IDENTIFICATION ACCESSORIES DESCRIPTION

Similar documents
(UK) Date : January 2014

Sentry. Door Curtain. Energy efficient EC motors Cased and concealed models LPHW and electric heating Comprehensive range of controls

Warning. Document ref: A October 2015

Aerocourse Fan Assisted Trench Heating

Features: Available in horizontal and vertical units

Ocelot vertical fan coil unit

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

COMFORT AIR CURTAIN. SensAir

Aerocourse. Fan Assisted Trench Heating

INHERENTLY QUIET AND POWERFUL 180 MM DEEP SLIMLINE HORIZONTAL WATERSIDE CONTROL IN CEILING

COMFORT AIR CURTAIN. SensAir

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.


TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

Technical Sales Guide # 040 YDFC 0 1 Page 2

ACPSB-P Series 60Hz. Rooftop Units Cooling Capacity : 30 to 1360 MBH (9 to 398 kw) R22 R407C. Products that perform...

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Highline 260i EC Waterside Fan Coil Unit

CENTRIFUGAL FAN COIL UNIT VCE

technical catalogue tetris KW Chiller and heat pumps air/water

C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Air-Cooled Liquid Chiller with integrated hydraulic module

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Fan Coil Units POWERED BY KLIMAK ITALY

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

CHILLED WATER FAN-COIL UNITS

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

COMFORT AIR CURTAIN. SensAir

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Air Cooled Packaged Units

University of Delaware

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

The Clima Canal is quiet even at high outputs, making it a discreet and effective heater for almost any situation

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Performance. Sound Levels. Impellers. Motors. Accessories

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Standard features. Optional features

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

CHILLED WATER DUCTED FAN COIL

Standard features. Optional features

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

THERMOSCREENS AIR CURTAINS

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

Ductable water unit FWD UNT-PRC002-E4

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

RCD Air Cooled Condensing Unit (50/60 Hz)

Ceiling swirl diffusers with perforated face plate

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

PHV V NT VERTICAL AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

R-22, 13 SEER 60 Hertz

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

The World Leading Air-conditioning Company

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

MODULAR AIR HANDLING UNITS GAH SERIES

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

D M S 760 C01 A A 1 1

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

BOX BLB Centrifugal Box Fan

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

Ceiling swirl diffusers

ISEO IMF Product Brochure

GUIDE SPECIFICATIONS. ES Series R-410A

For installation into ductwork

TECHNICAL SPECIFICATIONS WSH2BF

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

High Static Fan Coil Units YDFC

Multi directional heating. Air heaters Model NOZ

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

KLIMA Active Chilled Beams

Transcription:

Sentinel Doorway mounted air curtain. 1000mm, 1500mm & 2000mm widths. 1800 to 2700mm mounting height. Soffit drop rod or wall bracket mounted. Ambient air, 3 phase electric or LPHW heating. 1

IDENTIFICATION Introduction The Dunham-Bush Sentinel air curtain is an ideal solution to the ingress of cold air due to open doorway trading in retail premises, or busy pedestrian traffic in commercial and public buildings. The technology of air curtains is well proven. The vertical air stream above an open doorway provides a virtual barrier, which separates indoor and outdoor environments. This air barrier prevents inversion due to different air temperatures; thus reducing energy consumption, increasing internal comfort and usable floor area and will have no effect on pedestrian traffic flow. Sentinel air curtains are designed and manufactured to the high quality synonymous with Dunham-Bush products, complemented by a wide range of options to suit most applications. DESCRIPTION Range Sentinel air curtains are available in a range of models, for ambient, LPHW and electric heating. Each model is available in three sizes; Figures 10, 15 & 20 Model Overall Length (mm) Heating option Nominal Duty (kw) 270-A-10 1113 Ambient N/A 270-A-15 1621 Ambient N/A 270-A-20 2121 Ambient N/A 270-E-10 1113 Electric 9.0 270-E-15 1621 Electric 13.5 270-E-20 2121 Electric 18.0 270-W-10 1113 LPHW 9.5 270-W-15 1621 LPHW 14.1 270-W-20 2121 LPHW 22.6 ACCESSORIES Sentinel air curtains are supplied with a wall mounting bracket and the remote switching control box. Control options offered as standard are:- Switches On/off switch, and high/low fan speed adjustment switch. On 3 phase electric heating models the high/low switch automatically selects the full and 1/2 power heating settings. Electric Heating Element On electric heating element units, there are high temperature cutouts with both automatic and manual reset, located on the top of the casing. Wall Hanging Bracket All models come complete with a hanging plate for fixing to a vertical wall surface. Special controls Control options can be offered for remote installation to Sentinel air curtains, such as remote switches, relays, door interlocks and group control to suit particular applications. For further details contact your Dunham Bush representative. Simple user controls Note: All model 270 air curtains are suitable for doorway heights between 1800mm to 2700mm. Sentinel air curtains comprise motor, tangential fan(s), optional LPHW coil or black bar electric heating elements and electrical connection box. Wall hanging bracket All models are coated in durable polyester powder, colour white (RAL9010 30% gloss) with a satin finish. Soffit drop-rod mounting Wall hanging bracket Easy and quick installation with the wall hanging bracket or drop rods 2

PERFORMANCE Model 270 A-10 A-15 A-20 E-10 E-15 E-20 W-10 W-15 W-20 Width (mm) 1113 1621 2121 1113 1621 2121 1113 1621 2121 Height (mm) 254 254 254 254 254 254 254 254 254 Depth (mm) 265 265 265 265 265 265 265 265 265 Dry mass (kg) 16.4 19.8 24.6 19.6 25.4 31.9 19.9 24.4 30.4 Maximum discharge height (m) 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 Maximum door width (m) 1.0 1.5 2.0 1.0 1.5 2.0 1.0 1.5 2.0 Maximum air velocity (m/s) 9 9 9 9 9 9 8 8 8 Rated current (A) 0.8 1.1 1.1 40.0 60.0 79.0 0.8 1.1 1.1 Supply (v) 230V/1ph/50Hz 400V/3ph/50Hz 230V/1ph/50Hz Air volume flow rate (m3/h) Air volume flow rate (l/s) Heat output (kw) Air off temperature ( C) (with air on temprature 18 C) LTHW mass flow rate (kg/s) (80-70 C F&R, 18 C Amb) LTHW coil pressure drop (kpa) SWL dba re 1pW SPL* db re 2 10-5Pa Low 1242 2592 3708 1444 2441 3834 1346 1901 3463 High 1818 2736 4158 1879 2617 4100 1678 2218 3737 Low 345 720 1030 401 678 1065 374 528 962 High 505 760 1155 522 727 1139 466 616 1038 Low - - - 4.50 6.75 9.00 8.20 12.70 21.60 High - - - 9.00 13.50 18.00 9.50 14.10 22.63 Low - - - 27.4 26.3 22.7 36.2 37.9 36.6 High - - - 32.4 33.5 31.2 34.9 37.0 36.1 Low - - - - - - 0.196 0.303 0.516 High - - - - - - 0.227 0.337 0.540 Low - - - - - - 1.1 3.1 7.8 High - - - - - - 1.5 3.7 8.5 Low 43 51 52 47 55 56 45 53 53 High 56 60 59 55 59 57 54 58 56 Low 38 46 47 42 50 51 40 48 48 High 51 55 54 50 54 52 49 53 51 Table 1: Selection and Performance Data * Sound pressure level measured in a hemispherical free field at a distance of 3m from the door curtain. Notes 1) Air volume flow rates estimated for figures 15 and 20 of all variants at both speeds. 2) SWL and SPL for figures 15 and 20 of ambient (-A) and LTHW coil (-W) variants at both speeds. 3

DIMENSIONS Air curtain dimensions - LPHW & Ambient models Air curtain dimensions - electric heating models 4

FEATURES Electrical connection block Cable entry point LPHW coil 3/4 BSP femail connections Hi-temp cut-out manual reset LPHW coil Fuse 3 phase power relays Electrical compartment Tangental fan assembly Return air grille and outer casing Supply air grille Electric heating element Air curtain features Electrical connections box LPHW coil connections 5

ENGINEERING SPECIFICATION General The Sentinel air curtain shall be manufactured by Dunham-Bush Ltd, Downley Road, Havant, Hampshire, PO9 2JD. The models, figure numbers and quantities shall be as indicated in the schedule and /or on the drawings. The construction of all air curtains shall comply with the following specification. Basic unit Each Sentinel air curtain shall comprise of a sheet metal casing with access panel, heating coil/electric element, motor/fan assembly. Hot water coil (optional) When specified, hot water heating coils shall be provided. Coils shall be constructed from 9.35mm O.D. drawn copper tubes, expanded into single plate corrugated aluminium fins and brazed to copper headers. Flow and return connections shall be Rp3/4 to BS EN 10226 (3/4 BSP parallel female). Coils shall have a minimum cold test pressure of 16bar gauge. Coils shall have a maximum working pressure of 12bar gauge and a maximum flow temperature of 110 C. Electric heating elements (optional) When specified, electric heating elements shall be rated at 400V/3ph/50Hz, supplied from a TP&N fused electrical supply and shall be configured to give the design output specified. A self-resetting high limit thermostat set to operate at 50 C shall protect each element circuit and a manual reset thermostat set to operate at 60 C shall also protect each element circuit. The manual reset is located on top of the casing. Fan assemblies Fans shall be cross flow tangential type with low noise, forward curved, multi blade aluminum impellers housed in aluminum scrolls. Fans shall be statically and dynamically balanced. Motors Motors shall be high efficiency, with permanent split capacitor starting and run. Each motor shall have overload protection by way of auto re setting thermal contactors integrated into the motor windings. Motors shall have a nominal rating of 80, 100 & 120W and suitable for a 50 Hz single-phase electrical supply. Electrical connections box Each unit shall be provided with an electrical box. The box shall contain a terminal block for connection to the external supply and remote switchs. Fan motor speed control Speed control shall be affected by means of a switch providing two main speeds to suit the unit duty requirements. Packaging Each Sentinel air curtain shall be individually packed in cartons and shall be marked with the model, figure number and serial number. Accessories If specified, accessories listed in the manufacturer s Product Catalogue shall be provided. 6

CONSTRUCTION Handling The purchaser is responsible for off loading. Two people can usually lift individual air curtains. When a significant quantity is delivered, they may be palletised, so a forklift truck, or similar form of lifting equipment, is recommended. Care should be taken to ensure the units are not dropped or suffer impact in any circumstances. Storage Sentinel air curtains should be stored under clean, dry indoor conditions, and any packaging should not be removed until they are ready for installation, unless damage in transit is suspected. Note - the purchaser must examine the air curtains promptly upon receipt, and any claims for damage will only be accepted, if at the time of delivery the delivery note is endorsed with a note detailing the damage and countersigned by the transport company. Each air curtain may be marked with a stencil reference if specified on the order. Preparation Extensive modification to the building fabric should not normally be necessary. The structure, to which the unit is to be fixed, and fixings must be capable of accepting the loads imposed by the unit and the fixings selected must be suitable for the building fabric. Installation Sentinel air curtains are supplied with a copy of the Installation, Operation & Maintenance Instructions, which provide full details for installing, connecting and commissioning the unit. Additional copies are available upon request, or can downloaded from www.dunham-bush.co.uk. Pipework Connections (LPHW) Connections to the mains shall be Rp3/4 to BS EN 10226 (3/4 BSP parallel female) and shall be left handed (when facing the door curtain air inlet). Electrical Connections (Ambient Air and LPHW) Sentinel air curtain requires a 230V/1Ø/50Hz electrical supply. The electrical supply is connected to the air curtain via the terminal block. Electrical Connections (Electric heating) Sentinel air curtain with electric heating element requires a 400V/3Ø/50Hz TP&N electrical supply. The electrical supply shall be wired by others via Ø25mm holes in the casing to the terminal block. Cable strain relief is recommended e.g. with proprietary cable glands. PRICES & CONDITIONS OF SALE Prices Dunham-Bush do not issue price lists, but will be pleased to provide a written quotation upon request. All quotations are normally prepared through our Applications Department. For further details, please contact Dunham-Bush Ltd Head Office in Havant, Hampshire. Conditions of Sale Standard conditions of sale are included on the reverse of all Order Acknowledgements. Further copies are available upon request. SUPPLY Availability Sentinel air curtains are supplied direct from the Dunham-Bush factory in Havant. Availability can vary with demand and should therefore be checked at the time of ordering. Contact a Dunham-Bush Representative for typical lead times. Packaging Sentinel air curtains are packed for storage in dry, indoor conditions. If specified, each unit will be marked with its own unique stencil reference for onsite identification. Delivery Sentinel air Curtains are delivered to site in accordance with our Conditions of Sale. The buyer is responsible for off-loading and storage. TECHNICAL SUPPORT SERVICES Product Support In the United Kingdom and Ireland, Dunham-Bush has a network of Representatives situated at strategic locations, to provide local support on pricing and selection. Further technical support is available at the Dunham-Bush Head Office. Tel. 023 9247 7700 email info@dunham-bush.co.uk Colour All models are finished in polyester powder, RAL9010 white, 30% gloss level. Special colours and finishes are available, details can be provided on request. 7

BS EN ISO 9001: 2008 Manufacturer reserves the right to change any product specification without notice Dunham-Bush Ltd Downley Road Havant Hampshire PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 Email: info@dunham-bush.co.uk www.dunham-bush.co.uk 228-000-000-A May 2017 8