Applications Enclosed and gasketed, non-metallic emergency lighting system suitable for use in areas where flammable gases or vapors may become present due to abnormal, unusual or accidental conditions defined by NEC as Class I, Division 2, Groups A, B, C and D and. Typical applications include manufacturing plants, refineries, petrochemical and chemical plants, waste and sewerage treatment facilities, food processing facilities, and other industrial manufacturing or process facilities subject to wet or corrosive conditions. Non-hazardous areas where dirt, dust or corrosion would reduce life of ordinary emergency lighting systems. Features Enclosures are raintight and suited for operation in highly corrosive and wet locations. The electronics consist of a solid-state charger, transfer circuit and low voltage battery disconnect circuit. The integrated, illuminated push to test button is mounted on the system housing using a neoprene O-ring gasket to seal out moisture and liquids. Capacity is sufficient for the connection of 6 output watts (maximum). System supports 4 light heads (at.5 Watts each) in any main/ remote combination utilizing up to 6 Watts of output power. This allows for a main unit without any light heads to drive up to 4 remote units or any other combination of 4 lights. Provides % lumen output for 9 minutes of operation with four light heads or 8 minutes of operation with two light heads. The solid-state charger maintains battery at full charge Upon power failure or utility voltage (AC) below 5 V, the DC emergency lighting load is connected to the battery. During emergency operation, the battery is automatically protected from deep discharge damage by a low-voltage battery disconnect (LVD) circuit. Upon restoration of normal power, the charger brings the battery to full capacity within acceptable UL time standards (typically within 24 hours). Integrated, illuminated push to test button: Indicates presence of AC line voltage and system error codes Activates push to test function A universal input circuit allows operation from 2 to 277 Vac, 5/6 Hz lines. Maintenance-free NiCd battery is suited for harsh temperature environments of ºC to +55 ºC (+32 to +3 ºF). Remote lamp head assemblies (one or two) are available for mounting of lamp heads away from main power supply system. An automatic test feature provides periodic self-test of the system functions every 3 days. Status indicator light allows easy monitoring of system status and failure modes. Standard Materials Lighting system: Body: fiberglass reinforced polyester Cover gasket: continuous silicone Push to test switch: fiberglass reinforced polyester (FRP), neoprene gaskets Hub: nickel plated brass Cover screws: stainless steel Lampheads: aluminum Remote unit: Body: fiberglass reinforced polyester (FRP); specially formulated with low resistivity, will not hold static charge Cover screws: stainless steel Gasket: neoprene gasket NEC/CEC Certifications and Compliances UL Standards: 598A (Supplemental Requirements for Luminaires for Installation on Marine Vessels) 924 (Emergency Lighting and Power Equipment) 844 (Electric Luminaires Hazardous Locations) CSA Standards: C22.2 No. 4-M985 unit equipment for emergency lighting C22.2 No. 37-M98 non-incendive electrical equipment for use in Class I, Division 2 hazardous locations Life Safety Code NFPA Section 5-9 (Emergency Lighting) Marine wet locations suitability, Type 4X ccsaus Certified: 275744 35
Order using catalog numbering guide below or select catalog number from tables on following pages. Catalog ing Guide For N2LED Master Units N2LED T Series: N2LED - Emergency Lighting System Entry Location: T - Top Entry of Direct Mounted Lamps: - None 2 - Two Entry Size: - 3/4" NPT Catalog ing Guide For N2LED Remote Units N2LEDR R Series: N2LEDR - Remote Emergency Lighting System of Direct Mounted Lamps: - One 2 - Two Hub Position/Entry Location: R - Right Entry Size: - 3/4" NPT Thermal Performance Operating Temperatures Wire Supply Ambient Temperature T 6 C (4 F) ºC to +55 ºC (+32 ºF to +3 ºF). T6 T s Represent the Maximum Lamp Temperature for Class I, Division 2 Locations T T 35 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Temp Range (ºC) 35-45 326-35 3-325 28-3 26-28 23-26 26-23 2-25 8-2 66-8 6-65 36-6 2-35 - 2 86-85 Temp. Range ( ºF) 664-842 69-662 574-67 538-572 52-536 448-5 42-446 394-49 358-392 33-356 322-329 277-32 25-275 24-248 87-22 85 36
Lamp Comparison Chart Power Lumens CRI Lamp Life (Hours) Color Temp CCT.256 Watts 3. 7 5,+ 5K 2 2.53 Watts 257.8 7 5,+ 5K Photometric and Electrical Measurements at Ambient Temperature (25 C +/- C) Distribution Method Base Orientation Voltage Vdc Current (ma) Power (Watts) Power Factor Absolute Luminous Flux (Lumens) Lumen Efficacy (Lumens Per Watt) Up 2.9 437..256. 3. 4.3 2 Up 2.9 874. 2.53. 257.8 2.6 Note: Drive remote unit lamphead(s) only from the N2LED master unit Wire Sizing For Remote Installations For copper wire, maximum distance (feet) between power supply and remote unit to limit voltage drop to 5%. Wire Gage Maximum Wire Length m (ft) 8 AWG 23.8 (78) 6 AWG 38. (25) 4 AWG 6.4 (98) 2 AWG 96. (35) AWG 52.4 (5) System Status Status Indication Status Description Status Definition No light AC power removed from circuit * Continuous red steady light Battery fully charged *_*_ Red light blinks once every second Battery charging **_**_ Red light blinks twice repeatedly Battery failure ***_***_ Red light blinks three times repeatedly LED lamp head failure ****_****_ Red light blinks four times repeatedly Emergency circuit charger board failure 37
Main System Total Watts Hub Size Voltage Frequency Weight kg (lb) Catalog Emergency Lighting System With Two Direct Mount Lamps 2 3 3/4 2-277 5/6 Hz 3.27 (7.2) N2LED2T Emergency Lighting System Without Direct Mount Lamps 3/4 2-277 5/6 Hz 3.4 (6.7) N2LEDT Remote System Remote Mount With One Lamp Remote Mount With Two Lamps Total Watts Hub Size Hub Position Weight kg (lb) Catalog.5 3/4 Dead End Hub on Right.45 (3.2) N2LEDRR 2 3 3/4 Dead End Hub on Right.59 (3.5) N2LEDR2R Replacement Parts Description Emergency Lamp Kit Emergency Battery Pack Kit Emergency Circuit Charger Board Kit Nickel Plated Brass M25 Male, 3/4" NPT Female Hub Catalog N2LEDLH N2LEDBP N2LEDCB 737DM3T25 38
Dimensions in Millimeters (Inches) Emergency Lighting System With Two Direct Mount Lamps 249. (9.8) 5. (4.) 223. (8.8) (7.9) 46. (5.75) 43. (.7) 95. (3.7) 26. (8.5) 95. (3.7) 89. (7.44) Adjustment Angle Top View Side View 25 25 25 25 25 25 25 25 248.9 (9.8) 248.9 (9.8) 23. (.9) 22.3 (8.7) (7.88) 22.3 (7.9) (8.7) (7.88) 25 25 25 25 25 25 25 25 Emergency Lighting System Without Direct Mount Lamps 5.3 (4.5) 44.3 44.3 43. (.75) (.75) (.7) 44.795.2 46. (5.75) 95. (5.7) 95.2 (3.7) (3.75) (3.75) 5. (4.) 25.9 (8.5) 95.3 (3.75) 9.5 (7.5) 26. (8.5) 95. (3.7) 89. (7.44) 2. (.5) 39
Dimensions in Millimeters (Inches) Remote Mount With One Lamp 29. (8.6) 7. (6.7) 3. (5.6) 9. (3.6) 4. (.6) 85. (3.3) 7. (6.7) 23. (.9) 9. (3.) 53. (6.2) Adjustment Angle Top View Side View 8 8 8 8 9. (3.6) 4
Photometric Data DATA SHOWN IS ABSOLUTE MODEL: N2LED, Wall Mount LED Emergency Luminaire, Single Lamp Candela Distribution Zonal Lumen Summary. 22.5 45. 67.5 9. Zone Lumens % Fixture 663 663 663 663 663-3 7.9 9. 5 63 569 547 54 527-4 25.5 95.8 377 35 37 394 39-6 3.2 99.4 5 88 72 22 249 255 6-9.8.6 2 86 8 97 23 9-9 3.. 25 36 34 42 4 46 9-8.. 3 5 4 6 3 36-8 3.. 35 6 6 9 2 25 4 3 3 6 4 45 2 2 4 5 3 5 2 2 3 2 2 55 2 2 2 2 2 6 65 7 75 8 85 9 Distance in units of mounting height ( ft) 5 fc.5 fc 2.5 fc.2 fc fc. fc MODEL: N2LED, Wall Mount LED Emergency Luminaire, Two Lamp Candela Distribution Zonal Lumen Summary. 22.5 45. 67.5 9. Zone Lumens % Fixture 24 24 24 24 24-3 23.9 89.6 5 96 49 989-4 246.7 95.7 844 764 76 763 737-6 255.9 99.3 5 469 426 46 56 486 6-9.8.7 2 225 26 239 264 234-9 257.8. 25 93 87 7 9 97 9-8.. 3 4 37 4 66 74-8 257.8. 35 7 6 23 44 5 4 7 7 4 26 28 45 4 5 8 6 5 4 4 6 5 4 55 4 4 5 4 3 6 2 2 3 3 2 65 2 2 7 75 8 85 9 Distance in units of mounting height ( ft) fc.5 fc 5 fc.2 fc 2.5 fc. fc fc 4