Low cost, internally bypassed non optimizing soft starter

Similar documents
DFE. Fairford low cost, internally bypassed non-optimizing Soft Starter

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Dimensions WxHxD [mm] Weight [kg]

SOLSTART Instruction Manual

Fairford Electronics Product Selector

Game changing soft starters

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

ACCESS Always replace the cover panel on the unit after gaining access to the electrical connections.

MCD 200 Series Soft Starters

HIB Enclosed Inverter User Guide

Open Chassis Star-Delta Starter User Guide

Softstarters Softstarters

RVS-AX Instruction Manual

Guide to contents - applicable to

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

Reduced Voltage Motor Starters

Design Guide. VLT Soft Start Controller MCD 100

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Synergy EN product information

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

SDS Enclosed Star-Delta Starter User Guide

Soft Starters and Energy Optimising Soft Starters Guide to contents - applicable to

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Reduced Voltage Motor Starters

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Thyristor Power Controllers for Resistive and Inductive loads (Product Code 21.3)

1.1. Reduced Voltage Motor Starters

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

PCS compact soft starters

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

AuCom - Soft Starters

Motor Starting Solutions Open Type Version, in Kit Form

RVS-DX Digital Reduced Voltage Motor Starter

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

Industrial Chargers and

RVS-DN Digital Reduced Voltage Motor Starter

Technical Information

Application Description

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Installation Manual for DC Injection Brake Units

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

The High Power Stack Horizon

TECHNICAL DATA SHEET KVA UPS Systemss

Softstarters Type PSS. Softstarters. General information

a revolution in soft start motor control The future of soft start motor control at your fingertips

The future of soft start motor control at your fingertips

Reduced Voltage Motor Starters

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

MX431 Generator Automatic Voltage Regulator Operation Manual


Softstarters PSR PSS PST Extreme duty

D509E. Manual Motor - Starters

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

1.1 Caution Statements

Technical Data Sheets

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

PC T8 TEC, W PC TEC

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

a revolution in soft start motor control The future of soft start motor control at your fingertips

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

Start-up instructions

Short form catalogue. Motor protection & control

SECTION MOTOR CONTROL

PRODUCTS: POWER SUPPLY

Power Supplies PSS Series

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Features and Benefits. Control Features

Features and Benefits

Power Switching Devices

MGE Galaxy 5500 Marine

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Thermal Overload Relays

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

ABB component drives ACS150, 0.5 to 5 Hp

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

Defining a timer in simple terms. Which actions are executed? Which market are they used frequently? Benefits and Advantages

Technical Data Sheets

ELECTRONIC SOFT STARTER

Transcription:

Robust General Purpose Low Voltage Soft Starters Low cost, internally bypassed non optimizing soft starter 15.5 500 A

Robust General Purpose Simplified Installation Internally Bypassed Competitive with Star/ Delta Starters The DFE is Fairford s internally bypassed, non optimizing soft starter which is perfect for panel builders and end users alike The DFE offers easy installation and is designed to be fitted with minimal disruption to production. The DFE is cost effective, low maintenance and has an excellent service lifetime. To the user it offers competitive pricing, soft stopping and the removal of high transient currents. To panel builders it is an ideal substitute for a Star/ Delta starter because it fits into a similar footprint, thus simplifying installation. It is now available from 22 Amps to 500 Amps. Internally Bypassed Internal bypassing of the Thyristors at the top of ramp allows for reduction in heat and cabinet size. Costs are reduced in ancillary equipment and these savings are passed on to the end user. Simplified Installation Rapid build and install time. No need to change wiring configurations All six wires of the Star/Delta configuration can be used to minimise installation and design costs. DFE vs. Star/Delta Starters A competitive subsititution Lower maintenance costs Less stress on auxiliary equipment when starting Reduced down time Low cost of ownership www.fairford.com/dfe

3S Technology Automatic ramp control profiles ensure smooth start and stop performance, delivering stable acceleration and deceleration in all operating conditions. Case Study 3S Technology allows a 30 second soft start and a 30 second soft stop time, which other systems which cannot achieve. Thus being able to attain a Trip Class 30 start duty rating for the heavier duty starting applications. 3S Technology H3 Pump Controls, a division of Triple H Specialty Co. Inc, was challenged to provide a small rural municipal in Alston, Georgia, USA with a high quality, economical, and reliable soft starter solution for the town s new water well project. H3 Pump Controls quickly decided that the Fairford DFE soft starter product had exactly what we needed. The key decision factors in choosing the DFE were, a basic setup soft starter was needed to enable the municipality to maintain the operation of the product after the purchase, with little or no maintenance. An economical approach was needed for the soft starter to help meet the local government s budget demands. A rugged soft start with great reliability was required to keep the confidence of the municipality.

Dimensions Specification DFE-02 to DFE-08 Operational Voltage 230 460 VAC rms 3-Phase (-15% +10%) 125 mm (4.92 ) Ø 6.5 mm (0.25 ) 135 mm (5.31 ) 90 mm (3.54 ) Weight = 2.3 kg (5.07 lbs) 60 mm (2.36 ) 132 mm (5.21 ) 140 mm (5.51 ) Rated Frequency 50 60 Hz ± 2 Hz Index Rating Trip Class 10 DFE-02 to DFE-26 3-23:697 DFE-30 to DFE-38 3-23:1177 Control Supply Soft Start/Stop Control 24 VDC Supplied externally to terminals X1-X2 DFE-02 to DFE-16 power supply 4 VA DFE-22 to DFE-38 power supply of 12 VA, 4 A for 250 ms 24 VDC/110 VAC galvanically isolated terminals A1-A2 DFE-12 to DFE-16 203 mm (7.99 ) 158 mm (6.20 ) 74 mm (2.91 ) Indication Start Time Stop Time Multifunction LED on the front of the unit 0.5 to 30 seconds 0 to 30 seconds 145 mm (5.71 ) Ø 8.5 mm (0.33 ) 160 mm (6.30 ) 165 mm (6.50 ) Auxiliary Circuits (Relays) Run - 13/14, Ready - 23/24 230 VAC 3A, Ac11 Power Terminals Input 1/L1, 3/L2 and 5/L3 Output 2/T1, 4/T2 and 6/T3 Up to 55 kw (75 HP) IP20 rated wire clamping terminals 75 kw (100 HP) to 280 kw (400 HP) External Busbars Weight = 3.5 kg (7.72 lbs) DFE-22 to DFE-26 145 mm (5.71 ) 203 mm (7.99 ) 160 mm (6.30 ) 122 mm (4.79 ) 158 mm (6.20 ) 76 mm (3.00 ) 165 mm (6.50 ) IP Rating Up to 55 kw (75 HP) IP20 75 kw (100 HP) to 280 kw (400 HP) IP00 Terminal cover kit available - PLS-DFE-001, DFE-22 to DFE-26 Ambient Temperature 0 C to 40 C Above 40 C de-rate linearly by 2% of unit FLC per C to a de-rate of 40% at 60 C Transport and Storage -25 C to 60 C -25 C to 75 C (not exceeding 24 hours) Ø 8.5 mm (0.33 ) Weight = 4.3 kg (9.48 lbs) 48 mm (1.89 ) Altitude 1,000 m Above 1,000 m de-rate linearly by 1% of unit FLC per 100 m to a maximum altitude of 2,000 m Above 2,000 m contact Fairford Electronics Ltd. DFE-30 to DFE-38 M8 clearance 300 mm (11.81 ) 296.5 mm (11.67 ) 204 mm (8.03 ) 160 mm (6.30 ) M10 Earth 198.6 mm (7.82 ) 104 mm (4.10 ) 320 mm (12.60 ) Humidity Standards Max. 85% non-condensing, not exceeding 50% at 40 C IEC 60947-4-2; EN 60947-4-2 AC Semiconductor Motor Controllers and Starters UL, ACMA & CE Weight = 13.5 kg (29.76 lbs) 55 mm (2.17 )

Sizing Guide For application specific sizing, use the online Soft Starter Selector: www.fairford.com Motor Rating Trip Class 2 Trip Class 10 Trip Class 20 Trip Class 30 230 V 400 V 460 V 3-5: 355 (A) HP (A) kw (A) HP 10 starts/hour 3-23: 697 5 starts/hour 4-19: 701 5 starts/hour 4-29: 691 5 starts/hour 15.2 5 15.5 7.5 14 10 DFE-02 DFE-02 DFE-04 DFE-04 22 7.5 22 11 21 15 DFE-02 DFE-04 DFE-04 DFE-06 28 10 29 15 27 20 DFE-04 DFE-06 DFE-06 DFE-08 28 10 35 18.5 34 25 DFE-06 DFE-06 DFE-08 DFE-12 42 15 41 22 40 30 DFE-06 DFE-08 DFE-12 DFE-16 54 20 55 30 52 40 Long-arr DFE-12 DFE-16 DFE-22 54 20 66 37 65 50 Long-arr DFE-14 DFE-22 DFE-22 80 30 80 45 77 60 Long-arr DFE-22 DFE-22 DFE-24 80 30 97 55 96 75 Long-arr DFE-22 DFE-24 DFE-26 130 50 132 75 124 100 Long-arr DFE-26 LONG-ARR LONG-ARR 3-23: 1177 4-19: 1181 4-29: 1171 130 50 132 75 124 100 Long-arr LONG-ARR DFE-30 DFE-32 154 60 160 90 156 125 Long-arr DFE-30 DFE-32 DFE-34 192 75 195 110 180 150 Long-arr DFE-32 DFE-34 DFE-36 192 75 230 132 240 200 Long-arr DFE-34 DFE-36 DFE-38 248 100 280 160 240 200 Long-arr DFE-36 DFE-38 312 125 350 200 302 250 Long-arr DFE-38 360 150 350 200 361 300 Long-arr DFE-38 Product Options APSU005-R PSU 5R Series APSU006-R PSU 6R Series 24 VDC Power Supply for DFE-02 to DFE-16 Can control up to 3 DFE soft starters Input Voltage 90 VAC 264 VAC Output Voltage 24 VDC 18 Watt Output UL Listed 24 VDC Power Supply for DFE-22 to DFE-38 One power supply for each DFE soft starter Input Voltage 85 VAC 264 VAC Output Voltage 24 VDC 60 Watt Output UL Listed For more information on the DFE contact your local distributor + 44 (0)1752 894554 www.fairford.com

Robust General Purpose For more information on the DFE contact your local distributor + 44 (0)1752 894554 www.fairford.com Fairford Electronics reserves the right to change or update, without notice, any technical information contained in this brochure. Fairford Electronics also reserves the right, without notice, to change the design or construction of the product and to discontinue. BRO-DFE-001-V03