet. Using the four screws provided, attach the hood to the bottom of the cabinet. 5 " 5 " C L 6 ¼" Electrical 14) Refer to the Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light functions to ensure they are operating properly. Page 4

VENTING ACCESSORIES RECTANGULAR 8 5 13 13 1 ½ FLANGE 2 FLANGE VP526 VP527 VP528 Round Round Round (MAXIMUM 4/12 PITCH) VP554 Round (MAXIMUM 4/12 PITCH) VP555 Round (MINIMUM 4/12 PITCH) VP538 x 8-1/2 VP560 3-1/4 x (MINIMUM 4/12 PITCH) 6 ½ 22 ½ 6 ½ 22 ½ 20 ¾ 20 ¾ VP539 VP540 VP541 ADJUSTABLE ELBOW VP513 - VP514-9 9 1 VP515-10 5 Round Round Round VP552 VP553 Round Round BACK/SIDE VENT ELBOW VP539-HP VP540-HP VP541-HP x BACK VENT ELBOW 4 ¼ Round Round Round 14 VP552-HP VP553-HP Round Round x TO TRANSITION 7 ½ Round 1 VP513 VP514 VP515 Round Round Round MULTI-BLOWER TRANSITION VP561 to x 8-1/2 M1200 STANDARD TRANSITION VP559 3-1/4 x STANDARD ISLAND TRANSITION VP521 3-1/4 x 10 to CLUSTER BLOWER TRANSITION VP562-17 ½ VP563-16 ½ 9 9 11 ¼ VP562-2 VP563-30 ½ VP562 & to VP563 & to VP566 21 M1200 Transition VP565 1 5 5 x 1 to Rnd 1 VP564 & to OFFSET L & R TRANSITION FOR ISLAND BLOWERS SIDE VENT TRANSITION L & R FOR ISLAND BLOWERS 19 OFFSET KIT - ROUND OFFSET KIT - RECTANGULAR VP542 VP543 1 5 Top Left Top Right VP544 VP545 1 5 Side Left Side Right VP529 1 Rnd to Rnd 1 VP550 to 3-1/4 x Y TRANSITION ROUND DUCT PIPE RECTANGULAR DUCT PIPE RECTANGULAR DUCT PIPE 1 3 30 1 24 VP517 & to VP518 & to VP551 & to VP500 VP501 VP502 Round Round Round VP504 3-1/4 x VP505 3-1/4 x VP506 3-1/4 x 1 VP507 x 8-1/2 Page 5