FUEL FLOW SENSOR INSTALLATION GUIDE

Similar documents
RDAC X. Technical installation document

EFMS100 USER MANUAL Revision 1.1

M SERIES Multi-Jet Cold Water Meter

MODEL 200 MULTI-JET FLOW METER

RDAC X. Technical installation document

MODEL 1100 TURBINE FLOW METER

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

FF-1. Introduction. 1 Features. Fuel management computer for single or dual fuel tanks. Operating Manual English 1.04

RDAC VD. Technical installation document

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

MODEL 900 IMPELLER-TYPE FLOW METER

Model 1100 Turbine Flow Meter

CHAPTER 12 SERVICING. Section Title Page

Operation and Maintenance Manual

TX 115/215 Hot-tap Insertion Turbine Instructions

Fuel Tank and Lines Fuel Delivery System Component Location Item Part Number Description

INSTRUCTION MANUAL. Smart Pressure. Variable Pressure Diagnostic Smoke Machine. with UltraTraceUV Non-Contaminant Dye Solution Model No.

MODEL 200 MULTI-JET FLOW METER

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

Turbine Flow Meter Series Turbine Meter USER MANUAL

MODEL 1100 TURBINE METER REPAIR KITS

Describe the function of a hydraulic power unit

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

Liquid Turbine Flow Meter OwnerÊs Manual

TX101/201 Insertion Turbine Instructions

IOM IR-910M0-X. Hydrometer Magnetic Drive with solenoid control

TX115/215 Hot-tap Insertion Turbine Instructions

ZEECO BURNER DIVISION

FF-3. Introduction. Fuel management computer for single or dual fuel tanks. Operating Manual English 1.02

Table of Contents Illustrations

Evaporative Emissions

Model TUR-200D Turbine Flowmeter

MULTI-JET WATER METERS

Series TTMP PVC Electronic Totalizing Meter

Geo-Prime Tank. Table of Contents. Installation, Operation & Maintenance Instructions AFCG1PT Revision: 7/3/14. Replacing a Pump 12

How to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1

Signet 2517 Brass Paddlewheel Flow Sensor * *

MGL Avionics EFIS G2 and iefis

丹东市德鼎工贸科技有限公司 Dandong DDTOP Manufacture & Trade Technology Co., Ltd. D--sensor D1-- rectifier D2 vane wheel D3--wire

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Flow Control Valve IOM 770-U

FLOW METERS FOR MINING

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

OVAL GEAR METERS MANUAL

Sidel Therm & CO 2 Counter Instruction & Installation Manual

Installation Guide for the Header Tank Automatic Fill Relay. (model: HTAF2)

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

Commander IS0128 ISO128E ECR# /04. Tachometer/ Engine Hourmeter

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

SIGNET 7002 Vortex Flow Sensor ENGLISH

Section 3 Technical Information

Vickers. Overhaul Manual. Vane Pumps. Small and Large Series Combination Pumps VC(K)(S)-**-(*)*D*-6(1) VC(K)(S)-**-(*)-*-*D*-5(1)

A1 Commercial Grade Meters

SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions

FM 3. FM 3 with Bypass. Materials and Specifications. Fire Service Meter with Bypass Sizes 3, 4, 6, 8, 10. Features

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

TECHNICAL SERVICE BULLETIN: TSB

TX101/201 Insertion Turbine Instructions

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

DVFP Series Variable Frequency Drive - Product Manual. pg. 1

Owner s Manual. IS0250a. ecr7106 9/2007

Internal Combustion Engines

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

SmartCone Differential Pressure Flow Meter User Manual

Digital III Fueling Vehicle Control System

TROUBLESHOOTING FLOW CHARTS

Industrial OG meter series IOG Inline and flanged oval gear meter

QuickServe Online ( ) ISB6.7 CM2350 B101 Service Manual

INSTALLATION AND OPERATION

PSF50 Paddle flow switch

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

Instruction Manual HMP TURBINE FLOWMETER. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

ADTFM-im -issue INSTRUCTION MANUAL DIGITAL DIESEL METER ADTFM

CHAPTER 18 WEIGHT AND BALANCE

TOPAS PMW-basic. Customer benefits. Product features

First Responder Guide: CNG and LNG Vehicle Fuel Systems

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

Model MVR. Model MVR. Materials and Specifications. Magnetic Drive Vertical Turbine Meters Sizes 3/4", 1", 1-1/2", 2", 3", 4" and 6" Features

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

To ensure proper installation, digital pictures with contact information to before startup.

TRIPLE FOAM INSTALLATION MANUAL Part # FOAMSTRMRTPL00X

TURBINE METERS - WP Series

Geo-Prime Tank U.S. Patent Number 8,544,282

Fuel level sensors Strela - Users manual. Fuel level sensors Strela. Users manual

Installation and Service Instructions 1018, 1020, 1022, & 1024 Size Pumps

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

"F" SERIES (Cont.) AIR FILTER ASSEMBLY NOTE NOTE. To remove grasp the cover, loosen snap and. If engine is flooded, fuel can drain back into

/.4=111. Lubrication Systems 6-23

Overview. Selection of System Components VT BBK/CWH. Chart LNG Vehicle Tank and Fuel System Installation Guidelines

DTC P1431 Fuel Level Sensor 2 Performance

Transcription:

Table of content FUEL FLOW SENSOR INSTALLATION GUIDE Revision 1 1 Features... 1 2 Installation... 2 2.1 Overview... 2 2.2 Fuel compatibility... 2 2.3 Ranging jet... 3 2.4 Flow direction... 4 2.5 Location... 4 2.6 Fuel filter... 4 2.7 Reservoir... 4 2.8 Orientation... 5 2.9 Mounting... 6 2.10 Magnet / Magnetic fields... 6 2.11 Connecting the sensor to the sender unit... 7 3 Calibration... 7 4 Important... 8 Revision history Revision Changes Date 1 N/A Sept. 2011 Acronyms FF GPM LPM Fuel Flow Gallon (1 US liquid Gallon = 3.785 liters) Per Minute Liter Per Minute

1 Features Using a fuel flow sensor enables EFMS100 system to provide the following information: Fuel flow Fuel used Fuel onboard Time to tank empty Distance to tank empty (after entering your speed) 2 Installation The fuel flow sensor is a precision instrument which requires careful installation to provide accurate information. 2.1 Overview To measure the fuel flow, the sensor should be inserted in the fuel line between the fuel tank and the carburetor of the engine. At the heart of the sensor is a precision turbine that rotates freely on robust sapphire bearings. Chemically resistant ceramic magnets that are detected through the chamber wall by a Hall Effect detector (magnetic field detector). Fuel from tank Fuel to engine 1.8 meters (6 feet) cable Wires to sender unit 2.2 Fuel compatibility It is your responsibility to ensure that the fuel you intend to use is compatible with the fuel flow sensor. After several years of continuous test we have found that EFMS fuel flow sensor is very compatible with automotive fuels, many of which contain methanol. 1 2

2.3 Ranging jet The sensor is delivered with 4 raging jets. Depending on the fuel flow range of your engine, a jet must be inserted in the sensor. Jet Diameter (hole) Flow Range: Liter Per Minute Flow Range: US Gallon Per Minute 1mm 0.05 0.5 0.013 0.13 2mm 0.1 1.5 0.026 0.4 3mm 0.15 4.5 0.039 1.2 4mm 0.18 6.5 0.047 1.72 No jet 0.2 10 0.052 2.64 Please ensure that the correct jet size is selected before installation as once inserted, the removal of the jet may damage the sensor. 2.4 Flow direction The sensor must be inserted in the fuel line so that the large arrow on the sensor matches the direction of the flow. 2.5 Location The best location for the sensor is a low as possible near the fuel tank. Placing the sensor as low as possible will avoid cavitation of the fuel. Cavitation is the formation of vapor bubbles of a flowing liquid in a region where the pressure of the liquid falls below its vapor pressure. Cavitation should be avoided as it will cause inaccurate flow measurements. Since the pressure in the fuel line decreases with the height, it is important to place the flow sensor as low as possible. We recommend placing the sensor below the top of the fuel tank. Placing the sensor near the tank (therefore far from the engine) will minimize the pressure (/flow) pulses caused by the carburetor (/fuel pump). Pressure pulses must be minimized as they will cause inaccurate flow measurements. Insert the jet in the input side of the sensor 2.6 Fuel filter A fuel filter must be inserted between the tank and the sensor to prevent dirt or debris to reach the sensor. These will not block the fuel flow but may lead to the turbine wheel inside the sensor jamming. Use the flat end of a drill bit of suitable diameter to push the jet all the way to the stop. This requires a bit of force. 2.7 Reservoir A small reservoir must be provided between the flow sensor and the carburetor/fuel pump. The reservoir can be a primer bulb or a long fuel line. The reservoir will minimize the pressure (/flow) ripple (/pulse) caused by the carburetor (/fuel pump) and will provide optimal performance of the sensor. 3 4

2.8 Orientation 2.8.3 Summary 2.8.1 Vertical axe For optimal performance (in particular at low flow rates) the axe of the turbine must be almost vertical. ENGINE (CARBURETOR/PUMP) TURBINE AXE FILTER TANK SENSOR RESERVOIR 2.8.2 Bubbles Please ensure that no bubbles can be trapped inside the sensor. Bubbles will cause inaccurate flow measurements. The best way to avoid bubbles inside the sensor is to allow bubbles to escape. This is done by pointing the outlet slightly upwards and the inlet slightly downwards. 2.9 Mounting The flow sensor is a precision instrument which must be isolated from vibrations. VERTICAL AXE 2.10 Magnet / Magnetic fields IN OUT The sensor contains 3 magnets which are part of the turbine wheel assembly. The magnetic field generated by these magnets is used to measure the flow rate. It is important to mount the sensor far from strong magnetic fields. For the same reason, the fuel line on the OUT side (towards the engine) should go up immediately after the exit of flow sensor. 5 6

2.11 Connecting the sensor to the sender unit The 3 wires at end of the cable must be connected to EFMS sender unit. Wire Function Terminal on sender unit Shield Ground GROUND Red Power provided by the +VPWR OUT sender unit to the fuel flow sensor Blue Signal from fuel flow sensor to sender unit FLOW IN 3 Calibration Refer to EFMS100 user manual for the description of the calibration procedure. 4 Important Note to Pilots Always have a visual indication of the fuel level available, either by means of a sight glass, direct tank observation or a known, reliable secondary fuel level gauge. Fuel level indication by means of calculated fuel burn is subject to errors both by entering incorrect starting fuel levels as well as mechanical problems causing the flow sensor impeller to turn too slowly, resulting in under reading fuel burn and thus over reading remaining fuel. As pilot in command of an aircraft it is your responsibility to ensure that you have sufficient fuel to reach your intended destination. Always ensure that you have a generous amount of reserve fuel and never use your reserve fuel except in an emergency if it is unavoidable. The calibration procedure should provide a PULSE/VOLUME RATIO within +/-5% compared to the values provided in the table below. If the value you calculate with the calibration procedure is far from the value provided by the table below, it means that the flow sensor is not installed properly. NOMINAL (i.e. APPROXIMATIVE) values of PULSE/VOLUME RATIO Do not use these values but instead, use the calibration procedure to calculate the correct value. Jet Pulses per Liter Pulses per US Gallon Diameter (=Pulse per Liter x 3.785) (hole) 1mm 17000 64345 2mm 7000 26495 3mm 3500 13247 4mm 2100 7948 No jet 1420 5375 7 8