Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AY1X/S1139

Similar documents
Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-RS4

UNIVERSAL MAGNETIC FIELD SENSORS FOR PNEUMATIC CYLINDERS. Sense it! Connect it! Bus it! Solve it!

Rotative measurement Incremental rotary encoder RI-10S10C-2B500-H1181

Rotative measurement Incremental rotary encoder Ri-10S10C-2B5000-H1181

Rotative measurement Incremental rotary encoder Ri-10S10C-2B1000-H1181

UNIVERSAL MAGNETIC FIELD SENSORS FOR PNEUMATIC CYLINDERS. Sense it! Connect it! Bus it! Solve it!

Rotative measurement Absolute rotary encoder / Multiturn RM-29S10C-9A28B-R3M12

Contactless Encoder with Stainless Steel Housing Incremental: ppr RI360P0-EQR24M0- INCRX2-H1181

Universal Magnetic Field Sensors

INDUCTIVE SENSORS FOR ROTARY ACTUATORS. Sense it! Connect it! Bus it! Solve it!

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Mechanical Kiln Monitoring (MKM) System

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Alarm contacts for pressure gauges and thermometers

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Electronic Limit Switch Type

Type Electronic Limit Switch

Flap-Type Flow Meter Prall

Pneumatic control unit for decentralized automation of ELEMENT process valves

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

RI360P0-QR24M0- INCRX2-H1181 Contactless Encoder Incremental

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

TZIM. Electropneumatic Analog Positioner 10/ EN

switchcontrol The robust opto-electric position indicator

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Compact cylinders series NYD Double acting with magnetic piston, ISO M5 to G1/8 Piston Ø 20 to 100 mm

Electrical position feedback for actuator sizes Ø mm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Flow sensors. 324 Hans Turck GmbH & Co. KG Tel Fax

INDUCTIVE SENSORS FOR UTILITY VEHICLES. Sense it! Connect it! Bus it! Solve it!

JUMO dtrans p20 DELTA

Type Code Connection and Extension Cables M8

Pneumatic cylinders, piston-ø 8 25 mm Single acting DIN ISO 6432

INSTRUCTION MANUAL (ATEX / IECEx)

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1.

Position Switches Series 8060/2

Limit Switch Type 3776

YFC. Limit switch. Ex d. 24 operating head types

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Solenoid Valve Island Type 3965

Pneumatic cylinders, piston-ø mm Double acting with magnetic piston DIN ISO 15552

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

Direct-acting 3/2 way plunger valve

Sensor boxes SRBE Key features and product range overview

ExBin-P Pressure switches 5 Pa Pa

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Ex m Solenoid Operator Type 0519

Linear actuators DFPI

Operating Instructions. Angle Seat Control Valve. Type 7020

Series 3730 Electropneumatic Positioner Type

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

Position Switches Series 8070/2

Sentronic PLUS 614 Series

Metal tube variable area flowmeter for gases, liquids and steam

Product specification

Product specification

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Ex Pressostat EXPK 944/947/953. Applications. Features

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

PHOENIX CONTACT - 01/2008

INSTRUCTION MANUAL (ATEX / IECEx)

Product specification

Proportional Solenoid for Hydraulics ATEX + IECEX

CPLab / CP Factory. Application module magazine. Data sheets

Components and parts list 4 5. Data sheet sensor SJ 3,5-SN 5 6. Cable gland 6.1 Cable gland nickel-plated 6.2 Cable gland stainless steel

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Position Switches Series 8074/2

Level limit switch Series RF 3000 Selection list

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Cylindrical Inductive Proximity Sensor GX-M SERIES

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Compact pressure switch Model PCS

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

MA-400M. Features. Mini-Bypass Magnetic Level Gauge. Description: Application:

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Technical Documentation about limit switch boxes for rotary- and linear atuators acc. to guidline 94/9/EC, IBExU 07 ATEX 1155

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM

Capacitive Sensors. Series 80 - PNP

Transcription:

ATEX category II 1 G, Ex Zone 0 ATEX category II 1 D, Ex Zone 20 For T-groove cylinders without mounting accessories Optional accessories for mounting on other cylindrical housings. One-hand mounting possible Fine adjustment tool and stopper directly mountable on the sensor Stable mounting Long overtravel For large cylinders DC 2-wire, nom. 8.2 VDC Type designation Ident no. 4685763 Pass speed ð 10 m/s Repeatability ð ± 0.1 mm Temperature drift ð 0.1 mm Hysteresis ð 1 mm Ambient temperature -25 +70 C Output acc. to DIN EN 60947-5-6 (NA- MUR) Output with binary signal NO contact Cable connection Wiring Diagram Output function Switching frequency Voltage Current consumption non-actuated Actuated current consumption 2-wire, NAMUR 1 khz Nom. 8.2 VDC ð 1.2 ma ï 2.1 ma Approval acc. to KIWA 16 ATEX 0051 X Design Rectangular,UNT Dimensions 28 x 5 x 6 mm Housing material Plastic, PP Active area material Plastic, PP Tightening torque fixing screw 0.4 Nm Electrical connection Cables Cable quality 3 mm, Blue, Lif9YYW, PVC, 2m Cable cross section 2 x 0.14 mm 2 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 2283 years acc. to SN 29500 (Ed. 99) 40 C Packaging unit 1 Mounting on the following profiles. Cylindrical design E N K F Functional principle Magnetic field sensors are activated by magnetic fields and are especially suited for piston position detection in pneumatic cylinders. Based on the fact that magnetic fields can permeate non-magnetizable metals, it is possible to detect a permanent magnet attached to the piston through the aluminium wall of the cylinder. Switching state Included in delivery LED,Yellow cable clip 1 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Mounting instructions/description Mounting instructions Thanks to the mounting lip, the sensor can be inserted into the groove from above with one hand. Mount the sensors as follows using the patented wing screw: The wing screw and the female thread feature a lefthand thread. Two small plastic lips keep the screw in position, ready-to-install. Turn the screw clockwise. The screw moves out of the thread and hits the upper grooves with the wings. The sensor is thus pressed down and locked in position. A few degrees up to approximately 1.5 turns of the screw with a slotted screwdriver (blade width 0.5 mm) or a 1.5 mm Allen key are sufficient to ensure vibration-proof fastening, depending on the shape of the slot. A tightening torque of 0.4 Nm is sufficient for safe mounting without damaging the cylinder. The sensor can now withstand an axial and radial tensile load of F=100N applied on the cable. A cable clip is included in the scope of delivery. It enables smooth cable routing in the groove and ensures that the cable is fastened as securely as possible. The corresponding accessories for mounting on other cylindrical housings must be ordered separately. 2 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description KLZ1-INT 6970410 Accessories for mounting the sensors BIM-INT and BIM-UNT on tie-rod cylinders; Cylinder diameter: 32 40 mm; material: Aluminium; Further mounting accessories for other cylinder diameters on request KLZ2-INT 6970411 Accessories for mounting the sensors BIM-INT and BIM-UNT on tie-rod cylinders; Cylinder diameter: 50 63 mm; material: Aluminium; Further mounting accessories for other cylinder diameters on request UNT-STOPPER 4685751 Accessories for finetuning the switchpoint on N T-groove cylinders; snap-locked in the BIM-UNT fixture; suited for multiple use; material: plastic UNT-JUSTAGE 4685750 Accessories for finetuning the switchpoint on N T-groove cylinders; snap-locked in the BIM-UNT fixture; suited for multiple use; material: metal/plastic KLRC-UNT1 6970626 Accessories for mounting on E cylinders; diameter: 8 25 mm; material: PA 6I/6T / nickel silver; Fire-hazard classification acc. to UL94 - V2 3 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description KLRC-UNT2 6970627 Accessories for mounting on E cylinders; diameter: 25 63 mm; material: PA 6I/6T / nickel silver; Fire-hazard classification acc. to UL94 - V2 KLRC-UNT3 6970628 Accessories for mounting the BIM-UNT sensor on E round cylinders; diameter: 63 130 mm; material: PA 6I/6T / nickel silver; Fire-hazard classification acc. to UL94 - V2 KLRC-UNT4 6970629 Accessories for mounting the BIM-UNT sensor on E round cylinders; diameter: 130 250 mm; material: PA 6I/6T / nickel silver; Fire-hazard classification acc. to UL94 - V2 KLDT-UNT2 6913351 Accessories for mounting the BIM-UNT sensor on dovetail cylinders; groove width: 7 mm; material: PPS KLDT-UNT3 6913352 Accessories for mounting the BIM-UNT sensor on K dovetail groove cylinders; groove width: 9.4 mm; material: PPS 4 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description KLDT-UNT6 6913355 Accessories for mounting on K dovetail groove cylinders; groove width: 7.35 mm; material: PPS IMX12-DI01-2S-2T-0/ 24VDC 7580020 Isolating switching amplifier, 2-channel; SIL2 acc. to IEC 61508; Ex-proof version; 2 transistor outputs; input Namur signal; ON/OFF switchable monitoring of wire-break and short-circuit; toggle between NO/NC mode; signal doubling; removable screw terminals; 12.5 mm wide; 24 VDC power supply 5 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Operating manual Intended use This device fulfills the directive 2014/34/EC and is suited for use in potentially explosive areas according to EN60079-0:2012, +A11:2013, -11:2012. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 1 G and Ex ia IIC T6 Ga and É II 1 D Ex ia IIIC T95 C Da acc. To EN60079-0, +A11 and -11 Local admissible ambient temperature -25 +70 C Installation/Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Service/Maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 6 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com